Search Filters

Search Results

Found 1 results

510(k) Data Aggregation

    K Number
    K960550

    Validate with FDA (Live)

    Device Name
    ACTIVE T3 RIA
    Date Cleared
    1996-03-06

    (27 days)

    Product Code
    Regulation Number
    862.1710
    Age Range
    All
    Reference & Predicate Devices
    N/A
    Predicate For
    N/A
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The DSL ACTIVE™ T3 RIA assay is intended for the quantitative determination of Total T3 in human serum. The measurement of T3 is used in the diagnosis and treatment og thyroid diseases such as hyperthyroidism.

    Device Description

    The DSL ACTIVE™ T3 RIA kit was developed for the quantitative measurement of Total T3 in human serum. The RIA format is a competitive binding protein assay. Radiolabeled T3 competes with un-labeled T3 in the serum sample for binding sites to the antibody. Separation of free from bound T3 is achieved by decanting the coated tubes after incubation. The resultant is analyzed in a gamma counter for bounds counts per minute. The amount of radio-labeled T3 bound to the antibody is inversely proportional to the concentration of the T3 present in the sample.

    AI/ML Overview

    The provided text is a summary of safety and effectiveness for a diagnostic device, the DSL 3100 ACTIVE™ T3 RIA Kit. It describes the device's purpose, mechanism, and states its substantial equivalence to another device, the DPC COAT-A-COUNT TOTAL T3 RIA.

    However, the text does not contain any information about acceptance criteria, a study proving device adherence to these criteria, sample sizes for test or training sets, data provenance, expert ground truth establishment, adjudication methods, MRMC studies, standalone performance, or the type of ground truth used.

    The only "study" mentioned is a comparison study to demonstrate substantial equivalence, which is described as follows:

    Comparison Study Information (from the provided text):

    • Objective: To demonstrate substantial equivalence between the DSL ACTIVE™ T3 RIA and the DPC COAT-A-COUNT TOTAL T3 RIA.
    • Sample Size: n=30 patient samples.
    • Sample Selection: Samples were chosen based on expected T3 levels (low, intermediate, and high).
    • Method: Assayed using both methods.
    • Results: Linear regression analysis yielded the equation Y = 1.09(X) + -8.8 with a correlation coefficient (r) = 0.90. (Where Y is likely the DSL ACTIVE™ T3 RIA result and X is the DPC COAT-A-COUNT TOTAL T3 RIA result, although this is not explicitly stated).

    Based on the provided text, I cannot complete the requested table and information, as it is largely absent from the document. The document focuses on regulatory submission details and a short equivalence study, not detailed performance criteria or AI-specific development.

    Ask a Question

    Ask a specific question about this device

    Page 1 of 1