    K Number
    K252687

    Validate with FDA (Live)

    Date Cleared
    2025-11-21

    (87 days)

    Product Code
    Regulation Number
    890.3850
    Age Range
    All
    Reference & Predicate Devices
    N/A
    Predicate For
    N/A
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The manual wheelchair is to provide mobility to persons limited to a sitting position.

    Device Description

    Manual Wheelchair (HM305-Air1, HM305-Air2)

    AI/ML Overview

    N/A

    Ask a Question

    Ask a specific question about this device

    K Number
    K251638

    Validate with FDA (Live)

    Date Cleared
    2025-07-22

    (54 days)

    Product Code
    Regulation Number
    890.3800
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    N/A
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    "It is a motor driven, indoor and outdoor transportation vehicle with the intended use to provide mobility to a disabled or elderly person limited to a seated position."

    Device Description

    The product is a Mobility Scooter which provides transport for the disabled and the elderly and to be used both indoors and outdoors.

    This scooter is a battery powered four wheeled vehicle. It consists two Lead-acid batteries (in the battery box) with an off-board battery charger, frame, a seat, a back support, control panel (including the key switch, throttle control lever, horn button, speed adjustment dial, and the battery condition meter), two foldable handles, two rear drive wheels with motor/ e-magnetic brake components, two front wheels, anti-tip devices, an external battery charger, a control panel and a motor controller. For convenience of transportation and reduction of possible damage, the battery and the seat unit can be dismantled and separately packaged.

    The front wheels of the scooter are 8 inches and the rear wheels are 9 inches.
    The motor of the scooter is 24VDC,150W,4200RPM; the Lead-acid Battery is 12 V, 22 Ah, 18.7 Ah; the charger is 24V/2A.
    Max. loading cannot be over than 180kg.
    The maximum distance travelled with a fully charged battery is 17.5km and the maximum forward speed is 1.6m/s(5.8km/h).
    Braking time is less than 2 seconds, braking distance is ≤1.0 meters.

    AI/ML Overview

    This document is an FDA 510(k) Clearance Letter for a Mobility Scooter (MS160C). It is not an AI/ML medical device, and therefore does not contain the information typically associated with studies proving the performance of an AI/ML algorithm.

    The request asks for details like "sample size used for the test set," "number of experts used to establish ground truth," "adjudication method," "MRMC comparative effectiveness study," and "standalone performance," which are specific to the evaluation of AI/ML software. This information is irrelevant to a physical device like a mobility scooter.

    Therefore, I cannot provide the requested information as it is not present in the provided document. The document focuses on demonstrating substantial equivalence to a predicate device through non-clinical performance and safety testing against established standards (ISO, IEC).

    Here's why each point in your request cannot be answered based on the provided text:

    1. A table of acceptance criteria and the reported device performance: While the document lists performance characteristics in "Table 2 - Performance Comparison", these are not presented as "acceptance criteria" in the sense of accuracy/sensitivity/specificity targets for an AI algorithm. Instead, they are comparisons to a predicate device and compliance with established ISO standards. I can extract performance characteristics, but not "acceptance criteria" for an AI model.
    2. Sample sized used for the test set and the data provenance: Not applicable. This refers to data for an AI model. The mobility scooter underwent physical product testing.
    3. Number of experts used to establish the ground truth for the test set and the qualifications of those experts: Not applicable. Ground truth and expert review are for AI model validation.
    4. Adjudication method: Not applicable. Adjudication is for resolving discrepancies in AI model output or expert readings.
    5. If a multi reader multi case (MRMC) comparative effectiveness study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance: Not applicable. MRMC studies are for evaluating AI's impact on human performance in diagnostic tasks.
    6. If a standalone (i.e. algorithm only without human-in-the loop performance) was done: Not applicable. This device is a physical product, not an algorithm.
    7. The type of ground truth used (expert concensus, pathology, outcomes data, etc): Not applicable. "Ground truth" is a concept for AI model training and validation.
    8. The sample size for the training set: Not applicable. This refers to data for an AI model.
    9. How the ground truth for the training set was established: Not applicable. This refers to data for an AI model.

    However, I can extract information related to the device's performance testing based on the provided document:

    Study that proves the device meets requirements (Non-Clinical Testing):

    The study was a series of non-clinical tests conducted to verify that the proposed device (Mobility Scooter MS160C) met all design specifications and was substantially equivalent (SE) to the predicate device (Mobility Scooter Model: W3468, K220207).

    1. Table of Acceptance Criteria (as reported performance against standards, not AI-specific criteria) and the Reported Device Performance:

    The document describes compliance with various ISO and IEC standards as the basis for demonstrating safety and effectiveness. The "acceptance criteria" are implied by adherence to these standards, and the "reported performance" is demonstrated by the test results confirming this compliance.

    Key Performance Characteristics (from Table 2 - Performance Comparison):

    ItemAcceptance Criteria (implied by standards compliance)Reported Device Performance (Subject Device K251638)Predicate Device K220207Remark
    Max. loadingCompliance with ISO 7176-8 (Static, impact and fatigue strengths)396.83 lbs (180kg)352.7lbs (160kg)The difference will not raise any new safety and effectiveness concerns.
    Max Speed ForwardsCompliance with ISO 7176-6:2018 (Determination of maximum speed)1.6 m/s (5.78 km/h)1.8 m/s (6.4 km/h)The devices are evaluated according to standard ISO 7176-6:2018, so the different will not impact the safety and effectiveness.
    Minimum braking distanceCompliance with ISO 7176-3 (Determination of effectiveness of brakes)1.0m for the speed of 5.78 km/h 1s≤1.5m for the speed of 6.4km/h 1sThe subject device complies with the requirements of ISO 7176-3.
    Cruising RangeCompliance with ISO 7176-4 (Energy consumption for determination of theoretical distance range)17.5km20kmThe difference will not raise any new safety and effectiveness concerns.
    Slope Grade AbilityNo specific standard reference provided for this item in the table, but implied by overall ISO 7176 series compliance for stability.14 degree9 degreeLarger safe operational incline of subject brings more convenient for the use environment.
    Min. Turning radiusAddressed by ISO 7176-5 (Determination of overall dimensions, mass and manoeuvring space)1500mm1800mmThe little difference in the turning radius will not raise any new safety and effectiveness concerns.
    Obstacle climbingAddressed by ISO 7176-10 (Determination of obstacle-climbing ability)10mmNot Publicly AvailableThe difference will not raise any new safety and effectiveness concerns.
    Ground clearanceAddressed by ISO 7176-5 (Determination of overall dimensions, mass and manoeuvring space)63mm85mmThe device has been tested according to ISO7176 series standards and the test records support its safety and effectiveness.
    Static StabilityISO 7176-1:2014 compliantMeets standard requirementsMeets standard requirementsVerified.
    Dynamic StabilityISO 7176-2:2017 compliantMeets standard requirementsMeets standard requirementsVerified.
    Power and Control SystemsISO 7176-14:2008 compliantMeets standard requirementsMeets standard requirementsVerified.
    BiocompatibilityISO 10993-1, ISO 10993-5, ISO 10993-10, ISO 10993-23 compliantMeets standard requirementsMeets standard requirementsVerified.
    Electromagnetic CompatibilityIEC 60601-1-2:2020 & IEC TR 60601-4-2 compliantMeets standard requirementsMeets standard requirementsVerified.

    2. Sample size used for the test set and the data provenance:

    • Sample Size: The document does not specify the number of units tested. For physical device performance testing against standards, it's common to test a representative number of units, but this specific number is not provided in the summary.
    • Data Provenance: The tests are non-clinical, meaning they were conducted in a laboratory or controlled setting, presumably as part of the manufacturer's (Suzhou Master Machinery Manufacturing Co., Ltd., China) quality assurance and regulatory submission process. There is no mention of data from human subjects or specific geographical origin for "data provenance" in the sense of patient data.

    3. Number of experts used to establish the ground truth for the test set and the qualifications of those experts:

    • Not applicable as this is a physical device, not an AI/ML algorithm requiring expert ground truth for diagnostic or similar tasks. The "ground truth" for the device's performance is established by objective measurements against international standards.

    4. Adjudication method:

    • Not applicable for a physical medical device.

    5. If a multi reader multi case (MRMC) comparative effectiveness study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance:

    • No. This type of study is specific to AI/ML devices interacting with human interpreters.

    6. If a standalone (i.e. algorithm only without human-in-the-loop performance) was done:

    • Not applicable. This is a physical mobility scooter, not an algorithm.

    7. The type of ground truth used:

    • The "ground truth" for the mobility scooter's performance is established by objective measurements and conformance to international performance, safety, and quality standards (e.g., ISO 7176 series, IEC 60601-1-2, ISO 10993 series). This is not an "expert consensus" or "pathology" in the AI/ML context.

    8. The sample size for the training set:

    • Not applicable. This device is not an AI/ML algorithm that requires a training set.

    9. How the ground truth for the training set was established:

    • Not applicable.
    Ask a Question

    Ask a specific question about this device

    K Number
    K242982

    Validate with FDA (Live)

    Date Cleared
    2025-01-31

    (127 days)

    Product Code
    Regulation Number
    890.3800
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    It is a motor driven, indoor and outdoor transportation vehicle with the intended use to provide mobility to a disabled or elderly person limited to a seated position.

    Device Description

    The subject device, Model MS160A scooter is mainly battery-powered and driven by a DC motor, with the speed adjusted by a user-controlled panel.

    The motor is driven, and the speed is adjusted by a user-controlled panel and speed knob.

    The scooter consists of two folding armrests, a seat cushion, a folding frame, two front wheels, two rear drive wheels with a motor/electromagnetic brake assembly, a rechargeable lithium-ion battery, an off-board battery charger, a control panel, and a motor controller.

    The MS160A scooter is designed to provide mobility for people limited to those who walk unchanged or for the elderly.

    Folding design: Pull out the seat and backrest fixing pins, push the backrest forward, the seat and backrest fold into each other, release the handlebar locking knob, push the handlebar backward, the handlebar folds down, the whole scooter is folded.

    Control panel: Includes speed knob, battery gauge, power key switch, horn button, throttle control lever, headlight switch, charger port, fuse.

    Wheel and frame connection method: the motor is connected to the differential, the differential is connected to the frame, the wheels are mounted on both ends of the differential, the motor rotates with the differential, thus driving the scooter.

    Frame design:

    1. The frame of MS160A is aluminum alloy.
    2. The folding mechanism is operated in two ways:
      a. In the non-riding state, pull out the seat fixing pin, push the backrest forward, the seat and backrest can be folded.
      b. Loosen the handlebar locking knob, push the handlebar forward, the handlebar will fold down.

    The front wheels of the scooter are 7 inches and the rear wheels are 10 inches.

    The motor of the scooter is ST-62D24-120W; the lithium-ion battery is 25.55V 10.4AH; the charger is 24V/2A.

    Max. loading cannot be over than 125kg.

    The maximum distance travelled with a fully charged battery is 8.2km and the maximum forward speed is 1.8m/s.

    Braking time is about 2 seconds, braking distance is ≤1.5 meters.

    AI/ML Overview

    The provided document (K242982 510(k) Summary for the Mobility Scooter (MS160A)) is a premarket notification to the FDA for a Mobility Scooter. This type of device is a physical product and not typically associated with AI/ML software or studies involving ground truth establishment by experts, multi-reader multi-case (MRMC) comparative effectiveness studies, or standalone algorithm performance.

    Therefore, this document does not contain the information requested regarding acceptance criteria and study proving device meets acceptance criteria related to AI/ML product performance. The studies mentioned primarily confirm the device's compliance with physical safety and performance standards (e.g., ISO 7176 series for wheelchairs, biocompatibility).

    Here's why the requested information cannot be extracted from this document:

    • Device Type: A mobility scooter is a mechanical device, not imaging or diagnostic software that would rely on AI/ML algorithms to generate results requiring expert consensus or ground truth establishment.
    • Study Types: The "non-clinical testing" section details adherence to established ISO standards for physical characteristics like stability, braking, dimensions, and biocompatibility. There is explicitly "No clinical study implemented for the scooter."
    • Acceptance Criteria: The "acceptance criteria" for this device are its ability to meet the performance specifications outlined in the ISO standards, and to be "substantially equivalent" to a predicate device based on physical and functional comparisons. These are not acceptance criteria for AI model performance metrics like sensitivity, specificity, or AUC, which would be relevant for devices that interpret data or images.
    • Ground Truth, Experts, Sample Sizes (for AI/ML): These concepts are entirely absent because they are not applicable to the type of device being submitted.

    In summary, the provided document is for a physical medical device (mobility scooter) and does not involve AI/ML components or related performance studies that would utilize the concepts of ground truth, expert review, or statistical metrics like sensitivity/specificity for algorithm output.