The Tenon Medical Catamaran SI Joint Fusion System is intended for sacroiliac joint fusion for conditions including:
- Sacroiliac joint disruptions and degenerative sacroiliitis
- To augment immobilization and stabilization of the sacroiliac joint in skeletally mature patients undergoing sacropelvic fixation as part of a lumbar or thoracolumbar fusion.
The Catamaran SI Joint Fusion System is intended for sacroiliac joint fusion for conditions including sacroiliac joint disruptions and degenerative sacroiliitis. The Catamaran SI Joint Fusion System was developed as a less invasive alternative to traditional open posterior surgical SI Joint fusion. The system consists of the Catamaran SI Joint Fixation Implant (Ti6A1-4V ELI Titanium alloy / ASTM F136) included in a reusable System Tray containing: Access, Drill and Delivery, Bone Graft Packing, and Extraction Instruments. The Catamaran SI Joint Fixation Implants are designed in various widths and lengths, and allow autologous bone graft material placement in the barrels of the implant to support SI Joint fixation and fusion. The Instrument Set includes Class II single use and reusable surgical instruments designed to facilitate placement of the implant within the sacroiliac joint using an inferior-posterior surgical approach. The implants and associated instruments are provided clean and non-sterile and are designed for steam sterilization prior to use.
This document is a 510(k) Premarket Notification from the FDA regarding the Tenon Medical CATAMARAN™ SI Joint Fusion System. Based on the provided text, the submission does not include any study data relating to the performance of an AI/ML medical device.
The central point of this 510(k) submission is a change in the Indications for Use for an already cleared device. The text explicitly states:
- "The sole purpose of this submission is to modify the indications for use." ([Page 5])
- "No clinical or non-clinical performance testing was necessary to support the change in indications for use proposed." ([Page 5])
Therefore, I cannot extract the information required by your request about acceptance criteria and a study proving a device meets them, as this document concerns a change to an existing device's labeling and did not involve new performance testing.
If you have a document related to an AI/ML device approval that includes performance study data, please provide that.
Ask a specific question about this device
(55 days)
The Tenon Medical CATAMARAN™ SI Joint Fusion System is intended for sacroillac joint fusion for conditions including sacroiliac joint disruptions and degenerative sacroillitis.
The CATAMARAN SI Joint Fusion System is intended for sacroillac joint fusion for conditions including sacroiliac joint disruptions and degenerative sacroillitis. The CATAMARAN SI Joint Fusion System was developed as a less invasive alternative to traditional open posterior surgical SI Joint fusion. The system consists of the CATAMARAN SI Joint Fixation Implant (Ti6A1-4V ELI Titanium alloy / ASTM F136) included in a reusable System Tray containing: Access, Drill and Delivery, Bone Graft Packing, and Extraction Instruments. The CATAMARAN SI Joint Fixation Implants are designed in various widths and lengths, and allow autologous bone graft material placement in the barrels of the implant to support SI Joint fixation and fusion. The Instrument Set includes Class II single use and reusable surgical instruments designed to facilitate placement of the implant within the sacroillac joint using an inferiorposterior surgical approach. The implants and associated instruments are provided clean and non-sterile and are designed for steam sterilization prior to use.
The provided text is a 510(k) summary for a medical device (CATAMARAN™ SI Joint Fusion System) and does not contain information about studies evaluating an AI/ML-driven device, particularly regarding acceptance criteria, sample sizes for test/training sets, expert involvement, or MRMC studies.
Therefore, it is impossible to describe "the acceptance criteria and the study that proves the device meets the acceptance criteria" in the context of AI/ML performance from the provided document. The document primarily focuses on demonstrating substantial equivalence to a predicate device, and the "study" mentioned pertains to MR compatibility testing, not clinical performance or AI/ML algorithm validation.
The "Design Verification Standards Testing" section (page 5) lists ASTM standards for MR compatibility assessment. This is a crucial part of the device's validation but doesn't involve the kind of performance metrics or expert reviews associated with AI/ML diagnostic or prognostic tools.
The prompt's request for information on "acceptance criteria and the study that proves the device meets the acceptance criteria" (specifically for an AI/ML device), along with details like "sample size used for the test set," "number of experts," "adjudication method," "MRMC study," "standalone performance," "ground truth type," and "training set details," cannot be addressed using the provided text.
Ask a specific question about this device
(76 days)
The Tenon Medical Catamaran Sacroiliac Joint Fixation System) is intended for sacroiliac joint fusion for conditions including sacroiliac joint disruptions and degenerative sacroiliitis.
The Tenon Medical Catamaran Sacroiliac Joint Fixation System (CAT SIJ Fixation System) was developed as a less invasive alternative to traditional open posterior surqical SIJ fusion. The Tenon Medical Catamaran Sacroillac Joint Fixation System (CAT SIJ Fixation System) includes the Catamaran SIJ Implant and associated surgical instruments: an Access Set, a Drill/Delivery and an Accessory Set and an Extraction Set. The titanium implant consists of two hollow barrels connected by a bridge. During the procedure, autologous bone graft material is placed in the barrel of the implant to facilitate stabilization. The Catamaran SIJ Implant is available in two (2) different barrel diameters (7.5mm and 10mm) and two implant lengths (30mm and 40mm) for a total of four sizing options to fit patient anatomy. The Catamaran SIJ Implant is intended for single-use only. The implants and associated components are provided clean and non-sterile and designed for routine steam sterilization prior to use.
This document describes the Tenon Medical Catamaran Sacroiliac Joint Fixation System (CAT SIJ Fixation System). It is a medical device for sacroiliac joint fusion. The information provided outlines the regulatory submission, but does not detail a study that defines acceptance criteria in terms of performance metrics like sensitivity, specificity, accuracy, or effect size, as would be typical for an AI/ML or diagnostic device.
Instead, the document focuses on demonstrating substantial equivalence to existing legally marketed predicate devices through performance testing related to the device's physical and mechanical properties.
Here's an analysis based on the provided text, addressing your points where possible, and noting when information is not present:
1. Table of Acceptance Criteria and Reported Device Performance
The document does not provide acceptance criteria in the form of specific performance metrics (e.g., accuracy, sensitivity, specificity) for a clinical study or an AI/ML model. Instead, it states that "Performance testing, including biocompatibility, chemical characterization, mechanical static and dynamic shear testing, pull-out, cadaver and instrumentation testing was submitted to support the overall functionality and usability of the Tenon Medical Catamaran Sacroiliac Joint Fixation System."
Therefore, a table of acceptance criteria and reported device performance, as you've requested for a typical AI/ML or diagnostic device evaluation, cannot be extracted from this text. The "performance data" here refers to engineering and biocompatibility tests, not clinical efficacy or diagnostic performance.
2. Sample Size Used for the Test Set and Data Provenance
This information is not provided in the document. The document refers to "performance testing" which includes mechanical and cadaver testing, but does not specify sample sizes for these tests or characterize them as "test sets" in the context of clinical or AI/ML evaluations. There is no mention of country of origin or whether data was retrospective or prospective.
3. Number of Experts Used to Establish Ground Truth and Qualifications
This information is not provided. The document describes a medical device for surgical fixation, not a diagnostic or AI/ML system that would typically require expert-established ground truth on a test set.
4. Adjudication Method
This information is not provided. As above, adjudication methods are typical for expert review in clinical or AI/ML studies, which is not the focus of this device's performance data.
5. Multi-Reader Multi-Case (MRMC) Comparative Effectiveness Study
This information is not provided. The device is a surgical implant, not a diagnostic tool that human readers would use in conjunction with AI. Therefore, an MRMC study related to AI assistance for human readers is not applicable to this device and is not mentioned.
6. Standalone (Algorithm Only) Performance Study
This information is not provided. The device is a physical implant, not an algorithm. Therefore, a standalone algorithm performance study is not applicable and not mentioned.
7. Type of Ground Truth Used
The concept of "ground truth" as typically applied to diagnostic or AI/ML studies (e.g., expert consensus, pathology, outcome data) is not applicable or stated for the performance testing mentioned for this surgical implant. The "performance data" refers to engineering and biocompatibility tests, which would have their own established standards and reference methods for evaluation.
8. Sample Size for the Training Set
This information is not provided. This device is a physical implant, not an AI/ML model, so the concept of a "training set" is not relevant.
9. How Ground Truth for the Training Set Was Established
This information is not provided. As the device is not an AI/ML model, there is no training set or associated ground truth establishment.
Summary of what the document does provide regarding device evaluation:
The document is a 510(k) premarket notification letter for a Class II surgical implant (Catamaran Sacroiliac Joint Fixation System). The primary method of demonstrating its suitability for market is through substantial equivalence to existing predicate devices.
The "Performance Data" section indicates that the following types of testing were submitted:
- Biocompatibility: To ensure the implant is safe for interaction with biological tissues.
- Chemical Characterization: To understand the material composition.
- Mechanical Static and Dynamic Shear Testing: To evaluate the implant's strength and fatigue resistance under various loads.
- Pull-Out Testing: To assess the implant's resistance to being dislodged from bone.
- Cadaver Testing: Likely to evaluate surgical technique, implant placement, and initial stability in a simulated anatomical environment.
- Instrumentation Testing: To ensure the surgical tools function as intended.
These tests are standard for evaluating the safety and mechanical performance of orthopedic implants, demonstrating that the device is "capable of performing in accordance with its intended use" and "does not raise any new or different questions or concerns of safety or effectiveness as compared to commercially available predicate devices."
The document does not contain the details of a clinical study or an AI/ML model evaluation as implied by the structure of your request.