Search Filters

Search Results

Found 7 results

510(k) Data Aggregation

    K Number
    K234029

    Validate with FDA (Live)

    Manufacturer
    Date Cleared
    2024-07-18

    (211 days)

    Product Code
    Regulation Number
    882.5891
    Reference & Predicate Devices
    Predicate For
    N/A
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    Cefaly Connected - OTC is indicated for:

      1. Acute treatment of migraine with or without aura in patients 18 years of age or older
      1. Preventative treatment of migraine in patients 18 years of age or older
        Cefaly Connected - Rx is indicated for:
      1. Acute treatment of migraine with or without aura in patients 18 years of age or older
      1. Prophylactic treatment of migraine in patients 18 years of age or older
    Device Description

    CEFALY Connected - Rx and CEFALY Connected - OTC consists of neurostimulators, Cefaly Electrodes, and mobile application. The neurostimulators are small, non-invasive, and portable devices meant to be worn on the forehead using a self-adhesive electrode to treat migraines similar to Cefaly® Dual Connected - Rx, and Cefaly® Dual Connected - OTC of K212071. The mobile application, CeCe Miqraine Management App, is a two-way communicatinq, mobile application, installed and run on users' personal mobile devices such as smartphone or tablet. The app is compatible with neurostimulators of CEFALY Connected devices (Rx and OTC). The mobile application communicates with the neurostimulator through Bluetooth and allows users to track the treatments.

    AI/ML Overview

    The provided text describes a 510(k) premarket notification for a medical device called "CEFALY Connected - OTC" and "CEFALY Connected - Rx." The submission focuses on demonstrating substantial equivalence to a predicate device, the "Cefaly® Dual Series" (K212071). Since this is a 510(k) submission, the primary aim is to show that the new device is as safe and effective as a legally marketed predicate device, not necessarily to prove absolute effectiveness against a specific disease. Therefore, the "acceptance criteria" and "study" are primarily focused on demonstrating equivalence and safety/performance as compared to the predicate, especially regarding changes made to the mobile application.

    Here's an analysis of the acceptance criteria and study information:

    Acceptance Criteria and Reported Device Performance

    The core of the submission relies on demonstrating that while there are differences in the mobile application's functionalities, the fundamental medical device functions and underlying technology of the neurostimulator remain equivalent in terms of safety and efficacy to the predicate device.

    Acceptance Criteria CategoryReported Device Performance (Subject Device vs. Predicate)
    Technological EquivalenceSimilarities:
    - Device physical status: Both subject and predicate devices have software applications deployed on commercially available smartphones. (Equivalent)
    - User authentication: Same account creation and login process. (Equivalent)
    - Treatment Logs & Migraine Logs: Record the same patient-reported information. (Equivalent)
    - Migraine Report & Graphical Data: Present the same trends, patterns, and data graphs based on user-provided information. (Equivalent)
    - Bluetooth protocol: Same for neurostimulator. (Equivalent)
    - Power source, charging system, mechanical characteristics (Weight, Dimensions, Channels): Same for the neurostimulator. (Equivalent)
    - Waveform characteristics and output specifications (Program 1 - Acute, Program 2 - Prevent): Same for both neurostimulators (Amplitude, Pulse width, Pulse frequency, Session duration, Maximum average current, Maximum average power density, Biphasic, Rectangular, Full compensated, Symmetrical, Net charge per pulse, Max output voltage/current, Pulse duration, Max Phase Charge, Max current density). (Equivalent)
    - Audio-visual Indications & Device button functions: Used in the neurostimulators for both devices are the same. (Equivalent)
    - Electrode (Dimensions, Gel used, Packaging configuration, Number of electrodes, Electrode storage): Same for both devices. (Equivalent)
    Differences & Justification for Equivalence:
    - Major App functionalities: Subject device has 2-way communication enabling remote control (start/stop treatment, control intensity) of the neurostimulator via Bluetooth. Predicate only had treatment log, migraine log, and PDF download. Justification: Neurostimulator can operate independently. Mobile app interface is supplementary and can be overridden by neurostimulator controls. Remote control functions are consistent with neurostimulator's existing controls and validated through software system validation and interoperability testing. The "Stop" button in the app functions similarly to physically detaching the device. No new questions of safety or efficacy are raised.
    - User Interface: Treatment Session Controls: Subject device allows start/stop treatment sessions, increase/stabilize intensity via app. Predicate had no app treatment session controls. Justification: Controls in subject device app are consistent with neurostimulator, validated through software system validation and interoperability testing. App controls are supplementary and can be overridden by physical device controls. No new questions of safety/efficacy.
    - Monitoring Treatment Progress: Both visually monitor progress via app UI and audio-visual indications on hardware. Justification: App acts as an accessory, supplements neurostimulator indications, and device can still indicate progress if app malfunctions. No conflicts or new questions of safety/efficacy.
    - Indicators on app interface: Subject device only shows selected treatment type via pop-up at selection; constant display on neurostimulator. Predicate constantly displayed via app. Subject device also has push notifications for active sessions, intensity controls, and preventative treatment reminders. Justification: User is aware of treatment type via neurostimulator visual cues in both cases. Push notifications are supplementary and "non-medical device functions" (reminders), posing no new safety/efficacy questions.
    - Option to Log historical preventative treatment data: Subject device allows logging for both Acute and Preventative sessions. Predicate only allowed Acute. Justification: This is a non-medical device function and does not raise new questions of safety and effectiveness.
    Software Safety & PerformanceSoftware Verification and Validation, including interoperability testing: Performed to validate control functions and associated features of the mobile app. Reported Performance: Results demonstrate that the user interface is consistent with intended use. Intensity values displayed by app and actual intensity values are almost same (acceptable tolerance limit of -2%). Bluetooth interface does not introduce unacceptable latency. EMF compatibility and wireless safety demonstrated in predicate K212071.
    CybersecurityThreat modeling and penetration testing: Conducted to identify security threats. Reported Performance: Control measures applied and traceability documented in a cybersecurity report.
    Special Controls ComplianceAddressed & Re-verified in this submission:
    1. Software verification, validation, and hazard analysis: Performed (see section 7, Performance Testing - Bench, and Section 11, Conclusion).
    2. Labeling for CeCe Migraine Management App: Includes information on operation and typical sensations.
    Addressed in K212071 (Predicate): Biocompatibility, Electromagnetic compatibility, electrical/mechanical/thermal safety, technical parameters characterization, electrode testing, clinical performance data (for neurostimulators), and comprehensive labeling requirements.

    Study Details

    The provided document describes studies primarily focused on bench testing and software validation to demonstrate substantial equivalence, rather than a clinical trial proving direct efficacy of the new components.

    1. Sample size used for the test set and the data provenance:

      • Test Set Sample Size: Not explicitly stated in terms of patient numbers or a dataset size for evaluating device performance. The testing described is "Software Verification and Validation, including interoperability testing" and "Bench testing." These tests would typically use specific test cases and simulated scenarios rather than a traditional patient test set.
      • Data Provenance: Not applicable in the context of patient data. The tests are technical assessments of software functionality and device interoperability.
    2. Number of experts used to establish the ground truth for the test set and the qualifications of those experts:

      • Not applicable. The ground truth for software verification and validation, and bench testing, is established by predefined functional requirements, technical specifications, and expected outputs based on engineering principles and regulatory standards. It's not typically established by clinical experts in the same way as an AI diagnostic study.
    3. Adjudication method for the test set:

      • Not applicable. As the testing pertains to technical performance and software functionality (e.g., whether a button does what it's supposed to, whether Bluetooth communication is stable, whether intensity values are within tolerance), there isn't a "ground truth" established by human experts that requires adjudication.
    4. If a multi reader multi case (MRMC) comparative effectiveness study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance:

      • No MRMC study was done. The device is a "Transcutaneous Electrical Nerve Stimulator to Treat Headache," and the changes concern the mobile application interface. This is not an AI-assisted diagnostic device, nor does it involve "human readers" in a clinical interpretation context.
    5. If a standalone (i.e. algorithm only without human-in-the-loop performance) was done:

      • The core neurostimulator device functions independently of the mobile app. The document explicitly states: "The neurostimulator can perform treatment sessions independent of the mobile application." The mobile app provides supplementary control and monitoring functions. So, in a sense, the neurostimulator's standalone performance (without the app) is inherent to its prior clearance (K212071) and acknowledged in this submission. The "algorithm" here refers to the software controlling the neurostimulator and the mobile app's functionalities. The studies performed were on the software (verification, validation, interoperability) and system (bench testing, cybersecurity).
    6. The type of ground truth used (expert consensus, pathology, outcomes data, etc.):

      • The "ground truth" for the tests performed (software verification, validation, interoperability bench testing) would be the device's technical specifications, design requirements, and regulatory standards. For example, if the app is supposed to display device battery level, the ground truth is the actual battery level measured by the device. If the app sends control commands, the ground truth is whether the device responded correctly and within expected parameters.
      • The effectiveness of the core neurostimulator for migraine treatment was established in prior submissions (K212071) through clinical performance data, which would have involved outcomes data related to migraine treatment. However, this submission focuses on the safety and performance of the new software features in the mobile app.
    7. The sample size for the training set:

      • Not applicable. This is not a machine learning or AI device that requires a training set in the conventional sense. The "software" in question refers to the mobile application's control logic and user interface, which are developed through traditional software engineering methods, not statistical learning from large datasets.
    8. How the ground truth for the training set was established:

      • Not applicable, as there is no training set for an AI/ML algorithm.
    Ask a Question

    Ask a specific question about this device

    K Number
    K212071

    Validate with FDA (Live)

    Manufacturer
    Date Cleared
    2022-12-13

    (529 days)

    Product Code
    Regulation Number
    882.5891
    Reference & Predicate Devices
    Predicate For
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    Cefaly Dual Connected - OTC and Cefaly Dual Enhanced with RFID - OTC are indicated for:

    1. Acute treatment of migraine with or without aura in patients 18 years of age or older
    2. Preventative treatment of migraine in patients 18 years of age or older

    Cefaly Dual Connected - Rx and Cefaly Dual Enhanced With RFID - Rx are indicated for:

    1. Acute treatment of migraine with or without aura in patients 18 years of age or older
    2. Prophylactic treatment of migraine in patients 18 years of age or older
    Device Description

    The Cefaly® Dual Series of devices are small, non-invasive, and portable devices meant to be worn on the forehead using a self-adhesive electrode to treat migraine similar to Cefaly® Dual (K201895 OTC and K173006 R.). The devices are similar in construction and materials and use the same components (electronics and electrical components, and firmware), including the component that comes into patient contact which is the CEFALY® Electrode. The notable differences between the Subject and Predicate devices are Bluetooth technology and mobile application for the purpose of displaying device data, the new docking station, RFID for electrode detection, audio/visual indicators, and the dimensions and the weight of the electrode.

    AI/ML Overview

    The provided text is a 510(k) premarket notification for the Cefaly Dual Series devices. It details the device's characteristics and compares them to predicate devices to demonstrate substantial equivalence. Crucially, this document does not contain information about a study that proves the device meets specific acceptance criteria in the format typically used for demonstrating the performance of a novel AI/ML-based medical device.

    The document states:

    • "No animal testing was required to justify the differences with the corresponding Predicate Devices." (page 40)
    • "No clinical testing was required to justify the differences with the corresponding Predicate Devices." (page 40)

    This indicates that the submission relies on demonstrating substantial equivalence to existing devices through bench testing and comparison of technological characteristics, rather than new clinical performance data to prove efficacy. The changes made to the device (e.g., Bluetooth, RFID, audio/visual indicators, charging system, weight, dimensions, electrode thickness, packaging) are assessed against safety and electrical standards (IEC 60601-1, IEC 60601-1-2, IEC 60601-2-10) and adhesion performance.

    Therefore, I cannot provide the requested information for a study proving acceptance criteria for an AI/ML device because:

    • No acceptance criteria for an AI/ML device are listed. The document pertains to a Transcutaneous Electrical Nerve Stimulator, not a device incorporating AI/ML for diagnostic or therapeutic decision-making.
    • No study proving device performance against such criteria is presented. The "Performance Testing - Bench" section (Table 5.7.1) lists general electrical and EMC safety standards, and adhesion testing for electrodes, but not performance metrics related to migraine treatment outcomes that would typically be evaluated in a clinical trial.

    Without a study described as such in the provided text, I cannot fill in the requested table or additional details. The information provided heavily focuses on hardware changes and their compliance with general safety standards, and substantiates that the functionality of the device (e.g., electrical stimulation parameters) remains equivalent to the cleared predicate devices, thus not requiring new clinical evidence of effectiveness for migraine treatment.

    Ask a Question

    Ask a specific question about this device

    K Number
    K201895

    Validate with FDA (Live)

    Device Name
    Cefaly Dual
    Manufacturer
    Date Cleared
    2020-09-29

    (83 days)

    Product Code
    Regulation Number
    882.5891
    Reference & Predicate Devices
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The Cefaly® Dual is indicated for

    • The acute treatment of migraine with or without aura in patients 18 years of age or older.
    • The prophylactic treatment of episodic migraine in patients 18 years of age or older.
    Device Description

    The Cefaly® Dual device indicated for an OTC (also referred to as the Subject Device) is a supraorbital transcutaneous electrical nerve stimulator device to be applied on the forehead. A self-adhesive electrode with 2 conductive zones is placed on the forehead. This double electrode is directly connected to the device. The Subject Device is operated by a rechargeable battery. Pressure on the single button allows selecting and starting a stimulation program, which runs automatically. The electrical impulses generated by the Subject Device are transmitted transcutaneously via the supraorbital electrode to excite (trigger action potentials on) the supratrochlearis and supraorbitalis nerves. Supratrochlearis and supraorbitalis (or supratrochlear and supraorbital) nerves belong to the upper branch of the trigeminal nerve (V1). Therefore, the supraorbital neurostimulation is also known as external trigeminal nerve stimulation. The supraorbital neurostimulation generates an analgesic effect and is intended to treat migraine headaches.

    AI/ML Overview

    This document is a 510(k) premarket notification approval letter for the Cefaly® Dual device, indicating its substantial equivalence to a previously cleared predicate device. It primarily focuses on the device's technological characteristics, indications for use, and a non-clinical human factors study to support a change from prescription (Rx) to over-the-counter (OTC) use.

    Based on the provided text, the device itself does not involve an AI/ML algorithm that requires specific acceptance criteria related to its performance in tasks like image classification or predictive modeling. Instead, it's a Transcutaneous Electrical Nerve Stimulator (TENS) device. Therefore, many of the requested points regarding AI/ML acceptance criteria, performance metrics (like sensitivity, specificity, AUC), ground truth establishment, training sets, and MRMC studies are not applicable to this submission.

    The "study that proves the device meets the acceptance criteria" in this context refers to demonstrating the device's equivalent performance and safety to its predicate, particularly for its proposed OTC use.

    Here's a breakdown based on the document:


    Acceptance Criteria for Cefaly® Dual (for OTC use):

    The acceptance criteria are implicitly tied to demonstrating the substantial equivalence to the predicate device (Cefaly® Dual K173006) and showing that the device is safe and effective for over-the-counter use without requiring a prescription.

    The document highlights the following as crucial for demonstrating equivalence/acceptance:

    • Identical Technological Characteristics: The device must be technologically identical to the predicate device in design, materials, energy source, electrical impulse parameters (pulse width, frequency, current, waveform), and software.
    • Identical Intended Use/Clinical Application: The clinical application and intended users (patients 18 years or older for acute treatment of migraine with or without aura, and prophylactic treatment of episodic migraine) must remain the same as the predicate.
    • Safety and Effectiveness for OTC Use: The primary additional "acceptance criterion" for the OTC claim is demonstrating that the device can be used safely and effectively by lay users without professional guidance. This is addressed through a Human Factors validation study.

    Study Proving Device Meets Acceptance Criteria:

    The study that proves the device meets the (implicit) acceptance criteria for OTC marketing is primarily a Non-Clinical Human Factors Validation Study.

    1. Table of Acceptance Criteria (Implicit) and Reported Device Performance:

    Acceptance Criterion (Implicit)Reported Device Performance and Evidence from Submission
    Technological Equivalence to Predicate DeviceMet: The Subject Device (Cefaly® Dual for OTC) is stated to be "identical to the legally marketed Predicate Cefaly® Dual (K173006) in terms of technological characteristics (design, material, and energy source)." Specific parameters like power source, channels, software, maximum output current, pulse width, frequency, session duration, waveform, shape, net charge per pulse, current density, and power density are listed as "Equivalent" to the Predicate.
    Identical Clinical Application and Intended UsersMet: The indications for use for acute and prophylactic treatment of migraine in patients 18 years or older are explicitly stated to be the same as the predicate device. The document explicitly says, "While the clinical application, the intended users and use remains identical..."
    Safety and Effectiveness for Over-The-Counter (OTC) UseMet: A "Human Factors validation study was conducted with the Cefaly® Dual (Subject Device)" to support the change in indications for use from Rx to OTC. The successful completion of this study implied the device is safe and effective for use by lay users. The FDA's clearance (K201895) further confirms this.
    Compliance with International StandardsMet: The Subject Device is stated to be "compliant to the same international standards as the legally marketed Predicate (K173006)."

    2. Sample Size Used for the Test Set and Data Provenance:

    • Test Set Sample Size: The document only mentions a "Human Factors validation study" but does not specify the sample size for this study.
    • Data Provenance: Not explicitly stated, but Human Factors studies are typically prospective tests conducted in a simulated or real-world use environment. The manufacturer is CEFALY Technology, based in Belgium, so participants could be from Europe or the US, but this is not detailed.

    3. Number of Experts Used to Establish the Ground Truth for the Test Set and Qualifications:

    • This question is not applicable in the context of this device. A TENS device does not generate data that requires expert labeling or ground truth establishment in the way an AI/ML algorithm for medical image analysis would.
    • For Human Factors studies, "experts" are typically human factors specialists, usability engineers, and potentially clinicians who understand the device's use environment, rather than experts establishing "ground truth" in clinical data. The document does not detail the expertise of those involved in the human factors study design or evaluation.

    4. Adjudication Method for the Test Set:

    • Not applicable for this type of device and study. Human Factors studies involve observing user interactions, identifying use errors, and assessing user comprehension, rather than adjudicating clinical findings.

    5. If a Multi-Reader Multi-Case (MRMC) Comparative Effectiveness Study was Done:

    • No, this was not done. The device cleared via a 510(k) pathway by demonstrating substantial equivalence to a predicate. The document explicitly states: "Clinical performance testing was not performed with the Subject Device to support equivalence, as there are no differences between the Subject Device and the Predicate Device."
    • MRMC studies are typically for AI/ML algorithms where human performance with and without AI assistance is being compared. This device is a direct-to-patient TENS.

    6. If a Standalone (i.e. algorithm only without human-in-the-loop performance) was Done:

    • Not applicable. This device is hardware with simple embedded software. It is not an AI/ML algorithm that operates in a "standalone" analytical capacity. Its performance is tied directly to its hardware function and user interaction.

    7. The Type of Ground Truth Used:

    • Not applicable for clinical efficacy. As noted, clinical performance testing was not performed for this submission. The "ground truth" for the Human Factors study would be the identification of all potential use errors and the successful demonstration that lay users can safely and effectively operate the device according to its instructions for use. This isn't "ground truth" in the diagnostic or prognostic sense.

    8. The Sample Size for the Training Set:

    • Not applicable. This device does not use an AI/ML algorithm that is "trained" on a dataset in the conventional sense. The software functions are fixed programs (Program 1 for acute treatment, Program 2 for prophylactic treatment) identical to the predicate device.

    9. How the Ground Truth for the Training Set Was Established:

    • Not applicable. See point 8.
    Ask a Question

    Ask a specific question about this device

    K Number
    K173006

    Validate with FDA (Live)

    Device Name
    Cefaly Dual
    Manufacturer
    Date Cleared
    2017-11-28

    (62 days)

    Product Code
    Regulation Number
    882.5891
    Reference & Predicate Devices
    Predicate For
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The Cefaly® Dual is indicated for:

    • The acute treatment of migraine with or without aura in patients 18 years of age or older.

    • The prophylactic treatment of episodic migraine in patients 18 years of age or older.

    Device Description

    The Cefaly® Dual device is a supraorbital transcutaneous electrical nerve stimulator device to be applied on the forehead. A self-adhesive electrode with 2 conductive zones is placed on the forehead. This double electrode is directly connected to the device.

    The Cefaly® Dual is operated by a rechargeable battery. A pressure on the single button allows selecting and starting a stimulation program, which runs automatically.

    The electrical impulses generated by the Cefaly® Dual device are transmitted transcutaneously via the supraorbital electrode to excite (trigger action potentials on) the supratrochlearis and supraorbitalis nerves. Supratrochlearis and supraorbitalis (or supratrochlear and supraorbital) nerves belong to the upper branch of the trigeminal nerve (VI). Therefore, the supraorbital neurostimulation is also known as external trigeminal nerve stimulation. The supraorbital neurostimulation generates an analgesic effect and is intended to treat migraine headaches.

    AI/ML Overview

    This document does not contain the detailed information necessary to complete the requested table and provide answers for all points. The provided text is a 510(k) summary for the Cefaly® Dual device, making a claim of substantial equivalence to two predicate devices (Cefaly® Acute and Cefaly®). While it describes the device's technical specifications and indications for use, it does not include the results of a clinical study or performance testing against specific acceptance criteria for efficacy or safety.

    Here's a breakdown of what can and cannot be answered based on the provided text:

    1. Table of acceptance criteria and reported device performance:

    This information is not available in the provided text. The document focuses on showing the Cefaly® Dual is technically equivalent to its predicates. It does not present clinical performance data or acceptance criteria for that data in this summary.

    2. Sample size used for the test set and the data provenance:

    This information is not available as no clinical test set or study data is presented.

    3. Number of experts used to establish the ground truth for the test set and the qualifications of those experts:

    This information is not available as no clinical test set or ground truth establishment is described.

    4. Adjudication method for the test set:

    This information is not available.

    5. If a multi reader multi case (MRMC) comparative effectiveness study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance:

    This information is not available. The Cefaly® Dual is a transcutaneous electrical nerve stimulator, not an AI-assisted diagnostic device that would involve human readers.

    6. If a standalone (i.e. algorithm only without human-in-the-loop performance) was done:

    This information is not applicable. The Cefaly® Dual is a medical device, not an algorithm.

    7. The type of ground truth used:

    This information is not available.

    8. The sample size for the training set:

    This information is not available as no training set for a machine learning algorithm is mentioned.

    9. How the ground truth for the training set was established:

    This information is not available.


    Summary of what the document does provide:

    • Device: Cefaly® Dual, a supraorbital transcutaneous electrical nerve stimulator.
    • Indications for Use:
      • Acute treatment of migraine with or without aura in patients 18 years of age or older.
      • Prophylactic treatment of episodic migraine in patients 18 years of age or older.
    • Mechanism of Action: Transmits electrical impulses via a supraorbital electrode to excite supratrochlearis and supraorbitalis nerves (external trigeminal nerve stimulation) to generate an analgesic effect.
    • Substantial Equivalence: Claimed against Cefaly® Acute (K171446) and Cefaly® (K160237). The Cefaly® Dual combines the stimulation programs and indications of these two predicate devices.
    • Technical Characteristics: Detailed comparison of Cefaly® Dual with its predicates, showing identical physical dimensions, weight, housing materials, electrodes, power source, pulse width, waveform, and net charge per pulse. The key difference is that Cefaly® Dual includes two fixed programs (one for acute treatment at 100 Hz, one for prophylactic at 60 Hz), whereas each predicate only had one.
    • Non-Clinical Performance Testing: Cefaly® Dual is compliant with the same international standards (IEC 60601-1, -1-2, -1-6, -1-11, -2-10, IEC 62366) as the predicate devices. This indicates electrical safety, electromagnetic compatibility, usability, and specific requirements for nerve stimulators.

    The provided text is a regulatory submission for substantial equivalence based on technical and performance similarities to previously cleared devices, rather than a report on a clinical trial with specific acceptance criteria and outcome measurements for the new device.

    Ask a Question

    Ask a specific question about this device

    K Number
    K171446

    Validate with FDA (Live)

    Device Name
    Cefaly Acute
    Manufacturer
    Date Cleared
    2017-09-15

    (122 days)

    Product Code
    Regulation Number
    882.5891
    Reference & Predicate Devices
    Predicate For
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    Cefaly® Acute is indicated for the acute treatment of migraine with or without aura in patients 18 years of age or older.

    Device Description

    The Cefaly® Acute device is a supraorbital transcutaneous electrical nerve stimulator device to be applied on the forehead. A self-adhesive electrode with 2 conductive zones is placed on the forehead. This double electrode is directly connected to the device. The Cefaly® Acute is operated by a rechargeable battery. A pressure on the single switch starts a program, which runs automatically for 60 minutes.

    AI/ML Overview

    This document describes the Cefaly® Acute device and its substantial equivalence to a predicate device (Cefaly®). It includes a summary of a clinical trial used to support its safety and efficacy.

    1. Table of Acceptance Criteria and Reported Device Performance

    The document does not explicitly state "acceptance criteria" for the device's performance in a table format with specific numerical targets. However, the primary outcome of the clinical study serves as the de-facto performance measure demonstrating efficacy. The performance of the Cefaly® Acute is compared against a sham group.

    Acceptance Criteria (Implied)Reported Device Performance (Cefaly® Acute)Reported Device Performance (Sham Group)Statistical Significance
    Reduction in pain score from baseline to 1 hourMean change in VAS pain score: -3.46 ± 2.32Mean change in VAS pain score: -1.78 ± 1.89Statistically significant (p < 0.05 for treatment difference of -1.68)
    Pain relief at 2-hour and 24-hour time pointsObservedObservedObserved
    Anti-migraine rescue medication intake within 24 hoursNot significantly lower (implies no specific numerical target met or not achieved statistical significance)Not significantly lowerNot statistically significant

    2. Sample Size and Data Provenance

    • Test Set Sample Size: 106 patients (93 females and 13 males). This refers to the clinical study population.
    • Data Provenance: The document does not explicitly state the country of origin. The study is described as a "Randomized, sham-controlled clinical trial," indicating it was a prospective study.

    3. Number of Experts and Qualifications for Ground Truth

    This information is not provided in the document. The study measures patient-reported pain scores (VAS), not an interpretation by experts like radiologists. Therefore, there's no mention of experts establishing ground truth in the context of image interpretation or similar tasks.

    4. Adjudication Method for the Test Set

    This information is not applicable/not provided as the primary outcome measure (VAS pain score) is a patient-reported outcome, not an interpretation requiring adjudication by multiple readers.

    5. Multi-Reader Multi-Case (MRMC) Comparative Effectiveness Study

    A MRMC comparative effectiveness study was not done. This type of study typically applies to imaging diagnostics where human readers interpret medical images. The Cefaly® Acute is a therapeutic device for pain management, and its efficacy was assessed through a randomized, sham-controlled clinical trial directly measuring patient outcomes.

    6. Standalone (Algorithm Only) Performance Study

    A standalone performance study was not done. The Cefaly® Acute is a device, not an algorithm in the typical sense of AI/ML software. Its performance is measured by its therapeutic effect on patients, not by its ability to process data independently of human interaction.

    7. Type of Ground Truth Used

    The ground truth used was patient-reported outcomes, specifically the change in pain score from baseline measured on an 11-point Visual Analog Scale (VAS).

    8. Sample Size for the Training Set

    This information is not applicable/not provided. The Cefaly® Acute is a medical device, not an AI/ML algorithm that requires a training set in the conventional sense. The document describes a clinical trial evaluating the therapeutic effect of the device.

    9. How the Ground Truth for the Training Set was Established

    This information is not applicable/not provided for the same reason as point 8.

    Ask a Question

    Ask a specific question about this device

    K Number
    K160237

    Validate with FDA (Live)

    Device Name
    Cefaly
    Manufacturer
    Date Cleared
    2016-03-04

    (32 days)

    Product Code
    Regulation Number
    882.5891
    Reference & Predicate Devices
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The Cefaly® device is indicated for the prophylactic treatment of episodic migraine in patients 18 years of age or older.

    Device Description

    Cefaly® device is a supraorbital transcutaneous nerve stimulator device to be applied on the forehead. A self-adhesive electrode with 2 conductive zones is placed on the forehead. This double electrode is directly connected to the device.

    Cefaly® is operated by a rechargeable battery. A pressure on the single switch starts a program, which runs automatically for 20 minutes.

    The electrical impulses generated by the Cefaly® device are transmitted transcutaneously via the supraorbital electrode to excite (trigger action potentials) the supratrochlearis and supraorbitalis nerves. Supratrochlearis and supraorbitalis (or supratrochlear and supraorbital) nerves belong to the upper branch of the trigeminal nerve (V1). Therefore the supraorbital neurostimulation is also known as external trigeminal nerve stimulation. The supraorbital neurostimulation generates a sedative effect and is intended to treat migraine headaches.

    AI/ML Overview

    This document describes the CEFALY® device, a supraorbital transcutaneous nerve stimulator for the prophylactic treatment of episodic migraine. It is a 510(k) premarket notification for a modified version of an already legally marketed device.

    Here's a breakdown of the requested information based on the provided text:

    1. Table of Acceptance Criteria and Reported Device Performance

    The provided document describes a 510(k) for a modified version of the CEFALY® device. The core of this submission is substantial equivalence to a predicate device (the original CEFALY® device, De Novo Number DEN120019 and 510(k) Number K122566). The document explicitly states that the "scientific technology of the modified Cefaly® device are identical to those of the original version of the Cefaly® device" and "The modified version of the Cefaly® has exactly the same output stimulation parameters than the legally marketed Cefaly®."

    Therefore, the acceptance criteria are implicitly that the modified device's performance, particularly its safety and effectiveness for its indicated use, is equivalent to the predicate device. The performance is reported as being identical to the predicate.

    Acceptance Criteria (Implicit from Substantial Equivalence to Predicate)Reported Device Performance (Modified CEFALY®)
    Safety and Effectiveness for Prophylactic Treatment of Episodic MigraineAs safe and effective as the legally marketed predicate CEFALY® device. Risk analysis showed no unacceptable risk.
    Output Stimulation ParametersExactly the same as the legally marketed predicate CEFALY® device.
    Intended UseIdentical to the legally marketed predicate CEFALY® device: prophylactic treatment of episodic migraine in patients 18+ years.

    2. Sample size used for the test set and the data provenance

    The provided document for the 510(k) (K160237) does not describe a new clinical study with an independent test set for the modified device. Instead, it relies on demonstrating substantial equivalence to a predicate device. The modifications concern "power supply, the dimensional specifications, and the fixing system between the device and the electrode." The submission indicates that a "risk analysis did not show any unacceptable risk resulting from these device modifications."

    Therefore, there is no information about a "test set" in the context of evaluating a new algorithm or clinical performance for this specific 510(k) submission. Any clinical data supporting the original predicate device (DEN120019, K122566) would be the basis for efficacy and safety, but that data is not detailed in this document.

    3. Number of experts used to establish the ground truth for the test set and the qualifications of those experts

    As there is no new clinical study or test set described for the modified device in this 510(k) submission, this information is not available in the provided text.

    4. Adjudication method (e.g., 2+1, 3+1, none) for the test set

    Not applicable, as no new test set is described.

    5. If a multi reader multi case (MRMC) comparative effectiveness study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance

    Not applicable. The device is a transcutaneous electrical nerve stimulator, not an AI-powered diagnostic or assistive tool for human readers.

    6. If a standalone (i.e. algorithm only without human-in-the-loop performance) was done

    This refers to an algorithm-only performance study. The CEFALY® device is a physical medical device (nerve stimulator), not an algorithm or AI. Hence, this question is not applicable in the context of this device.

    7. The type of ground truth used (expert consensus, pathology, outcomes data, etc.)

    For the predicate device, the "ground truth" for its safety and effectiveness would have been established through clinical trials and medical assessments related to migraine frequency, intensity, and duration, as well as adverse events. The specific methodologies (e.g., patient-reported outcomes, physician diagnosis, headache diaries) are not detailed in this 510(k) summary but would have been part of the original De Novo or 510(k) submission for the predicate. For this modified device, the "ground truth" is its equivalence to the predicate device's established performance based on identical stimulation parameters and a risk analysis of the changes.

    8. The sample size for the training set

    Not applicable, as this is a physical medical device, not an AI/ML algorithm that requires a "training set."

    9. How the ground truth for the training set was established

    Not applicable, as this is a physical medical device.

    Ask a Question

    Ask a specific question about this device

    K Number
    DEN120019

    Validate with FDA (Live)

    Device Name
    CEFALY
    Manufacturer
    Date Cleared
    2014-03-11

    (453 days)

    Product Code
    Regulation Number
    882.5891
    Reference & Predicate Devices
    N/A
    Predicate For
    N/A
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The Cefaly device is indicated for the prophylactic treatment of episodic migraine in patients 18 years of age or older.

    Device Description

    The Cefaly device is a transcutaneous electrical nerve stimulator (TENS) that is applied to the forehead (Fig. 1A) using a self-adhesive electrode positioned over the upper branches of the trigeminal nerve bilaterally (Fig. 1B). It is intended to stimulate the upper branches of the trigeminal nerve in order to reduce the frequency of migraine attacks.

    The Cefaly device consists of two distinct components: an electrical pulse generator (EPG) and a self-adhesive electrode (Fig. 1). The Cefaly EPG (Fig. 1A) is made of ABS plastic and consists of electrical circuits controlled by firmware and powered by two 1.5V batteries. The front of the Cefaly EPG has a single button that is used to turn the device on/off and also to adjust the intensity of the electrical stimulus during a treatment session. Visual and auditory indicators inform the user when the device is on vs. off and help them troubleshoot if it is not working properly (e.g., device indicates if batteries need replacing and if electrical connection between device and skin is unacceptable). The back of the Cefaly EPG has two metal blades that serve to electrically connect it to the Cefaly electrode.

    The Cefaly electrode (Fig. 1B) consists of a patient-contacting layer of gel, a layer of silvercoated carbon, and a layer of cotton. An ABS plastic pin in the middle of the electrode fits securely inside a receptacle in the back of the Cefaly EPG in order to maintain a secure electrical connection during a treatment session. The Cefaly electrode is meant to be used only with the Cefaly EPG, and vice versa. It can be reused a maximum of 20 times.

    A treatment session begins by attaching the Cefaly electrode to the middle of the forehead and attaching the Cefaly EPG to the electrode. When the on/off button is depressed, a pulsatile electrical stimulus is applied for 20 minutes. During the first 14 minutes, the intensity of the stimulus gradually increases until it reaches a maximum. At any time while the stimulus intensity is increasing, the user can press the button on the front of the device to select an intensity that is lower than the maximum, and it will remain constant at this lower value for the remainder of the treatment session. The device turns the stimulus off automatically after 20 minutes, or alternatively, the user can stop a treatment session by pressing the button twice or simply removing the device from their forehead.

    AI/ML Overview

    The Cefaly device is indicated for the prophylactic treatment of episodic migraine in patients 18 years of age or older. The acceptance criteria and the study that proves the device meets them are described below.


    1. Table of Acceptance Criteria and Reported Device Performance

    The Cefaly device's acceptance criteria are derived from the clinical performance data demonstrating its safety and effectiveness. The study primarily evaluated two co-primary endpoints and several secondary endpoints.

    Acceptance Criteria (Derived from Study 1 Results)Reported Device Performance (Study 1)
    Primary Endpoints:
    1. Statistically significant responder rate (≥50% reduction in monthly migraine days) vs. sham.38.2% (Verum) vs. 12.1% (Sham) (p=0.023). Meets Criteria.
    2. Statistically significant reduction in monthly migraine days vs. sham.Verum: -2.06 days; Sham: -0.32 days. Comparison between groups was not statistically significant (p=0.08 for ITT population). Does Not Fully Meet Criteria (for direct comparison).
    Secondary Endpoints (demonstrating probable benefit):
    1. Statistically significant reduction in monthly acute anti-migraine drug intake vs. sham.Verum: 36.6% reduction; Sham: 0.5% reduction. Statistically significant (p=0.0072). Meets Criteria.
    2. Improvement in monthly migraine attack frequency.Verum: 18.8% reduction; Sham: 3.5% reduction. (p=0.044 for ITT comparison). Meets Criteria.
    3. Improvement in total headache days.Verum: 32.7% reduction; Sham: 4.1% reduction. (p=0.041 for ITT comparison). Meets Criteria.
    4. User satisfaction (at least moderately satisfied).Verum: 70.6% (very or moderately satisfied); Sham: 39% (very or moderately satisfied). Meets Criteria.
    Safety Endpoints:
    1. No serious adverse events.No serious adverse events reported. Meets Criteria.
    2. Minor, reversible adverse events.One subject reported headache causing withdrawal. No adverse device events or unanticipated device reports. Meets Criteria.

    2. Sample Size and Data Provenance for the Test Set

    Study Name: PREvention of MIgraine using the STS CEfaly (PREMICE study)

    • Sample Size:
      • Intent-to-treat (ITT) population: 67 subjects (34 in Verum group, 33 in Sham group).
      • Per protocol population: 59 subjects (30 in Verum group, 29 in Sham group).
    • Data Provenance: Prospective, multicenter, double-blinded, randomized, and sham-controlled trial conducted in 5 Belgian tertiary headache clinics.

    3. Number of Experts and Qualifications for Ground Truth

    The study relied on patient-reported outcomes collected through diaries, which served as the primary data for evaluating the efficacy of the device.

    • Ground Truth Establishment: Clinical diagnosis of migraine and headache characteristics (occurrence, severity, aura, associated symptoms, and acute drug intake) were based on International Classification of Headache Disorders (ICHD-II) criteria. While not explicitly stated as "experts establishing ground truth for a test set" in the traditional sense of image interpretation or pathology, the ICHD-II criteria are established by a consensus of headache experts and applied by trained medical professionals (neurologists/headache specialists) within the participating tertiary headache clinics for patient inclusion, exclusion, and outcome assessment. The study was run by members of the Belgian Headache Society.

    4. Adjudication Method for the Test Set

    The study design itself acted as an adjudication method. It was a double-blinded, randomized, sham-controlled trial.

    • Blinding: Both subjects and investigators were blinded to whether the device was delivering 'verum' (active) or 'sham' stimulation.
    • Data Collection: Subjects filled in diaries to record headache occurrences and severity, and these diary entries formed the basis of the outcome measures.
    • Statistical Analysis: Statistical analysis was carried out on an intent-to-treat basis, with missing data handled using the "last value carried forward" method.

    5. Multi-Reader Multi-Case (MRMC) Comparative Effectiveness Study

    No, a Multi-Reader Multi-Case (MRMC) comparative effectiveness study was not done. The study evaluated the device's effectiveness in patients directly, not by comparing human reader performance with and without AI assistance, as the Cefaly device is a therapeutic stimulation device, not a diagnostic imaging AI tool.


    6. Standalone Performance Study

    Yes, the PREMICE study (Study 1) can be considered a standalone performance study in the context of device efficacy. It directly measured the effectiveness of the Cefaly algorithm (the specific electrical stimulation parameters) acting on the patient's trigeminal nerve, without active human intervention during the treatment session. The "algorithm" here refers to the pre-programmed electrical output characteristics of the Cefaly device (pulse width, frequency, maximum intensity).

    • Algorithm Only: The device delivers an electrical stimulus based on its pre-set parameters. The study compared the effects of the active device's electrical output (verum) against a "sham" device with different, less effective electrical output parameters. Therefore, the performance demonstrated is the standalone effect of the device's programmed electrical stimulation.

    7. Type of Ground Truth Used

    The ground truth used was expert diagnosis and patient-reported outcomes, adhering to established clinical criteria:

    • Clinical Diagnosis: Migraine diagnosis (with or without aura) for subject inclusion and exclusion was based on International Classification of Headache Disorders (ICHD-II) criteria, applied by neurologists/headache specialists.
    • Patient Diaries: Subjects' daily entries in diaries regarding headache occurrence, severity (4-point scale), presence of aura, associated symptoms, and acute antimigraine drug intake served as the direct "ground truth" for the outcome measures.

    8. Sample Size for the Training Set

    This question is not applicable in the typical sense for this device. The Cefaly device is a transcutaneous electrical nerve stimulator, not a machine learning algorithm that is "trained" on a dataset in the way an AI diagnostic tool would be.

    • The electrical stimulation parameters (e.g., waveform, frequency, intensity) are pre-programmed based on physiological principles of nerve stimulation and prior research/development, not derived from a dedicated "training set" of patient data in an iterative learning process.
    • The "training" data for the device's design would effectively be the physiological and neurological understanding that informed its engineering, as well as potentially earlier pilot studies or device iterations, but not a formally collected "training set" in the context of AI/ML.

    9. How the Ground Truth for the Training Set Was Established

    As noted above, this question is not directly applicable to a pre-programmed TENS device.

    • The "ground truth" for the device's design and mechanism of action is based on neurophysiological understanding of trigeminal nerve stimulation and its role in migraine pathophysiology.
    • The selection of specific electrical parameters (pulse width, frequency, intensity) would be informed by:
      • Literature review on effective neuromodulation techniques.
      • Pre-clinical studies (e.g., in vitro, animal models).
      • Pilot human studies to determine tolerable and potentially efficacious stimulation parameters.
      • Engineering principles to ensure safe and effective energy delivery.
        However, these are part of the device's development process, not a "training set" with established ground truth as understood in AI/ML validation.
    Ask a Question

    Ask a specific question about this device

    Page 1 of 1