    K984136

    Validate with FDA (Live)

    Manufacturer
    Date Cleared
    1999-02-16

    (90 days)

    Product Code
    Regulation Number
    876.5130
    Age Range
    All
    Reference & Predicate Devices
    N/A
    Predicate For
    N/A
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The Bardex® Lubri-Sil™ I.C. Foley Catheter is indicated for use in the drainage and/or collection and/or measurement of urine. Generally, drainage is accomplished by inserting the catheter through the urethra and into the bladder. However, drainage is sometimes accomplished by suprapubic or other placement of the catheter, such as a nephrostomy tract.

    Some Foley catheters, especially those with larger (30cc) balloons are used to assist in hemostasis following surgery such as transurethral resection of the prostate.

    Device Description

    The Bardex® Lubri-Sil™ I.C. Foley Catheter is a two-way all-silicone Foley catheter with silver and lubricious hydrophilic coatings.

    The Bard Lubri-Sil I. C. Foley Catheter is constructed of high grade extruded clear silicone rubber with a molded tip and funnel. It is a twolumen catheter with a drainage lumen and an inflation lumen with two-way valve. A silver coating and then a hydrophilic polymeric coating are applied to the finished catheter. The hydrophilic coating becomes very slippery when wet. The silver coating discourages bacterial adhesion to the catheter surface. The Lubri-Sil I.C. Foley Catheter is available in even shaft sizes 12-24 Fr. with a 5cc balloon and in even shaft sizes 16-24 Fr. with a 30cc balloon.

    AI/ML Overview

    I am unable to answer your request with the provided information. The text describes a medical device, the Bardex® Lubri-Sil™ I.C. Foley Catheter, its intended use, technological characteristics, and performance data. It also includes an FDA 510(k) clearance letter.

    However, the provided text does not contain the specific details required to complete the table and answer all the questions in your prompt, particularly regarding "acceptance criteria" versus "performance requirements," sample sizes for test/training sets, data provenance, expert qualifications, adjudication methods, MRMC studies, or how ground truth was established if it were a diagnostic AI device.

    The document details performance requirements and states the device "meets" them, but these are not explicitly presented as "acceptance criteria" with numerical targets and reported device performance values in a comparative table as requested. It also describes "performance data" and "testing" but lacks the granular information about study design, sample sizes, and ground truth establishment typically associated with the type of request you've made for an AI/diagnostic device.

    The provided document describes a Foley Catheter, which is a physical medical device for drainage, not a diagnostic AI device that would typically have "test sets," "training sets," "ground truth," "experts," or "MRMC studies" in the context you've outlined.

    Therefore, to answer your request accurately, I would need a different type of document that describes the acceptance criteria and study detailed for a diagnostic AI device, rather than a physical medical device like a Foley Catheter.

    Ask a Question

    Ask a specific question about this device

    Page 1 of 1