510(k) Data Aggregation

    K Number
    K252275

    Validate with FDA (Live)

    Date Cleared
    2026-01-29

    (191 days)

    Product Code
    Regulation Number
    890.3800
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    N/A
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The electric scooter is a motor driven, indoor and outdoor transportation vehicle with the intended use to provide mobility to a disabled or elderly person limited to a seated position.

    Device Description

    The electric scooter is a motor driven, indoor and outdoor transportation vehicle with the intended use to provide mobility to a disabled or elderly person limited to a seated position.

    The Mobility Scooter, Model DDF100, consists with two front wheels, two rear wheels, two rear anti-tip wheels, one seat system with one back support and two arm supports, an adjustable steering column, a tiller console, an electric motor, an electromagnetic brake, one rechargeable Lithium-Ion battery and one off-board charger.

    The movement of the wheelchair is controlled by the speed lever and steering column. The device is installed with an electromagnetic brake that will engage automatically when the wheelchair is not in use and the brake can be manually adjusted to free wheel mode. The scooter only can be operated on the flat road.

    AI/ML Overview

    N/A

    Ask a Question

    Ask a specific question about this device

    K Number
    K241529

    Validate with FDA (Live)

    Date Cleared
    2024-11-22

    (176 days)

    Product Code
    Regulation Number
    890.3860
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The device is a motor driven, indoor and outdoor transportation vehicle with the intended use to provide mobility to a disabled or elderly person limited to a seated position.

    Device Description

    The subject device, Powered Wheelchair, mainly powered by battery, motivated by DC motor, driven by user controlling joystick and adjusting speed. The Powered Wheelchairs consist of two foldable armrests, a backrest, a seat cushion, a safety belt, a foldable frame, two rear driving wheels with hub motor/electromagnetic brake assemblies, two pivoting casters, two Li-ion batteries, an off-board battery charger, a control panel, and an electric motor controller. The NXN20-209 Powered Wheelchair is intended to provide mobility to a disabled or elderly person limited to a seated position. The Powered Wheelchair has 7 inch front wheel and 12 inch rear tire. The motor of electric wheelchair is DC24V 200W; the battery is 24V 12AH, Li-ion battery; the charger is 24V/3A. Max. loading can not be over than 110Kgs. Max. distance of travel on the fully charged battery is 16.5 km and Max. speed forward is 6km/h. The braking time is about 2s, and the braking distance is less than or equal to 1.76m.

    AI/ML Overview

    The provided text describes a 510(k) submission for a Powered Wheelchair (NXN20-209). This type of submission focuses on demonstrating substantial equivalence to a legally marketed predicate device rather than proving clinical effectiveness through a comparative study with a "human-in-the-loop" component as is common for AI/ML-driven diagnostics. The information provided is primarily related to engineering performance and safety standards for the physical device itself.

    Therefore, the requested information regarding acceptance criteria and a study that proves the device meets the acceptance criteria, as phrased for AI/ML device performance (e.g., sample size for test set/training set, number of experts, adjudication methods, MRMC studies, standalone performance, ground truth establishment), is not applicable in the context of this traditional medical device submission.

    The document states: "No clinical study implemented for the electric wheelchair." This confirms that the typical clinical performance studies asked for in your prompt were not conducted or required for this device's clearance.

    Instead of AI/ML-specific performance criteria, the acceptance criteria for this powered wheelchair are based on adherence to recognized international standards for wheelchairs and a comparison of its physical and performance characteristics to a predicate device.

    Here's a breakdown of what the document does provide in relation to acceptance criteria and performance:

    1. A table of acceptance criteria and the reported device performance:

    The document includes two comparison tables (Table 1: General Comparison and Table 2: Performance Comparison) that demonstrate the similarity and conformance of the proposed device to a predicate device and relevant standards. While not "acceptance criteria" in the sense of a specific numerical threshold for a diagnostic outcome, these aspects represent the performance benchmarks the device successfully met.

    Table 1 & 2 (summarized and adapted to your request format):

    Acceptance Criteria CategorySpecific Metric/StandardReported Device Performance (NXN20-209)Predicate Device (A08) PerformanceRemark/Acceptance Demonstrated By
    General CharacteristicsProduct CodeITIITISame (Substantially Equivalent)
    Regulation No. (21 CFR)890.3860890.3860Same (Substantially Equivalent)
    ClassificationClass IIClass IISame (Substantially Equivalent)
    Intended UseMotor driven, indoor/outdoor transportation for disabled/elderly limited to seated positionMotor driven, indoor/outdoor trans. for disabled/elderly limited to seated positionSame (Substantially Equivalent)
    Driving systemDirect drive on rear wheelsDirect drive on rear wheelsSame (Substantially Equivalent)
    Movement control methodBy Joystick controlBy Joystick controlSame (Substantially Equivalent)
    Number of wheels44Same (Substantially Equivalent)
    Brake systemAutomatic electromagnetic brake systemElectromagnetic brake systemSame (Substantially Equivalent)
    Speed control methodJoystick control methodJoystick control methodSame (Substantially Equivalent)
    Performance MetricsISO 7176-1:2014 Static StabilityForward: 18.9°, Rearward: 18.2°, Sideways: 20.7°Not publicly availableBoth devices evaluated according to same standard; differences in static stability will not impact safety and effectiveness.
    ISO 7176-4:2008 Cruising Range16.5 km20 kmComplies with ISO 7176-4:2008; differences do not affect safety and effectiveness.
    ISO 7176-3:2012 Minimum Braking Distance≤ 1.76m1mSimilar; compliant with standard.
    ISO 7176-6:2018 Max Speed Forwards1.66 m/s (6 km/h)1.94m/s (7 km/h)Both devices evaluated according to same standard; differences will not impact safety and effectiveness.
    ISO 7176-6:2018 Max Speed Backward0.8 m/s (2.88 km/h)Not publicly availableBoth devices evaluated according to same standard; differences will not impact safety and effectiveness.
    Max. loading (weight capacity)242.5 lbs (110 kg)220 lbs (100 kg)Device supports more loading weight without raising new safety/effectiveness concerns.
    Min. Turning Radium870mm800mmSimilar performance.
    Obstacle climbing25 mm40 mmSmaller height in obstacle climbing will not impact safety and effectiveness.
    Software Verification and Validation TestingCompliant with FDA GuidanceIncludedCompliance with FDA guidance for software functions documented.
    Safety & MaterialsBiocompatibility of materials contacting userCompliant with FDA Guidance, ISO 10993-1Compliant with ISO 10993-1, FDA Guidance (tests included)Biocompatibility evaluation carried out per ISO 10993-1; no new safety and effectiveness concerns due to differences.
    Compliance with EMC standards (IEC 60601-1-2:2020, ISO 7176-21:2009)Performed (Implied by inclusion in Non-Clinical Testing Summary)Performed (Implied by inclusion in Non-Clinical Testing Summary)Test results demonstrated compliance.
    Compliance with other ISO 7176 series for safety, fatigue, dimensions etc.Performed and CompliantPerformed (Implied by predicate clearance)Test results demonstrated compliance with numerous ISO standards for wheelchairs.

    2. Sample sized used for the test set and the data provenance (e.g. country of origin of the data, retrospective or prospective):

    • Not Applicable. No human subjects "test set" was used for performance evaluation in the context of an AI/ML algorithm. The testing was non-clinical (bench and engineering tests) based on international standards for mechanical and electrical safety and performance of wheelchairs. The document does not specify a "sample size" for these non-clinical tests in the way one would for a clinical study. Data provenance is implied by the testing standards and the manufacturer's location (China), but not detailed as typical for clinical data.

    3. Number of experts used to establish the ground truth for the test set and the qualifications of those experts (e.g. radiologist with 10 years of experience):

    • Not Applicable. Ground truth, in the AI/ML sense, is not established for this type of device. Performance is determined through objective, standardized engineering tests.

    4. Adjudication method (e.g. 2+1, 3+1, none) for the test set:

    • Not Applicable. Not a clinical study requiring adjudication.

    5. If a multi reader multi case (MRMC) comparative effectiveness study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance:

    • Not Applicable. This is not an AI-assisted diagnostic or image analysis device, so MRMC studies are irrelevant.

    6. If a standalone (i.e. algorithm only without human-in-the-loop performance) was done:

    • Not Applicable. This is a physical powered wheelchair, not an AI algorithm. Software verification and validation (standalone) was done for the device's control software, ensuring it functions correctly, but this is distinct from AI/ML performance.

    7. The type of ground truth used (expert consensus, pathology, outcomes data, etc):

    • Not Applicable/Objective Standards. The "ground truth" for this device's performance is compliance with established international engineering and safety standards (e.g., ISO 7176 series, IEC 60601-1-2) which define objective, measurable criteria for stability, speed, braking, etc.

    8. The sample size for the training set:

    • Not Applicable. No AI/ML training set is mentioned or relevant for this device.

    9. How the ground truth for the training set was established:

    • Not Applicable. No AI/ML training set is mentioned or relevant for this device.

    In summary: The provided document is for a traditional powered medical device, not an AI/ML-driven diagnostic or imaging device. The "acceptance criteria" and "study that proves the device meets the acceptance criteria" in this context refer to documented compliance with relevant recognized industry standards (primarily ISO and IEC) through non-clinical testing, and demonstrated substantial equivalence to a predicate device.

    Ask a Question

    Ask a specific question about this device

    K Number
    K241603

    Validate with FDA (Live)

    Date Cleared
    2024-11-20

    (169 days)

    Product Code
    Regulation Number
    890.3860
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    N/A
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The device is a motor driven, indoor and outdoor transportation vehicle with the intended use to provide mobility to a disabled or elderly person limited to a seated position.

    Device Description

    The subject device, Powered Wheelchair, mainly powered by battery, motivated by DC motor, driven by user controlling joystick and adjusting speed. The Powered Wheelchairs consist of two foldable armrests, a backrest, a seat cushion, a safety belt, a foldable frame, two rear driving wheels with hub motor/electromagnetic brake assemblies, two pivoting casters, two Li-ion batteries, an off-board battery charger, a control panel, and an electric motor controller.

    The NXN20-208 and NXN20-211 Powered Wheelchair is intended to provide mobility to a disabled or elderly person limited to a seated position.

    The Powered Wheelchair has 7 inch front wheel and 11 inch rear tire.

    The motor of electric wheelchair is DC24V 200W; the battery is 24V 12AH, Li-ion battery; the charger is 24V/3A.

    Max. loading can not be over than 110Kgs.

    Max. distance of travel on the fully charged battery is 16 km and Max. speed forward is 6km/h.

    The braking time is about 2s, and the braking distance is <=1.77m.

    AI/ML Overview

    The provided document is a 510(k) premarket notification for a Powered Wheelchair (models NXN20-208, NXN20-211). It focuses on demonstrating substantial equivalence to a predicate device (A08 Power Wheelchair, K163204) rather than presenting a study to prove acceptance criteria for a novel device. Therefore, much of the requested information regarding clinical studies, ground truth establishment, expert adjudication, and AI performance is not applicable to this submission.

    However, the document does contain "acceptance criteria" through a demonstration of compliance with recognized standards and a comparison of performance characteristics to a predicate device, which serves as a benchmark for safety and effectiveness in this regulatory context.

    Here's a breakdown of the available information:

    1. Table of Acceptance Criteria (Standard Compliance) and Reported Device Performance

    For a medical device like a powered wheelchair, acceptance criteria are generally defined by compliance with a set of established performance standards. The "reported device performance" is demonstrated by the completion of non-clinical tests verifying compliance with these standards.

    Acceptance Criteria (Standard)Reported Device Performance (Compliance Status)
    ISO 7176-1:2014 Wheelchairs - Part 1: Determination of static stabilityComplies
    ISO 7176-2:2017 Wheelchairs - Part 2: Determination of dynamic stability of electrically powered wheelchairsComplies
    ISO 7176-3:2012 Wheelchairs - Part 3: Determination of effectiveness of brakesComplies
    ISO 7176-4:2008 Wheelchairs - Part 4: Energy consumption of electric wheelchairs and scooters for determination of theoretical distance rangeComplies
    ISO 7176-5:2008 Wheelchairs - Part 5: Determination of overall dimensions, mass and manoeuvring spaceComplies
    ISO 7176-6:2018 Wheelchairs - Part 6: Determination of maximum speed, acceleration and deceleration of electric wheelchairsComplies
    ISO 7176-7:1998 Wheelchairs - Part 7: Measurement of seating and wheel dimensionsComplies
    ISO 7176-8:2014 Wheelchairs - Part 8: Requirements and test methods for static, impact and fatique strengthsComplies
    ISO 7176-9:2009 Wheelchairs - Part 9: Climatic tests for electric wheelchairsComplies
    ISO 7176-10:2008 Wheelchairs - Part 10: Determination of obstacle-climbing ability of electrically powered wheelchairsComplies
    ISO 7176-11:2012 Wheelchairs - Part 11: Test dummiesComplies
    ISO 7176-13:1989 Wheelchairs - Part 13: Determination of coefficient of friction of test surfacesComplies
    ISO 7176-14:2008 Wheelchairs - Part 14: Power and control systems for electrically powered wheelchairs and scooters - Requirements and test methodsComplies
    ISO 7176-15:1996 Wheelchairs - Part 15: Requirements for information disclosure, documentation and labelingComplies
    ISO 7176-21:2009 Wheelchairs - Part 21: Requirements and test methods for electromagnetic compatibility of electrically powered wheelchairs and scooters, and battery chargersComplies
    ISO 7176-22:2014 Wheelchairs - Part 22: Set-up proceduresComplies
    ISO 7176-25:2013 Wheelchairs - Part 25: Batteries and chargers for powered wheelchairsComplies
    ISO 16840-10:2021 Wheelchair seating - Part 10: Resistance to ignition of postural support devices - Requirements and test methodComplies
    IEC 60601-1-2:2020 Medical electrical equipment - Part 1-2: General requirements for safety - Collateral standard: Electromagnetic compatibility - Requirements and testsComplies
    Software Verification and Validation Testing (according to FDA Guidance)Complies
    Biocompatibility of materials contacting user (Comply with FDA Guidance)Complies

    Performance Characteristics (Comparison with Predicate Device):

    ItemProposed DevicePredicate DeviceAcceptance (Remark)
    Overall lengthNXN20-208: 1000mm; NXN20-211: 950mm890 mmMinor differences will not impact safety and effectiveness.
    Overall width600mm603 mmMinor differences will not impact safety and effectiveness.
    Stowage length340mm324 mmMinor differences will not impact safety and effectiveness.
    Stowage width600mm603 mmMinor differences will not impact safety and effectiveness.
    Stowage heightNXN20-208: 775mm; NXN20-211: 765mm670 mmMinor differences will not impact safety and effectiveness.
    Weight, w/ BatteryNXN20-208: 42.99 lbs./19.5kg; NXN20-211: 36.48 lbs./16.55kg61.7 lbs. /28 kgThe difference will not raise any new safety and effectiveness concerns.
    Front wheel (inch)7 (PU solid tire)8 (PU solid tire)Smaller sizes of front wheels.
    Rear tire (inch)11 (PU solid tire)10 (PU solid tire)Larger sizes of rear wheels bring steadier pivoting function than the predicate device.
    Cruising Range (km)1620The subject device complies with ISO 7176-4:2008 for energy consumption; these differences do not affect safety and effectiveness.
    Obstacle climbing (mm)2540The smaller height in the obstacle climbing will not impact the safety and effectiveness of the subject device.
    Static stability forward18.8°Not publicly availableBoth devices evaluated per ISO 7176-1:2014; different static stability will not impact safety and effectiveness.
    Static stability rearward20.4°Not publicly availableBoth devices evaluated per ISO 7176-1:2014; different static stability will not impact safety and effectiveness.
    Static stability sideways20.5°Not publicly availableBoth devices evaluated per ISO 7176-1:2014; different static stability will not impact safety and effectiveness.
    Max. loading (kg)242.5lbs (110kg)220 lbs (100 kg)More loading weight means more convenient for transportation.
    Min. Turning radiumNXN20-208: 850mm; NXN20-211: 840mm800mmSimilar
    Minimum braking distance<=1.77m1mSimilar
    Max Speed Forwards1.66 m/s (6 km/h)1.94 m/s (7 km/h)Devices evaluated per ISO 7176-6:2018; the difference will not impact safety and effectiveness.
    Max. Speed Backward0.8 m/s (2.88 km/h)Not publicly availableDevices evaluated per ISO 7176-6:2018; the difference will not impact safety and effectiveness.
    ControllerYanteon Mechanical & Electronic Technology (Shanghai) Co. Ltd. Joystick Y2450M Controller Y2430MYisheng Electric Co. Ltd. WS-1, 40AAlthough different controllers are used, both control systems are similar and evaluated according to ISO 7176-14:2008 and software validation requirements; no new safety and effectiveness concerns.

    2. Sample size used for the test set and the data provenance

    • Sample Size for Test Set: Not explicitly stated as this is a device clearance based on standard compliance and comparison, not an image-based AI study with a "test set" in that context. The tests were performed on the physical device models NXN20-208 and NXN20-211.
    • Data Provenance: The document states "Non clinical tests were conducted to verify that the proposed device met all design specifications." These tests would have been conducted by the manufacturer (Zhejiang Nysin Medical Co., Ltd.) in China or by a contracted testing facility. The specific location and retrospective/prospective nature of the individual test data are not detailed, but it is implied to be new test data generated for this submission.

    3. Number of experts used to establish the ground truth for the test set and the qualifications of those experts

    • Number of Experts: Not applicable. For a powered wheelchair, "ground truth" is typically established through objective measurements and testing against engineering and safety standards, rather than expert consensus on medical images or patient diagnoses.
    • Qualifications of Experts: Not applicable for the reasons above. Testing would be performed by qualified engineers and technicians.

    4. Adjudication method for the test set

    • Adjudication Method: Not applicable. The "test set" here refers to physical device testing against established standards, not a diagnostic task requiring expert adjudication.

    5. If a multi-reader multi-case (MRMC) comparative effectiveness study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance

    • MRMC Study: No, this is not an AI-based diagnostic device. It is a powered wheelchair. Therefore, no MRMC study was conducted, and this question is not applicable.

    6. If a standalone (i.e., algorithm only without human-in-the-loop performance) was done

    • Standalone Performance: Not applicable. This is not an AI algorithm.

    7. The type of ground truth used

    • Type of Ground Truth: The "ground truth" for this device is based on objective, quantifiable measurements against internationally recognized performance and safety standards (e.g., ISO 7176 series, IEC 60601-1-2) and visual inspections of the device. For biocompatibility, it's compliance with FDA guidance and ISO 10993-1.

    8. The sample size for the training set

    • Sample Size for Training Set: Not applicable. This is not a machine learning or AI device that requires a training set.

    9. How the ground truth for the training set was established

    • Ground Truth for Training Set: Not applicable. There is no training set for this device.
    Ask a Question

    Ask a specific question about this device

    K Number
    K241379

    Validate with FDA (Live)

    Date Cleared
    2024-09-16

    (124 days)

    Product Code
    Regulation Number
    890.3860
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    N/A
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The device is a motor driven, indoor and outdoor transportation vehicle with the intended use to provide mobility to a disabled or elderly person limited to a seated position.

    Device Description

    The subject device, Powered Wheelchair, mainly powered by battery, motivated by DC motor, driven by user controlling joystick and adjusting speed. The Powered Wheelchairs consist of two foldable armrests, a backrest, a seat cushion, a safety belt, a foldable frame, two rear driving wheels with hub motor/electromagnetic brake assemblies, two pivoting casters, two Li-ion batteries, an off-board battery charger, a control panel, and an electric motor controller. The NXN20-205 and NXN20-205M Powered Wheelchair is intended to provide mobility to a disabled or elderly person limited to a seated position. The Powered Wheelchair has 7 inch front wheel and 12 inch rear tire. The motor of electric wheelchair is DC24V 200W; the battery is 24V 12AH, Li-ion battery; the charger is 24V/3A. Max. loading can not be over than 110Kgs. Max. distance of travel on the fully charged battery is 16km and Max. speed forward is 5.5km/h. The braking time is about 2s, and the braking distance is ≤790m.

    AI/ML Overview

    The provided text is a 510(k) Summary for a Powered Wheelchair (NXN20-205, NXN20-205M) and does not contain details about acceptance criteria and a study proving a device meets them in the context of an AI/ML medical device.

    The document describes a traditional medical device (a powered wheelchair) and its substantial equivalence to a predicate device based on non-clinical testing against established ISO standards for wheelchairs. There is no mention of AI or machine learning in this report.

    Therefore, I cannot provide the requested information, such as:

    • Table of acceptance criteria and reported device performance for an AI/ML device: This document details performance specifications for a physical wheelchair (e.g., speed, range, loading capacity, stability), not AI/ML metrics.
    • Sample size used for the test set and data provenance: No test set or data provenance for an AI/ML model is mentioned.
    • Number of experts used to establish ground truth and qualifications: This is irrelevant for a physical powered wheelchair.
    • Adjudication method: Not applicable.
    • MRMC comparative effectiveness study: Not conducted as no AI assistance is involved.
    • Standalone (algorithm only) performance: Not applicable.
    • Type of ground truth used: Not applicable in the context of an AI/ML device.
    • Sample size for the training set: No training set is mentioned.
    • How the ground truth for the training set was established: Not applicable.

    The document indicates that "Software Verification and Validation Testing" was performed in accordance with FDA Guidance for device software functions, but this refers to traditional software engineering validation, not AI/ML model validation with ground truth and performance metrics.

    In summary, the provided text does not contain the information required to answer the prompt about acceptance criteria and studies for an AI/ML device.