Search Filters

Search Results

Found 2 results

510(k) Data Aggregation

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The intended use of the VenAir Sequential Compression System (hereby referenced as "VenAir system") is to help prevent Deep Vein Thrombosis (DVT) and pulmonary embolism. The garments are single patient use - do not reuse. The VenAir system is intended for use only in professional healthcare facility environment by trained medical staff. It is not for use in the home healthcare environment. The VenAir system should be used as part of a prescribed plan of care.

    Device Description

    The VenAir system is a sequential pneumatic compression system by applying sequential and gradient pressure to increase venous blood flow and circulation in at-risk patients to help prevent deep vein thrombosis and pulmonary embolism. The product consists of the pump, tubing sets, and disposable (single patient use) garments (thigh, calf, and foot optional purchase) and focuses on compressing the limbs to enhance better blood circulation.

    The VenAir system has digital sensors to check the garment connections, pressure output and power supply. On the other hand, operator can follow this manual to check the error code and action as advised.

    AI/ML Overview

    N/A

    Ask a Question

    Ask a specific question about this device

    K Number
    K243023

    Validate with FDA (Live)

    Manufacturer
    Date Cleared
    2025-05-23

    (238 days)

    Product Code
    Regulation Number
    868.5905
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    N/A
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The Mask is intended to provide an interface for Continuous Positive Airway Pressure (CPAP) or bi-level therapy. The Mask is intended for single-patient reuse in the home and multi-patient multi-use in the hospital environment.

    The Mask is to be used by adults weighing ≥ 30 kg whom positive airway pressure (CPAP or bi-level system) has been prescribed.

    Device Description

    WiZARD 520 Full Face Mask's cushion and frame provide a secure interface between the mask and the patient's face and the flexible cushion improves seal. A series of vents on the elbow, serve as an exhalation vent to purge the exhaled carbon dioxide from the mask. The mask is designed to maintain a continuous airflow to minimize the amount of CO2 rebreathed by the patient. The mask features a wider visibility design that ensures a clear line of sight. It also includes a fabric frame equipped with 3D-shaped headgear for enhanced comfort and stability.

    WiZARD 520 Full Face Mask is intended for connection to a positive air pressure source such as CPAP or bi-level for the treatment of Obstructive Sleep Apnea. WiZARD 520 Full Face Mask can be linked to the CPAP or bi-level system's standard 22 mm breathing tube using a swivel hose, flexible tube, and tubing connector. Various sizes (small, medium, and large) are offered to ensure adequate fit over the extended patient population.

    AI/ML Overview

    The provided text is an FDA 510(k) clearance letter for the WiZARD 520 Full Face Mask. This document describes the substantial equivalence of the new device to a predicate device, focusing on its physical and functional characteristics. It does not describe a study proving the device meets acceptance criteria related to an AI/Machine Learning model, nor does it provide information relevant to a Multi-Reader Multi-Case (MRMC) comparative effectiveness study or the establishment of ground truth by expert consensus.

    The clearance is for a physical medical device (a CPAP mask), not a software or AI-driven diagnostic tool. Therefore, the concepts of "acceptance criteria for an AI model," "sample size for test/training sets," "number of experts for ground truth," "adjudication method," "MRMC study," or "standalone algorithm performance" are not applicable to this document.

    The document discusses performance tests that are standard for a physical medical device, such as CO2 rebreathing, pressure-flow characteristics, resistance to flow, anti-asphyxia valve operating pressures, and sound levels. These are engineering and physiological performance metrics, not metrics for an AI's diagnostic accuracy or expert agreement.

    Therefore, I cannot fulfill your request using the provided input, as the input material does not contain the type of information you've asked for. It's crucial to understand that a 510(k) for a physical medical device like a CPAP mask does not involve AI development or validation processes.

    Ask a Question

    Ask a specific question about this device

    Page 1 of 1