Search Filters

Search Results

Found 2 results

510(k) Data Aggregation

    K Number
    K190155

    Validate with FDA (Live)

    Date Cleared
    2019-02-27

    (28 days)

    Product Code
    Regulation Number
    892.5050
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    N/A
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The FibermarX™ Radiopaque Tissue Marker is intended to be implanted into the body to accurately visualize and constitute the reference frame for stereotactic radiosurgery and radiotherapy target localization. In addition, the markers are indicated in situations where tissue needs to be marked for future medical procedures such as IMRT/IGRT.

    Device Description

    The device is a sterile, single-patient-use, barium sulfate infused non-absorbable polymer monofilament that is visible on standard radiographs (x-ray, CT, mammography). FibermarX™ is passed through soft tissue and tied into place during open, percutaneous, or arthroscopic/laparoscopic/endoscopic procedures and standard surgeon's knots or a continuous running outline are used to quickly mark the soft tissue for subsequent imaging or for radiotherapy target localization.

    AI/ML Overview

    The provided document is a 510(k) premarket notification for a medical device called the FibermarX™ Radiopaque Tissue Marker. This type of submission focuses on demonstrating substantial equivalence to a legally marketed predicate device rather than providing extensive clinical study data that would typically include detailed acceptance criteria and performance metrics of the new device in a standalone clinical trial.

    Therefore, the document does not contain the requested information regarding acceptance criteria and a study that proves the device meets those criteria in the context of a comparative effectiveness study, standalone AI algorithm performance, or using experts to establish ground truth. The submission focuses on non-clinical testing to demonstrate substantial equivalence to a predicate device.

    Here's a breakdown of what can be extracted or inferred from the document based on the standard 510(k) submission process:


    1. A table of acceptance criteria and the reported device performance

    The document does not provide a formal table of acceptance criteria and reported device performance in the manner one would see for a clinical trial or AI algorithm validation. Instead, it describes non-clinical tests conducted to support substantial equivalence. The "performance" is generally demonstrated by showing that the device is comparable to the predicate device in specific aspects.

    Inferred "Acceptance Criteria" (based on non-clinical tests) and "Reported Device Performance":

    Acceptance Criteria (Inferred from testing)Reported Device Performance (Summary from submission)
    Biocompatibility: No cytotoxicity, irritation, sensitization, systemic toxicity, and non-pyrogenic.Passed ISO 10993 biocompatibility testing (cytotoxicity, Intracutaneous irritation, sensitization, intramuscular implantation, pyrogenicity, and acute systemic toxicity) and toxicological risk assessment of extractables.
    Material Safety: Extractables are within safe limits.Extractables analyzed using GC-MS, LC-MS, and ICP-MS showed safety.
    Sterility: Achieve a Sterility Assurance Level (SAL) of 10^-6.Sterilization resistance and bioburden testing determined proper EO parameters to achieve 10^-6 SAL.
    Radiographic Visibility: Visible on standard radiographs (x-ray, CT, mammography) and comparable to predicate.CT/x-ray radiographic imaging at low, medium, and high doses and mammography showed substantially equivalent radiographic visualization to the predicate device.
    Shelf-Life & Packaging Integrity: Maintain performance over shelf-life and packaging suitable.Packaging validation and post shelf-life performance testing conducted.
    Radiation Impact: Mechanical properties, visibility, and cytotoxicity unaffected by radiation exposure (for radiotherapy applications).Evaluation of radiation impact on mechanical properties, visibility, and cytotoxicity showed no negative impacts.

    2. Sample size used for the test set and the data provenance (e.g. country of origin of the data, retrospective or prospective)

    • Sample Size for Test Set: Not applicable in the context of human data. The "test set" here refers to physical samples of the device used for non-clinical testing (e.g., individual markers for biocompatibility, imaging, and radiation impact). The specific number of physical units tested is not detailed, but it would have been sufficient for the conducted non-clinical tests.
    • Data Provenance: Not applicable as this is non-clinical testing of the device itself, not human data. The tests were performed by the manufacturer or a contracted lab.

    3. Number of experts used to establish the ground truth for the test set and the qualifications of those experts (e.g. radiologist with 10 years of experience)

    • Number of Experts: Not applicable. Ground truth, in the context of clinical or AI studies, is not established for non-clinical device testing. The results of the physical tests are the "ground truth" for the device's characteristics.

    4. Adjudication method (e.g. 2+1, 3+1, none) for the test set

    • Adjudication Method: Not applicable. This concept applies to expert review of clinical data, which is not part of this 510(k) non-clinical submission.

    5. If a multi reader multi case (MRMC) comparative effectiveness study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance

    • MRMC Comparative Effectiveness Study: No, an MRMC comparative effectiveness study was not conducted and is not mentioned. This type of study would be relevant for evaluating diagnostic imaging devices or AI-assisted systems reading images from human patients, which is not the nature of this device or its submission.

    6. If a standalone (i.e. algorithm only without human-in-the loop performance) was done

    • Standalone Performance: No, a standalone algorithm performance study was not done. This device is a physical tissue marker, not an algorithm.

    7. The type of ground truth used (expert consensus, pathology, outcomes data, etc)

    • Type of Ground Truth: For the non-clinical tests, the "ground truth" is derived from objective, quantitative measurements and laboratory analyses (e.g., chemical analysis results for extractables, physical measurements for mechanical properties after radiation, optical/imaging assessments of visibility).

    8. The sample size for the training set

    • Sample Size for Training Set: Not applicable. This device is not an AI algorithm, so there is no training set in the conventional sense.

    9. How the ground truth for the training set was established

    • Ground Truth for Training Set Establishment: Not applicable, as there is no training set for this device.
    Ask a Question

    Ask a specific question about this device

    K Number
    K170026

    Validate with FDA (Live)

    Date Cleared
    2017-06-02

    (150 days)

    Product Code
    Regulation Number
    878.4300
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    N/A
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The Radiopaque Tissue Marker is indicated for use to radiographically mark soft tissue during a surgical procedure or for future surgical procedures.

    Device Description

    The device is a sterile, single-patient-use, barium sulfate infused polypropylene suture that is radiopaque using standard radiographs (x-ray, mammography). The device is placed into soft tissue sites during open, percutaneous, or endoscopic procedures and standard surgeon's knots are tied to quickly and inexpensively mark the soft tissue so that the integrity and location of the marked soft tissue can be evaluated.

    AI/ML Overview

    This document is a 510(k) summary for a medical device called a "Radiopaque Tissue Marker." It outlines the device's characteristics, its intended use, and the non-clinical testing performed to establish substantial equivalence to a predicate device.

    Here's an analysis based on the provided text, addressing your questions:

    1. A table of acceptance criteria and the reported device performance

    The document does not explicitly state "acceptance criteria" in a quantitative format with corresponding reported performance metrics for the device. Instead, it describes non-clinical tests performed to demonstrate substantial equivalence to a predicate device. The performance is assessed against the predicate device, not against specific, pre-defined numerical thresholds for accuracy, sensitivity, or specificity.

    However, based on the non-clinical testing mentioned, we can infer performance aspects:

    Acceptance Criteria (Implied)Reported Device Performance
    Biocompatibility: Device is safe for implantation and does not cause adverse biological reactions.Biocompatibility: Showed that the subject device is biocompatible and non-pyrogenic, based on ISO 10993 testing (cytotoxicity, intracutaneous irritation, sensitization, intramuscular implantation, pyrogenicity, and acute systemic toxicity) and toxicological risk assessment of extractables.
    Sterility: Device is sterile at the time of use.Sterility: Ethylene oxide sterilization parameters were determined to achieve a sterilization assurance level of 10^-6, supported by sterilization resistance and bioburden testing.
    Radiographic Visualization: Device is visible under standard radiological imaging (x-ray, mammography).Radiographic Visualization: CT/x-ray radiographic imaging at low, medium, and high doses and mammography of implanted subject and predicate devices showed "substantially equivalent radiographic visualization" to the Cassi Beacon Tissue Marker.
    Mechanical Properties (Implied for Suture): Sufficient tensile strength for placement and knot tying.Mechanical Properties: Polypropylene was chosen as the polymer base due to its "ability to be extruded and processed to increase tensile strength, which is required for placement and knot tying." (This is a design choice to meet a functional requirement, rather than a direct test result).
    Shelf-Life and Packaging Integrity: Device maintains performance and sterility over its shelf life and is protected by its packaging.Shelf-Life and Packaging Integrity: Packaging validation and post shelf-life performance was also tested. (No specific results provided, only that it was tested).
    Chemical Composition/Safety of Extractables: No harmful leachable substances.Chemical Composition/Safety of Extractables: Extractables were analyzed using GC-MS, LC-MS, and ICP-MS, and a toxicological risk assessment was performed.

    2. Sample size used for the test set and the data provenance (e.g. country of origin of the data, retrospective or prospective)

    The document describes non-clinical laboratory testing. It does not mention a "test set" in the context of patient data, nor does it specify any sample sizes for patients or data provenance (country of origin, retrospective/prospective). The testing involved physical devices and materials, not patient data in the way one would analyze for an AI algorithm.

    3. Number of experts used to establish the ground truth for the test set and the qualifications of those experts (e.g. radiologist with 10 years of experience)

    This is not applicable to the study described. The study involves non-clinical testing of a physical device. There is no "ground truth" establishment in the context of expert consensus on medical images or diagnoses.

    4. Adjudication method (e.g. 2+1, 3+1, none) for the test set

    This is not applicable for the study described. There is no "test set" of patient data requiring adjudication of ground truth by multiple experts.

    5. If a multi reader multi case (MRMC) comparative effectiveness study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance

    No MRMC study was performed. The device is a physical radiopaque tissue marker, not an AI algorithm. Therefore, an "effect size of human readers improve with AI vs without AI assistance" is not relevant.

    6. If a standalone (i.e. algorithm only without human-in-the-loop performance) was done

    No standalone algorithm performance study was done. The device is a physical radiopaque tissue marker, not an AI algorithm.

    7. The type of ground truth used (expert consensus, pathology, outcomes data, etc)

    This is not applicable for the study described. The "ground truth" for non-clinical device testing would be the physical and chemical properties of the materials and their behavior under controlled laboratory conditions, as measured by standard testing methods (e.g., ISO 10993 for biocompatibility, specific imaging protocols for radiopacity). It is not based on expert consensus, pathology, or outcomes data related to patient diagnosis.

    8. The sample size for the training set

    This is not applicable. The device is a physical medical device, not an AI algorithm that requires a "training set."

    9. How the ground truth for the training set was established

    This is not applicable. There is no AI algorithm or training set associated with this device.

    Ask a Question

    Ask a specific question about this device

    Page 1 of 1