Found 2 results

510(k) Data Aggregation

    K Number
    K121560

    Validate with FDA (Live)

    Date Cleared
    2012-11-01

    (156 days)

    Product Code
    Regulation Number
    890.5150
    Reference & Predicate Devices
    Predicate For
    N/A
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    ThyssenKrupp Accessibility's Battery Operated Stair Lift LEVANT is intended to mechanically transport one mobility impaired person in a fold-down seat, up and down straight stairs, indoors and outdoors.

    Device Description

    Levant/ HomeGlide is a stair lift for transport of one person up and down straight stairs. The system consist of a drive unit, a foldable footrest and an aluminum rail that is fixed on the stairs. The system can be fixed on either sides of the stairs. It is available standard with a manual swivel for easy getting on and off the seat. It comes with a padded seat. A hinged rail, a heavy duty drive and a intermediate park position are available as options. The Comfort Option provides a premium positioned chair lift with extra options: straight or curved armrests, luxurious seat, fabric- vinyl- or leather upholstery, adjustable seat height, and a powered swivel. The Outdoor Option provides a stair lift for outdoor use in both cold and warm climates. The Outdoor option is created by adding a waterproof control, a waterproof cover, coated electronics, coated switches, waterproof charging contacts and a step up transformer.

    AI/ML Overview

    The provided text is a 510(k) summary for a medical device called the "LEVANT/HOMEGLIDE" Battery Operated Stair Lift for Straight Stairs. This document does not describe a study to prove the device meets acceptance criteria, but rather a comparison to a predicate device to establish substantial equivalence.

    Therefore, many of the requested categories related to acceptance criteria, study design, and performance metrics (like sample size, ground truth, expert involvement, and statistical analyses) are not applicable to the information provided. The document outlines a product comparison rather than a performance study with specific acceptance criteria that would typically be described for software or AI-driven medical devices.

    Here's how to address the questions based on the provided text, noting its limitations:

    1. A table of acceptance criteria and the reported device performance

    Since this is a 510(k) premarket notification focusing on substantial equivalence to a predicate device rather than a study with defined acceptance criteria and performance against those criteria, a direct "acceptance criteria" table as typically seen in performance studies is not present. Instead, the document compares the technical characteristics of the proposed device to a predicate device to demonstrate equivalence.

    Here’s a summary of the comparative characteristics, which implicitly serve as the basis for "performance" from an equivalence standpoint:

    CharacteristicPredicate Device (Bruno SRE-3000/SRE-2000) PerformanceProposed Device (ThyssenKrupp Accessibility Levant) Reported PerformanceDiscussion / Equivalence
    StandardsASME 18.1ASME 18.1Equivalent
    ApplicationStraight stairsStraight stairsEquivalent
    Rated Load (max)181 kg146 kgBoth exceed minimum standards; close enough for equivalence
    Passengers11Equivalent
    Power2 pieces 7AH 12 Battery2 pieces 7AH 12 BatteryEquivalent
    Charger24VDC/ 2AInd: 24VDC/ 1700 mA; Outd: 6 VACDifferent, but considered equivalent based on function
    DriveDirect drive worm gear motorDirect drive worm gear motorEquivalent
    Final Drive8dp gear rack with spur gear8dp gear rack with spur gearEquivalent
    BrakingDynamic, worm gear, el/mech brakeDynamic, worm gear, el/mech brakeEquivalent
    Call & SendIRIREquivalent
    Control3-position momentary rocker switch3-position momentary rocker switchEquivalent
    SupportsAnchored to stair threadAnchored to stair threadEquivalent
    Angle (max)22 to 45 degrees, specials up to 5228 to 53 degrees, heavy duty to 45Small difference, caused by design, considered equivalent
    Speed0.08 m/s0.12 m/sBoth below standards max; Proposed device is 50% faster but still acceptable
    Track length (max)6.1 meters max7.5 meters maxProposed device offers more length, but both meet implicit needs
    Construction RailAluminum extrude rail (Indoor), Exterior grade powder coated steel rail (Outdoor)Anodized aluminum extrude rail (Indoor/Outdoor)Different materials, but both fulfill safety requirements
    Safety devicesMultipleMultipleEquivalent
    FootrestFolding typeFolding typeEquivalent
    SeatFolding typeFolding typeEquivalent
    Indoor useYesYesEquivalent
    Outdoor useYesYesEquivalent
    Temp Range IndoorNot specified+5°C to +40°C (41°F to 104°F)Information provided for proposed device
    Temp Range Outdoor-5°C to +50°C (25°F to 125°F)-15°C to +60°C (5°F to 140°F)Differences discussed, but considered acceptable
    Construction ChairStainless steel (Outdoor)ABS Synthetic material (Outdoor)Different materials, but considered equivalent
    Electrical EnclosureIPx3IPx5Proposed device meets higher standard (EN 81-40 requirement), considered acceptable

    2. Sample sized used for the test set and the data provenance (e.g. country of origin of the data, retrospective or prospective)

    Not applicable. This document is a premarket notification for substantial equivalence, not a clinical or performance study involving a test set of data. The "comparison" is based on the technical specifications of the devices themselves, not on collected data from a test set.

    3. Number of experts used to establish the ground truth for the test set and the qualifications of those experts (e.g. radiologist with 10 years of experience)

    Not applicable. There is no test set or ground truth established by experts described in this document. The assessment is based on a technical review by the manufacturer and subsequently the FDA.

    4. Adjudication method (e.g. 2+1, 3+1, none) for the test set

    Not applicable. No test set or related adjudication method is described.

    5. If a multi reader multi case (MRMC) comparative effectiveness study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance

    Not applicable. This device is a mechanical stair lift, not an AI or imaging device that would involve human readers or comparative effectiveness studies of this nature.

    6. If a standalone (i.e. algorithm only without human-in-the-loop performance) was done

    Not applicable. This is a mechanical device, not an algorithm.

    7. The type of ground truth used (expert consensus, pathology, outcomes data, etc)

    Not applicable. There is no ground truth, as this document focuses on substantial equivalence based on technical specifications and adherence to standards (like ASME 18.1 and EN 81-40), rather than a diagnostic or analytical performance study.

    8. The sample size for the training set

    Not applicable. There is no training set mentioned or relevant for this type of mechanical device submission.

    9. How the ground truth for the training set was established

    Not applicable. There is no training set or ground truth described.

    Ask a Question

    Ask a specific question about this device

    K Number
    K121561

    Validate with FDA (Live)

    Device Name
    FLOW2, SWING
    Date Cleared
    2012-10-26

    (150 days)

    Product Code
    Regulation Number
    890.5150
    Reference & Predicate Devices
    Predicate For
    N/A
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    ThyssenKrupp Accessibility's Battery Operated Stair Lift FLOW2 is intended to mechanically transport one mobility impaired person in a fold-down seat, up and down curved stairs, indoors.

    Device Description

    Flow2 mono rail chairlift brings one person safely and comfortably up and down the stairs. In the meantime one saves ones energy for long outdoor walks, playing with the children or the daily tasks in house.

    Flow2 is capable to swivel during the ride up and down the stairs. This unique and patented feature makes that Flow2 chairlift fits most staircases, straight, around corners and even spiral. The angle of the staircase can vary from -70 degrees up to 70 degrees.

    The footrest is mounted directly to the chair. This provides a comfortable and ergonomic seating position of the user with less knee flexion.

    Flow2 is easy to use by a simple and light folding operation and the intuitive to use joystick control. Features such as anti squeeze, curved armrest and safety belt provide additional safety for the user and other inhabitants of the home.

    The design can be adapted to the home decor by the application of a variety of different seat fabrics and colors. Flow2 is the chairlift on the market which combines the best of 2 worlds; capable to fit on the smallest stairs while transporting the user in the most comfortable and safe way.

    AI/ML Overview

    Here's an analysis of the provided text regarding the acceptance criteria and study for the ThyssenKrupp Accessibility FLOW2 stair lift:

    This 510(k) summary does not contain a traditional performance study comparing the device to acceptance criteria with detailed metrics like sensitivity, specificity, accuracy, or confidence intervals. Instead, it relies on a substantial equivalence approach by comparing the FLOW2 to a predicate device (Bruno CRE-2110 Electra-Ride) and demonstrating compliance with relevant international standards.

    For medical devices, especially those that are electromechanical and not diagnostic in nature, "acceptance criteria" often refer to meeting established safety and performance standards, and demonstrating that the new device is as safe and effective as a legally marketed predicate.

    Here's a breakdown of the requested information based on the provided document:


    1. A table of acceptance criteria and the reported device performance

    For devices like a stair lift, acceptance criteria often relate to meeting specific safety standards, load capacities, speed limits, and other functional aspects. The "reported device performance" is essentially that the device meets these standards and is comparable to the predicate.

    Acceptance Criteria / StandardReported Device Performance (FLOW2)Predicate Device (Bruno CRE-2110 Electra-Ride)
    General Safety and Performance StandardsCompliant with ASME 18.1, IEC 60601-1-2:2007 (Certified by ETL and Lift Institute)Compliant with ASME 18.1, IEC 60601-1-2:2007
    Intended UseMechanically transport one mobility impaired person in a fold-down seat, up and down curved stairs, indoors.Mechanically transport one mobility impaired person in a fold-down seat, up and down stairs, indoors. (Implied for curved stairs as well given "Straight and Curved stairs" application)
    Rated Load (Maximum)275 lb (125 kg)400 lb (181 kg)
    Passengers11
    Power Supply2 pieces 7AH 12 Battery2 pieces 7AH 12 Battery
    Charger24VDC/ 2A24VDC/ 2A
    Drive MechanismPlanetary motor with worm gearDirect drive worm gear motor
    Final DriveLasered rack and pinion8dp gear rack with spur gear
    Braking SystemDynamic, worm gear, el/mech brakeDynamic, worm gear, el/mech brake
    Call & Send FunctionalityRFRF
    Support/MountingAnchored to stair threadAnchored to stair thread
    Maximum Stair Angle70 degrees50 degrees
    Speed0.15 m/s0.13 m/s
    Track Length (Maximum)34 m15 m
    Safety DevicesMultipleMultiple
    Footrest TypeFolding typeFolding type
    Seat TypeFolding typeFolding type
    Control Mechanism3 position switched RF unit3 position momentary rocker switch
    Construction MaterialBended round steel tube 80mmSteel welded shape
    Leveling MechanismPatented electronic leveling (multiple sensor controlled)Mechanically forced
    Swiveling MechanismPatented "en route" swivelingEnd of rail

    Note on Acceptance Criteria: For this type of device and submission, the primary "acceptance criteria" are the successful demonstration of substantial equivalence to a predicate device and compliance with recognized consensus standards (ASME 18.1, IEC 60601-1-2:2007). The "reported device performance" is essentially that the device meets these standards and its characteristics are within an acceptable range compared to the predicate, even where there are non-equivalent technological characteristics. The non-equivalent characteristics were discussed to show they do not raise new questions of safety or effectiveness.


    2. Sample sized used for the test set and the data provenance (e.g. country of origin of the data, retrospective or prospective)

    • Sample Size: Not applicable in the context of a clinical trial or performance study with a test set of data. The submission relies on engineering testing and comparison to standards and a predicate device.
    • Data Provenance: Not applicable for clinical data. The data provenance is from engineering and safety standard testing conducted by organizations like ETL and Lift Institute. The country of origin of the manufacturer is The Netherlands.

    3. Number of experts used to establish the ground truth for the test set and the qualifications of those experts (e.g. radiologist with 10 years of experience)

    • Not applicable. This is not a diagnostic device requiring expert interpretation for ground truth establishment. Third-party testing and certification bodies (ETL, Lift Institute) verified compliance with safety and performance standards. Their "expertise" for this type of device lies in their accreditation to test against these specific standards.

    4. Adjudication method (e.g. 2+1, 3+1, none) for the test set

    • Not applicable. There was no "test set" of clinical cases requiring adjudication. Compliance was determined by accredited testing laboratories against engineering standards.

    5. If a multi reader multi case (MRMC) comparative effectiveness study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance

    • No MRMC study was done. This device is a mechanical stair lift, not an AI-assisted diagnostic tool.

    6. If a standalone (i.e. algorithm only without human-in-the-loop performance) was done

    • Not applicable. This device is a mechanical device with human users, not an algorithm. Its operation involves human interaction (joystick control) for its intended function. The "standalone" performance would be its mechanical and electrical function independent of a specific user, verified by engineering tests.

    7. The type of ground truth used (expert consensus, pathology, outcomes data, etc.)

    • The "ground truth" for this submission is established by compliance with international consensus safety and performance standards (ASME 18.1, IEC 60601-1-2:2007) as verified by accredited testing bodies (ETL, Lift Institute). For mechanical devices, this often involves physical load testing, endurance testing, electrical safety testing, and functional assessments without human subjects.

    8. The sample size for the training set

    • Not applicable. There is no AI component or "training set" for this device.

    9. How the ground truth for the training set was established

    • Not applicable, as there is no training set for this device.