Search Filters

Search Results

Found 1 results

510(k) Data Aggregation

    K Number
    K172079

    Validate with FDA (Live)

    Device Name
    Avail
    Date Cleared
    2017-10-19

    (101 days)

    Product Code
    Regulation Number
    882.5890
    Reference & Predicate Devices
    Predicate For
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The Avail is intended for the relief of pain associated with sore or aching muscles of the lower back, arms, legs, shoulders or feet due to strain from exercise or normal household work activities.

    When used for the symptomatic relief and management of chronic, intractable pain and relief of pain associated with arthritis, use the Tap, Shoulder, Arm or Leg mode of stimulation.

    Environments of Use: Clinics, hospital and home environments
    Patient Population: Adult

    Device Description

    The Avail device is a wireless, independent dual channel wearable electrotherapy device that is designed to alleviate chronic muscle and joint pain on multiple body locations. It delivers TENS (Transcutaneous Electrical Nerve Stimulation) technology and microcurrent therapy through the simple, convenient use of the dedicated Omron TENS iOS or Android App. Reusable, self-adhesive, contouring pads allow for discreet and convenient placement on multiple pain locations on the body. The Avail system can be programmed to deliver nine different TENS modes and a microcurrent therapy mode.

    The system contains two main TENS units which are rechargeable and each can be attached to either a medium or large size gel pad. The pad with attached TENS unit can then be applied to intact skin at the desired location for therapy and pain relief. Control of the Avail TENS system is completed through the available Omron TENS App. The Avail will be packaged with an Instruction Manual which provides details on setting up the device for use, installing of the Omron TENS App, setting and controlling therapy modes, and troubleshooting. The system includes two main TENS units, medium and large pads, an AC-powered charger, AC adapter, a pad holder and storage case.

    AI/ML Overview

    The Omron Avail (Model PM601) is a Transcutaneous Electrical Nerve Stimulator (TENS) device intended for pain relief.

    Here's an analysis of the acceptance criteria and the study that proves the device meets them, based on the provided FDA 510(k) submission:

    1. Table of Acceptance Criteria and Reported Device Performance

    The acceptance criteria are primarily defined by the features and performance of the predicate and reference devices, as the submission aims to demonstrate substantial equivalence. The reported device performance is then compared against these.

    Feature / Acceptance Criteria CategoryAcceptance Criteria (from predicate/reference)Reported Device Performance (Omron Avail PM601)
    Classification- Regulation: 21 CFR §882.5890 (Transcutaneous electrical nerve stimulator for pain relief) - Product Code: Primary: NUH, Secondary: NYN, NGX (for predicate)- Regulation: 21 CFR §882.5890 - Product Code: Primary: NUH, Secondary: NYN
    Indications for Use- Temporary relief of pain associated with sore and aching muscles due to strain from exercise or normal household/work activities (PulseRelief, Omron Heat Pain Pro, Painmaster MCT Patch). - Symptomatic relief and management of chronic, intractable pain and relief of pain associated with arthritis (SmartRelief).- Relief of pain associated with sore or aching muscles of the lower back, arms, legs, shoulders or feet due to strain from exercise or normal household work activities. - Symptomatic relief and management of chronic, intractable pain and relief of pain associated with arthritis (using Tap, Shoulder, Arm or Leg mode).
    Environment of UseClinics, hospital, and home environments (Omron Heat Pain Pro); Home (PulseRelief, Painmaster MCT Patch).Clinics, hospital and home environments.
    Patient PopulationAdults (all comparing devices); Over 12 years of age unless under physician supervision (Painmaster MCT Patch).Adults.
    ContraindicationsSimilar contraindications regarding pacemakers, implanted defibrillators, other implanted electronic/metallic devices (all comparing devices). Avoid placement along neck/through head for Painmaster.Do not use if you have a cardiac pacemaker, implanted defibrillator, or other implanted metallic or electronic device.
    Power SourceRechargeable Lithium-ion battery (PulseRelief, Omron Heat Pain Pro); 3V CR2032 lithium battery (SmartRelief); Primary battery only, one-time use (Painmaster).Rechargeable Lithium-ion battery.
    Patient Leakage Current<10 uA (Normal Condition), <50 uA (Single Fault Condition) for PulseRelief.<10 uA (Normal Condition), <50 uA (Single Fault Condition).
    Maximum Current Density (@500Ω)TENS modes: Ranges from 0.08 to 0.44 mA/cm² r.m.s. across predicate/reference devices. Microcurrent: 0.0015 mA/cm² r.m.s. (Painmaster MCT Patch).TENS modes: 0.03 to 0.17 mA/cm² r.m.s. Microcurrent: 0.0008 mA/cm² r.m.s. (This is well below the IEC60601-2-10:2012 limit of <2mA/cm²).
    Maximum Average Power Density (@500Ω)TENS modes: Ranges from ~1.9x10⁻³ to ~2.37x10⁻³ W/cm² across predicate/reference devices. Microcurrent: 2.871E-08 W/cm² (Painmaster MCT Patch).TENS modes: 2.533E-05 to 6.769E-04 W/cm². Microcurrent: 1.398E-08 W/cm².
    Timer Range1-59 minutes and continuous (PulseRelief); 30 minutes, fixed (SmartRelief, Omron Heat Pain Pro); Up to 300 hours, not adjustable (Painmaster MCT Patch).TENS therapy: 5 to 60 minutes (in 5-minute increments). Microcurrent therapy: 30 to 180 minutes (in 30-minute increments).
    Controlling InterfaceDedicated smartphone App (PulseRelief).Dedicated Omron TENS iOS or Android App.
    Number of Output Modes15 TENS, 5 EMS (PulseRelief); 1 mode (SmartRelief); 9 TENS, 2 Heat Level (Omron Heat Pain Pro); 1 Microcurrent (Painmaster).9 TENS modes, 1 Microcurrent mode.
    Safety and EMC StandardsES 60601-1, IEC60601-1-2, IEC60601-2-10, ISO10993-5/10 (PulseRelief).ES 60601-1, IEC60601-1-2, IEC60601-2-10, IEC 60601-1-11. (Biocompatibility per ISO 10993-1).

    2. Sample Size for Test Set and Data Provenance

    • Sample Size for Test Set: Not applicable. The submission explicitly states: "Clinical testing was not performed to support this 510(k) submission." The evaluation for substantial equivalence was based on non-clinical (bench) testing, software verification and validation, electrical safety, electromagnetic compatibility (EMC), and biocompatibility testing, along with a comparison to predicate devices.
    • Data Provenance: Not applicable, as no clinical testing was performed on human subjects for this submission. The non-clinical testing results would originate from laboratory testing in a controlled environment.

    3. Number of Experts Used to Establish Ground Truth for the Test Set and Qualifications

    Not applicable. As no clinical testing was performed and the evaluation was based on non-clinical performance and comparison to predicate devices, there was no "ground truth" establishment by experts in the context of clinical outcomes or diagnostic accuracy.

    4. Adjudication Method for the Test Set

    Not applicable. Without a clinical test set requiring expert interpretation or consensus, no adjudication method was used.

    5. Multi-Reader Multi-Case (MRMC) Comparative Effectiveness Study

    No. A multi-reader multi-case (MRMC) comparative effectiveness study was not done. The submission explicitly states that clinical testing was not performed. The device is a TENS unit for pain relief, not a diagnostic imaging device that typically requires MRMC studies to assess reader performance with and without AI assistance.

    6. Standalone (Algorithm Only Without Human-in-the-Loop Performance) Study

    Not applicable in the typical sense for an AI/CADe device. This device is a hardware TENS unit controlled by an app. The "performance" being evaluated is the electrical output parameters, safety features, and usability, not a diagnostic algorithm's standalone accuracy. The device itself is the "standalone" entity in terms of delivering electrical stimulation.

    7. Type of Ground Truth Used

    The "ground truth" in this context is established through design specifications, industry standards (e.g., IEC 60601 series, ISO 10993-1), and the performance characteristics of legally marketed predicate devices.

    • Performance Verification: The device's electrical output parameters (voltage, current, pulse duration, frequency, phase charge, current density, power density) were measured and compared against established specifications and the operational ranges of predicate devices.
    • Electrical Safety & EMC: Compliance with recognized international standards (e.g., IEC 60601-1, IEC 60601-1-2, IEC 60601-2-10) serves as the ground truth for safety.
    • Biocompatibility: Testing per ISO 10993-1 established that patient-contacting materials are safe.
    • Software Verification and Validation: Ensures the software (the control app) functions as intended and meets its requirements.
    • Usability Testing: Evaluated the user interface and overall interaction with the device in a simulated home environment to ensure safe and effective use.

    8. Sample Size for the Training Set

    Not applicable. As this is a hardware medical device (TENS unit) and not an AI or machine learning algorithm requiring a "training set" of data to learn from, there is no training set in the typical computational sense.

    9. How the Ground Truth for the Training Set Was Established

    Not applicable, for the same reason as point 8.

    Ask a Question

    Ask a specific question about this device

    Page 1 of 1