510(k) Data Aggregation

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    Ice Cooling IPL Hair Removal Device with sapphire treatment window is indicated for the removal of unwanted hair. The device is also indicated for the permanent reduction in hair regrowth, defined as the long-term, stable reduction in the number of hairs regrowing when measured at 6, 9 and 12 months after the completion of a treatment regime.

    Device Description

    Ice Cooling IPL Hair Removal Device with sapphire treatment window is indicated for the removal of unwanted hair. The device is also indicated for the permanent reduction in hair regrowth, defined as the long-term, stable reduction in the number of hairs regrowing when measured at 6, 9 and 12 months after the completion of a treatment regime.

    AI/ML Overview

    N/A

    Ask a Question

    Ask a specific question about this device

    K Number
    K250942

    Validate with FDA (Live)

    Date Cleared
    2025-07-11

    (105 days)

    Product Code
    Regulation Number
    878.4810
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    N/A
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    Ice Cooling IPL Hair Removal Device with sapphire treatment window is indicated for the removal of unwanted hair. The device is also indicated for the permanent reduction in hair regrowth, defined as the long-term, stable reduction in the number of hairs regrowing when measured at 6, 9 and 12 months after the completion of a treatment regime.

    Device Description

    Ice Cooling IPL Hair Removal Device is an over-the-counter, home-use and personal device for hair reduction by using Intense Pulsed Light (IPL). It is designed with dual lamps that work together and can emit mutipulses per shot. It works below the skin's surface and does not involve any cutting or pulling, reducing hair growth with nearly painless pain.

    The device is only powered by the external power adapter and its IPL emission activation is by finger switch. This product adopts sapphire treatment window that is suitable for multiple hair removal areas. It contains a skin sensor to detect appropriate skin contact, if the device is not in full contact with the skin, the device cannot emit the treatment light pulses. Besides, the device has the ice cooling function that will be activated throughout the whole hair removal process to provide users with a more comfortable experience.

    Ice Cooling IPL Hair Removal Device includes the following models: UI20S DB, UI20S RE, UI20S PW, UI20S GP, UI20S GR, UI20S BK, UI20 DB, UI20 RE, UI20 PW, UI20 GP, UI20 GR, UI20 BK. Their intended use, performance and operation are basically identical. The model differences are enclosure color, a detachable accessory cover and skin recognition(only for UI20S series with an accessory cover and with skin recognition). (UI20 series:UI20 DB, UI20 RE, UI20 PW, UI20 GP, UI20 GR, UI20 BK; UI20S series:UI20S DB, UI20S RE, UI20S PW, UI20S GP, UI20S GR, UI20S BK).

    AI/ML Overview

    The provided text does NOT describe a study that proves the device meets specific acceptance criteria related to its performance in hair removal (e.g., efficacy percentages, safety profiles, or long-term hair reduction outcomes). This 510(k) clearance letter primarily focuses on demonstrating substantial equivalence to predicate devices based on technological characteristics, safety, and electrical/software compliance, rather than detailed clinical performance studies with specific patient outcomes.

    The "Summary of performance testing" section specifically lists tests related to:

    • Biocompatibility: Ensuring materials are safe for human contact.
    • Electrical Safety and EMC: Compliance with standards for electrical operation and electromagnetic compatibility.
    • Eye Safety: Compliance with photobiological safety standards.
    • Software Verification and Validation: Ensuring software functions correctly and mitigates risks.
    • Usability: Evaluation of user interface and safety from a human factors perspective.

    These are all crucial for demonstrating the safety and basic functionality of the device, and that it is as safe and effective as previously cleared devices. However, they do not include the type of clinical trial data (e.g., hair regrowth measurements at 6, 9, 12 months) that would typically involve acceptance criteria for efficacy in hair reduction for a new device claiming permanent hair reduction.

    Therefore, I cannot extract a table of acceptance criteria and reported device performance from this document for the stated indications, nor details about sample sizes, ground truth establishment, or expert involvement for performance efficacy studies. The document implicitly relies on the predicate devices having established this efficacy.

    If this were a submission for a novel device, or if the manufacturer needed to prove clinical efficacy independently, this section would contain a detailed description of a clinical study, including:

    • Acceptance Criteria for Efficacy: e.g., "At least X% reduction in hair count at 6 months post-treatment in Y% of subjects."
    • Safety Criteria: e.g., "Incidence of adverse events (e.g., burns, hyper/hypopigmentation) not exceeding Z%."
    • Study Design: Sample size, retrospective/prospective, blinding.
    • Outcome Measures: How hair reduction was measured (e.g., photodocumentation, hair counts).
    • Ground Truth: How hair counts were objectively determined.
    • Statistical Analysis: How the data proved the criteria were met.

    Conclusion:

    Based only on the provided FDA 510(k) clearance letter, I cannot fulfill most of the requested points regarding acceptance criteria and performance studies because the document focuses on demonstrating substantial equivalence based on technological and safety standards, not on presenting new clinical efficacy data for hair removal. The implicit "proof" of efficacy lies in the substantial equivalence to predicate devices that have already established their efficacy for the stated indications.

    The document states:
    "Performance data supports that the device is safe and as effective as the predicate devices for its intended use." This is a claim of equivalence, not a direct presentation of primary efficacy data for this specific device.

    Therefore, the requested table and specific details regarding MRMC studies, standalone performance, ground truth derivation for efficacy, and training/test set sample sizes for hair removal efficacy are not present in this 510(k) summary. The "performance data" referred to in the document pertains to the safety and engineering characteristics listed in the "Summary of performance testing" section.

    Ask a Question

    Ask a specific question about this device

    K Number
    K250938

    Validate with FDA (Live)

    Date Cleared
    2025-05-23

    (56 days)

    Product Code
    Regulation Number
    878.4810
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    N/A
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    Ice Cooling IPL Hair Removal Device with sapphire treatment window is indicated for the removal of unwanted hair. The device is also indicated for the permanent reduction in hair regrowth, defined as the long-term, stable reduction in the number of hairs regrowing when measured at 6, 9 and 12 months after the completion of a treatment regime.

    Device Description

    Ice Cooling IPL Hair Removal Device is an over-the-counter, home-use and personal device for hair reduction by using Intense Pulsed Light (IPL). It is designed with a lamp that can emit single pulse, double pulse or triple pulse per shot. It works below the skin's surface and does not involve any cutting or pulling, reducing hair growth with nearly painless pain. The device is only powered by the external power adapter and its IPL emission activation is by finger switch. This product adopts sapphire treatment window that is suitable for multiple hair removal areas. It contains a skin sensor to detect appropriate skin contact, if the device is not in full contact with the skin, the device cannot emit the treatment light pulses. Besides, the device has the ice cooling function that will be activated throughout the whole hair removal process to provide users with a more comfortable experience.

    AI/ML Overview

    This FDA 510(k) clearance letter pertains to an Ice Cooling IPL Hair Removal Device, not an AI/algorithm-based diagnostic device. Therefore, the information typically requested in your prompt regarding acceptance criteria and studies proving the device meets those criteria (e.g., sample size for test/training sets, data provenance, expert ground truth, MRMC studies, standalone performance, etc.) is not applicable to this type of medical device clearance.

    The 510(k) summary for this IPL device focuses on demonstrating substantial equivalence to predicate devices through:

    • Identical Intended Use: Hair removal and permanent reduction in hair regrowth.
    • Similar Technological Characteristics: Comparison of physical dimensions, power supply, light source, energy medium, wavelength range, energy density, output energy, spot size, pulse duration, pulsing control, delivery device, output intensity levels, and software/firmware. Minor differences are addressed by showing they do not raise new safety or efficacy concerns.
    • Performance Data (Non-Clinical Testing):
      • Biocompatibility Testing: Ensuring materials in contact with the body are safe (per ISO 10993 series).
      • Electrical Safety and EMC (Electromagnetic Compatibility): Compliance with relevant IEC 60601 standards to ensure electrical safety and proper operation in the presence of electromagnetic disturbances.
      • Light Safety: Compliance with IEC 62471 for photobiological safety.
      • Software Verification and Validation: Ensuring software functions correctly and mitigates hazards, consistent with a "Basic Documentation Level."
      • Usability: Evaluation and validation per IEC 60601-1-6 and FDA guidance on Human Factors and Usability Engineering.

    To directly answer your prompt, but acknowledging its non-applicability to this specific device:

    1. A table of acceptance criteria and the reported device performance:

      Acceptance Criteria (General for IPL Device)Reported Device Performance (Summary of Non-Clinical Testing)
      Biocompatibility (Safety of body-contacting parts)Passed ISO 10993-10 (skin sensitization), ISO 10993-23 (irritation), ISO 10993-5 (in vitro cytotoxicity).
      Electrical Safety (Prevention of electric shock, fire, etc.)Passed IEC 60601-1 (general safety), IEC 60601-1-2 (EMC), IEC 60601-1-11 (home healthcare), IEC 60601-2-57 (non-laser therapeutic equipment), IEC 60601-2-83 (home light therapy equipment).
      Electromagnetic Compatibility (EMC)Passed IEC 60601-1-2 (EMC requirements and tests).
      Light Safety (Patient eye/skin safety from light emission)Passed IEC 62471 (photobiological safety of lamps and lamp systems).
      Software Functionality and SafetySoftware documentation consistent with "Basic Documentation Level" submitted. System testing demonstrated all software requirements met and hazards mitigated to acceptable levels.
      Usability (Safe and effective use by intended user)Evaluated and validated according to IEC 60601-1-6 and FDA guidance "Applying Human Factors and Usability Engineering to Medical Devices."
      Performance within specified output parameters (Energy density, wavelength, etc.)Output specifications (e.g., energy density 1.8-6.67 J/cm², wavelength 550-1200nm) are provided and considered substantially equivalent to predicates, with minor differences justified as not raising safety/efficacy issues. Temperature Test Report and Usability evaluation conducted to verify safe multi-pulse use.
    2. Sample sizes used for the test set and the data provenance: Not applicable to this type of device and submission. The "test set" here refers to specific non-clinical engineering tests (e.g., electrical safety, biocompatibility) where sample sizes are determined by standard testing protocols for equipment, not by a patient/image dataset. The data provenance is primarily from the manufacturer's internal testing.

    3. Number of experts used to establish the ground truth for the test set and the qualifications of those experts: Not applicable. Ground truth for an IPL device is established through engineering specifications and physical measurements, and by adherence to recognized consensus standards for safety and performance, not by expert interpretation of clinical data in the context of diagnostic AI.

    4. Adjudication method for the test set: Not applicable. Adjudication methods like 2+1 or 3+1 apply to clinical data interpretation, typically in diagnostic studies.

    5. If a multi reader multi case (MRMC) comparative effectiveness study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance: Not applicable. This is an IPL device, not an AI-assisted diagnostic tool.

    6. If a standalone (i.e. algorithm only without human-in-the loop performance) was done: Not applicable. There is no AI algorithm being evaluated for standalone performance in this submission.

    7. The type of ground truth used: For this device, "ground truth" refers to:

      • Physical Measurements/Engineering Specifications: Ensuring the device operates within its stated parameters (e.g., energy output, wavelength).
      • Compliance with Recognized Consensus Standards: Adherence to standards like IEC 60601 series, IEC 62471, and ISO 10993 series, which define safety and performance requirements.
      • Usability Testing Outcomes: Observing real users to ensure the device can be used safely and effectively.
    8. The sample size for the training set: Not applicable. There is no "training set" in the context of an IPL device clearance, as it's not an AI/machine learning model.

    9. How the ground truth for the training set was established: Not applicable for the same reason as above.

    Ask a Question

    Ask a specific question about this device

    K Number
    K243749

    Validate with FDA (Live)

    Date Cleared
    2025-04-08

    (124 days)

    Product Code
    Regulation Number
    882.1275
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    N/A
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    Jmoon Conductive Gel is intended to be used with microcurrent devices to improve skin conductivity.

    Device Description

    The Jmoon Conductive Gel is a clear, viscous and chloride-free formulation. The gel is to be applied to the area under an electrode to reduce the impedance of the contact interface between the electrode surface and the skin.

    AI/ML Overview

    The provided FDA 510(k) clearance letter and summary for the Jmoon Conductive Gel do not contain any information regarding clinical studies with human participants or the use of AI/algorithms. The document primarily focuses on the device's substantial equivalence to a predicate device based on its physical, chemical, and biological characteristics, as well as biocompatibility and shelf-life testing.

    Therefore, many of the requested categories cannot be populated from the provided text.

    Here's a breakdown of the available information:

    Acceptance Criteria and Reported Device Performance

    Acceptance CriteriaReported Device PerformanceStudy that Proves Acceptance Criteria
    Intended UseJmoon Conductive Gel is intended to be used with microcurrent devices to improve skin conductivity.Performance of the device characteristics (physical, chemical, biological) were evaluated. The conclusion states that the subject device is substantially equivalent to the predicate device for its intended use.
    Target PopulationAdults 18 years of age or olderNot explicitly tested, but matches predicate device.
    Environment of UseHomeNot explicitly tested, but matches predicate device.
    Body ContactIntact skinBiocompatibility testing (ISO 10993-1, -5, -10, -23)
    Conductive MaterialSodium SaltPerformance testing (conductivity)
    SterilizationNon-sterileNot applicable (matches predicate)
    BiocompatibilityComplies with ISO 10993-1, ISO 10993-5, ISO 10993-10, ISO 10993-23Biocompatibility Testing (ISO 10993-5: In Vitro Cytotoxicity, ISO 10993-10: Skin Sensitization, ISO 10993-23: Irritation)
    Chemical SafetyNon-OSHA PELChemical Safety testing (not detailed, but stated as compliant)
    pH5.0 ~ 7.0Performance testing (pH)
    Shelf-life3 yearsAccelerated stability testing (3 years)
    Physical CharacteristicsMeets intended specificationPerformance testing (appearance, color, odor, viscosity)
    Microbiological GrowthMeets intended specificationPerformance testing (microbiological growth)

    Study Details Based on Provided Information:

    1. Sample size used for the test set and the data provenance: Not applicable. The studies mentioned (biocompatibility, shelf-life, performance testing) refer to laboratory-based evaluations of the gel's properties, not clinical studies with a test set of human subjects or images.
    2. Number of experts used to establish the ground truth for the test set and the qualifications of those experts: Not applicable. This information is relevant for studies involving human interpretation or clinical outcomes, which are not present in this document.
    3. Adjudication method (e.g. 2+1, 3+1, none) for the test set: Not applicable. No human interpretation requiring adjudication was involved.
    4. If a multi reader multi case (MRMC) comparative effectiveness study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance: Not applicable. The device is a conductive gel, not an AI-based diagnostic or assistive tool.
    5. If a standalone (i.e. algorithm only without human-in-the-loop performance) was done: Not applicable. This is not an algorithm-based device.
    6. The type of ground truth used (expert consensus, pathology, outcomes data, etc.): The "ground truth" for this device would be established through laboratory standards and validated test methods for chemical, physical, and biological properties, as well as regulatory standards for biocompatibility (e.g., ISO 10993 series).
    7. The sample size for the training set: Not applicable. This is not an AI/machine learning device that requires a training set.
    8. How the ground truth for the training set was established: Not applicable. No training set was used.
    Ask a Question

    Ask a specific question about this device

    K Number
    K243393

    Validate with FDA (Live)

    Date Cleared
    2025-02-03

    (95 days)

    Product Code
    Regulation Number
    882.5890
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    N/A
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    JMOON NouvelleSkin facial toning device is intended for facial stimulation and indicated for overthe-counter cosmetic use.
    JMOON NouvelleSkin facial toning device is an over-the-counter device that emits energy in the red and near-infrared spectrum, designed for the treatment of facial wrinkles.

    Device Description

    Jmoon NouvelleSkin Facial Toning device is an at-home handled device that provides an advanced, easy-to-use and efficient solution for better facial wellness. This device includes microcurrent, red and infra-red light LED, which allow you to customize your treatments according to your face skin. The device provides indicator lights and beeps feedback to guide the user during the treatment cycle.
    The microcurrent therapy will deliver 3 different low-level electrical microcurrent impulses on face within a few minutes to complete facial stimulation. The red light and infra-red therapy is a treatment that uses red light to reportedly improve your skin's appearance, like reducing wrinkles.

    AI/ML Overview

    The provided text describes a 510(k) premarket notification for the JMOON NouvelleSkin Facial Toning Device. The submission aims to demonstrate substantial equivalence to predicate devices, rather than proving performance against specific acceptance criteria through a clinical study with real-world data and expert adjudication. Therefore, much of the requested information (like sample size for test set, data provenance, number of experts, adjudication method, MRMC study, standalone performance, and ground truth for training set) is not applicable or not present in the provided document.

    However, the document does contain "acceptance criteria" in the form of conformance to various safety and performance standards for non-clinical testing.

    Here's the breakdown of the information based on the provided text:

    1. A table of acceptance criteria and the reported device performance

    The acceptance criteria for this device are its conformance to recognized safety and performance standards. The reported performance is that the device "Conforms" to these standards.

    Test TypeStandardAcceptance Criteria (Stated)Reported Device Performance
    Electrical safetyIEC 60601-1; IEC TR 60601-4-2Conforms to standardConforms
    EMCIEC 60601-1-2Conforms to standardConforms
    Home healthcare environmentIEC 60601-1-6; IEC 60601-2-83; IEC 60601-1-11Conforms to standardConforms
    Safety of DeviceIEC 62471; IEC 60601-2-10; IEC 60601-2-57Conforms to standardConforms
    BiocompatibilityISO 10993-1; ISO 10993-5; ISO 10993-10; ISO 10993-23Conforms to standardConforms

    2. Sample size used for the test set and the data provenance (e.g. country of origin of the data, retrospective or prospective)

    The document explicitly states: "No clinical test data was used to support the decision of substantial equivalence."
    The testing performed was non-clinical (lab bench testing). Therefore, there is no "sample size for the test set" in the context of human subjects or clinical data, nor is there data provenance in terms of country of origin or retrospective/prospective studies.

    3. Number of experts used to establish the ground truth for the test set and the qualifications of those experts (e.g. radiologist with 10 years of experience)

    Not applicable. As no clinical test data was used, no experts were needed to establish ground truth for a test set based on human subjects. The acceptance criteria were based on adherence to international technical standards, which are established by expert consensus in regulatory and technical bodies.

    4. Adjudication method (e.g. 2+1, 3+1, none) for the test set

    Not applicable. No clinical test set with human subject data requiring adjudication was used.

    5. If a multi-reader multi-case (MRMC) comparative effectiveness study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance

    Not applicable. No MRMC study was conducted, as the device is not an AI-assisted diagnostic or interpretive tool, and no clinical studies were performed.

    6. If a standalone (i.e. algorithm only without human-in-the-loop performance) was done

    This concept is not directly applicable to this device, which is a physical facial toning device. However, the non-clinical testing evaluates the device's standalone physical, electrical, and biocompatibility performance against specified standards. The results indicate that the device "Conforms" to these standards in a standalone capacity.

    7. The type of ground truth used (expert consensus, pathology, outcomes data, etc.)

    The "ground truth" for the non-clinical testing is compliance with the specified international standards (e.g., IEC 60601-1, ISO 10993 series). These standards represent an expert consensus on safety and performance requirements for medical devices.

    8. The sample size for the training set

    Not applicable. The device is not based on a machine learning algorithm; therefore, there is no "training set" in the conventional sense of AI/ML development.

    9. How the ground truth for the training set was established

    Not applicable. There is no training set for this device.

    Ask a Question

    Ask a specific question about this device

    K Number
    K243492

    Validate with FDA (Live)

    Date Cleared
    2025-01-10

    (59 days)

    Product Code
    Regulation Number
    878.4810
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    Ulike Reglow Light Therapy Device is an over the counter device that is intended for use in the treatment of full face wrinkles and treatment of mild to moderate inflammatory acne.

    Device Description

    Ulike Reglow Light Therapy Device adopts light emitting diodes (LED) in the 630mm ± 10nm,830nm ± 10nm,590mm±10nm and 465nm±10nm spectrum to irradiate on the face to realize its therapeutic effect. The Ulike Reglow Light Therapy Device adopts the form of a mask that contains LEDs on the inner surface of the main unit. A controller is connected to the main unit to control the device, such as turn on/off the device, switch mode. Power adapter is provided to charge the battery contained in the controller. To use the device, user should place the mask over the face and use the controller to operate. To prevent irradiation of LED lights to eyes during the treatment, Ulike Reglow Light Therapy Device has incorporated protective eye-shield which blocks light energy from LEDs.

    AI/ML Overview

    The provided text describes the regulatory clearance for the "Ulike Reglow Light Therapy Device (UM10)" based on its substantial equivalence to predicate devices. It does not present any clinical study data or acceptance criteria related to the device's performance for its intended therapeutic effects (wrinkle reduction and acne treatment).

    Instead, the document focuses on non-clinical performance data for safety and electrical characteristics required for FDA clearance. Therefore, I cannot generate the requested table or answer several of your questions (1, 5, 6, 7, 8, 9) because the information is not present in the provided text.

    The text does mention the following:

    • Acceptance Criteria for Non-Clinical Tests: The acceptance criteria for the non-clinical tests (biocompatibility, electrical safety, light safety, software, usability) are that the device "passed" the respective standards (e.g., ISO 10993, IEC 60601 series, IEC 62471). Specific numerical performance metrics for these tests are not provided.
    • Study Proving Device Meets Acceptance Criteria: The study proving the device meets the acceptance criteria is the performance of the listed non-clinical tests.

    Here's what can be extracted from the document regarding the non-clinical tests:


    1. Table of Acceptance Criteria and Reported Device Performance (for Non-Clinical Tests)

    Test CategoryAcceptance Criteria (Standard)Reported Device Performance
    BiocompatibilityUse of International Standard ISO 10993-1, 'Biological Evaluation of Medical Devices-Part 1: Evaluation and Testing Within a Risk Management Process, documented, as recognized by FDA. Includes: ISO 10993-10:2021 (Skin sensitization), ISO 10993-23:2021 (Irritation), ISO 10993-5:2009 (In Vitro Cytotoxicity)."The following testing was performed to, and passed, including: ISO 10993-10:2021, ISO 10993-23:2021, ISO 10993-5:2009." ("passed" implies meeting the standards' requirements)
    Electrical SafetyIEC 60601-1:2005+A1:2012+A2:2020 (General requirements for basic safety and essential performance); IEC 60601-1-2:2014+A1:2020 (Electromagnetic disturbances); IEC 60601-1-11:2015+A1:2020 (Home Healthcare Environment); IEC 60601-2-57:2011 (Non-laser source equipment); IEC 60601-2-83:2019 (Home light therapy equipment); IEC 62133-2:2017 (Secondary cells/batteries - Lithium systems)."Electrical safety and EMC testing was performed to, and passed, as per the following standards: IEC 60601-1, IEC 60601-1-2, IEC 60601-1-11, IEC 60601-2-57, IEC 60601-2-83, IEC 62133-2." ("passed" implies meeting the standards' requirements)
    Light SafetyIEC 62471:2006 (Photobiological safety of lamps and lamp systems)."Light Safety: IEC 62471:2006. (Implied: Passed, based on overall conclusion of substantial equivalence)"
    Software V&VBasic Documentation Level standards, demonstrating all software requirement specifications are met and all software hazards mitigated to acceptable risk levels."System testing presented in this 510(k) demonstrated that all software requirement specifications are met and all software hazards have been mitigated to acceptable risk levels."
    UsabilityIEC 60601-1-6 (Usability) and FDA guidance "Applying Human Factors and Usability Engineering to Medical Devices, issued on FEBRUARY 2016.""The product usability has been evaluated and validated according to the following standard and FDA guidance: IEC 60601-1-6, Applying Human Factors and Usability Engineering to Medical Devices." (Implied: Passed/validated)

    2. Sample size used for the test set and the data provenance (e.g. country of origin of the data, retrospective or prospective)

    • Sample Size: Not applicable. The document discusses non-clinical tests (electrical safety, biocompatibility, etc.) performed on the device itself, not on a human test set. There is no mention of a clinical test set.
    • Data Provenance: Not applicable for clinical data. The tests are general product safety and performance tests against international standards.

    3. Number of experts used to establish the ground truth for the test set and the qualifications of those experts (e.g. radiologist with 10 years of experience)

    • Not applicable. There is no mention of an expert panel or ground truth establishment for a clinical test set as no clinical study data is presented.

    4. Adjudication method (e.g. 2+1, 3+1, none) for the test set

    • Not applicable. There is no clinical test set mentioned.

    5. If a multi reader multi case (MRMC) comparative effectiveness study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance

    • No, this document does not describe an MRMC study. The device is a light therapy device, not an AI-assisted diagnostic tool.

    6. If a standalone (i.e. algorithm only without human-in-the-loop performance) was done

    • Not applicable. This is not an algorithm-based device that would require standalone performance evaluation in the context of diagnostic AI.

    7. The type of ground truth used (expert consensus, pathology, outcomes data, etc)

    • Not applicable. There is no clinical study data for therapeutic efficacy presented in this document. The ground truth for the non-clinical tests is compliance with published international industry standards.

    8. The sample size for the training set

    • Not applicable. This document is for a medical device (light therapy) which implies physical product testing, not a machine learning model that would require a training set.

    9. How the ground truth for the training set was established

    • Not applicable. (See #8)
    Ask a Question

    Ask a specific question about this device

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    Ice Cooling IPL Hair Removal Device with sapphire treatment window is indicated for the removal of unwanted hair. The device is also indicated for the permanent reduction in hair regrowth, defined as the long-term, stable reduction in the number of hairs regrowing when measured at 6, 9 and 12 months after the completion of a treatment regime.

    Device Description

    Ice Cooling IPL Hair Removal Device is an over-the-counter, home-use and personal device for hair reduction by using Intense Pulsed Light (IPL). It is designed with dual lamps that work together and can emit mutipulses per shot. It works below the skin's surface and does not involve any cutting or pulling, reducing hair growth with nearly painless pain. The device is only powered by the external power adapter and its IPL emission activation is by finger switch. This product adopts sapphire treatment window that is suitable for multiple hair removal areas. It has skin-safe detection. It contains a skin sensor to detect appropriate skin contact, if the device is not in full contact with the skin, the device cannot emit the treatment light pulses. Besides, the device has the ice cooling function that will be activated throughout the whole hair removal process to provide users with a more comfortable experience.

    AI/ML Overview

    The provided text is an FDA 510(k) clearance letter for an "Ice Cooling IPL Hair Removal Device." It describes the device, its intended use, and a comparison with predicate devices to establish substantial equivalence. However, this document does not contain, nor is it expected to contain, the detailed acceptance criteria and study results typically found in a clinical study report for device performance, especially for AI/ML-driven devices involving expert interpretation or comparative effectiveness studies.

    The document focuses on:

    • Substantial Equivalence: Demonstrating the new device is as safe and effective as legally marketed predicate devices.
    • Performance Data (Non-Clinical): Summarizing tests for biocompatibility, electrical safety and EMC, eye safety, software verification and validation, and usability. These are largely engineering and safety tests rather than evaluations of device clinical effectiveness (e.g., hair removal efficacy).

    Therefore, I cannot fulfill your request for acceptance criteria and study details related to "device performance" in the context of an AI/ML device (e.g., human reader improvement with AI assistance, standalone algorithm performance, ground truth establishment by experts, MRMC studies) because this information is not present in the provided FDA clearance letter.

    The device described is an IPL (Intense Pulsed Light) hair removal device, which is a physical device that emits light to reduce hair growth. It does have software/firmware control, but it's not presented as an AI/ML-driven diagnostic or imaging interpretation device that would involve the kind of "acceptance criteria" you've outlined (e.g., related to sensitivity, specificity, or expert consensus on interpretations). The "performance data" here relates to the safety and fundamental operation of the physical device as required for a 510(k) submission.

    Ask a Question

    Ask a specific question about this device

    K Number
    K241205

    Validate with FDA (Live)

    Date Cleared
    2024-09-09

    (132 days)

    Product Code
    Regulation Number
    878.4810
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    N/A
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    Ice Cooling IPL Hair Removal Device with sapphire treatment window is indicated for the removal of unwanted hair. The device is also indicated for the permanent reduction in hair regrowth, defined as the long-term, stable reduction in the number of hairs regrowing when measured at 6, 9 and 12 months after the completion of a treatment regime.

    Device Description

    Ice Cooling IPL Hair Removal Device is an over-the-counter, home-use and single-person-use device for hair reduction by using Intense Pulsed Light (IPL). It works below the skin's surface and does not involve any cutting or pulling, reducing hair growth with minimal pain. This product emits light pulses and is designed to be suitable for multiple hair removal areas (such as: lips, underarms, bikini lines, arms, legs, etc.). The device is only powered by the external power adapter and its IPL emission activation is by finger switch. The device contains a skin sensor to detect appropriate skin contact. If the device is not in full contact with the skin, the device cannot emit the treatment light pulses. The device includes a cooling function to cool the skin during the hair removal process to provide users with a more comfortable experience.

    AI/ML Overview

    The provided text is a 510(k) summary for the Shenzhen Ulike Smart Electronics Co., Ltd. Ice Cooling IPL Hair Removal Device. It describes the device, its intended use, and its comparison to predicate devices, along with performance testing. However, it does not contain the specific details about clinical study results, acceptance criteria, or the methodology that would be required to answer all the questions in the prompt.

    Here's an analysis based on the available information:

    Acceptance Criteria and Reported Device Performance:
    The document does not explicitly state quantitative acceptance criteria for performance metrics related to hair removal (e.g., specific percentages of hair reduction deemed acceptable). It only mentions the "permanent reduction in hair regrowth, defined as the long-term, stable reduction in the number of hairs regrowing when measured at 6, 9 and 12 months after the completion of a treatment regime" as part of the Indications for Use.

    The document does not report specific quantitative performance data for the hair reduction effectiveness of the device. Instead, it refers to "Performance data supports that the device is safe and as effective as the predicate devices for its intended use" as a general statement for substantial equivalence.

    Therefore, for the specific request of a table of acceptance criteria and reported device performance related to the primary indication of hair removal, the necessary information is not present in the provided text.

    The document does list standards and tests for safety and general performance, which implies that the device met the requirements of these standards. For example:

    Acceptance Criteria (Implied by standard compliance)Reported Device Performance (Implied by passing tests)
    Biocompatibility standards (ISO 10993-5, -10, -23) are met.Device passed biocompatibility testing.
    Electrical safety standards (IEC 60601-1, -1-2, -1-11, -2-57, -2-83) are met.Device passed electrical safety and EMC testing.
    Light safety standard (IEC 62471) is met.Device passed light safety testing.
    Software requirements are met and hazards mitigated.Software documentation submitted; system testing demonstrated specifications met and hazards mitigated.
    Usability standard (IEC 60601-1-6) and FDA guidance for human factors are met.Product usability evaluated and validated.

    Missing Information:

    The following information is not available in the provided text:

    1. Sample size used for the test set and the data provenance: There is no mention of a clinical test set or the number of participants.
    2. Number of experts used to establish the ground truth for the test set and qualifications: This information would be relevant for clinical studies, which are not detailed here.
    3. Adjudication method for the test set: Not applicable as no clinical test set is described.
    4. If a multi-reader multi-case (MRMC) comparative effectiveness study was done, and effect size: This type of study is not mentioned. The device is a "home-use" device, so human-in-the-loop performance is not evaluated in the context of an MRMC study with AI assistance.
    5. If a standalone (i.e. algorithm only without human-in-the-loop performance) was done: While the device functions autonomously for hair removal, the performance described is purely device-centric rather than an "algorithm only" evaluation in the context of diagnostic AI.
    6. The type of ground truth used: As no clinical study results are detailed, no specific ground truth for hair removal efficacy is provided or referenced.
    7. The sample size for the training set: Not applicable as this document does not describe the development or evaluation of an AI/ML training set.
    8. How the ground truth for the training set was established: Not applicable.

    Summary based on available info:

    The document primarily focuses on establishing "substantial equivalence" to predicate devices through technical comparisons and compliance with relevant safety and performance standards (biocompatibility, electrical safety, light safety, software, usability). It asserts that performance data supports the device's safety and effectiveness, but it does not present the detailed clinical study design, results, or specific acceptance criteria for hair removal efficacy that would directly answer your questions about acceptance criteria and how a study proves it. For a medical device of this type, a clinical study would typically be conducted, and those results would contain the information you are requesting. This 510(k) summary only notes that such data was "provided in support of the substantial equivalence determination" but does not elaborate on the specific findings or methodology of that data.

    Ask a Question

    Ask a specific question about this device

    Page 1 of 1