510(k) Data Aggregation

    K Number
    K252845

    Validate with FDA (Live)

    Manufacturer
    Date Cleared
    2025-11-06

    (59 days)

    Product Code
    Regulation Number
    878.4400
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    N/A
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The Venus Nova device is intended for the treatment of the following medical conditions using the 4D Body (MP2) applicator for delivery of RF energy combined with massage and magnetic field pulses:

    • Relief of minor muscle aches and pain, relief of muscle spasm
    • Temporary improvement of local blood circulation
    • Temporary reduction in the appearance of cellulite

    When used with the Octipolar (LB1) or Diamondpolar (LF1) applicators, the Venus Nova device is intended for use in dermatologic and general surgical procedures for females for the non-invasive treatment of moderate to severe facial wrinkles and rhytides in Fitzpatrick skin types I-IV.

    In addition, the Venus Nova device using the FlexMAX applicators is intended for muscle conditioning to stimulate healthy muscles.

    The Venus Nova device using the FlexMAX applicators is not intended to be used in conjunction with therapy or treatment of medical diseases or medical conditions of any kind.

    The Venus Nova device using the FlexMAX applicators is intended to be operated by a trained professional.

    Device Description

    The Venus Nova device is a computerized device comprised of a console (main unit), one (1) 4D Body applicator containing RF, PEMF and Vacuum, one (1) Octipolar applicator for large anatomical areas containing RF and PEMF, one (1) Diamondpolar applicators for smaller anatomical areas containing RF and PEMF and four (4) FlexMAX applicators containing Electrical Muscle Stimulation (EMS). The device delivers bipolar RF and biphasic electrical energies, vacuum pressure, and pulsed electromagnetic fields (PEMF) to the skin and the underlying tissues of the treatment area. The device provides individual adjustment of EMS intensity level, and RF power, in addition to vacuum levels, for each patient.

    The console of the Venus Nova device contains a power supply unit, RF and EMS controllers, (power modules, on main board), a suction module (vacuum), a controller unit (on main board), a touch-screen user interface and display panel.

    The applicators are connected to the console via cables. The RF applicators are comprised of various combinations of RF electrodes, magnetic coils, and vacuum conduits. The EMS applicators are comprised of two electrodes each and a light indicator.

    AI/ML Overview

    N/A

    Ask a Question

    Ask a specific question about this device

    K Number
    K232192

    Validate with FDA (Live)

    Manufacturer
    Date Cleared
    2023-09-11

    (49 days)

    Product Code
    Regulation Number
    878.4810
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    N/A
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The Venus Versa PRO System is a multi-application device intended to be used in aesthetic and cosmetic procedures.

    The SR515 and SR580 IPL applicators are indicated for the following:

    · Treatment of benign pigmented epidermal and cutaneous lesions including: hyperpigmentation, melasma, ephelides (freckles), lentigines, nevi, and cafe-au-lait macules.

    · Treatment of benign cutaneous vascular lesions including port wine stains, hemangiomas, facial, truncal and leg telangiectasias, rosacea, angiomas, poikiloderma of civatte, leg veins and venous malformations.

    The HR650, HR650XL, and HR690XL IPL applicators are indicated for the removal of unwanted hair and to effect stable long-term or permanent hair reduction for skin types I-IV. Permanent hair reduction is defined as the longterm stable reduction in the number of hairs regrowing when measured at 6, 9, and 12 months after the completion of a treatment regimen.

    The Venus Concept ACDUAL applicator is intended to be used for the treatment of acne vulgaris.

    The Diamondpolar and Octipolar applicators are non-invasive devices intended for use in dermatologic and general surgery procedures for females for the non-invasive treatment of moderate to severe facial wrinkles in Fitzpatrick skin types I-IV.

    The Viva MD applicator is intended for dermatological procedures requiring ablation and resurfacing of the skin.

    Device Description

    The Venus Versa PRO System is comprised of a console (controller/CPU) and ten detachable handpieces (applicators) and two disposable tips. The system can deliver three types of energies to the patient's skin using the associated ten applicators:

    • Intense Pulsed Light (IPL)
    • Magnetic Pulse (MP2)
    • Radiofrequency (RF)
    AI/ML Overview

    The provided document is a 510(k) summary for the Venus Versa PRO System. It outlines the device's technical characteristics and compares them to a predicate device and a reference device to demonstrate substantial equivalence. Crucially, this document explicitly states that no clinical studies were deemed necessary because the changes were minor and did not introduce new safety or effectiveness issues.

    Therefore, I cannot provide details on acceptance criteria and a study proving the device meets them based on this document alone, as no such clinical study was performed or required for this 510(k) submission.

    However, I can extract and summarize the information typically requested for such a description, framing it within the context of why certain elements (like performance metrics, sample sizes, expert adjudication, MRMC studies, and detailed ground truth establishment for a test set) are absent here.

    Here's a breakdown of the requested information, explaining what is present in the document and what is not due to the nature of this 510(k) submission:


    Acceptance Criteria and Study Proving Device Meets Acceptance Criteria for Venus Versa PRO System (K232192)

    Based on the provided 510(k) summary, the substantial equivalence determination for the Venus Versa PRO System was primarily based on technical equivalence to a predicate device (Venus Versa System, K153717) and a reference device (Venus Viva MD Device, K201164), rather than a new clinical performance study with defined acceptance criteria for a novel device or AI.

    The document states: "Based on the similarities in the safety and effectiveness profiles of the subject and the predicate, no clinical studies were deemed needed to support this submission." This indicates that the "acceptance criteria" were met by demonstrating that the Venus Versa PRO System did not introduce new safety or effectiveness concerns compared to its legally marketed predecessors and that its technical specifications were largely identical or within acceptable ranges.

    1. Table of Acceptance Criteria and Reported Device Performance

    Since no new clinical performance study was conducted for this 510(k) submission, there isn't a table of "acceptance criteria" and "reported device performance" in the traditional sense of a clinical trial for a novel device or an AI.

    Instead, the "acceptance criteria" were implicit in demonstrating substantial equivalence through technical comparisons. The "reported device performance" is essentially the device's adherence to those technical specifications, which are identical or equivalent to the predicate devices.

    Feature / CharacteristicAcceptance Criteria (from Predicate/Reference)Reported Device Performance (Venus Versa PRO System)
    Intended UseIdentical to Predicate/ReferenceIdentical
    Regulation ClassClass II, ONF, GEX, GEIClass II, ONF, GEX, GEI
    Energy Type (IPL)Identical to PredicateIdentical (IPL)
    IPL SpectrumIdentical to PredicateIdentical (Lesions, Hair Removal, Acne spectra)
    Frequency (IPL)Identical to PredicateIdentical (Up to 3 Hz / Up to 2 Hz)
    Spot Size (IPL)Identical to PredicateIdentical (10x30mm, 20x30mm)
    Pulse Duration (IPL)Identical to PredicateIdentical (5-20ms, 20-50ms)
    Energy Density (IPL)Identical to PredicateIdentical (5-25 J/cm², 5-20 J/cm²)
    Energy Type (RF/MP2)Identical to PredicateIdentical (Bipolar RF, PMF)
    Max RF Output Power (RF/MP2)Identical to PredicateIdentical (Diamondpolar: 75W, Octipolar: 150W)
    RF Output Frequency (RF/MP2)Identical to PredicateIdentical (1 MHz)
    Magnetic Pulse FrequencyIdentical to PredicateIdentical (15 Hz)
    Magnetic FieldIdentical to PredicateIdentical (Up to 15 Gauss)
    Energy Type (Fractional RF)Identical to Predicate/ReferenceIdentical (Fractional RF)
    Max RF Energy (Viva MD)62 mJ/pin (160 pin tip)62 mJ/pin (160 pin tip)
    124 mJ/pin (80 pin tip from Reference)124 mJ/pin (80 pin tip)
    Max RF Output Power (Viva MD)Identical to Predicate/ReferenceIdentical (8W)
    Energy Density (Viva MD)Identical to Predicate/ReferenceIdentical (7.5 J/cm²)
    Tip Number of Pins (Viva MD)160 pins (from Predicate)160 pins
    80 pins (from Reference)80 pins
    RF Output Frequency (Viva MD)Identical to Predicate/ReferenceIdentical (0.46 MHz)
    Electrical Safety (IEC 60601-1)Compliance with standardConfirmed compliance (changes did not affect results)
    EMC (IEC 60601-1-2)Compliance with standardConfirmed compliance (changes did not affect results)
    Bench Testing (80 pin tip)Deliver same output power as predicateVerified and passed
    Software Verification & ValidationFunction as intendedPerformed and passed
    BiocompatibilitySame product material as predicateConfirmed same material

    2. Sample size used for the test set and the data provenance:

    • Sample Size: Not applicable as no clinical test set was used for performance evaluation in this 510(k) due to the nature of the submission (demonstrating substantial equivalence through technical comparisons). Bench testing was conducted for the 80 pin tip.
    • Data Provenance: Not applicable for a clinical test set. The technical data is generated internally from Venus Concept Inc.

    3. Number of experts used to establish the ground truth for the test set and the qualifications of those experts:

    • Not applicable as no clinical test set requiring expert ground truth was used for this 510(k). The regulatory decision was based on technical equivalence.

    4. Adjudication method (e.g., 2+1, 3+1, none) for the test set:

    • Not applicable as no clinical test set requiring adjudication was used for this 510(k).

    5. If a multi reader multi case (MRMC) comparative effectiveness study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance:

    • Not applicable. This device is a laser/light-based medical instrument for aesthetic procedures, not an AI-assisted diagnostic device. Therefore, no MRMC study or AI assistance evaluation was performed.

    6. If a standalone (i.e., algorithm only without human-in-the-loop performance) was done:

    • Not applicable. This device is a hardware system, not a standalone algorithm.

    7. The type of ground truth used (expert consensus, pathology, outcomes data, etc.):

    • Not applicable for a clinical performance study. The "ground truth" for this submission was the established safety and effectiveness of the legally marketed predicate and reference devices, as well as bench test results for the specific new feature (80-pin tip).

    8. The sample size for the training set:

    • Not applicable. This document describes a medical device (laser/light system), not an AI/ML algorithm that requires a training set.

    9. How the ground truth for the training set was established:

    • Not applicable. This document describes a medical device (laser/light system), not an AI/ML algorithm.