    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The ImagingRing m is a mobile x-ray system to be used for 2D planar and fluoroscopic and 3D imaging for adult and pediatric patients. It is intended to be used where 2D and 3D information of anatomic structures such as bony anatomy and soft tissue and objects with high X-ray attenuation such as (metallic) implants is required. The ImagingRing m provides an interface that can be used by system integrators for integration of the ImagingRing m with image guidance systems such as surgical navigation systems.

    Device Description

    The ImagingRing m (Version 2.0) is from a technical point of view the same system as its already approved predecessor ImagingRing m (K203281). The only difference is the implementation of a new x-ray source in combination with a software upgrade, which allows for higher power settings. The ImagingRing m functions as a mobile x-ray system to be used for 2D planar and fluoroscopic and 3D imaging for adult and pediatric patients. It is intended to be used where 2D and 3D information of anatomic structures such as bony anatomy and soft tissue and objects with high X-ray attenuation such as (metallic) implants is required. The ImagingRing m (Version 2.0) provides an interface that can be used by system integration of the ImagingRing m (Version 2.0) with image guidance systems such as surgical navigation systems.

    The ImagingRing m (Version 2.0) consists of the ring gantry and respective arms carrying the X-Ray source and directly integrates all necessary electronic and components along with low-level software to realize coordinated motion and X-ray emission in the device's ring carrier and legs. The ImagingRing m (Version 2.0) device also provides a detachable Remote Control Panel (RCP) component that provides a display and controls elements such that users can interact with the machine.

    AI/ML Overview

    This document is a 510(k) Summary for the medPhoton GmbH ImagingRing m (Version 2.0), Loop-X (Version 2.0), and Loop-X Mobile Imaging Robot (Version 2.0). It focuses on demonstrating substantial equivalence to a predicate device, K203281 (ImagingRing m). The provided text describes the changes in the new version (primarily a new X-ray source allowing higher power settings and associated software upgrades) and the testing conducted to support its safety and effectiveness.

    Here's an analysis of the acceptance criteria and the study as per your request, based only on the provided text:

    Important Note: The provided text is a 510(k) Summary, which is a high-level overview. It does not contain detailed acceptance criteria tables, specific statistical results from performance studies, or granular details about ground truth establishment and expert qualifications often found in a full study report or 510(k) submission. Therefore, some information requested might not be explicitly present and can only be inferred or stated as 'not provided'.


    Acceptance Criteria and Study Details

    The document states that the testing aimed to evaluate whether the new features (increased kVp, infrared motion compensation, extended Field of View) negatively impact diagnostic accuracy and usability, and to confirm that they provide benefits without altering total radiation dose or degrading image clarity.

    Given the nature of a 510(k) submission and the information provided, the "acceptance criteria" are implied to be that the new device's performance, particularly in terms of image quality and diagnostic utility, is non-inferior or superior to the predicate device, especially considering the new features. Specific quantitative acceptance criteria (e.g., minimum SNR, maximum artifacts) are not explicitly listed in the summary.

    Here's what can be extracted and inferred:

    1. Table of Acceptance Criteria and Reported Device Performance

    Acceptance Criterion (Implied)Reported Device Performance
    Image Quality at Higher kVp (140 kVp vs. 120 kVp): Diagnostic accuracy and usability should not be negatively impacted."Cadaver studies compared 3DCBCT images acquired at 120 kVp, demonstrating that the increased tube voltage does not negatively impact image quality. Instead, higher penetration particularly for larger patients or cases involving metallic implants." This indicates non-inferiority in image quality and superiority in penetration for certain cases, meeting the implied criterion.
    Effectiveness of Infrared-Based Motion Compensation: Reduction of motion-related artifacts; no alteration of total radiation dose."It was confirmed that this feature improves image quality without altering total radiation dose. This finding is particularly relevant in cases where respiratory motion or involuntary patient movement could otherwise degrade image clarity." This indicates improvement in image quality (artifact reduction) without increased dose, meeting the implied criterion.
    Extended Field of View (FOV) Techniques (Longitudinally extended 3D imaging and 2D topogram scanning): Enhanced anatomical coverage, improved workflow efficiency, maintenance of high image quality, and adherence to radiation principles."It was demonstrated that extended FOV scanning enhances workflow efficiency while maintaining high image quality and adhering to radiation principles." This indicates enhanced workflow and maintained image quality/radiation principles, meeting the implied criterion.
    Overall Clinical Performance / Substantial Equivalence: New features should not negatively impact overall clinical performance."Across all evaluated features, clinical and non-clinical evaluations introduced in the subject device do not negatively impact its clinical performance. Instead, enhancements such as higher X-ray energy, motion compensation, and extended FOV capabilities provide tangible benefits in patient imaging, these non-clinical imaging studies, through the comparison of image quality, artifacts, anatomical representation, and dose, demonstrate the substantial equivalence of the devices with the tested new features to their respective base versions or similar devices." This is the overarching conclusion of the substantial equivalence claim.

    2. Sample Sizes Used for the Test Set and Data Provenance

    • Test Set Sample Sizes: Not explicitly stated with specific numbers of cases or subjects. The text mentions "cadaver studies" and "clinical studies involved patient imaging."
    • Data Provenance:
      • Country of Origin: "Cadaver studies (e.g. at Highridge Cadaver Lab in the US, Paracelsus Medical University (PMU) in Salzburg, Austria)." This indicates data from both the US and Austria. "Evaluations at reference customer sites" suggests other clinical sites, but specific locations are not given.
      • Retrospective or Prospective: Not explicitly stated. "Clinical studies involved patient imaging under standard operating conditions to validate the new features' impact in routine diagnostic settings" suggests a prospective approach for the clinical portion, while cadaver studies are inherently prospective for the device testing.

    3. Number of Experts Used to Establish Ground Truth for the Test Set and Qualifications

    • Number of Experts: Not explicitly stated.
    • Qualifications of Experts: Not explicitly stated. The text mentions "renowned institutions" and "reference customer sites" implying medical professionals (e.g., radiologists, surgeons) were involved, but their specific roles, experience, or certifications are not provided.

    4. Adjudication Method for the Test Set

    • Adjudication Method: Not explicitly stated. The general phrasing "evaluations" and "comparison" does not specify a formal adjudication process.

    5. Multi-Reader Multi-Case (MRMC) Comparative Effectiveness Study

    • Was it done? Not explicitly stated as a formal MRMC study. While "comparison of image quality, artifacts, anatomical representation, and dose" was performed, the summary doesn't detail if multiple human readers quantitatively evaluated cases with and without AI assistance (the AI here refers to the software-driven features like motion compensation rather than a traditional AI algorithm for diagnosis). The study design seems to focus on the technical performance and the clinical utility of the device features rather than a direct comparison of human reader performance with and without AI assistance for interpretation.
    • Effect Size: Not provided.

    6. Standalone Performance (Algorithm only without human-in-the-loop performance)

    • The term "standalone" typically applies to AI algorithms making automated diagnoses. Here, the "AI" or advanced features (motion compensation, extended FOV) are integrated into an imaging device. The "performance" described is largely the technical performance of the imaging system with these features. For example, motion compensation improves image quality, which then benefits human interpretation. The text focuses on the device's performance characteristics with these new features, not an AI algorithm's diagnostic output.

    7. Type of Ground Truth Used

    • For Image Quality/Feature Assessment:
      • Cadaver Studies: Used to assess impact of higher kVp on image quality, and effectiveness of motion compensation in reducing artifacts. The "ground truth" here is the physical reality within the cadavers and the absence/presence of motion artifacts under controlled conditions. Comparison was made against images acquired at different settings or without compensation.
      • Clinical Studies: Used to "validate the new features' impact in routine diagnostic settings" and assess "workflow efficiency." The ground truth for image quality would be subjective clinical assessment by clinicians and objective measurement of image characteristics. For workflow, it would be observed efficiency.
    • No explicit "diagnostic ground truth" (e.g., pathology confirmed disease state) is mentioned, as the study focuses on the image acquisition system's performance, not a specific diagnostic task like lesion detection.

    8. Sample Size for the Training Set

    • Sample Size: Not provided. As this is a 510(k) for an imaging device (updated hardware and software features), not a deep learning AI diagnostic algorithm, the concept of a "training set" in the context of machine learning model development might not directly apply in the same way. The software upgrades are likely to control the hardware parameters and image reconstruction based on engineering principles and pre-defined algorithms, not necessarily a data-driven "training" in the AI/ML sense. If any internal models were trained (e.g., for motion detection), details are not provided.

    9. How the Ground Truth for the Training Set Was Established

    • Since a "training set" in the context of an AI/ML model for diagnosis is not mentioned as part of the submission, how its "ground truth" was established is also not applicable or not provided. The development and verification of the system's features would rely on engineering specifications, phantom studies, and possibly empirical adjustments based on cadaver/clinical imaging, rather than annotated training data for a diagnostic algorithm.
    Ask a Question

    Ask a specific question about this device

    K Number
    K203281

    Validate with FDA (Live)

    Manufacturer
    Date Cleared
    2020-12-22

    (46 days)

    Product Code
    Regulation Number
    892.1650
    Reference & Predicate Devices
    Predicate For
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The IRm is a mobile X-ray system to be used for 2D planar and fluoroscopic and 3D imaging for adult and pediatric patients. It is intended to be used where 2D and 3D information of anatomic structures such as bony and soft tissue and objects with high X-ray attenuation such as (metallic) implants is required.

    The IRm provides an interface that can be used by system integration of the IRm with image guidance systems such as surgical navigation systems.

    Device Description

    The Mobile ImagingRing System (IRm, "Loop-X" or "Loop-X mobile Imaging Robot") is a robotic, digital X-ray system which supports both 2D planar and fluoroscopic X-ray and 3D Cone-Beam Computed Tomography (CBCT) image acquisition and reconstruction of a patient's anatomical regions of interest (ROI).

    The design of the Mobile ImagingRing is based on a ring-gantry ("ring") with two arms mounted: the first arm on gantry carries a monoblock X-ray source and a collimator, the second holds a flat-panel detector. The two arms are independently moveable to accommodate individual patient setups and off-center imaging of regions of interest.

    The ImagingRing m / Loop-X Imaging Robot is intended for mobile use on patients in general and interventional radiology, in sterile and non-sterile areas. The system can be used for diagnostic and interventional purposes by volumetric or planar X-ray imaging and enables image-quided maneuvers and operations in medical fields such as general surgery. traumatology, orthopedics, neurology or radiotherapy. The system is designed for flexible examinations and treatments with patients lying, sitting or standing, with and without contrast agent. It can also be combined with therapy devices such as linear accelerators, particle beam delivery systems or other irradiation devices with active sources and patient positioning systems in Image Guided Radiation Therapy, Intraoperative Radiation Therapy, Brachytherapy or surqical navigation and assistance systems as well as in combination with surgical robots in lmage Guided Surgery, in which the image data provided by the ImagingRing IRm / Loop-X m can be used directly with patient in situ to control the respective therapy maneuvers. Using additional equipment, such as external tracking cameras or the built-in optical cameras, the position of objects such as tracked surgical instruments or pointer tools, for example, can also be determined in the imaging coordinate system. This position data, in combination with the patient's pre- and intra-interventional imaging data, can be used in guided or navigated workflows. The internal cameras of the IRm can also be used to capture pictures and film sequences of the medical procedures.

    AI/ML Overview

    The provided text is a 510(k) summary for the medPhoton Mobile ImagingRing System (IRm, Loop-X Mobile Imaging Robot, Loop-X). This document describes the device and claims substantial equivalence to a predicate device, the Ziehm Vision RFD 3D (K142740).

    The summary states that no clinical testing was performed for the Mobile ImagingRing System and no human studies were conducted. Therefore, there is no information to describe acceptance criteria based on human performance, a study proving the device meets those criteria, or details regarding sample sizes, ground truth establishment, or expert involvement for clinical studies.

    Instead, the submission relies on bench testing to demonstrate substantial equivalence to the predicate device and safety/effectiveness.

    Here's a breakdown of the available information regarding testing:

    1. A table of acceptance criteria and the reported device performance:

    The document does not provide a specific table of acceptance criteria (e.g., in terms of sensitivity, specificity, accuracy for a particular task) and reported device performance in a clinical context with human readers or AI performance.

    Instead, it states:

    • "Results suggest that the subject device performs at least as good as the predicate device (in terms of resolution capabilities) or better (in terms of a larger dynamic range) and therefore support the demonstration of substantial equivalence."

    This indicates that internal performance metrics, likely derived from phantom and cadaver studies, were used to informally compare the subject device's image quality (resolution, dynamic range) to the predicate device. Specific numerical acceptance criteria or performance values are not listed.

    2. Sample size used for the test set and the data provenance:

    • Test Set Sample Size: Not applicable in the context of clinical or AI performance studies from humans. The bench testing involved "phantoms and cadavers." The exact number of phantoms or cadavers used is not specified.
    • Data Provenance: Not applicable for human data. The source of the phantoms and cadavers is not specified. The testing was conducted "internally (by medPhoton) and by an external accredited testing laboratory."

    3. Number of experts used to establish the ground truth for the test set and the qualifications of those experts:

    • Not applicable as no clinical studies with human readers or AI performance were conducted. Ground truth for phantom and cadaver studies typically involves known physical properties or measurements, not expert consensus on medical findings.

    4. Adjudication method for the test set:

    • Not applicable as no clinical studies with human readers or AI performance were conducted.

    5. If a multi reader multi case (MRMC) comparative effectiveness study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance:

    • No, a multi-reader multi-case (MRMC) comparative effectiveness study was not done. This submission pertains to an imaging device itself, not an AI algorithm designed to assist human readers.

    6. If a standalone (i.e. algorithm only without human-in-the-loop performance) was done:

    • No, a standalone algorithm performance study was not done. This device is an X-ray system, not an AI algorithm.

    7. The type of ground truth used:

    • For the bench testing, the ground truth would have been based on the known physical properties and characteristics of the phantoms and cadavers used. The document mentions "resolution capabilities" and "larger dynamic range" as performance metrics, which are objectively measurable properties of the imaging system.

    8. The sample size for the training set:

    • Not applicable as this is not an AI/ML device, and no AI training datasets are mentioned.

    9. How the ground truth for the training set was established:

    • Not applicable as this is not an AI/ML device, and no AI training datasets are mentioned.

    Summary of Device Performance Testing Provided (Non-Clinical):

    The submission highlights the following aspects of performance testing:

    • Bench Testing: Conducted to support substantial equivalence.
      • System level validation was performed to ensure the device meets customer and system requirements and performs according to its intended use.
      • Clinical imaging performance was tested using phantoms and cadavers.
      • Results indicated that the subject device performs "at least as good as the predicate device (in terms of resolution capabilities) or better (in terms of a larger dynamic range)."
      • Additional bench testing addressed mechanical characteristics to demonstrate safety and effectiveness of the device's design.
    • Voluntary Consensus Standards: Compliance demonstrated through internal and external testing (e.g., IEC 60601-1, IEC 60601-1-2, IEC 60601-1-3, IEC 60601-2-43, IEC 60601-2-54, IEC 62304, IEC 62366, and ISO 14971).
    • Animal Testing: None performed.
    • Clinical Testing: None performed.

    The substantial equivalence claim for K203281 is based on the declared equivalence in intended use, technological characteristics, and safety and effectiveness demonstrated through non-clinical bench testing comparing the device to prior predicate and reference devices.

    Ask a Question

    Ask a specific question about this device

    K Number
    K191267

    Validate with FDA (Live)

    Manufacturer
    Date Cleared
    2019-08-01

    (83 days)

    Product Code
    Regulation Number
    892.5050
    Reference & Predicate Devices
    Predicate For
    N/A
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The ImagingRing System on rails (IRr) is an X-ray device consisting of imaging components, supports and software, designed to support patient localization and intended to be used as image guidance equipment as part of the radiation therapy (RT) treatment process, in all areas of the body where such image guidance is determined by a licensed physician. IRr facilitates patient localization by means of inaging patient anatomy including the therapeutic target volume, critical structures, bone and soft tissue with or without the use of implanted markers or contrast agents.

    IRr provides 2D planar imaging (including recording sequences of 2D frames for motion analysis) and 3D volumetric imaging before, during and after irradiation, support pationing, monitoring and management of internal target motion, and decision making as a function of target position, size, shape and displacement resulting from patient set-up deviation, organ deformation and anatomical movement.

    With the goal to accurately perform patient alignment with respect to an external treatment beam and to spare critical organs surrounding the target volume, the IRr is intended to be embedded in the radiotherapy workflow, i.e. being able to communicate with third party systems used in particle therapy or LINAC based RT such as Oncology Information Systems (OIS) or Radiotherapy Control Systems (RTCS) - receiving commands and data from and providing information to these party systems (e.g., receiving command from RTCS to start an image acquisition and providing image data. providing input for third party RTCS for repositioning of the patient).

    Device Description

    This Traditional 510(k) describes modifications made to the medPhoton ImagingRing System. The kev differences are:

    • In contrast to the existing ImagingRing System. where the ring (imager gantry) is mounted ● on the patient table, in the current system, the ring is mounted on a ceiling-mounted rail which allows longitudinal movement of the ring.
    • Thus, the ImagingRing System on Rails does not include the patient table. ●
    • The diameter of the gantry (ring structure carrying the imaging components X-ray generator ● and flat-panel detector) has been increased, providing bigger gantry clearance. This is facilitating positioning of the patient relative to the ImagingRing System on Rails using a Patient Positioning System (PPS) that is provided and controlled by a system integrator since not part of the ImagingRing System on Rails.
    • A new control console, being used as human machine interface, has been developed to ● improve usability and to simplify imaging workflows (Control Console 2.0).
    • In addition to the existing basic and slightly extended software (ImagingRing Software ● Suite), front-end software (medPhoton controls) was added to simplify imaging workflows and integration with overall radiation therapy workflow software that is provided and controlled by a svstem integrator.

    The remaining characteristics and the basic technology have remained the same. The same essential components (X-ray generator and -detector, control system, etc.) are used.

    Similar to the ImagingRing System, the ImagingRing System on Rails (Rr) is an X-ray imager that is intended to be integrated into a radiation therapy treatment system (e.g. a proton therapy system with its subsystems and workflows) by a system integrator. A major reason for the further development of the ImagingRing System has been to provide a simpler X-ray imager integration option for system integrators.

    The medPhoton ImagingRing System on Rails (IRr) is an imaging system designed to obtain Two-Dimensional (2D) and Three-Dimensional (3D) X-ray images. The images visualize patient's anatomy whose information can be used to accurately position or re-position the patient undergoing radiotherapy treatment.

    The IRr consists of

    • . hardware called ImagingRing (IR) consisting of rails for longitudinal movement, ring gantry, flat-panel detector, X-ray source, generator, control cabinet, control console;
    • software comprising the ImagingRing Software Suite (ImRiSS) and the medPhoton ● Controls (mPc) to orchestrate image acquisition and data processing;
    • programmable logic controller (PLC) components and related software (ImagingRing ● Control System - ImRiCS), to execute and control motion and image acquisition.
    AI/ML Overview

    The provided text does not contain information about studies proving that the ImagingRing System on Rails meets specific acceptance criteria related to its performance in terms of diagnostic accuracy or clinical effectiveness. The document is a 510(k) summary for a medical device, which focuses on demonstrating substantial equivalence to a predicate device rather than presenting detailed performance studies against specific acceptance criteria for AI-assisted or standalone diagnostic capabilities.

    The document discusses the device's technical specifications and adherence to safety and performance standards (e.g., IEC 60601 series, IEC 62304, IEC 62366, ISO 14971) and outlines performance characteristics like spatial resolution, low contrast visibility, and geometric accuracy for both 2D and CBCT imaging. However, these are presented as technical specifications, not as results from a study against specific acceptance criteria for diagnostic performance or human reader improvement with AI assistance.

    Specifically, the document states:

    • "Summary of performance testing: The system is subject to compliance testing to voluntary consensus safety standards. Details of the standards employed in the design are specified in chapter 9... The results from verification and validation testing prove the conformance to applicable standards and demonstrate that safety & effectiveness have been achieved."
    • "medPhoton GmbH did not perform any animal testing for the ImagingRing System on Rails."
    • "medPhoton GmbH did not perform any clinical testing for the ImagingRing System on Rails."

    Based on the provided text, it's not possible to populate the requested table or answer the questions related to clinical performance studies, such as sample size, data provenance, expert ground truth establishment, MRMC studies, or standalone algorithm performance, as these types of studies were explicitly stated as not performed.

    Therefore, I cannot provide a detailed answer to your request as the information is not present in the provided text.

    Ask a Question

    Ask a specific question about this device

    K Number
    K161400

    Validate with FDA (Live)

    Manufacturer
    Date Cleared
    2016-12-08

    (202 days)

    Product Code
    Regulation Number
    892.5050
    Reference & Predicate Devices
    Predicate For
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The ImagingRing System (IRS) is an X-rav device consisting of (1) imaging components, supports and (2) patient support structure (couch top), designed to support patient localization in the Couch Coordinate System (CCS) and intended to be used as image guidance equipment as part of the radiation therapy (RT) treatment process, in all areas of the body where such image guidance is determined by a licensed physician.

    IRS facilitates patient localization by means of imaging patient anatomy including the therapeutic target volume, critical structures, bone and soft tissue with or without the use of implanted markers or contrast agents.

    IRS provides 2D planar imaging (including streaming and recording sequences of 2D frames for motion and 3D volumetric imaging before, during and after irradiation, and is intended to support pationing, monitoring and management of internal target motion, and decision making as a function, size, shape and displacement resulting from patient set-up deviation. organ deformation and anatomical movement.

    With the goal to accurately perform patient alignment with respect to an external treatment beam and to spare critical organs surrounding the target volume, IRS is intended to be:

    · embedded in the radiotherapy workflow, i.e. being able to communicate with third party systems used in particle therapy or LINAC based RT such as Oncology Information Systems (OIS) or Radiotherapy Control Systems (RTCS) in order to receive commands and data from and provide information to (e.g., receiving command from RTCS to start an image acquisition and providing image data to RTCS for the purpose to calculate and execute the patient (re)-positioning vector externally in the third party system)

    · interfaced with a Patient Positioning Systems (PPS), like - but not limited to - a robotic multi-axis system, to allow the calculated (re)-positioning vector to be applied with respect to Coordinate Systems the treatment delivery unit relates to.

    Device Description

    The medPhoton IRS is a standalone imaging system designed to obtain TwoDimensional (2D) and Three-Dimensional (3D) X-ray images. The images visualize patient's anatomy whose information can be used to accurately position or re-position the patient undergoing radiotherapy treatment.

    The IRS consists of

    • · hardware called ImagingRing (IR) consisting of couch top, ring, detector, X-ray source, generator, etc .;
    • · software called ImagingRing Software Suite (ImRiSS), to orchestrate image acquisition and data processing:
    • . programmable logic controller (PLC) components and related software (e.g., ImagingRing Control System - IRCS), to execute and control image acquisition.

    The system is designed in a way such that it provides the following key features:

      1. During imaging acquisition, the IR can be moved along the couch top in order to acquire images of any anatomical region of interest.
      1. The X-ray source and detector can move independently in order to enable nonisocentric acquisition trajectories (i.e., to focus on a selectable center of interest within the patient in an axial plane) and variable size of the axial Field Of View (FOV).
      1. The combination of imaging arm and couch top is designed to be directly attached to a range of Patient Positioning Systems (PPS) including multi-axis robotic devices.

    The imaging device is integrated with a couch top. The independently moveable components allow for acquisition of X-ray projective images. These provide the foundation for 2D planar imaging as well as acquisition and reconstruction of 3D ConeBeam Computed Tomography (CBCT) images around customizable centers of interest.

    AI/ML Overview

    The provided text describes the medPhoton ImagingRing System (IRS) and compares its characteristics to predicate devices (Elekta XVI R5.0 and Qfix kVue) to demonstrate substantial equivalence for FDA 510(k) clearance. However, the document does NOT contain details about a specific study proving the device meets acceptance criteria. Instead, it outlines performance characteristics and states that testing was performed to evaluate safety and performance requirements.

    Therefore, the following information will be extracted from the comparison tables and accompanying text. Aspects not mentioned in the document will be explicitly stated as "Not mentioned in the provided text."

    1. A table of acceptance criteria and the reported device performance

    The document presents performance characteristics by comparing the ImagingRing System's specifications against those of predicate devices. The values for the predicate devices essentially serve as the "acceptance criteria" or benchmarks that the new device aims to match or exceed for substantial equivalence.

    CharacteristicAcceptance Criteria (Predicate Device XVI R5.0)Reported Device Performance (ImagingRing System)
    Position Accuracy±0.3°±0.2°
    2D low contrast visibility≥12 disks visible≥12 disks visible
    2D spatial resolution≥1.4 line/mm≥1.6 line/mm
    CBCT spatial resolution≥7 lp/cm≥10 lp/cm (up to 18)
    CBCT low contrast resolution< 1.5%< 1.5%
    CBCT uniformity< 2%< 2%
    Transverse geometric accuracy< 1 mm< 1 mm
    Leakage radiation (loading state)< 1.0 mGy/h0.1979 mGy/h
    Leakage radiation (not loading)< 20 mGy/h0 mGy/h
    X-ray beam must not be larger than boundaries by more than 3% of SID (image receptor plane)YesYes
    Aluminum Equivalence Thickness (AET) @ 100kVpNot specified (kVue context)1.9 mm (compared to kVue)
    Water Equivalence Thickness (WET) @ 6 MVNot specified (kVue context)≤16.5 mm (compared to kVue)
    Meets deflection requirements of IEC 60976< 5 mm (kVue)< 1 mm effect in imaging volume accuracy (compared to kVue)

    2. Sample size used for the test set and the data provenance (e.g. country of origin of the data, retrospective or prospective)

    Not mentioned in the provided text. The document refers to "module and integration verification as well as system level validation" but does not detail specific test sets, sample sizes, or data provenance (e.g., country of origin, retrospective/prospective nature).

    3. Number of experts used to establish the ground truth for the test set and the qualifications of those experts (e.g., radiologist with 10 years of experience)

    Not mentioned in the provided text.

    4. Adjudication method (e.g., 2+1, 3+1, none) for the test set

    Not mentioned in the provided text.

    5. If a multi-reader multi-case (MRMC) comparative effectiveness study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance

    Not mentioned in the provided text. This document describes an imaging hardware system, not an AI-assisted diagnostic tool for human readers.

    6. If a standalone (i.e. algorithm only without human-in-the-loop performance) was done

    The document does not describe a "standalone" algorithmic performance in the context of an AI device. It describes the ImagingRing System as a standalone imaging system (hardware and software) designed to acquire images and support patient localization. Its performance metrics (e.g., spatial resolution, low contrast visibility) characterize the system itself, not an algorithm's diagnostic capabilities.

    7. The type of ground truth used (expert consensus, pathology, outcomes data, etc.)

    Not explicitly mentioned for the reported performance metrics. However, typical "ground truth" for physical performance metrics like spatial resolution, low contrast visibility, and geometric accuracy usually involves physical phantoms (e.g., Catphan 503 mentioned as a phantom for predicate device data) and calibrated measurement systems.

    8. The sample size for the training set

    Not applicable. The document describes a medical imaging device, not a machine learning model that would typically have a "training set."

    9. How the ground truth for the training set was established

    Not applicable. The document describes a medical imaging device, not a machine learning model that would typically have a "training set."