Search Results
Found 24 results
510(k) Data Aggregation
(119 days)
The Digital Color Doppler Ultrasound System is a general-purpose ultrasonic imaging system intended for use by sufficiently trained healthcare professionals for ultrasound imaging, measurement, and analysis of the human body, which is intended to be used in a hospital or medical clinic.
The system is intended for use in the following clinical applications: Fetal, Abdominal, Pediatric, Small Organ (breast, testes, thyroid), Cephalic (neonatal and adult), Trans-rectal, Trans-vaginal, Peripheral Vascular, Cerebral Vascular, Musculo-skeletal (Conventional and Superficial), Cardiac (pediatric and adult), OB/Gyn and Urology.
Modes of operation include: B, M, PW Doppler, CW Doppler, Color Doppler, Color M Doppler, Power Doppler, Directional Power Doppler, Tissue Harmonic Imaging, Tissue Doppler Imaging, 3D/4D Imaging mode, Strain Elastography, Contrast imaging and Combined modes: B/M, B/PWD, B/THI, M/Color M, B/Color Doppler, B/Color Doppler/PWD, B/Power Doppler/PWD.
This X11 Exp/X11 Elite/X11 Pro/X11 Plus/X11 Super/X11 Senior/X11/E11/E11 Pro/E11 Plus/E11 Elite/X11T/X11U/X11R/X11i/X11s/E11T/E11i/E11s/XR1/XR2/XR3/ER1/ER2/ER3/X10 Exp/X10 Elite/X10 Pro/X10 Plus/X10 Super/X10 Senior/X10/X10T/X10U/X10R/X10i/X10s/E10/E10 Pro/E10 Plus/E10T/E10i/E10s/SU11A EXP/SU11A PRO/SU11A AD/SU11A CU/SU11B EXP/SU11B PRO/SU11B AD/SU11B CU/SU11C EXP/SU11C PRO/SU11C AD/SU11C CU Digital Color Doppler Ultrasound System (hereafter as "X11 Exp Series Digital Color Doppler Ultrasound System") is an integrated preprogrammed color ultrasound imaging system, capable of producing high detail resolution intended for clinical diagnostic imaging applications.
The basic principle is that system transmits ultrasonic energy into patient body and implements post processing of received echoes to generate onscreen display of anatomic structures and fluid flow within the body.
This system is a Track 3 device that employs a wide array of probes that include linear array, convex array phased array and etc.
This system consists of a console with touch screen and keyboard control panel, power supply module, color LCD monitor and optional probes.
This system is a portable, general purpose, software controlled, color diagnostic ultrasound system. Its basic function is to acquire ultrasound data and to display the image in B-Mode (including Tissue Harmonic Image), M-Mode, TDI, Color-Flow Doppler, Pulsed Wave Doppler, Continued Wave Doppler and Power Doppler, or the combination of these modes, Elastography, contrast, 3D/4D.
N/A
Ask a specific question about this device
(198 days)
The Digital Color Doppler Ultrasound System is a general-purpose ultrasonic imaging instrument intended for use by appropriately trained healthcare professionals in hospital for evaluation of Fetal, Abdominal, Pediatric, Small Organ (breast, testes, thyroid), Cephalic (neonatal and adult), Transrectal, Trans-vaginal, Peripheral Vascular, Cerebral Vasculoskeletal (Conventional and Superficial), Cardiac (pediatric and adult), Trans-esoph (Cardiac), Laparoscopic, OB/Gyn and Urology.
This SonoScape P60 Series Digital Color Doppler Ultrasound System is an integrated preprogrammed color ultrasound imaging system, capable of producing high detail resolution intended for clinical diagnostic imaging applications.
The basic principle is that system transmits ultrasonic energy into patient body and implements post processing of received echoes to generate onscreen display of anatomic structures and fluid flow within the body.
This system is a Track 3 device that employs a wide array of probes that include linear array, convex array phased array and etc.
This system consists of a mobile console with touch screen and keyboard control panel, power supply module, color LCD monitor and optional probes.
This system is a mobile, general purpose, software controlled, color diagnostic ultrasound system. Its basic function is to acquire ultrasound data and to display the image in B-Mode (including Tissue Harmonic Image), M-Mode, TDI, Color-Flow Doppler, Pulsed Wave Doppler, Continued Wave Doppler, Power Doppler, Direct Power Doppler, or the combination of these modes, Compound, 3D/4D, Elastography and Contrast.
Here's a breakdown of the acceptance criteria and the study details for the S-FetusAI feature of the Sonoscape Digital Color Doppler Ultrasound System (P60 Series), based on the provided text:
1. Table of Acceptance Criteria and Reported Device Performance
| Feature | Acceptance Criteria | Reported Device Performance |
|---|---|---|
| S-Fetus-Recognition | Accuracy: Not less than 85%. | 90.01% |
| S-Fetus-Measure | Accuracy: Not less than 80%. | 85% |
Clinical Performance:
| Evaluation Metric | Acceptance Criteria | Reported Device Performance |
|---|---|---|
| Identification Precision of the 14 Standard Sections (Primary Evaluation Indicator) | Non-inferiority design: The lower limit of the 95% CI for the difference of Identification Precision must be greater than -10% (S-FetusAI compared to manual recognition). | The recognition precision of the standard sections of S-FetusAI was not inferior to that of the manual scan. |
| Measurement Error of Growth Parameters (Secondary Evaluation Indicator) | - Relative errors of measurement for 11 Growth Parameters.- Precision of Sp (spinal cord cone end positioning). | S-FetusAI has a good consistency with the manual measurement.The Sp (spinal cone end positioning) precision was basically equal between the trial group and control group. |
2. Sample Size Used for the Test Set and Data Provenance
- S-Fetus-Recognition Test Set:
- More than 200 images for each of the 14 standard sections.
- Total: 3717 images.
- S-Fetus-Measure Test Set:
- More than 250 images for each of the 9 standard sections.
- Total: 2929 images.
- Data Provenance: A mix of retrospective and prospective data collection in clinical practice. The test sets were collected at three hospitals in China.
3. Number of Experts Used to Establish the Ground Truth for the Test Set and Their Qualifications
- Initial Ground Truth Drawing: Five OB/GYN experts with more than 3 years' experience.
- Cross-checking: Two experts with more than 20 years' experience.
- Re-checking: Four experts with more than 30 years' experience.
- Clinical Performance Study (Adjudication of results): Two Readers from an independent evaluation group, consisting of qualified professionals (senior experts who had been involved in prenatal ultrasound examination).
4. Adjudication Method for the Test Set
The ground truth was established through a multi-level expert consensus process:
- Initial Drawing: 5 OB/GYN experts.
- Cross-checking: 2 senior experts.
- Re-checking: 4 very senior experts.
This indicates a robust, multi-stage consensus-based adjudication, effectively a form of "expert consensus with multiple layers of review."
For the clinical performance testing, a separate "independent evaluation group" with 2 senior experts evaluated the section recognition results and precision of Sp from both the trial (AI-assisted) and contrast (manual) groups.
5. If a Multi-Reader Multi-Case (MRMC) Comparative Effectiveness Study Was Done, If So, What Was the Effect Size of How Much Human Readers Improve with AI vs Without AI Assistance
- A clinical performance testing was conducted, which involved comparing the S-FetusAI function (Trial group) with manual recognition and measurement by investigators (Contrast group). This can be considered a comparative effectiveness study.
- Research Group Composition (Contrast Group): Investigators (physicians with more than 3 years of specialized training in obstetric ultrasound examination; total 7 investigators) performing manual recognition and measurement.
- Effect Size: The study focused on demonstrating non-inferiority rather than a specific improvement percentage for human readers with AI assistance. The conclusion states that "the recognition precision of the standard sections of S-FetusAI was not inferior to that of the manual scan." This implies that the AI-assisted system performs at least as well as, or comparably to, manual recognition. It does not explicitly quantify how much human readers improve when using AI, but rather that the AI's standalone performance (for recognition) and consistency/precision (for measurement) are comparable to manual methods.
6. If a Standalone (i.e., algorithm only without human-in-the-loop performance) Was Done
Yes, a standalone performance testing was done for the S-FetusAI feature for both S-Fetus-Recognition and S-Fetus-Measure. The results (90.01% accuracy for recognition and 85% accuracy for measurement) are reported as entirely algorithmic performance against established ground truth.
7. The Type of Ground Truth Used
The ground truth used was expert consensus. It was established by multiple OB/GYN experts with varying levels of experience, going through a process of initial drawing, cross-checking, and re-checking. Any images not meeting inclusion/exclusion criteria were excluded from the ground truth set.
8. The Sample Size for the Training Set
The document explicitly states: "The test set used to test the standalone performance of S-FetusAI are independent of the training data set and tuning data set". However, the sample size for the training set is not provided in the given text.
9. How the Ground Truth for the Training Set Was Established
While the document implies that training and tuning datasets were used, the specific method for establishing their ground truth is not mentioned in the provided text. It only details the ground truth establishment for the test set.
Ask a specific question about this device
(261 days)
The ultrasonic gastrovideoscope (hereinafter called endoscope) is intended to provide endoscopic images for the examination and diagnosis of the upper gastrointestinal tract and to perform the ultrasound examination and diagnosis of the upper gastrointestinal sub-mucosa and the surrounding organs.
The endoscope should be used in the medical institution. The operator of the endoscope should be a physician or a medical staff supervised by a physician, both of whom have received sufficient training in clinical endoscopy technology.
The subject device, Ultrasonic Gastrovideoscope, is consisting of insertion, control section and connector section. The insertion is consisting of a distal end, a bending section and an insertion tube. This Ultrasonic Gastrovideoscope is intended to use in conjunction with Endoscopic Image Processor (HD-550Exp, HD-550, HD-550Pro, HD-550S, HD-510 and HD-500Plus), light source (VLS-55Q, VLS-55T, VLS-51D and VLS-51T), ultrasound system (P60 Exp, P60, P60 Pro, P60 CV, P60S and P60 VO) and monitor to provide endoscopic images for the examination and diagnosis of the upper gastrointestinal tract and to perform the ultrasound examination and diagnosis of the upper gastrointestinal sub-mucosa and the surrounding organs.
The Ultrasonic Gastrovideoscope is a reusable device. The Ultrasonic Gastrovideoscope has only one model EG-UR5.
The prospective clinical value of the enhanced imaging modes (EWL, SFI, and VIST) has not been demonstrated, and no clinical claims are made.
The provided text describes the acceptance criteria and the study conducted for the Sonoscape Medical Corp. Ultrasonic Gastrovideoscope (EG-UR5).
Here's the information broken down as requested:
1. Table of Acceptance Criteria and Reported Device Performance
The acceptance criteria are generally established by testing against recognized standards and comparing performance to a predicate device. The document repeatedly states that the device's performance is "similar" to or "meets the requirements" of the predicate device and relevant standards.
| Acceptance Criteria Category | Specific Criteria (Implicit or Explicit from Standard/Predicate Comparison) | Reported Device Performance (Summary) |
|---|---|---|
| Biocompatibility | No cytotoxicity, no sensitization, no irritation (comply with ISO 10993 series) | Met: "No Cytotoxicity, No Sensitization, No Irritation." |
| Optical Performance | Color reproduction, depth of field, intensity uniformity, optical magnification and distortion, resolution, dynamic range similar to predicate. | Met: "same or similar optical performance" compared to predicate. |
| Ultrasonic Performance | Similar performance indexes of ultrasonic quantization imaging compared to predicate. | Met: Performance indexes of ultrasonic quantization imaging are "similar" to predicate; no clinically significant difference. |
| Irrigation Performance | Air/Water-feeding and Suction Performance similar to predicate. | Met: "similar irrigation performance" compared to predicate. |
| Backflow Prevention | Effectively prevent contaminated liquid backflow to the proximal irrigation system (per FDA guidance). | Met: "effective and reliable" prevention of backflow. |
| Performance Stability | Mechanical fatigue from long-period use does not decrease endoscope performance; appearance, handle strength, image function, sealing, and bending angle meet clinical requirements after simulated fatigue. | Met: Components mechanically fatigue will "not lead to the decrease of endoscope performance...still meet the clinical requirements." |
| Imaging Performance Attenuation | Degradations in imaging performance (noisy point, color reducibility, resolution, bad point) are detected before leading to misdiagnosis over the device's lifetime. | Met: Image performance is "still in a better condition" over lifetime; degradations are "very little" and "will not affect the normal use." |
| Dimensions | Performance meets ISO 8600 requirements despite similar but not identical dimensions to predicate. | Met: ISO 8600 testing conducted; performance "meets the requirements." |
| Acoustic Frequency | Clinical safety and effectiveness not affected by similar acoustic frequency range compared to predicate. | Met: Acoustic performance comparison showed "basically the same" results; differences within measurement error and "will not affect the safety and effectiveness." |
| Depth of Field | Clinical safety and effectiveness not affected by similar depth of field compared to predicate. | Met: No statistical difference in performance compared to predicate; "will not affect the safety and effectiveness." |
| Bend Angulation | Performance meets ISO 8600 requirements and provides sufficient operating space despite being different from predicate. | Met: ISO 8600 testing conducted; performance "meets the requirements." Angulation is greater, offering "more operating space." |
| Electrical Safety | Comply with IEC 60601-1. | Met: "Comply with IEC 60601-1." |
| EMC | Comply with IEC 60601-1-2. | Met: "Comply with IEC 60601-1-2." |
| Particular Requirements | Comply with IEC 60601-2-18 and IEC 60601-2-37. | Met: "Comply with IEC 60601-2-18, Comply with IEC 60601-2-37." |
2. Sample Size Used for the Test Set and Data Provenance
The document does not explicitly state the sample size for test sets (e.g., number of devices tested for each non-clinical test). The studies appear to be non-clinical bench testing rather than clinical studies on human subjects.
- Data Provenance: The tests were conducted by the manufacturer, Sonoscape Medical Corp., in China, as indicated by their address. The data is retrospective in the sense that it was collected as part of the device development and verification process before submission for FDA clearance.
3. Number of Experts Used to Establish Ground Truth for the Test Set and Their Qualifications
- Not Applicable. As this was a non-clinical submission, the "test set" refers to physical device testing against standards and predicate devices, not clinical data requiring expert human interpretation for ground truth.
4. Adjudication Method for the Test Set
- None. Since there was no clinical test set requiring human interpretation, no adjudication method was used. The evaluation involved technical measurements and comparisons to established standards and the predicate device's specifications.
5. If a Multi-Reader Multi-Case (MRMC) Comparative Effectiveness Study Was Done
- No. The document explicitly states: "No clinical study is included in this submission." Therefore, no MRMC study was performed.
6. If a Standalone (i.e. algorithm only, without human-in-the-loop performance) Was Done
- Not Applicable. The device is an endoscope, a hardware medical device that directly captures images and performs ultrasound. It is not an AI algorithm or software-only device, so the concept of "standalone algorithm performance" does not apply in this context. Its performance is intrinsically tied to human operation and interpretation.
7. The Type of Ground Truth Used
The ground truth for the non-clinical tests was established by:
- Technical Specifications and Performance of the Predicate Device (K130206): The subject device's performance was compared directly to that of the PENTAX EG-3670URK Ultrasound Video Gastroscope.
- International Standards: Compliance with standards such as ISO 10993 (biocompatibility), IEC 60601-1 (electrical safety), IEC 60601-1-2 (EMC), IEC 60601-2-18, IEC 60601-2-37 (particular requirements), and ISO 8600 (endoscope performance).
- FDA Guidance Documents: For example, "Mitigating the risk of Cross-Contamination from valves and Accessories Used for irrigation through Flexible Gastrointestinal Endoscopes" for backflow prevention.
8. The Sample Size for the Training Set
- Not Applicable. This device is a hardware endoscope, not an AI or machine learning system. Therefore, there is no "training set" in the context of algorithm development.
9. How the Ground Truth for the Training Set Was Established
- Not Applicable. See point 8.
Ask a specific question about this device
(168 days)
The S90 Exp Series Digital Color Doppler Ultrasound System (S90 Exp, S80 Exp, S80 Exp, S80 Plus, S80 Elite, S80 Senior, S80 Super, S70i, S100 Exp, P90i, P80, P80 Exp, P80 Plus, P80 Elite, P80 Senior, P80 Super, P70i, I80-Endo, I80-Surg, 175-Endo, 170-Endo) is a general-purpose ultrasonic imaging instrument intended for use by a qualified physician or sonographer with sufficient clinical ultrasound training for ultrasound imaging, measurement, display and analysis of the human body and fluid, which is intended to be used in a hospital or medical clinic. The system is applicable for people who need clinical ultrasound examination.
The system is intended for use in the following clinical applications: Fetal, Abdominal, Pediatric, Small Organ (breast, testes, thyroid), Cephalic (neonatal and adult), Trans-vaginal, Peripheral Vascular, Cerebral Vascular, Musculo-skeletal (Conventional and Superficial), Cardiac (pediatric and adult), Trans-esophageal (Cardiac), Laparoscopic, OB/Gyn and Urology.
Modes of operation include: B, M, PW Doppler, CW Doppler, Color M Doppler, Power Doppler, Power Doppler, Directional Power Doppler, Tissue Harmonic Imaging, Tissue Doppler Imaging, 3D/4D Imaging mode, Strain Elastography, Shear Wave Elastography, Contrast and Combined modes: B/M, B/PWD, B/THI, M/Color M, B/Color Doppler, B/Color Doppler/PWD, B/Power Doppler/PWD.
This SonoScape S90 Exp Series Digital Color Doppler Ultrasound System is an integrated preprogrammed color ultrasound imaging system, capable of producing high detail resolution intended for clinical diagnostic imaging applications.
The basic principle is that system transmits ultrasonic energy into patient body and implements post processing of received echoes to generate onscreen display of anatomic structures and fluid flow within the body.
This system is a Track 3 device that employs a wide array of probes that include linear array, convex array and phased array.
This system consists of a mobile console with touch screen and keyboard control panel, power supply module, color LCD monitor and optional probes.
This system is a mobile, general purpose, software controlled, color diagnostic ultrasound system. Its basic function is to acquire ultrasound data and to display the image in B-Mode (including Tissue Harmonic Image), M-Mode, TDI, Color-Flow Doppler, Pulsed Wave Doppler, Continued Wave Doppler, Power Doppler and Directional Power Doppler Imaging, or the combination of these modes, Contrast Imaging, Strain Elastography, Shear Wave Elastography (S-SWE, P-SWE), SonoFusion, 3D/4D.
The provided text describes the Sonoscape Medical Corp.'s S90 Exp Series Digital Color Doppler Ultrasound System and its substantial equivalence to predicate devices, but does not contain information about specific acceptance criteria related to a performance study for the device's clinical or algorithmic performance, nor does it detail a study that proves the device meets such criteria.
The document primarily focuses on:
- Indications for Use: What the device is intended for (various clinical applications and modes of operation).
- Comparison to Predicate Devices: Explaining how the S90 Exp Series is similar to previously cleared devices in terms of intended use, regulations, safety standards, acoustic output, probes, biopsy brackets, and technical characteristics.
- Non-Clinical Tests: Listing compliance with electrical safety, EMC, acoustic, and software verification standards.
Therefore, I cannot provide the requested information. The text explicitly states:
"No clinical testing was required."
This indicates that, for the purpose of this 510(k) submission, a clinical study demonstrating the device's performance against specific clinical acceptance criteria was not performed or submitted. The substantial equivalence argument is based on the device's similarity to predicate devices and compliance with non-clinical technical standards.
Ask a specific question about this device
(155 days)
The P12 Elite Series Digital Color Doppler Utrasound System (P12 Exp, P12 Elite, P12 Pro, R12, P12N, P11 Exp, P11 Elite, P11 Pro, R11, P11N, P10 Eirte, P10N, R10, P9 Eirte, M11,R9) is a general-purpose ultrasonic imaging instrument intended for use by a qualified and trained physician for ultrasound imaging, measurement, display and analysis of the human body and fluid, which is intended to be used in a hospital or medical clinic. The system is applicable for people who need clinical ultrasound examination. Age, weight, health condition and race are unlimited. The system is intended for use in the following clinical applications: Fetal, Abdominal, Pediatric, Small Organ (breast, testes, thyroid), Cephalic (neonatal and adult), Trans-rectal, Trans-vaginal, Peripheral Vascular, Cerebral Vascular, Musculo-skeletal (Conventional and Superficial), Cardiac (pediatric and adult), Trans-esoph (Cardiac), Laparoscopic, OB/ Gyn and Urology.
This SonoScape P12 Elite Series Digital Color Doppler Ultrasound System is an integrated preprogrammed color ultrasound imaging system, capable of producing high detail resolution intended for clinical diagnostic imaging applications.
The basic principle is that system transmits ultrasonic energy into patient body and implements post processing of received echoes to generate onscreen display of anatomic structures and fluid flow within the body.
This system is a Track 3 device that employs a wide array of probes that include linear array, convex array and phased array.
This system consists of a mobile console with touch screen and keyboard control panel, power supply module, color LCD monitor and optional probes.
This system is a mobile, general purpose, software controlled, color diagnostic ultrasound system. Its basic function is to acquire ultrasound data and to display the image in B-Mode (including Tissue Harmonic Image), M-Mode, TDI, Color-Flow Doppler, Pulsed Wave Doppler, Continued Wave Doppler, Power Doppler and Directional Power Doppler Imaging, or the combination of these modes, Contrast Imaging, Elastography, 3D/4D.
The provided text details the P12 Elite Series Digital Color Doppler Ultrasound System and its substantial equivalence to predicate devices, but it does not include a study that proves the device meets specific performance acceptance criteria related to efficacy beyond general safety and electrical standards. The document states "No clinical testing was required" (Section 8).
Therefore, most of the requested information regarding acceptance criteria, device performance, sample sizes, ground truth establishment, expert involvement, and comparative/standalone effectiveness studies is not available in the provided text.
However, the document does list non-clinical performance test results:
1. Table of Acceptance Criteria and Reported Device Performance
| Performance Test | Acceptance Criteria (Standard) | Reported Device Performance |
|---|---|---|
| Electrical safety testing | IEC 60601-1:2005+A1:2012 | Passed |
| EMC testing | IEC 60601-1-2:2014 | Passed |
| Acoustic testing | IEC 60601-2-37:2007+A1:2015; AIUM/NEMA UD 2:2004 (R2009) | Passed |
| Software Verification and Validation | IEC 62304:2006 +A1:2015 | Passed |
2. Sample size used for the test set and the data provenance:
- Sample Size: Not applicable/not specified for performance criteria beyond standards compliance. The document explicitly states "No clinical testing was required." The "test set" in this context refers to the device and its components undergoing engineering and safety evaluations rather than a clinical dataset.
- Data Provenance: Not specified, but likely internal laboratory testing by Sonoscape Medical Corp. (manufacturer's non-clinical testing).
3. Number of experts used to establish the ground truth for the test set and the qualifications of those experts:
- Not applicable/not specified, as no clinical ground truth was established from expert consensus for device performance. The "ground truth" for the non-clinical tests was the compliance with established engineering and safety standards.
4. Adjudication method (e.g., 2+1, 3+1, none) for the test set:
- Not applicable/not specified, as individual case-level adjudication by experts was not performed for these non-clinical tests. Compliance was assessed against defined technical standards.
5. If a multi-reader multi-case (MRMC) comparative effectiveness study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance:
- No. The document explicitly states "No clinical testing was required." The device is a general-purpose ultrasound system, not an AI-assisted diagnostic tool discussed in the context of improving human reader performance.
6. If a standalone (i.e. algorithm only without human-in-the loop performance) was done:
- Not applicable. The device is a diagnostic ultrasound system, not an algorithm being tested in a standalone capacity without a human operator. Its performance is assessed through its ability to provide images and measurements for human interpretation.
7. The type of ground truth used (expert consensus, pathology, outcomes data, etc.):
- For the non-clinical tests described, the "ground truth" was compliance with established international and national engineering, electrical, electromagnetic, acoustic output, software, and biocompatibility standards (e.g., IEC 60601 series, ISO 10993, AIUM/NEMA UD 2).
8. The sample size for the training set:
- Not applicable. This document describes the regulatory clearance of a medical device (ultrasound system), not the development or validation of a machine learning model that requires a training set.
9. How the ground truth for the training set was established:
- Not applicable. As above, this document does not concern a machine learning model with a training set.
Ask a specific question about this device
(147 days)
The P20 Elite Series Digital Color Doppler Ultrasound System (P25 Exp, P20 Exp, P20 Elite, P22 Elite, P22 Exp, P15 Exp and P15 Elite) is a general-purpose ultrasonic imaging instrument intended for use by a qualified and trained physician for ultrasound imaging, measurement, display and analysis of the human body and fluid, which is intended to be used in a hospital clinic. The system is applicable for people who need clinical ultrasound examination. Age, weight, health condition and race are unlimited.
The system is intended for use in the following clinical applications: Fetal, Abdominal, Pediatric, Small Organ (breast, testes, thyroid), Cephalic (neonatal and adult), Trans-rectal, Trans-vaginal, Peripheral Vascular, Cerebral Vascular, Musculo-skeletal (Conventional and Superficial), Cardiac (pediatric and adult), Trans-esoph (Cardiac), Laparoscopic, OB/ Gyn and Urology.
Modes of operation include: B, M, PW Doppler, CW Doppler, Color M Doppler, Power Doppler, Directional Power Doppler, Tissue Harmonic Imaging, Tissue Doppler Imaging mode, Elastography, Contrast and Combined modes: B/M, B/PWD, B/THI, M/Color Doppler, B/Color Doppler/PWD, B/Power Doppler/PWD.
This SonoScape P20 Elite Series Digital Color Doppler Ultrasound System is an integrated preprogrammed color ultrasound imaging system, capable of producing high detail resolution intended for clinical diagnostic imaging applications.
The basic principle is that system transmits ultrasonic energy into patient body and implements post processing of received echoes to generate onscreen display of anatomic structures and fluid flow within the body.
This system is a Track 3 device that employs a wide array of probes that include linear array, convex array and phased array.
This system consists of a mobile console with touch screen and keyboard control panel, power supply module, color LCD monitor and optional probes.
This system is a mobile, general purpose, software controlled, color diagnostic ultrasound system. Its basic function is to acquire ultrasound data and to display the image in B-Mode (including Tissue Harmonic Image), M-Mode, TDI, Color-Flow Doppler, Pulsed Wave Doppler, Continued Wave Doppler, Power Doppler and Directional Power Doppler Imaging, or the combination of these modes, Contrast Imaging, Elastography, 3D/4D.
The provided FDA 510(k) summary (K221140) describes the Sonoscape P20 Elite Series Digital Color Doppler Ultrasound System. This document focuses on demonstrating substantial equivalence to a predicate device rather than presenting a study for software performance and acceptance criteria for an AI/ML powered device.
Therefore, the information required to answer your request (acceptance criteria, study details, sample sizes, expert qualifications, adjudication, MRMC studies, standalone performance, ground truth details, and training set information) is not available in the provided text.
The document discusses general performance tests related to electrical safety, EMC, acoustic testing, and software verification/validation, but these are for the overall ultrasound system's hardware and embedded software, not for an AI/ML algorithm within the system.
The "P20 Elite Series" system includes some "newly added features in Function" such as "contrast imaging, Color 3D, S-Live/S-Live Silhouette/S-Live Contour, S-Depth, STIC, 3D/4D HyCoSy, SPI, Micro F, SR Flow, Auto Face, VCI and etc." and "new features (Measurement Items), including AVC Follicle, Auto OB, Auto NT, Auto EF, Auto bladder, Auto IMT and etc."
For these new functions, the summary states:
- They are "the same as or similar with the imaging functions of the reference device S60 Elite Series/S70 Series Digital Color Doppler Ultrasound System (K201059)" for imaging functions.
- They are "the same as or equivalent with the measurement functions of the reference S60 Elite Series/S70 Series Digital Color Doppler Ultrasound System (K201059)" for measurement items.
- "The differences in function and measurement items will not raise new risk and different questions of safety and effectiveness."
- "The end user can edit, accept, or reject the measurements and can modify the measurement results at any point. The final output and its accuracy is controlled by the end user."
This indicates that these functions are either manual or assisted measurement tools where the final decision rests with the user, and their performance is deemed similar to existing cleared devices, not necessarily validated through specific AI/ML performance studies with acceptance criteria as you've requested.
Conclusion: The provided text does not contain the detailed information regarding acceptance criteria and performance studies for an AI/ML powered device as outlined in your request. The submission focuses on demonstrating substantial equivalence of a general-purpose ultrasound system to a predicate device based on technical characteristics and safety standards.
Ask a specific question about this device
(62 days)
The HD-550 video endoscope system, which includes a video colonoscope, image processor, light source, monitor, accessories and other peripheral devices, is intended for endoscopic examination, diagnosis and treatment of the upper and lower gastrointestinal tract.
The EG-550 Series Video Gastroscope has been designed to be used with the image processor. Iight source, monitor and other peripheral devices for endoscopic observation, diagnosis and treatment of the upper digestive tract (including the esophagus, stomach and duodenum).
The EC-550 Series Video Colonoscope has been designed to be used with the image processor, light source, monitor and other peripheral devices for endoscopic observation, diagnosis and treatment of the lower digestive tract (including the anus, rectum, colon and ileocecal segment).
The HD-550 Series Image Processor has been designed to be used with the endoscope, light source, monitor and other peripheral devices for endoscopic observation, diagnosis, treatment, and video recording.
The VLS-55 Series Light Source has been designed to be used with the endoscope, image processor and other peripheral devices for endoscopic observation, diagnosis and treatment.
The proposed device, HD-550 Video Endoscope System, which includes a video gastroscope /video colonoscope, image processor, light source, monitor, accessories and other peripheral devices.
HD-550 Video Endoscope System can be offered in several configurations with the options of different models of primary components.
The EG-550 Series Video Gastroscope/ EC-550 Series Video Colonoscope is the hand-held, direct-viewing flexible endoscope used for endoscopy and endoscopic surgery within the upper and lower gastrointestinal tract.
The HD-550 Series Image Processor is a video processing system which is designed to be used with endoscopes, light source, monitor of the proposed system. Apart from the image processing functions, it also provides power supply for the endoscopes.
The VLS-55 Series Light Source provides illumination for endoscopic diagnosis, treatment and video observation.
The SonoScape Medical Corp. HD-550 Video Endoscope System (K222020) is found to be substantially equivalent to its predicate device (K211882) based on non-clinical performance data. No clinical study was performed.
Here's a breakdown of the requested information:
1. Table of Acceptance Criteria and Reported Device Performance
Since this is a substantial equivalence determination based on an identical predicate device, the "acceptance criteria" are effectively the specifications and performance of the predicate device, and the "reported device performance" is the claim that the proposed device is identical to the predicate device in these aspects.
| Feature / Performance Metric | Acceptance Criteria (Predicate Device K211882) | Reported Device Performance (Proposed Device K222020) |
|---|---|---|
| General | ||
| Product Code | NWB, FDF and FDS | NWB, FDF and FDS |
| Regulation Number | 21 CFR 876.1500 | 21 CFR 876.1500 |
| Class | II | II |
| Indications for Use | Identical for all components | Identical for all components |
| Configuration (primary components) | Light Source, Image Processor, Video Gastroscope, Video Colonoscope, Accessories and peripheral devices | Identical |
| HD-550 Series Image Processor | (Specifications found in Table 2) | Identical |
| Power supply | 100-240V AC, 50/60Hz | 100-240V AC, 50/60Hz |
| Over-current protection | Fuse type | Fuse type |
| Size | 370(W)×124(H)×500(D)mm (varies by model) | Identical (varies by model) |
| Weight | 11.1 Kg | 11.1 Kg |
| Compatible endoscope | Videoscope | Videoscope |
| Video signal output | DVI, VGA, SDI, CVBS, S-Video | Identical |
| Auto white balance | Automatically adjusted | Automatically adjusted |
| Color tone adjustment | Red: ±15 steps, Blue: ±15 steps, chroma: ±15 steps | Identical |
| Automatic gain control | Provided | Provided |
| Image enhancement | Edge, Structure, Contrast, Color enhancement | Identical |
| IRIS mode selection | Peak/AVE/Auto photometry mode | Peak/AVE/Auto photometry mode |
| Zoom | 1.0 - 4.0 | 1.0 - 4.0 |
| Imaging modes | White light (WL), Enhanced white light (EWL), Spectral focused (SFI), Intelligent staining technology (VIST) | Identical |
| Foot switch connector | Provided | Provided |
| Record to memory card | Provided | Provided |
| EC-550 Series Video Colonoscope | (Specifications found in Table 3 and 4 for Gastroscopes) | Identical for all models (EC-550, EC-550T, EC-550L, EC-550L/T) |
| Field of view | 140° | 140° |
| Depth of focus | 3-100mm | 3-100mm |
| Front view | 0° | 0° |
| Sensor type | color CMOS | color CMOS |
| Distal end outer diameter | 12mm - 12.9mm (varies by model) | Identical (varies by model) |
| Insert section outer diameter | 12.5mm - 12.9mm (varies by model) | Identical (varies by model) |
| Bend angle | UP:180°, DOWN:180°, RIGHT:160°, LEFT:160° | Identical |
| Insertion section length | 1350mm - 1700mm (varies by model) | Identical (varies by model) |
| Total length | 1700mm - 2050mm (varies by model) | Identical (varies by model) |
| Biopsy channel inner diameter | ≥ 3.8mm - ≥ 4.2mm (varies by model) | Identical (varies by model) |
| EG-550 Series Video Gastroscope | (Specifications found in Table 4) | Identical for all models (EG-550, EG-550L) |
| Field of view | 140° | 140° |
| Depth of focus | 3-100mm | 3-100mm |
| Front view | 0° | 0° |
| Sensor type | color CMOS | color CMOS |
| Distal end outer diameter | 9.3mm - 9.8mm (varies by model) | Identical (varies by model) |
| Insertion section outer diameter | 9.3mm - 9.8mm (varies by model) | Identical (varies by model) |
| Bend angle | UP:210°, DOWN:90°, RIGHT:100°, LEFT:100° | Identical |
| Insertion section length | 1050mm | 1050mm |
| Total length | 1400mm | 1400mm |
| Biopsy channel inner diameter | 2.8mm - 3.2mm (varies by model) | Identical (varies by model) |
| VLS-55 Series Light Source | (Specifications found in Table 5) | Identical |
| Power supply | AC 100-240V, 50Hz/60Hz | AC 100-240V, 50Hz/60Hz |
| Over-current protection | Fuse type | Fuse type |
| Input current | 300VA | 300VA |
| Examination lamp | 50W LED | 50W LED |
| Average lamp life | 50000 hours | 50000 hours |
| Emergency lamp | 14W LED | 14W LED |
| Average emergency lamp life | 50000 hours | 50000 hours |
| Brightness control | Automatic and manual | Automatic and manual |
| Automatic exposure | 19 steps | 19 steps |
| System connector | Provided | Provided |
| Foot switch connector | Provided | Provided |
| CV connector | Provided | Provided |
| Safety and Biocompatibility | (Standards found in Table 6) | Identical |
| Electrical Safety | Comply with IEC 60601-1 | Comply with IEC 60601-1 |
| EMC | Comply with IEC 60601-1-2 | Comply with IEC 60601-1-2 |
| Particular requirements | Comply with IEC 60601-2-18 | Comply with IEC 60601-2-18 |
| Product Performance | Comply with ISO 8600-1 and ISO 8600-7 | Comply with ISO 8600-1 and ISO 8600-7 |
| Patient-contact component material | PU, fluoroelastomer (Insertion section); PEEK, Sapphire crystal SUS 304 (Distal end); Epoxy resin (Adhesive) | Identical |
| Biocompatibility | Cytotoxicity, Sensitization, Irritation (ISO 10993 standards) | Identical |
2. Sample size used for the test set and the data provenance (e.g. country of origin of the data, retrospective or prospective)
- Sample size for the test set: Not applicable. The submission states, "No clinical study is included in this submission." The evaluation relies on the equivalence of the proposed device to the predicate device, which itself would have had its performance demonstrated through testing. The current submission focuses on non-clinical tests to demonstrate that the proposed device is identical to the predicate device in all relevant aspects, except for a reprocessing change.
- Data provenance: Not explicitly stated for the non-clinical tests. However, the manufacturer is Sonoscape Medical Corp. in Shenzhen, Guangdong, China. The non-clinical tests (electrical safety, EMC, performance, biocompatibility) are typically performed by the manufacturer or accredited labs on their behalf. The liquid chemical sterilization test reports were submitted to support the reprocessing change.
3. Number of experts used to establish the ground truth for the test set and the qualifications of those experts (e.g. radiologist with 10 years of experience)
Not applicable. No clinical study with a "test set" requiring expert ground truth was conducted for this specific submission. The submission is based on substantial equivalence to a predicate device.
4. Adjudication method (e.g. 2+1, 3+1, none) for the test set
Not applicable. No clinical study requiring adjudication of a test set was conducted for this submission.
5. If a multi reader multi case (MRMC) comparative effectiveness study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance
Not applicable. This device is an endoscope system, not an AI-assisted diagnostic tool for interpretation of images by human readers. The document makes a note that "The prospective clinical value of the enhanced imaging modes has not been demonstrated, and no clinical claims are made" regarding the enhanced imaging modes (EWL, SFI, VIST).
6. If a standalone (i.e. algorithm only without human-in-the-loop performance) was done
Not applicable. This is not an algorithm-only device. It is a medical device system (endoscope, image processor, light source) used by a human operator.
7. The type of ground truth used (expert consensus, pathology, outcomes data, etc)
Not applicable. No clinical study with a "ground truth" was conducted for this submission. The demonstration of performance relies on compliance with recognized standards (IEC, ISO) and comparison of specifications with a legally marketed predicate device.
8. The sample size for the training set
Not applicable. This is not a machine learning or AI-driven submission that would involve a "training set."
9. How the ground truth for the training set was established
Not applicable. As above, no training set was used.
Ask a specific question about this device
(284 days)
The HD-550 video endoscope system, which includes a video colonoscope, image processor, light source, monitor, accessories and other peripheral devices, is intended for endoscopic examination, diagnosis and treatment of the upper and lower gastrointestinal tract.
The EG-550 Series Video Gastroscope has been designed to be used with the image processor. Iight source, monitor and other peripheral devices for endoscopic observation, diagnosis and treatment of the upper digestive tract (including the esophagus, stomach and duodenum).
The EC-550 Series Video Colonoscope has been designed to be used with the image processor, light source, monitor and other peripheral devices for endoscopic observation, diagnosis and treatment of the lower digestive tract (including the anus, rectum, colon and ileocecal segment).
The HD-550 Series Image Processor has been designed to be used with the endoscope, light source, monitor and other peripheral devices for endoscopic observation, diagnosis, treatment, and video recording.
The VLS-55 Series Light Source has been designed to be used with the endoscope, image processor and other peripheral devices for endoscopic observation, diagnosis and treatment.
The proposed device, HD-550 Video Endoscope System, which includes a video gastroscope /video colonoscope, image processor, light source, monitor, accessories and other peripheral devices.
HD-550 Video Endoscope System can be offered in several configurations with the options of different models of primary components
The EG-550 Series Video Gastroscope/ EC-550 Series Video Colonoscope is the hand-held, direct-viewing flexible endoscope used for endoscopy and endoscopic surgery within the upper and lower gastrointestinal tract.
The HD-550 Series Image Processor is a video processing system which is designed to be used with endoscopes, light source, monitor of the proposed system. Apart from the image processing functions, it also provides power supply for the endoscopes.
The VLS-55 Series Light Source provides illumination for endoscopic diagnosis, treatment and video observation.
The provided text is a 510(k) Summary for the Sonoscape Medical Corp. HD-550 Video Endoscope System. It outlines the regulatory process for demonstrating substantial equivalence to a predicate device, as opposed to proving novel performance criteria. Therefore, the document does not contain the information required to answer the prompt for acceptance criteria and a study proving the device meets those criteria, specifically concerning an AI component or complex performance metrics beyond equivalence.
The document states:
- "No clinical study is included in this submission." (Page 7)
- The non-clinical tests were conducted to "verify that the proposed device met all design specifications as was Substantially Equivalent (SE) to the predicate device." (Page 6)
- The comparison focuses on "same intended use, comparable product specification and optical performance" with the predicate device. (Page 14)
The "acceptance criteria" discussed are largely about meeting established safety and performance standards relevant to Class II endoscopes and demonstrating equivalence to a previously cleared device (K173921 HD-500 Video Endoscope System). The performance metrics tested (e.g., color reproduction, resolution, depth of field) are for comparison with the predicate device, not against specific pre-defined acceptance thresholds for a novel AI or diagnostic capability.
Thus, I cannot extract the requested information regarding:
- A table of acceptance criteria and reported device performance (in the context of an AI/diagnostic study).
- Sample sizes used for a test set or data provenance for an AI study.
- Number and qualifications of experts for ground truth establishment.
- Adjudication method for a test set.
- MRMC comparative effectiveness study or human reader improvement with AI.
- Standalone (algorithm-only) performance.
- Type of ground truth used (expert consensus, pathology, outcomes data).
- Sample size for the training set.
- How ground truth for the training set was established.
This document pertains to a traditional medical device (endoscope system) seeking 510(k) clearance based on substantial equivalence, not a device incorporating AI or requiring a new clinical performance study to establish specific diagnostic or therapeutic efficacy.
Ask a specific question about this device
(100 days)
The Digital Color Doppler Ultrasound System is a general-purpose ultrasonic instrument intended for use by a qualified physician for evaluation of Fetal, Abdominal, Pediatric, Small Organ (breast, testes, thyroid), Cephalic (neonatal and adult), Trans-rectal, Trans-vaginal, Peripheral Vascular, Musculo-skeletal (Conventional and Superficial), Cardiac (pediatric and adult), Trans-esoph (Cardiac), Laparoscopic, OB/Gyn and Urology. The Modes of Operation include B, M, PW Doppler, CW Doppler, Color M Doppler, Power Doppler, Tissue Harmonic Imaging, Power Doppler Imaging, Directional Power Doppler Imaging, Tissues Doppler Imaging, Pulse Inversion Harmonic Imaging, 3D/4D Imaging mode, Elastography Imaging, Contrast imaging, Panoramic Imaging, Trapezoid Imaging and their combination modes, and the system is intended to be used in a hospital or medical clinic.
This SonoScape S60 Elite Series Digital Color Doppler Ultrasound System is an integrated preprogrammed color ultrasound imaging system, capable of producing high detail resolution intended for clinical diagnostic imaging applications. The basic principle is that system transmits ultrasonic energy into patient body and implements post processing of received echoes to generate onscreen display of anatomic structures and fluid flow within the body. This system is a Track 3 device that employs a wide array of probes that include linear array, convex array and phased array. This system consists of a mobile console with touch screen and keyboard control panel, power supply module, color LCD monitor and optional probes. This system is a mobile, general purpose, software controlled, color diagnostic ultrasound system. Its basic function is to acquire ultrasound data and to display the image in B-Mode (including Tissue Harmonic Image), M-Mode, TDI, Color-Flow Doppler, Pulsed Wave Doppler, Continued Wave Doppler, Power Doppler and Directional Power Doppler Imaging, or the combination of these modes, Contrast lmaging, Elastography, 3D/4D.
The medical device in question is the Sonoscape S60 Elite Series/S70 Series Digital Color Doppler Ultrasound System (K201059).
Based on the provided document, here's the information regarding its acceptance criteria and supporting study:
1. Table of Acceptance Criteria and Reported Device Performance:
| Acceptance Criteria Category | Specific Standard/Test Name | Device Performance (Result) | Details / Remarks |
|---|---|---|---|
| Electrical Safety | IEC 60601-1:2005+A1:2012 | Passed | Met General requirements for basic safety and essential performance. |
| Electromagnetic Compatibility (EMC) | IEC 60601-1-2:2014 | Passed | Met requirements for electromagnetic disturbances. |
| Acoustic Safety | IEC 60601-2-37:2015 | Passed | Met particular requirements for basic safety and essential performance of ultrasonic medical diagnostic and monitoring equipment. Acoustic Output Limits: Derated ISPTA: 720mW/cm2 maximum, TIS/TIB/TIC: 6.0 maximum, MI: 1.9 maximum for all listed probes (3C-A, C1-6A, C1-6, C2-9, C322, 6CT-A, 6CI-A, 12L-A, 12L-B, 9L-A, L3-9, L741, L742, 10I2, 12LT-A, 12LI-A, 4P-A, 3P-A, S1-5, VE9-5, 6V1, 6V3, 6V7). |
| AIUM/NEMA UD 2:2004 (R2009) | Passed | Met acoustic output measurement standard for diagnostic ultrasound equipment. | |
| Biocompatibility | ISO 10993-5:2009 | Conformed | Met tests for in vitro cytotoxicity. |
| ISO 10993-10:2010 | Conformed | Met tests for irritation and skin sensitization. | |
| Software Verification and Validation | IEC 62304:2006 +A1:2015 | Passed | |
| Functional Equivalence to Predicate Device | Comparison to SonoScape S60 Series (K172082) & Philips EPIQ 5/7 (K172607) & SonoScape P10 Series (K173058) | Substantially Equivalent | Demonstrated similar intended uses, compliance with regulations, consistent acoustic output, and similar probes and technical characteristics. Differences in frequency, operation modes (DPDI vs PDI), and functions are deemed not to raise new risks according to the SE Analyses (5, 6, 7). |
2. Sample Size Used for the Test Set and Data Provenance:
- The document states that non-clinical tests (electrical safety, EMC, acoustic, biocompatibility, software verification/validation) were performed.
- No clinical testing was required for this 510(k) submission.
- Therefore, there is no specific "test set" in terms of patient data for an AI algorithm as typically understood in such studies. The evaluation focused on engineering and performance parameters against established standards.
- Data provenance: Not applicable as no clinical data test set was used.
3. Number of Experts Used to Establish the Ground Truth for the Test Set and Qualifications of Those Experts:
- Not applicable. Since no clinical test set was utilized and no AI algorithm with independent ground truth establishment was conducted, there were no experts needed to establish ground truth for a clinical test set. The device is an ultrasound system, not an AI diagnostic tool requiring clinical ground truth for performance evaluation in this submission.
4. Adjudication Method for the Test Set:
- Not applicable. No clinical test set or subjective interpretations requiring adjudication were part of this 510(k) submission.
5. If a Multi-Reader Multi-Case (MRMC) Comparative Effectiveness Study Was Done, If So, What Was the Effect Size of How Much Human Readers Improve with AI vs Without AI Assistance:
- No. An MRMC comparative effectiveness study was not performed. This submission is for a general-purpose ultrasound system, not an AI-assisted diagnostic tool that would typically undergo such a study to evaluate reader performance with and without AI.
6. If a Standalone (i.e., algorithm only without human-in-the-loop performance) Was Done:
- No. This is not an AI algorithm. It is a digital color Doppler ultrasound system. The evaluation was of the system's compliance with safety and performance standards.
7. The Type of Ground Truth Used:
- For the non-clinical tests, the "ground truth" was based on the requirements and methodologies outlined in the specified international medical device standards (IEC, ISO, AIUM/NEMA). These standards define objective parameters and testing procedures for assessing the safety and performance of ultrasound systems.
8. The Sample Size for the Training Set:
- Not applicable. This submission does not pertain to an AI algorithm that requires a training set.
9. How the Ground Truth for the Training Set Was Established:
- Not applicable. As there is no AI algorithm training set, no ground truth needed to be established for it.
Ask a specific question about this device
(127 days)
The Digital Color Doppler Ultrasound System is a general-purpose ultrasonic instrument intended for use by a qualified physician for evaluation of Fetal, Abdominal, Pediatric, Small Organ (breast, testes, thyroid), Cephalic (neonatal and adult), Trans-rectal, Trans-vaginal, Peripheral Vascular, Muscular, Musculo-skeletal (Conventional and Superficial), Cardiac (pediatric and adult), Trans-esoph.(Cardiac), OB/Gyn and Urology.
This SonoScape X5 Series Digital Color Doppler Ultrasound System is an integrated preprogrammed color ultrasound imaging system, capable of producing high detail resolution intended for clinical diagnostic imaging applications.
The X5 Series system utilizes the ultrasound echo characteristics, transmits ultrasonic energy into patient body, sweeps in a certain direction, processes the signals according to the delay time and the echo strength, and images the organs by using the electronic circuits and backend controller to process, then analyzes the distance and the status of organs; and at the same time, this system utilizes Doppler and auto-correlation technology to image the blood flow and add the color-coding information to the grayscale image of B mode, then displays the image in real time. The probes provided with this system are electrical-acoustical and acoustical-electrical transducers. The probes firstly convert the electric excitation signal to the acoustic signal and transmit the signal into the patient body, then converts the echo signals from the patient body to electric signal. The echo signal is processed and converted by DSC to image signal to output to the LCD display.
This system is a Track 3 device that employs a wide array of probes that include linear array, convex array and phased array.
This system consists of keyboard control panel, power supply module, color LCD monitor and optional probes.
This system (X5 Series Digital Color Doppler Ultrasound System) are additional models (X5 Exp, X5 Pro, X6, X6 Exp, X6 Pro), additional transducers (C1-6, 12L-B, 9L-A, 18L-A, 13L-A, L746, 10L-I, 1012, 6V7, 6V3, 6V3A, C361, VC6-2, C542, C322, 12LT-A, 12LI-A, 6CT-A, 6CI-A, BCC9-5, S1-5, 2P1, CWD5.0, CWD2.0, MPTEE and MPTEE min probes), additional functions (Elastography, Contrast imaging) and updated intended use (Trans-esoph.(Cardiac)) to legally marketed SonoScape X5 (K160258).
The provided document describes the Sonoscape Medical Corp.'s X5 Series Digital Color Doppler Ultrasound System (K182648) and its substantial equivalence to predicate devices, rather than detailing a study that proves the device meets specific performance acceptance criteria for a diagnostic AI algorithm.
The document primarily focuses on demonstrating substantial equivalence to legally marketed predicate devices by comparing intended use, technical characteristics, and probes, as well as adherence to recognized safety and performance standards. No information regarding an AI algorithm's performance or study details (like sample size for test sets, ground truth establishment, expert qualifications, or MRMC studies) is present.
Therefore, I cannot extract the requested information regarding acceptance criteria and the study that proves an AI device meets these criteria, as the provided text pertains to a general diagnostic ultrasound system and its transducers, not an AI-powered diagnostic tool.
The "Performance test" section under "Non-Clinical Tests" lists compliance with electrical safety, EMC, acoustic testing, and software verification/validation standards, indicating the device meets these standards. However, these are general device safety and performance criteria, not specific diagnostic performance criteria for an AI algorithm.
Disclaimer: The provided document is a 510(k) summary for a medical device and does not contain details about the performance of an AI algorithm or a study testing such an algorithm. The information below is based solely on the content available in the provided text, which primarily addresses the substantial equivalence of a physical ultrasound system to predicate devices. As such, many of the requested fields are not applicable or cannot be extracted from this document because it does not describe an AI medical device or its validation study.
Ask a specific question about this device