Found 2 results

510(k) Data Aggregation

    K Number
    K160001

    Validate with FDA (Live)

    Manufacturer
    Date Cleared
    2016-02-12

    (39 days)

    Product Code
    Regulation Number
    892.2050
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The TraumaCad Mobile Release 2.0 program is indicated for assisting healthcare professionals in preoperative planning of orthopedic surgery. The device allows for overlaying of prosthesis templates on radiological images, and includes tools for performing measurements on the image and for positioning the template. Clinical judgment and experience are required to properly use the software is not for primary image interpretation. The software is not for use on mobile phones.

    Device Description

    TraumaCad Mobile Release 2.0 allows surgeons to evaluate digital images while performing various pre-operative surgical planning and evaluation of images. This software application enables surgeons to plan operations on screen, execute measurements, and facilitate the film-less orthopedic practice. The program features full PACS integration and an extensive regularly updated library of digital templates from leading manufacturers. TraumaCad Mobile Release 2.0 supports DICOM and enables the importing and exporting of image files from a central PACS system, or Quentry (Class I device registered by Brainlab AG in the FDA). TraumaCad Mobile Release 2.0 is the web based version of the predicate device TraumaCad 2.0 (cleared by the FDA on March 19, 2008). The TraumaCad Mobile Release 2.0 has the same basic functionality as the predicate device, but is now available as a web based version on additional platforms. TraumaCad Mobile Release 2.0 is a web based device that can be used on PCs, Mac, or iPad 3, 4 or 5 (Air) and interacts with a PACS system or Quentry. No installation is required. TraumaCad Mobile Release 2.0 provides web based access and should only be used on computers and iPads that are already qualified for wireless use in a clinical setting. TraumaCad Mobile Release 2.0 is not intended for use on mobile phones. Use of TraumaCad Mobile Release 2.0 for planning on a tablet is not to replace planning on a workstation. Use on a tablet is only for situations when a workstation is not available.

    AI/ML Overview

    This document, a 510(k) summary for TraumaCad Mobile Release 2.0, provides information on comparative testing but does not explicitly define acceptance criteria for performance metrics or present a formal study proving the device meets acceptance criteria. Instead, it focuses on demonstrating substantial equivalence to predicate devices through various tests.

    Here's a breakdown of the provided information, addressing your questions where possible:

    1. Table of Acceptance Criteria and Reported Device Performance

    The document does not specify formal "acceptance criteria" with quantitative thresholds (e.g., minimum accuracy, maximum error). Instead, it states that "the test shows that the predicate device TraumaCad 2.0 and TraumaCad Mobile have the same expected results in all of the tests" when comparing marker detection, calibration results, and template positioning. This implies an internal acceptance criterion of equivalence to the predicate device.

    Parameter/Character TestedAcceptance Criteria (Implied)Reported Device Performance
    Marker detectionSame expected results as predicate device TraumaCad 2.0Achieved same expected results as predicate device TraumaCad 2.0
    Calibration resultSame expected results as predicate device TraumaCad 2.0Achieved same expected results as predicate device TraumaCad 2.0
    Templates positioningSame expected results as predicate device TraumaCad 2.0Achieved same expected results as predicate device TraumaCad 2.0
    UsabilitySimulated clinical environment, pre-operative planning, and functional testing demonstrates satisfactory performanceTesting performed on Hip and Knee procedures; primary operating functions tested in a clinical environment; most participants familiar with predicate device workflow. Implied satisfactory usability.
    Non-clinical testingSafety and effectiveness demonstrated for defined indications of use, performs as well as or better than predicate deviceSuccessful non-clinical testing demonstrates safety and effectiveness and performance as well as or better than the legally marketed predicate device.

    2. Sample Size Used for the Test Set and Data Provenance

    • Test Set Sample Size: The document repeatedly mentions "various medical images from a range of cases," "various Hip X-rays," and "various knee images." However, no specific numerical sample size for the test set is provided.
    • Data Provenance: The images are described as "pre-obtained digital images via PACS system or via Quentry." This suggests retrospective data collected from typical clinical archives. There is no information about the country of origin of the data.

    3. Number of Experts Used to Establish Ground Truth for the Test Set and Qualifications

    The document does not specify the number of experts used to establish ground truth or their qualifications. The tests involved comparing the subject device's results to those of the predicate device (TraumaCad 2.0), implying the predicate device's output or methods serve as a form of reference, but not explicitly a human-established ground truth for each case.

    4. Adjudication Method for the Test Set

    The document does not describe an explicit adjudication method (e.g., 2+1, 3+1). The testing involved "comparing TraumaCad 2.0 on a PC device and TraumaCad Mobile on an iPad device," suggesting a direct comparison of outputs rather than an independent expert adjudication process for each case.

    5. Multi-Reader Multi-Case (MRMC) Comparative Effectiveness Study and Effect Size

    No MRMC comparative effectiveness study is reported. The focus is on the device's functional equivalence to the predicate, not on how human readers' performance improves with or without the AI assistance of TraumaCad Mobile.

    6. Standalone (Algorithm Only) Performance Study

    The reported testing focuses on the device's functionality, including "Marker detection, Calibration result and Templates positioning," and compares these directly to the predicate device's performance. This implies a form of standalone performance evaluation in the sense that the device's algorithms are being assessed for their output equivalence to an established system without necessarily involving human interpretation as the primary outcome being measured. The product is described as "assisting healthcare professionals," so while the tests evaluate the algorithm's output, it's within the context of a human-in-the-loop workflow.

    7. Type of Ground Truth Used

    The "ground truth" implicitly used for the functional tests such as marker detection, calibration, and template positioning is the output generated by the predicate device, TraumaCad 2.0. For usability, the "ground truth" would be the successful completion of tasks and overall user satisfaction, observed during the simulated clinical environment testing. There is no mention of pathology or outcomes data being used as ground truth for these specific tests.

    8. Sample Size for the Training Set

    The document does not provide any information regarding the sample size used for the training set. It mentions that "The algorithms contained on TraumaCad Mobile are the same as those that are in the predicate device TraumaCad 2.0 that have been extensively tested," suggesting that the underlying algorithms were developed and likely trained prior to this specific device iteration, possibly with data associated with TraumaCad 2.0.

    9. How the Ground Truth for the Training Set Was Established

    Since no specific training set information is provided, how the ground truth for an (unspecified) training set was established is not detailed. The statement about the algorithms being the same as in the predicate device (TraumaCad 2.0) suggests that any previous ground truth establishment for those algorithms would have occurred during the development and testing of TraumaCad 2.0.

    Ask a Question

    Ask a specific question about this device

    K Number
    K142923

    Validate with FDA (Live)

    Manufacturer
    Date Cleared
    2015-03-05

    (148 days)

    Product Code
    Regulation Number
    892.2050
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The TraumaCad Mobile Release 1.0 program is indicated for assisting healthcare professionals in preoperative planning of orthopedic surgery. The device allows for overlaying of prosthesis templates on radiological images, and includes tools for performing measurements on the image and for positioning the template. Clinical judgment and experience are required to properly use the software is not for primary image interpretation. The software is not for use on mobile phones.

    Device Description

    TraumaCad Mobile Release 1.0 allows surqeons to evaluate digital images while performing various pre-operative surgical planning and evaluation of images. This software application enables surgeons to plan operations on screen, execute measurements, and facilitate the film-less orthopedic practice. The program features full PACS integration and an extensive reqularly updated library of digital templates from leading manufacturers. TraumaCad Mobile Release 1.0 supports DICOM and enables the importing and exporting of image files from a central PACS system, or Quentry (Class I device reqistered by Brainlab AG in the FDA).

    TraumaCad Mobile Release 1.0 is the web based version of the predicate device TraumaCad 2.0 (cleared by the FDA on March 19, 2008). The TraumaCad Mobile Release 1.0 has the same basic functionality and intended use as the predicate device, but is now available as a web based version on additional platforms. The differences between the device and the predicate device do not impact on substantial equivalence.

    TraumaCad Mobile Release 1.0 is a web based device that can be used on PCs, Mac, or iPad 3, 4 or 5 (Air) and interacts with a PACS system or Quentry. No installation is required. TraumaCad Mobile Release 1.0 provides web based access and should only be used on computers and iPads that are already qualified for wireless use in a clinical setting. TraumaCad Mobile is not intended for use on mobile phones. Use of TraumaCad Mobile for planning on a tablet is not to replace planning on a workstation. Use on a tablet is only for situations when a workstation is not available.

    In order to access TraumaCad Mobile, the user needs to browse to a specific URL and enter the system via username and password. A Web Application will be available in the iTunes store that will automatically open the browser with the correct URL. The application can be downloaded from iTunes for free but cannot be used without receiving a license to ensure the use by appropriate healthcare professionals.

    The program features full PACS integration and an extensive reqularly updated library of digital templates from leading manufacturers. TraumaCad Mobile supports DICOM and enables the importing and exporting image files from a central PACS system or from Quentry.

    AI/ML Overview

    The provided document describes the 510(k) premarket notification for TraumaCad Mobile Release 1.0. This device is a web-based version of the previously cleared TraumaCad 2.0 and is intended for assisting healthcare professionals in preoperative planning of orthopedic surgery.

    The document does not explicitly state "acceptance criteria" and "reported device performance" in a formal table format as requested. Instead, it focuses on demonstrating substantial equivalence to a predicate device (TraumaCad 2.0) through functional testing, comparison of technological characteristics, and usability testing. The "acceptance criteria" can be inferred from the successful outcome of these tests, implying that the new device performs "as well as or better than the legally marketed predicate device."

    Here's an analysis of the study and information provided:

    1. Table of Acceptance Criteria and Reported Device Performance:

    The document doesn't provide a specific table of quantitative acceptance criteria with numerical performance targets and reported values. Instead, it asserts that the TraumaCad Mobile Release 1.0 performs comparably to its predicate device, TraumaCad 2.0, across its shared functionalities.

    Acceptance Criteria (Inferred from testing)Reported Device Performance (TraumaCad Mobile Release 1.0)
    Functional Equivalence to Predicate Device:
    - Marker detection accuracySame expected results as TraumaCad 2.0
    - Calibration result accuracySame expected results as TraumaCad 2.0
    - Template positioning accuracySame expected results as TraumaCad 2.0
    - Image selection from Quentry/PACSSuccessfully performed
    - Image calibrationSuccessfully performed
    - Implant selectionSuccessfully performed
    - Evaluation of LLD and offset changesSuccessfully performed
    - Changing implant propertiesSuccessfully performed
    - Use of measurement toolsSuccessfully performed
    - Saving results to Quentry/PACSSuccessfully performed
    Safety and Effectiveness:Successfully demonstrated through non-clinical testing
    Risk Mitigation:New risk control measures implemented and deemed effective for the mobile environment
    System Stability/Reliability:Passed unit, system/integration, and acceptance tests including security, negative testing, error handling, stress testing, platform testing, workflow testing, functional testing, multi-user/external access testing, data integrity testing, compatibility testing, load testing, regression testing, and hazard mitigation testing.
    Usability: (Inferred from Usability Testing)Successfully performed preoperative planning on various Hip X-rays, with familiar workflow for users of the predicate device.

    2. Sample Size Used for the Test Set and Data Provenance:

    • Test Set Sample Size: The document does not specify a numerical sample size for the test set (number of cases or images). It mentions "various medical images from a range of cases" and "various Hip X-rays" for usability testing.
    • Data Provenance: The document implies the use of existing digital images from PACS systems or Quentry. The country of origin is not explicitly stated. The nature of the study appears to be retrospective as it uses pre-obtained digital images for testing the software's functionality and comparison.

    3. Number of Experts Used to Establish the Ground Truth for the Test Set and Qualifications:

    • The document does not explicitly state the number of experts used to establish ground truth or their specific qualifications (e.g., radiologist with X years of experience).
    • It states that "Clinical judgment and experience are required to properly use the software" as part of its indications for use, implying that healthcare professionals with relevant expertise would interpret the results.
    • The testing compared the results of TraumaCad Mobile with TraumaCad 2.0, suggesting the "ground truth" for the comparison was based on the performance of the predicate device, which would have been validated by experts previously.

    4. Adjudication Method for the Test Set:

    • The document does not describe a formal adjudication method (e.g., 2+1, 3+1).
    • The comparison involved running tests in parallel on TraumaCad Mobile and the predicate device TraumaCad 2.0 and observing if they yielded "the same expected results." This implies a direct comparison rather than an expert consensus adjudication on individual cases.

    5. Multi-Reader Multi-Case (MRMC) Comparative Effectiveness Study:

    • No, an MRMC comparative effectiveness study was not explicitly described. The study focused on demonstrating substantial equivalence between TraumaCad Mobile and its predicate device, TraumaCad 2.0.
    • While usability testing involved test participants (who may be healthcare professionals and potentially users of the predicate device), the document does not present data on how much human readers improve with AI (TraumaCad Mobile) vs. without AI assistance (presumably manual planning or planning with the predicate device) in a formal MRMC study design to determine an effect size.

    6. Standalone Performance:

    • Yes, a standalone (algorithm only without human-in-the-loop performance) evaluation was effectively performed for the core algorithms. The document states: "The algorithms contained on TraumaCad Mobile are the same as those that are in the predicate device TraumaCad 2.0 that have been extensively tested." And "Testing included the main functions such as: Marker detection, Calibration result and Templates positioning. The test shows that the predicate device TraumaCad and TraumaCad Mobile have the same expected results in all of the tests." This suggests that the inherent algorithmic performance for these functions was compared in a standalone manner.
    • However, the device is explicitly indicated for "assisting healthcare professionals," meaning human-in-the-loop is part of its intended use. The usability testing further underscores the interaction with humans.

    7. Type of Ground Truth Used:

    • The ground truth for the functional comparison testing was primarily based on the expected results from the predicate device (TraumaCad 2.0). The document states that the new device and the predicate device "have the same expected results in all of the tests."
    • For the initial validation of the predicate device (TraumaCad 2.0) and the underlying algorithms, it is highly probable that expert consensus (e.g., orthopedic surgeons, radiologists) and potentially comparison against surgical outcomes data or pathology (if applicable for certain measurements) would have been used. However, for this specific 510(k), the ground truth is anchored to the performance of the already-cleared predicate device.

    8. Sample Size for the Training Set:

    • The document does not provide any information regarding a training set sample size. This is because TraumaCad Mobile Release 1.0 is largely a porting of existing, already-trained algorithms from TraumaCad 2.0 to new platforms (web-based, iPad, Mac). It's not a new machine learning algorithm that requires a separate training phase with new data. The document explicitly states: "The algorithms contained on TraumaCad Mobile are the same as those that are in the predicate device TraumaCad 2.0 that have been extensively tested."

    9. How the Ground Truth for the Training Set Was Established:

    • As there's no mention of a new training set for TraumaCad Mobile 1.0, there's no information on how its ground truth would have been established.
    • For the original TraumaCad 2.0 and its algorithms (from which TraumaCad Mobile's algorithms are derived), the ground truth for training (if machine learning was involved, which is not explicitly stated in this document but is common for such systems) would typically be established through expert consensus by orthopedic surgeons or radiologists, potentially using manually annotated anatomical landmarks, measurements, or templating results validated against surgical outcomes or physical measurements.