Search Filters

Search Results

Found 3 results

510(k) Data Aggregation

    K Number
    K151222

    Validate with FDA (Live)

    Manufacturer
    Date Cleared
    2015-05-22

    (15 days)

    Product Code
    Regulation Number
    878.4400
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The disposable cautery tip cleaner is a single use sterile device intended to be used as an electrosurgical accessory to remove eschar buildup from the tips of electrosurgical cauterization blades during surgical procedures.

    Device Description

    The disposable cautery tip cleaner is a 50mm by 50mm small foam pad with an abrasive surface, and adhesive back layer, which are used to aid in the removal of eschar on electrosurgical blades during surgical procedures. The abrasive surface is made from aluminum oxide 'gravel', with a polyurethane foam pad and polyurethane adhesive layer containing a barium monofilament for x-ray detection. The adhesive back allows for universal placement and keeps the device in place while the tip of the electrosurgical cauterization device is scratched on the abrasive surface to remove eschar buildup. The product does not come in contact with the patient, is provided sterile and is single-use.

    AI/ML Overview

    The document discusses the Key Surgical® Cautery Tip Cleaner and its substantial equivalence to a predicate device. It addresses performance data primarily for sterility, functional aspects, and packaging, rather than diagnostic accuracy or AI assistance.

    Here's a breakdown of the requested information based on the provided text:

    1. A table of acceptance criteria and the reported device performance

    RequirementSpecificationReported Performance
    SterilitySAL 10-6Pass
    Functional RequirementsProduct adhesive backing must be easily removedPass
    Packaging (Vacuum leak test)ISO 11607, ASTMF 1980Pass
    Packaging (Dye penetration test)ASTMF 1929, ASTMF 1980Pass
    Packaging (Agar contact-attack test)ISO 11607, ASTMF 1980Pass
    Packaging (Tensile seal strength test)ASTMF 88, ASTMF 1980Pass
    Packaging (Accelerated aging test)ASTMF 1980, ISO 11737Pass

    2. Sample size used for the test set and the data provenance (e.g. country of origin of the data, retrospective or prospective)

    The document does not specify the sample sizes used for each test or the data provenance (country of origin, retrospective/prospective). The tests listed are for device manufacturing and packaging quality, not for clinical performance on patients directly.

    3. Number of experts used to establish the ground truth for the test set and the qualifications of those experts

    Not applicable. The tests performed are engineering and manufacturing quality control tests (e.g., sterility, adhesive function, packaging integrity), not clinical studies requiring expert interpretation of results to establish ground truth for a diagnostic or AI-assisted device.

    4. Adjudication method (e.g. 2+1, 3+1, none) for the test set

    Not applicable. Adjudication methods are typically relevant for clinical studies where multiple experts evaluate cases and discrepancies need to be resolved. This document describes tests for product quality where results are determined by standardized methods.

    5. If a multi-reader multi-case (MRMC) comparative effectiveness study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance

    Not applicable. The device is a "Cautery Tip Cleaner," a physical accessory for surgical tools, not a diagnostic imaging device or an AI-assisted tool requiring human interpretation. Therefore, an MRMC study comparing human readers with and without AI assistance is not relevant to this device.

    6. If a standalone (i.e. algorithm only without human-in-the-loop performance) was done

    Not applicable. This device is not an algorithm or software; it is a physical medical accessory.

    7. The type of ground truth used (expert consensus, pathology, outcomes data, etc.)

    The "ground truth" for the tests described are the established specifications and methods outlined in recognized standards (e.g., ISO 11137-2, ISO 11607, ASTM F series). For example:

    • Sterility: Ground truth is defined by the SAL 10-6 specification, confirmed using ISO 11137-2 methods.
    • Functional (adhesive removal): Ground truth is the observable characteristic of being "easily removed," likely assessed against internal engineering standards.
    • Packaging: Ground truth is the successful adherence to specific physical properties and integrity tests as defined by the cited ISO and ASTM standards.

    8. The sample size for the training set

    Not applicable. This device does not involve machine learning or AI, and therefore does not have a "training set."

    9. How the ground truth for the training set was established

    Not applicable. Since there is no training set, there is no ground truth to establish for it.

    Ask a Question

    Ask a specific question about this device

    K Number
    K053433

    Validate with FDA (Live)

    Date Cleared
    2006-01-19

    (41 days)

    Product Code
    Regulation Number
    878.4400
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The disposable Cautery Tip Cleaner is a single use sterile product. Its intended use is as an electrosurgical accessory to clean uncoated cautery blades that are part of an electrosurgical pencil. The cautery blade is "scratched" on the cautery tip cleaner to remove eschar build-up during surgical procedures to allow the cautery blade to function effectively throughout the procedure. The product is usually placed somewhere on the sterile field, typically on the mayo stand. This product does not come in contact with the patient.

    Device Description

    The disposable Cautery Tip Cleaner is a small 2" x 2" square polyurethane foam pad which features a textile abrasive layer with an adhesive backing. A radiopaque strip within the adhesive makes the device x-ray detectable. The adhesive backing allows for universal placement as well as allowing the device to remain in place while the tip of the electrosurgical cauterization device is "scratched" on the abrasive surface to remove eschar buildup.

    AI/ML Overview

    The provided text is a 510(k) summary for a Cautery Tip Cleaner and does not contain information about acceptance criteria or a study proving that the device meets those criteria. The document focuses on the device description, intended use, technological characteristics comparison to a predicate device, and the FDA's determination of substantial equivalence.

    Therefore, I cannot provide the requested information from the given text.

    Ask a Question

    Ask a specific question about this device

    K Number
    K030339

    Validate with FDA (Live)

    Date Cleared
    2003-03-07

    (35 days)

    Product Code
    Regulation Number
    878.4400
    Age Range
    All
    Reference & Predicate Devices
    N/A
    Predicate For
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The disposable Cautery Tip Cleaner is a single use sterile product. It is intended to be used as an electrosurgical accessory. The Cautery Tip Cleaner provides a method of removing eschar build-up from the tip of electro surgical instruments during the course of a surgical procedure.

    Device Description

    Not Found

    AI/ML Overview

    This is a premarket notification for an Electro-Cautery Tip Cleaner, a device designed to remove eschar build-up from electrosurgical instruments. The FDA has determined it is substantially equivalent to legally marketed predicate devices. Unfortunately, the provided document does not contain any information regarding specific acceptance criteria, performance data, or a study report for this device.

    Therefore, I cannot provide the detailed information requested regarding the acceptance criteria and the study proving the device meets them. The document focuses on the regulatory approval process and not on the performance testing of the device itself.

    Ask a Question

    Ask a specific question about this device

    Page 1 of 1