Search Filters

Search Results

Found 2 results

510(k) Data Aggregation

    K Number
    K010288

    Validate with FDA (Live)

    Manufacturer
    Date Cleared
    2001-04-13

    (72 days)

    Product Code
    Regulation Number
    866.4700
    Age Range
    N/A
    Reference & Predicate Devices
    N/A
    Predicate For
    N/A
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use
    Device Description
    AI/ML Overview
    Ask a Question

    Ask a specific question about this device

    K Number
    K972200

    Validate with FDA (Live)

    Device Name
    ANEUVYSION
    Manufacturer
    Date Cleared
    1997-10-20

    (132 days)

    Product Code
    Regulation Number
    866.4700
    Age Range
    All
    Reference & Predicate Devices
    N/A
    Predicate For
    N/A
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The AneuVysion™ (CEP 18, X, Y-alpha satellite, LSI 13 and 21) Multicolor Probe Panel is intended to use CEP 18/X/Y probe to detect alpha satellite sequences in the centromere regions of chromosomes 18, X, and Y, and LSI 13/21 probe to detect the 13q14 region and the 21q22.13 to 21q22.2 region. The AneuVysion™ kit is indicated for use as an adjunct to standard cytogenetic metaphase analysis for identifying and enumerating chromosomes 13, 18, 21, X, and Y via fluorescence in situ hybridization (FISH) in metaphase cells and interphase nuclei obtained from amniotic fluid in subjects with presumed high risk pregnancies. It is not intended to be used as a stand alone assay for test reporting. FISH results are intended to be reported and interpreted only in conjunction with results of standard cytogenetic analysis, performed concurrently, utilizing the same patient specimen. FISH results should not be reported prior to standard cytogenetic results except in instances where reporting of FISH results alone is medically indicated or standard cytogenetic results are not available, e.g., culture failure. Reporting and interpretation of FISH should be consistent with professional standards of practice! This device is intended for use only with amniocyte cells; it is not intended for and has not been validated for use with other test matrices. This FISH assay will not detect the presence of structural chromosome abnormalities frequently associated with birth defects. This FISH assay will be performed in cytogenetics laboratories.

    Device Description

    The AneuVysion™ kit is a combination of two DNA probe mixtures; CEP 18/X/Y and LSI 13/21. The CEP 18/X/Y probe is a mixture of directly labeled fluorescent DNA probes specific for the D18Z1, DXZ1 and DYZ3 regions of chromosomes 18, X, and Y respectively. The LSI 13/21 probe contains a mixture of unique DNA sequences that hybridize in the 13q14 region of chromosome 13, and unique DNA sequences complementary to the D21S259, D21S341, and D21S342 loci contained within the 21q22.13 to 21q22.2 region on the long arm of chromosome 21. The LSI 13 probe was created from a set of overlapping clones which contain the entire RB-1 gene as well as regions extending beyond the gene on both sides. The probe extends beyond the 180 kb RB-1 gene for 110-170 kb in the 5' direction and approximately 120 kb in the 3' direction; the entire probe is 410-470 kb. CEP 18/X/Y is an aqua, green, and orange tri-color probe mixture and LSI 13/21 is a green and orange dual-color probe mixture.

    AI/ML Overview

    Table of Acceptance Criteria and Reported Device Performance

    Performance MetricAcceptance CriteriaReported Device Performance
    Hybridization Efficiency<2% cells with no or only one signal for each probeLSI 13, CEP 18, LSI 21: Average percentage of cells with no hybridization signal was 0.42%. CEP X/Y: Average percentage of cells with only one hybridization Y signal was 0.06%.
    Analytical Sensitivity (Limit of Detection)Not explicitly stated as a fixed acceptance criterion, but implied to be near 3% based on study results.Estimated to be 3%. 0% XO specimen: Mean 0.04% (±0.20%) X-signaled nuclei, upper 95% CI 0.43%. 10% XO specimen: Mean 9.10% (±1.79%) X-signaled nuclei, lower 95% CI 5.59%.
    Analytical SpecificityNo cross-hybridization to non-target chromosome lociNo cross-hybridization to other chromosome loci was observed in any of the 705 metaphase cells examined; hybridization was limited to the target regions of chromosomes 13, 18, 21, X, and Y.
    Reproducibility (Inter-site, inter-lot, inter-day, inter-observer)No significant variations observed in ANOVA analysis for percentage of aneuploid cells.No significant variations were observed in any of the inter-assay reproducibility parameters (inter-site, inter-lot, inter-day, inter-observer) using ANOVA. Intra-assay variability (mean, S.D., C.V.) shown in Table 1 for various mosaicism levels.
    Informativeness Rate (Per Specimen)Not explicitly stated as a fixed acceptance criterion; however, a high rate is implied for device utility.97.5% (2183/2238)
    Informativeness Rate (Per Patient)Not explicitly stated as a fixed acceptance criterion; however, a high rate is implied for device utility.99.8% (1503/1516)
    Detection of True AneuploidyDetect 100% of cases identified by standard cytogenetic analysis.Detected 99.9% (860/861) of true aneuploid cases identified by standard cytogenetic analysis (one case attributed to long storage).
    Detection of EuploidyDetect 100% of cases identified by standard cytogenetic analysis.Detected 100% (504/504) of euploid cases identified by standard cytogenetic analysis (FISH showed <10% aneuploid cells).
    Correlation of % Aneuploid Cells in Mosaic Cases (FISH vs. Standard Cytogenetics)Not explicitly stated as a fixed acceptance criterion, but a high correlation indicates good device performance.0.76
    Pseudomosaic Cases (FISH results)Show less than 10% aneuploid cells, consistent with the euploid state.FISH assay results showed less than 10% aneuploid cells, which is consistent with the euploid state, across all 76 pseudomosaic cases.
    Concordance between Cultured and Uncultured Samples (Aneuploid, Euploid, Pseudomosaic)Concordant results between cultured and uncultured samples for aneuploid, euploid, and pseudomosaic cases.The FISH test results in aneuploid, euploid and pseudomosaic cases were concordant between cultured and uncultured samples. (Note: In mosaic cases, varying % aneuploid cells between cultured and uncultured samples led to a few discordances).

    Study Details Proving Device Meets Acceptance Criteria:

    The information provided describes several studies that collectively demonstrate the performance of the AneuVysion™ kit.

    1. Sample Size used for the test set and the data provenance:

      • Analytical Specificity: 705 metaphase spreads.
      • Reproducibility (Pivotal Study): Not explicitly stated how many individual specimens, but 24 measurements were taken for each of the four specimen types (100% XY, 10% X/90% XX, 17% X/47% XX/36% XXX, 50% XY+21/50% XY). The specimens were "cultured human amniocyte specimens."
      • Methods Comparison / Clinical Specimens (Pivotal Multi-center Study):
        • Total Patients: 1516 patients.
        • Total Amniocyte Specimens: 2,238 specimens.
        • Aneuploid Cases: 861 cases.
        • Mosaic Cases: 62 cases.
        • Pseudomosaic Cases: 76 cases.
        • Euploid Cases: 504 cases.
        • Pairwise Comparison (Cultured vs. Uncultured): 722 patients.
      • Data Provenance: The studies were conducted at "Thirty one investigation sites" in a "multi-center, blinded, controlled, comparative study." The specimens were "human amniotic fluid specimens obtained from a total of 1516 patients." The origin seems to be implicitly from the countries where these investigation sites are located, likely including the USA given the FDA submission. The study is prospective in nature as it involved collecting and analyzing patient samples for the purpose of the study.
    2. Number of experts used to establish the ground truth for the test set and the qualifications of those experts:

      • The ground truth for the clinical specimens was established by "standard cytogenetic analysis." While the document doesn't explicitly state the number of experts, cytogenetic analysis is a specialized field, and it's implied that qualified cytogeneticists performed this analysis at each of the "Thirty one investigation sites." The qualifications would inherently be those required to perform and interpret standard cytogenetic metaphase analysis.
    3. Adjudication method for the test set:

      • The document states that the "results of interphase FISH analysis were compared to standard cytogenetics." Standard cytogenetic analysis served as the gold standard. There is no mention of a specific adjudication method (like 2+1 or 3+1 consensus) for discrepancies between FISH and cytogenetics; rather, standard cytogenetics was the reference.
    4. If a multi-reader multi-case (MRMC) comparative effectiveness study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance:

      • This is not an AI-based device. It is a DNA probe kit (FISH assay) for manual interpretation by human cytogeneticists. Therefore, an MRMC study comparing human readers with and without AI assistance is not applicable and was not performed.
    5. If a standalone (i.e. algorithm only without human-in-the-loop performance) was done:

      • No. The AneuVysion™ kit "is not intended to be used as a stand alone assay for test reporting." FISH results are "intended to be reported and interpreted only in conjunction with results of standard cytogenetic analysis, performed concurrently, utilizing the same patient specimen." The device is a diagnostic reagent, requiring human interpretation of the hybridization signals on cells.
    6. The type of ground truth used:

      • The primary ground truth used for the clinical validation was standard cytogenetic analysis (karyotyping of metaphase spreads). This is widely considered the gold standard for detecting chromosomal abnormalities.
    7. The sample size for the training set:

      • The document does not explicitly describe a separate "training set" for the AneuVysion™ kit. As this is a probe-based assay that relies on established biological principles of hybridization and is interpreted by human experts, there isn't a machine learning algorithm that requires a traditional training set. The various studies on hybridization efficiency, analytical sensitivity/specificity, and reproducibility likely served to establish and refine the assay's performance characteristics rather than "train" an algorithm.
    8. How the ground truth for the training set was established:

      • See point 7. Since a traditional training set for an algorithm is not applicable, the concept of establishing ground truth for it is also not applicable in the context of this device. The performance characteristics were established via validation studies using reference methods (like G-banding for specificity and standard cytogenetics for clinical concordance).
    Ask a Question

    Ask a specific question about this device

    Page 1 of 1