    VisiPlugST provide temporary occlusion of the tear drainage system. VisiPlugST may be used as a diagnostic aid to determine the potential effectiveness of long-term occlusion, to temporarily enhance the efficacy of topical medication or ocular lubricants, after surgery to prevent complications due to dry eyes, to evaluate treatment of ocular dryness secondary to contact lens use, and to evaluate the dry eye component of ocular surface diseases (OSD).

    Device Description

    The proposed device is an ophthalmic device commonly referred to as a punctum plug. It is designed to be placed by a practitioner into the horizontal canaliculus to restrict the natural lubricating tears from being pumped off the eye.

    VisiPlugST provides temporary occlusion of the tear drainage system. The device may be used as a diagnostic aid to determine the potential effectiveness of long-term occlusion, to temporarily enhance the efficacy of topical medications or ocular lubricants, after surgery to prevent complications due to dry eyes, to evaluate treatment of ocular dryness secondary to contact lens use, and to evaluate the dry eye component of ocular surface diseases (OSD).

    VisiPlugST plugs are cylindrical in shape, approximately 1.75-2.00mm in length, and available in three sizes: 0.3mm, 0.4mm and 0.5mm. Each plug is cut from a monofilament strand of Glycoprene® MG23, a synthetic surgical grade polymer composed of poly(glycolide-co-trimethylene carbonate-co-caprolactone). The monofilament is dyed with an approved color additive, Green D & C 6 (CAS# 128-80-3; 0.1% by weight). Titanium dioxide is added to the polymer to make the plugs opaque, providing a satisfactory means with which to determine the plug's presence or absence following insertion by a practitioner.

    AI/ML Overview

    The VisiPlugST is a punctum plug designed for temporary occlusion of the tear drainage system.

    1. Acceptance Criteria and Reported Device Performance

    The acceptance criteria for the VisiPlugST were based on comparing its material properties to an existing predicate device (Collagen Plugs for the Lacrimal Efficiency Test, K895342) and referenced predicate devices (Maxon, Sterile Synthetic Absorbable Sutures K990951 and CaproSyn Suture K032586). The primary performance characteristics evaluated were strength retention and mass loss degradation rates.

    Performance MetricPredicate Device (Gut Suture) PerformanceAcceptance Criteria (Implicit: Substantial Equivalence to Predicate)Reported VisiPlugST Performance (Glycoprene® MG23)Conclusion
    Strength Retention Rate (at 3-5 days)40% strength retention at 3 daysSimilar strength retention profile40% strength retention at 4-5 daysMeets
    Mass Loss Profile (at 30 days)45% mass lossSimilar mass loss profile46% mass lossMeets
    BiocompatibilitySafeSafeSafeMeets

    2. Sample Size and Data Provenance

    The document does not explicitly state a separate "test set" and a "training set" in the context of an algorithm or image analysis. The data provided refers to nonclinical tests conducted to assess the material properties of the VisiPlugST (Glycoprene® MG23) against its predicate device (gut suture).

    • Sample Size for Test Set: Not explicitly stated for each test, but studies were conducted to compare strength and mass loss degradation rates.
    • Data Provenance: The studies were nonclinical tests comparing material properties. The country of origin and whether it was retrospective or prospective is not specified, but it refers to laboratory testing of materials.

    3. Number of Experts and Qualifications for Ground Truth Establishment

    This device is not an AI/ML device that requires expert review for ground truth establishment. The performance data is based on laboratory physical and chemical testing of the device material.

    4. Adjudication Method for Test Set

    Not applicable as this is not a diagnostic device requiring human reader adjudication.

    5. Multi-Reader Multi-Case (MRMC) Comparative Effectiveness Study

    Not applicable. This is not an AI-assisted diagnostic device.

    6. Standalone (Algorithm Only Without Human-in-the-Loop Performance) Study

    Not applicable. This is a physical medical device, not an algorithm.

    7. Type of Ground Truth Used

    The "ground truth" for the nonclinical tests was established through laboratory measurements and scientific analysis of the material properties (strength retention, mass loss) and biocompatibility of the Glycoprene® MG23 material, compared against established values and properties of the predicate device's material (gut suture).

    8. Sample Size for the Training Set

    Not applicable, as this device does not involve a "training set" in the context of an algorithm.

    9. How the Ground Truth for the Training Set Was Established

    Not applicable.