510(k) Data Aggregation
(88 days)
Ask a specific question about this device
(116 days)
uCT 780 is a computed tomography x-ray system intended to produce cross-sectional images of the body by computer reconstruction of x-ray transmission data taken at different angles and planes and indicated for the whole body (including head, neck, cardiac and vascular).
uCT 780 is intended to be used for low dose CT lung cancer screening for the early detection of lung nodules that may represent cancer. The screening must be performed within the established inclusion criteria of programs / protocols that have been approved and published by either a governmental body or professional medical society.
- Please refer to clinical literature, including the results of the National Lung Screening Trial (N Engl J Med 2011; 365:395-409) and subsequent literature, for further information.
uWS-CT-Dual Energy Analysis is a post-processing software package that accepts UIH CT images acquired using different tube voltages and/or tube currents of the same anatomical location. The various materials of an anatomical region of interest have different attenuation coefficients, which depend on the used energy. These differences provide information on the chemical composition of the scanned body materials and enable images to be generated at multiple energies within the available spectrum. uWS-CT-Dual Energy Analysis software combines images acquired with low and high energy spectra to visualize this information.
The Computed Tomography X-ray system, uCT 780, is intended to produce cross-sectional images of the patient by computer reconstruction of X-ray transmission data taken at different angles and planes. These images may be obtained either with or without contrast.
This 510(k) is to request modifications for the cleared Computed Tomography X-ray system uCT 780. uCT 780 has been previously cleared by FDA via K241079.The modification performed on the uCT 780 (K241079) in this submission is due to the addition of a new high voltage generator. At the same time, we introduce a mobile configuration which supports installation in vehicles. A summary of the modified hardware is provided below:
- A new model of high voltage generator uXG 100 has been introduced in the mobile configuration, and the predicate model CT140N80X4889 is still used in other non-mobile configurations.
- A tilt lock has been introduced to the gantry and a horizontal movement lock has been introduced to the standard config patient table, and the system software has been updated to include the relevant controls and prompts.
- PSC has been modified, including adding a shock-absorbing base, strengthening the sheet metal structure, and optimizing the fixing method of PSC.
N/A
Ask a specific question about this device
(152 days)
Digital Medical X-ray Imaging System is intended to acquire X-ray images of the human body by a qualified technician, examples include acquiring two-dimensional X-ray images of the skull, spinal column, chest, abdomen, extremities, limbs and trunk. The visualization of such anatomical structures provide visual evidence to radiologists and clinicians in making diagnostic decisions. This device is not intended for mammography.
uDR Arria and uDR Aris are two models of Digital Medical X-ray Imaging System developed and manufactured by Shanghai United Imaging Healthcare Co., Ltd(UIH). The system is equipped with imaging chain components and utilizes enhanced processing technology, so it can offer radiographic images with high image quality. The intuitive user interface and easy-to-use functions provide clinical users with a experience during patient examination and image processing.
The system is intended to acquire X-ray images of the human body by a qualified technician, examples include acquiring two-dimensional X-ray images of the skull, spinal column, chest, abdomen, extremities, limbs and trunk. The visualization of such anatomical structures provide visual evidence to radiologists and clinicians in making diagnostic decisions. This device is not intended for mammography.
Here's a breakdown of the acceptance criteria and study details for the uDR Arria and uDR Aris devices, based on the provided FDA 510(k) clearance letter:
1. Table of Acceptance Criteria and Reported Device Performance
The 510(k) summary provided details for two specific optional software functions: uVision and uAid. Other aspects of the device are X-ray imaging systems, for which the primary "performance" is image quality, which is evaluated subjectively through clinical image evaluation rather than quantitative metrics and acceptance criteria.
| Feature | Acceptance Criteria | Reported Device Performance |
|---|---|---|
| uVision (Optional) | When users employ the uVision function for automatic positioning, the automatically set system position and field size will meet clinical technicians' criteria with 95% compliance. | In 95% of patient positioning processes, the light field and equipment position automatically set by uVision can meet the clinical positioning and shooting requirements. In the remaining 5% of cases, based on the light field and system position automatically set by the equipment, technicians still need to make manual adjustments. |
| uAid (Optional) | A 90% pass rate for "Grade A" images, aligning with industry standards (e.g., European Radiology and ACR-AAPM-SPR Practice Parameter guidelines which state Grade A image rates in public hospitals generally range between 80% and 90%).Implicitly, for specific criteria: Sensitivity and specificity of whether there is a foreign body, whether the lung field is intact, and whether the scapula is open all exceed 0.9. | Average time of uAid algorithm: 1.359 seconds (longest does not exceed 2 seconds).Maximum memory occupation of uAid algorithm: not more than 2GB.Sensitivity and specificity of whether there is a foreign body, whether the lung field is intact, and whether the scapula is open all exceed 0.9.The uAid function can correctly identify four types of results: Foreign object, Incomplete lung fields, Unexposed shoulder blades, and Centerline deviation, making classifications (Green: qualified, Yellow: secondary, Red: waste). |
| Clinical Image Quality | Each image was reviewed with a statement indicating that image quality is sufficient for clinical diagnosis. | Sample images of chest, abdomen, spine, pelvis, upper extremity and lower extremity were provided. A board-certified radiologist evaluated the image quality for sufficiency for clinical diagnosis. |
2. Sample Size Used for the Test Set and Data Provenance
uVision:
- Sample Size: The evaluation results provided are from a single week's worth of data, totaling 328 chest cases and 20 full spine or full lower limb stitching cases from the specified period (2024.12.17 - 2024.12.23).
- Data Provenance: The device with uVision function (serial number 11XT7E0001) has been in use for over a year at a hospital. The testing data includes individuals of all genders and varying heights capable of standing independently. It is prospective in the sense that it was collected during routine clinical operation after installation and commissioning. The country of origin is not explicitly stated but implied to be China, given the manufacturer's location.
uAid:
- Sample Size: The document does not provide a single total number for the test set. Instead, it breaks down the data by age/gender distribution and the distribution of positive/negative cases for each criterion.
- Age/Gender Distribution: Total 5680 patients (sum of all male/female/no age/no age, no gender categories).
- Criterion-specific counts:
- Lung field segmentation: 465 Negative, 31 Positive
- Spinal centerline segmentation: 815 Negative, 68 Positive
- Shoulder blades segmentation: 210 Negative, 1089 Positive
- Foreign object: 1078 Negative, 3080 Positive
- Data Provenance: Data collection started in October 2017, from the uDR 780i and "different cooperative hospitals." The study was approved by the institutional review board. The data is stored in DICOM format. It is retrospective, collected from existing hospital data. Country of origin not explicitly stated but implied to be China.
3. Number of Experts Used to Establish the Ground Truth for the Test Set and Their Qualifications
uVision:
- Number of Experts: The results were "statistically analyzed by clinical experts." The exact number is not specified, but the term "experts" suggests more than one.
- Qualifications: "Clinical experts" is a general term. Specific qualifications (e.g., radiologist, radiologic technologist, years of experience) are not provided.
uAid:
- Ground truth establishment for uAid's classification categories (Foreign object, Incomplete lung fields, Unexposed shoulder blades, Centerline deviation) is not explicitly described in terms of experts or their qualifications. The acceptance criteria reference "relevant research and literature" and "industry guidelines and standards," suggesting that the ground truth for image quality categorization might be derived from these established definitions.
Clinical Image Quality (General):
- Number of Experts: "A board certified radiologist." This indicates one expert.
- Qualifications: "Board certified radiologist." This is a specific and high qualification for evaluating radiographic images.
4. Adjudication Method for the Test Set
uVision:
- The document states that the results were "statistically analyzed by clinical experts." This implies some form of review and judgment, but a formal adjudication method (e.g., 2+1, 3+1) is not described. It's presented as an evaluation of the system's compliance with technician criteria.
uAid:
- The method for establishing ground truth classifications for uAid's criteria (Foreign object, Incomplete lung fields, Unexposed shoulder blades, Centerline deviation) is not detailed, so an adjudication method is not provided.
5. If a Multi-Reader Multi-Case (MRMC) Comparative Effectiveness Study Was Done
- No, an MRMC comparative effectiveness study was not explicitly described for either uVision or uAid or the overall device. The studies focused on evaluating the standalone performance of the AI features and the overall clinical image quality (subjective expert review), rather than comparing human readers with and without AI assistance.
6. If a Standalone (i.e., algorithm only without human-in-the-loop performance) Was Done
- Yes, standalone performance was evaluated for both uVision and uAid.
- uVision: The reported performance is how well the "automatically set system position and field size" meet "clinical technicians' criteria" when the uVision function is used for automatic positioning. While technicians use the function, the performance metric itself is about the accuracy of the system's automatic output before manual adjustment.
- uAid: The reported performance metrics (sensitivity, specificity, processing time, memory usage) are direct measurements of the algorithm's output in categorizing image quality criteria. The system classifies images and presents the evaluation "instantly accessible to radiologic technologists," but the evaluation itself is algorithmic.
7. The Type of Ground Truth Used
uVision:
- The ground truth for uVision appears to be clinical technicians' criteria. The metric is "meet clinical technicians' criteria with 95% compliance," implying that the "correct" positioning is defined by the standards and expectations of experienced technicians.
uAid:
- The ground truth for uAid's image quality classification is based on established clinical quality control criteria for chest X-rays. The acceptance criteria explicitly reference "mature industry guidelines and standards, such as those from European Radiology and the ACR-AAPM-SPR Practice Parameter." This suggests an expert consensus-driven or guideline-based ground truth for what constitutes a "Grade A" image or the presence of specific issues like foreign objects or incomplete lung fields.
8. The Sample Size for the Training Set
uVision:
- The sample size for the training set for uVision is not provided. The document explicitly states that the "testing dataset was collected independently from the training dataset, with separated subjects and during different time periods."
uAid:
- The sample size for the training set for uAid is not provided. It is mentioned that "The data collection started in October 2017... from different cooperative hospitals" for the overall data reservoir, but specific numbers for training versus testing are not given. Similar to uVision, the testing data is stated to be "entirely independent and does not share any overlap with the training data."
9. How the Ground Truth for the Training Set Was Established
uVision:
- The method for establishing the ground truth for the training set for uVision is not provided.
uAid:
- The method for establishing the ground truth for the training set for uAid is not provided. While the testing set's ground truth is implied to be based on industry guidelines and clinical criteria, the process for prospectively labeling training data is not detailed.
Ask a specific question about this device
(57 days)
The uMR 680 system is indicated for use as a magnetic resonance diagnostic device (MRDD) that produces sagittal, transverse, coronal, and oblique cross sectional images, and spectroscopic images, and that display internal anatomical structure and/or function of the head, body and extremities.
These images and the physical parameters derived from the images when interpreted by a trained physician yield information that may assist the diagnosis. Contrast agents may be used depending on the region of interest of the scan.
The uMR 680 is a 1.5T superconducting magnetic resonance diagnostic device with a 70cm size patient bore. It consists of components such as magnet, RF power amplifier, RF coils, gradient power amplifier, gradient coils, patient table, spectrometer, computer, equipment cabinets, power distribution system, internal communication system, and vital signal module etc. The uMR 680 Magnetic Resonance Diagnostic Device is designed to conform to NEMA and DICOM standards.
This special 510(k) is to request modifications for the cleared uMR 680(K243397). The modifications performed on the uMR 680 in this submission are due to the following changes that include:
(1) Addition of RF coils: Tx/Rx Head Coil.
(2) Addition of a mobile configuration.
N/A
Ask a specific question about this device
(257 days)
The uWS-Angio Pro is a post-processing software based on the uWS-Angio Basic for viewing, processing, evaluating and analyzing CT, MR, 3D XA images, and overlaying 2D medical images to support image guidance during interventional procedures. It has the following application:
The uWS-Angio Pro uTarget view application is intended to provide tools for adding the trajectory to the lesion. It also supports overlay of 3D datasets on 2D fluoroscopy images.
The uWS-Angio Pro uEmbo View application is intended to provide users with tools for planning and guiding interventional procedures. It offers a suite of features to mark targets, detect feeder vessels, and overlay the 3D image with the feeders and the corresponding anatomical X-ray image. When the overlay function is activated, it supports automatic 2D-3D image registration specifically for head neuroimaging, while the manual registration function is not restricted to any specific anatomical region.
The uWS-Angio Pro uCardiac View application is intended to provide users tools to plan and guide the interventional procedures. This application can use CT angiography images for vascular access analysis, aortic root analysis and angle management, and overlay registration display with 2D XA images.
uWS-Angio Pro is a software intended for viewing, processing, evaluating and analyzing medical images that comply with the DICOM 3.0 protocol. It supports interpretation and evaluation of examinations within healthcare institutions. It can be deployed on independent hardware such as a stand-alone diagnostic review and post-processing workstation. It can also be configured within a network to send and receive DICOM data. Furthermore, it can be deployed on systems of the United Imaging Healthcare Angiography system family.
uWS-Angio Pro contains the following applications:
- uWS-Angio Pro uTarget View
- uWS-Angio Pro uEmbo View
- uWS-Angio Pro uCardiac View
N/A
Ask a specific question about this device
(157 days)
uDR Aurora CX is intended to acquire X-ray images of the human body by a qualified technician, examples include acquiring two-dimensional X-ray images of the skull, spinal column, chest, abdomen, extremities, limbs and trunk. The visualization of such anatomical structures provide visual evidence to radiologists and clinicians in making diagnostic decisions. This device is not intended for mammography.
uDR Aurora CX is a model of Digital Medical X-ray Imaging System developed and manufactured by Shanghai United Imaging Healthcare Co., Ltd(UIH). It includes X-ray Generator, X-ray Imaging System. The X-ray Generator produces controlled X-rays by high-voltage generator and X-ray tube assembly, ensuring stable energy output for human body penetration. The X-ray Imaging System converts X-ray photons into electrical signals by detectors, and generates DICOM-standard images by workstation to reflecting density variations of human body.
This document describes the acceptance criteria and study details for two features of the uDR Aurora CX device: uVision and uAid.
1. Acceptance Criteria and Reported Device Performance
| Feature | Acceptance Criteria | Reported Device Performance |
|---|---|---|
| uVision | When users employ the uVision function for automatic positioning, the automatically set system position and field size will meet clinical technicians' criteria with 95% compliance. This demonstrates that uVision can effectively assist clinical technicians in positioning tasks, specifically by aiming to reduce retake rates attributed to incorrect positioning (which studies indicate can range from 9% to 28%). | In 95% of patient positioning processes, the light field and equipment position automatically set by uVision met clinical positioning and shooting requirements for chest PA, whole-spine, and whole-lower-limb stitching exams. In the remaining 5% of cases, manual adjustments by technicians were needed. |
| uAid | The accuracy of non-standard image recognition (specifically, the rate of "Grade A" images recognized) should meet a 90% pass rate, aligning with industry standards derived from guidelines like those from European Radiology and ACR-AAPM-SPR Practice Parameter (which indicate Grade A image rates between 80% and 90% in public hospitals). This demonstrates that uAid can effectively assist clinical technicians in managing standardized image quality. | Overall Performance: The uAid function can correctly identify four types of results (Foreign object, Incomplete lung fields, Unexposed shoulder blades, and Centerline deviation) and classify images into Green (qualified), Yellow (secondary), or Red (waste). It meets the requirement for checking examination and positioning quality. |
| Specific Metric/Quantitative Performance (from "Summary"):- Average algorithm time: 1.359 seconds (longest not exceeding 2 seconds).- Maximum memory occupation: Not more than 2G.- For foreign body, lung field integrity, and scapula opening, both sensitivity and specificity for recognition exceed 0.9. |
2. Sample Size and Data Provenance for the Test Set
| Feature | Sample Size for Test Set | Data Provenance |
|---|---|---|
| uVision | 348 cases (328 Chest PA cases + 20 Full Spine or Full Lower Limb Stitching cases) collected over one week from 2024.12.17 to 2024.12.23. The device had been installed for over a year, with an average daily volume of ~80 patients, ~45 chest X-rays/day, and ~10-20 stitching cases/week. | Prospective/Retrospective Hybrid: The data was collected prospectively from a device (serial number 11XT7E0001) in clinical use after installation and commissioning over a year prior to the reported test period. It was collected from individuals of all genders and varying heights (able to stand independently). The testing was conducted in a real-world clinical setting. Country of Origin: Not explicitly stated, but the company is in Shanghai, China, suggesting the data is likely from China. |
| uAid | Not explicitly stated as a single total number of cases. Instead, the data distribution is provided, indicating various counts for different conditions across gender and age groups. For example, "lung field segmentation" had 465 negative and 31 positive cases. "Foreign object" had 1078 negative and 3080 positive cases. The sum of these individual counts suggests a total dataset of several thousand images. | Retrospective: Data collection for uAid started in October 2017, with a wide range of data sources, including different cooperative hospitals. The data was cleaned and stored in DICOM format. Country of Origin: Not explicitly stated, but the company is in Shanghai, China, suggesting the data is likely from China. |
3. Number and Qualifications of Experts for Ground Truth (Test Set)
| Feature | Number of Experts | Qualifications of Experts |
|---|---|---|
| uVision | Not explicitly stated. The statement says, "The results automatically set by the system are then statistically analyzed by clinical experts." | "Clinical experts." No specific qualifications (e.g., years of experience, specialty) are provided. |
| uAid | Not explicitly stated. The document mentions "The study was approved by the institutional review board of the hospitals," which implies expert review but does not detail the number or roles of experts in establishing the ground truth labels for the specific image characteristics tested. | Not explicitly stated for establishing ground truth labels. |
4. Adjudication Method (Test Set)
| Feature | Adjudication Method |
|---|---|
| uVision | Not explicitly stated. The data was "statistically analyzed by clinical experts." It does not specify if multiple experts reviewed cases or how disagreements were resolved. |
| uAid | Not explicitly stated. The process mentions data cleaning and sorting, and IRB approval, but not the specific adjudication method for individual image labels. |
5. Multi-Reader Multi-Case (MRMC) Comparative Effectiveness Study
- uVision: No MRMC comparative effectiveness study was done to compare human readers with and without AI assistance. The study evaluates the AI's direct assistance in positioning, measured by compliance with clinical criteria, rather than comparing diagnostic performance of human readers.
- uAid: No MRMC comparative effectiveness study was done. The study focuses on the standalone performance of the algorithm in identifying image quality issues, not on how it impacts human reader diagnostic accuracy or efficiency.
6. Standalone Performance (Algorithm Only)
- uVision: Yes, a standalone performance study was done. The "95% compliance" rate refers to the algorithm's direct ability to set system position and FOV that meet clinical technician criteria without a human actively adjusting or guiding the initial AI-generated settings during the compliance evaluation. Technicians could manually adjust those settings if needed.
- uAid: Yes, a standalone performance study was done. The algorithm processes images and outputs a quality classification (Green, Yellow, Red) and identifies specific issues (foreign object, incomplete lung fields, etc.). Its sensitivity and specificity metrics are standalone performance indicators.
7. Type of Ground Truth Used
- uVision: Expert Consensus/Clinical Criteria: The ground truth for uVision's performance (i.e., whether the automatically set position/FOV was "compliant") was established by "clinical experts" based on "clinical technicians' criteria" for proper positioning and shooting requirements.
- uAid: Expert Consensus/Manual Labeling: The ground truth for uAid's evaluation (e.g., presence of foreign objects, complete lung fields, open scapula, centerline deviation) was established through a "classification" process, implying manual labeling or consensus by experts after data collection and cleaning. The document mentions "negative" and "positive" data distributions for each criterion.
8. Sample Size for the Training Set
- uVision: Not explicitly stated in the provided text. The testing data was confirmed to be "collected independently from the training dataset, with separated subjects and during different time periods."
- uAid: Not explicitly stated in the provided text. The document mentions "The data collection started in October 2017, with a wide range of data sources" for training, but does not provide specific numbers for the training set size.
9. How Ground Truth for Training Set was Established
- uVision: Not explicitly stated for the training set. It can be inferred that a similar process to the test set, involving expert review against clinical criteria, would have been used.
- uAid: Not explicitly stated for the training set. Given that the data was collected from "different cooperative hospitals," "multiple cleaning and sorting" was performed, and the study was "approved by the institutional review board," it is highly likely that the ground truth for the training set involved manual labeling by clinical experts/radiologists, followed by a review process (potentially consensus-based or single-expert) to establish the labels for image characteristics and quality.
Ask a specific question about this device
(247 days)
uWS-Angio is a post-processing software based on the uWS-Angio Basic for viewing, processing, evaluating and analyzing XA images. It has the following application:
-
The uWS-Angio 2D Vessel Analysis is intended to provide users a tool for quantifying the dimensions of coronary and peripheral vessels from 2D angiographic images. It supports vessel segmentation and output associated diameter parameters and curves.
-
The uWS-Angio Left Ventricular Analysis application is intended to provide users a tool for analyzing left ventricular functions. It supports editing contours of ventricular and outputs a set of parameters to show the ventricular functions and wall motion.
-
The uWS-Angio 2D Blood Flow Analysis application is intended to provide users a tool for analyzing blood flow of region of interest in peripheral vessels. It supports adding interest region and output multiple blood flow parameters for further perfusion analysis.
-
The uWS-Angio Stitching is intended to provide users a tool for lower extremities stitching bolus-chase acquired images into a stitching image.
uWS-Angio is a post-processing software intended for viewing, processing, evaluating, and analyzing medical images that comply with the DICOM 3.0 protocol. It supports interpretation and evaluation of examinations within healthcare institutions. It can be deployed on independent hardware such as a stand-alone diagnostic review and post-processing workstation. It can also be configured within a network to send and receive DICOM data. Furthermore, it can be deployed on systems of the United Imaging Healthcare Angiography system family.
uWS-Angio contains the following applications:
- uWS-Angio 2D Vessel Analysis
- uWS-Angio Left Ventricular Analysis
- uWS-Angio 2D Blood Flow Analysis
- uWS-Angio Stitching
N/A
Ask a specific question about this device
(190 days)
The uMR Jupiter system is indicated for use as a magnetic resonance diagnostic device (MRDD) that produces sagittal, transverse, coronal, and oblique cross sectional images, and spectroscopic images, and that display internal anatomical structure and/or function of the head, body and extremities.
These images and the physical parameters derived from the images when interpreted by a trained physician yield information that may assist the diagnosis. Contrast agents may be used depending on the region of interest of the scan.
The device is intended for patients > 20 kg/44 lbs.
uMR Jupiter is a 5T superconducting magnetic resonance diagnostic device with a 60cm size patient bore and 8 channel RF transmit system. It consists of components such as magnet, RF power amplifier, RF coils, gradient power amplifier, gradient coils, patient table, spectrometer, computer, equipment cabinets, power distribution system, internal communication system, and vital signal module etc. uMR Jupiter is designed to conform to NEMA and DICOM standards.
The modification performed on the uMR Jupiter in this submission is due to the following changes that include:
-
Addition of RF coils: SuperFlex Large - 24 and Foot & Ankle Coil - 24.
-
Addition of applied body part for certain coil: SuperFlex Small-24 (add imaging of ankle).
-
Addition and modification of pulse sequences:
- a) New sequences: fse_wfi, gre_fsp_c (3D), gre_bssfp_ucs, epi_fid(3D), epi_dti_msh.
- b) Added Associated options for certain sequences: asl_3d (add mPLD) (Only output original images and no quantification images are output), gre_fsp_c (add Cardiac Cine, Cardiac Perfusion, PSIR, Cardiac mapping), gre_quick(add WFI, MRCA), gre_bssfp(add Cardiac Cine, Cardiac mapping), epi_dwi(add IVIM) (Only output original images and no quantification images are output).
-
Addition of function: EasyScan, EasyCrop, t-ACS, QScan, tFAST, DeepRecon and WFI.
-
Addition of workflow: EasyFACT.
This FDA 510(k) summary (K250246) for the uMR Jupiter provides details on several new AI-assisted features. Here's a breakdown of the acceptance criteria and the study that proves the device meets them, based on the provided text:
Important Note: The document is not a MRMC study comparing human readers with and without AI. Instead, it focuses on the performance of individual AI modules and their integration into the MRI system, often verified by radiologists' review of image quality.
Acceptance Criteria and Reported Device Performance
The document presents acceptance criteria implicitly through the "Test Result" or "Performance Verification" sections for each AI feature. The "Performance" column below summarizes the device's reported achievement for these criteria.
| Feature | Acceptance Criteria (Implicit) | Reported Device Performance |
|---|---|---|
| WFI | Expected to produce diagnostic quality images and effectively overcome water-fat swap artifacts, providing accurate initialization for the RIPE algorithm. Modes (default, standard, fast) should meet clinical diagnosis requirements. | "Based on the clinical evaluation of this independent testing dataset by three U.S. certificated radiologists, all three WFI modes meet the requirements for clinical diagnosis. In summary, the WFI performed as intended and passed all performance evaluations." |
| t-ACS | AI Module Test: AI prediction output should be much closer to the reference compared to the AI module input images. Integration Test: Better consistency between t-ACS and reference than CS and reference; no large structural differences; motion-time curves and Bland-Altman analysis showing consistency. | AI Module Test: "AI prediction (AI module output) was much closer to the reference comparing to the AI module input images in all t-ACS application types." Integration Test: 1. "A better consistency between t-ACS and the reference than that between CS and the reference was shown in all t-ACS application types." 2. "No large structural difference appeared between t-ACS and the reference in all t-ACS application types." 3. "The motion-time curves and Bland-Altman analysis showed the consistency between t-ACS and the reference based on simulated and real acquired data in all t-ACS application types." Overall: "The t-ACS on uMR Jupiter was shown to perform better than traditional Compressed Sensing in the sense of discrepancy from fully sampled images and PSNR using images from various age groups, BMIs, ethnicities and pathological variations. The structure measurements on paired images verified that same structures of t-ACS and reference were significantly the same. And t-ACS integration tests in two applications proved that t-ACS had good agreement with the reference." |
| DeepRecon | Expected to provide image de-noising and super-resolution, resulting in diagnostic quality images, with equivalent or higher scores than reference images in terms of diagnostic quality. | "The DeepRecon has been validated to provide image de-nosing and super-resolution processing using various ethnicities, age groups, BMIs, and pathological variations. In addition, DeepRecon images were evaluated by American Board of Radiologists certificated physicians, covering a range of protocols and body parts. The evaluation reports from radiologists verified that DeepRecon meets the requirements of clinical diagnosis. All DeepRecon images were rated with equivalent or higher scores in terms of diagnosis quality." |
| EasyFACT | Expected to effectively automate ROI placement and numerical statistics for FF and R2* values, with results subjectively evaluated as effective. | "The subjective evaluation method was used [to verify effectiveness]." "The proposal of algorithm acceptance criteria and score processing are conducted by the licensed physicians with U.S. credentials." (Implied successful verification from context) |
| EasyScan | Pass criteria of 99.3% for automatic slice group positioning, meeting safety and effectiveness requirements. | "The pass criteria of EasyScan feature is 99.3%, and the results evaluated by the licenced MRI technologist with U.S. credentials. Therefore, EasyScan meets the criteria for safety and effectiveness, and EasyScan can meet the requirements for automatic positioning locates slice groups." (Implied reaching or exceeding 99.3%.) |
| EasyCrop | Pass criteria of 100% for automatic image cropping, meeting safety and effectiveness requirements. | "The pass criteria of EasyCrop feature is 100%, and the results evaluated by the licenced MRI technologist with U.S. credentials. Therefore, EasCrop meets the criteria for safety and effectiveness, and EasCrop can meet the requirements for automatic cropping." (Implied reaching or exceeding 100%.) |
Study Details
-
Sample sizes used for the test set and the data provenance:
- WFI: 144 cases from 28 volunteers. Data collected from UIH Jupiter. "Completely separated from the previous mentioned training dataset by collecting from different volunteers and during different time periods." (Retrospective for testing, though specific country of origin beyond "UIH MRI systems" is not explicitly stated for testing data, training data has "Asian" majority.)
- t-ACS: 35 subjects (data from 76 volunteers used for overall training/validation/test split). Test data collected independently from the training data, with separated subjects and during different time periods. "White," "Black," and "Asian" ethnicities mentioned, implying potentially multi-country or diverse internal dataset.
- DeepRecon: 20 subjects (2216 cases). "Diverse demographic distributions" including "White" and "Asian" ethnicities. "Collecting testing data from various clinical sites and during separated time periods."
- EasyFACT: 5 subjects. "Data were acquired from 5T magnetic resonance imaging equipment from UIH," and "Asia" ethnicity is listed.
- EasyScan: 30 cases from 18 "Asia" subjects (initial testing); 40 cases from 8 "Asia" subjects (validation on uMR Jupiter system).
- EasyCrop: 5 subjects. "Data were acquired from 5T magnetic resonance imaging equipment from UIH," and "Asia" ethnicity is listed.
Data provenance isn't definitively "retrospective" or "prospective" for the test sets, but the emphasis on "completely separated" and "independent" from training data collected at "different time periods" suggests these were distinct, potentially newly acquired or curated sets for evaluation. The presence of multiple ethnicities (White, Black, Asian) suggests potentially broader geographical origins than just China where the company is based, or a focus on creating diverse internal datasets.
-
Number of experts used to establish the ground truth for the test set and the qualifications of those experts:
- WFI: Three U.S. certificated radiologists. (Qualifications: U.S. board-certified radiologists).
- t-ACS: No separate experts establishing ground truth for the test set performance evaluation are mentioned beyond the quantitative metrics (MAE, PSNR, SSIM) compared against "fully sampled images" (reference/ground truth). The document states that fully-sampled k-space data transformed into image domain served as the reference.
- DeepRecon: American Board of Radiologists certificated physicians. (Qualifications: American Board of Radiologists certificated physicians).
- EasyFACT: Licensed physicians with U.S. credentials. (Qualifications: Licensed physicians with U.S. credentials).
- EasyScan: Licensed MRI technologist with U.S. credentials. (Qualifications: Licensed MRI technologist with U.S. credentials).
- EasyCrop: Licensed MRI technologist with U.S. credentials. (Qualifications: Licensed MRI technologist with U.S. credentials).
-
Adjudication method (e.g. 2+1, 3+1, none) for the test set:
The document does not explicitly state an adjudication method (like 2+1 or 3+1) for conflict resolution among readers. For WFI, DeepRecon, EasyFACT, EasyScan, and EasyCrop, it implies a consensus or majority opinion model based on the "evaluation reports from radiologists/technologists." For t-ACS, the evaluation of the algorithm's output is based on quantitative metrics against a reference image ground truth.
-
If a multi-reader multi-case (MRMC) comparative effectiveness study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance:
No, a traditional MRMC comparative effectiveness study where human readers interpret cases with AI assistance versus without AI assistance was not described. The studies primarily validated the AI features' standalone performance (e.g., image quality, accuracy of automated functions) or their output's equivalence/superiority to traditional methods, often through expert review of the AI-generated images. Therefore, no effect size of human reader improvement with AI assistance is provided.
-
If a standalone (i.e. algorithm only without human-in-the-loop performance) was done:
Yes, standalone performance was the primary focus for most AI features mentioned, though the output was often subject to human expert review.
- WFI: The AI network provides initialization for the RIPE algorithm. The output image quality was then reviewed by radiologists.
- t-ACS: Performance was evaluated quantitatively against fully sampled images (reference/ground truth), indicating a standalone algorithm evaluation.
- DeepRecon: Evaluated based on images processed by the algorithm, with expert review of the output images.
- EasyFACT, EasyScan, EasyCrop: These are features that automate parts of the workflow. Their output (e.g., ROI placement, slice positioning, cropping) was evaluated, often subjectively by experts, but the automation itself is algorithm-driven.
-
The type of ground truth used (expert consensus, pathology, outcomes data, etc.):
- WFI: Expert consensus/review by three U.S. certificated radiologists for "clinical diagnosis" quality. No "ground truth" for water-fat separation accuracy itself is explicitly stated, but the problem being solved (water-fat swap artifacts) implies the improved stability of the algorithm's output.
- t-ACS: "Fully-sampled k-space data were collected and transformed into image domain as reference." This serves as the "true" or ideal image for comparison, not derived from expert interpretation or pathology.
- DeepRecon: "Multiple-averaged images with high-resolution and high SNR were collected as the ground-truth images." Expert review confirms diagnostic quality of processed images.
- EasyFACT: Subjective evaluation by licensed physicians with U.S. credentials, implying their judgment regarding the correctness of ROI placement and numerical statistics.
- EasyScan: Evaluation by a licensed MRI technologist with U.S. credentials against the "correctness" of automatic slice positioning.
- EasyCrop: Evaluation by a licensed MRI technologist with U.S. credentials against the "correctness" of automatic cropping.
-
The sample size for the training set:
- WFI AI module: 59 volunteers (2604 cases). Each scanned for multiple body parts and WFI protocols.
- t-ACS AI module: Not specified as a distinct number, but "collected from a variety of anatomies, image contrasts, and acceleration factors... resulting in a large number of cases." The overall dataset for training, validation, and testing was 76 volunteers.
- DeepRecon: 317 volunteers.
- EasyFACT, EasyScan, EasyCrop: "The training data used for the training of the EasyFACT algorithm is independent of the data used to test the algorithm." For EasyScan and EasyCrop, it states "The testing dataset was collected independently from the training dataset," but does not provide specific training set sizes for these workflow features.
-
How the ground truth for the training set was established:
- WFI AI module: The AI network was trained to provide accurate initialization for the RIPE algorithm. The document implies that the RIPE algorithm itself with human oversight or internal validation would have been used to establish correct water/fat separation for training.
- t-ACS AI module: "Fully-sampled k-space data were collected and transformed into image domain as reference." This served as the ground truth against which the AI was trained to reconstruct undersampled data.
- DeepRecon: "The multiple-averaged images with high-resolution and high SNR were collected as the ground-truth images." This indicates that high-quality, non-denoised, non-super-resolved images were used as the ideal target for the AI.
- EasyFACT, EasyScan, EasyCrop: Not explicitly detailed beyond stating that training data ground truth was established to enable the algorithms for automatic ROI placement, slice group positioning, and image cropping, respectively. It implies a process of manually annotating or identifying the correct ROIs/positions/crops on training data for the AI to learn from.
Ask a specific question about this device
(31 days)
The uMI Panvivo is a PET/CT system designed for providing anatomical and functional images. The PET provides the distribution of specific radiopharmaceuticals. CT provides diagnostic tomographic anatomical information as well as photon attenuation information for the scanned region. PET and CT scans can be performed separately. The system is intended for assessing metabolic (molecular) and physiologic functions in various parts of the body. When used with radiopharmaceuticals approved by the regulatory authority in the country of use, the uMI Panvivo system generates images depicting the distribution of these radiopharmaceuticals. The images produced by the uMI Panvivo are intended for analysis and interpretation by qualified medical professionals. They can serve as an aid in detection, localization, evaluation, diagnosis, staging, re-staging, monitoring, and/or follow-up of abnormalities, lesions, tumors, inflammation, infection, organ function, disorders, and/or diseases, in several clinical areas such as oncology, cardiology, neurology, infection and inflammation. The images produced by the system can also be used by the physician to aid in radiotherapy treatment planning and interventional radiology procedures.
The CT system can be used for low dose CT lung cancer screening for the early detection of lung nodules that may represent cancer. The screening must be performed within the established inclusion criteria of programs / protocols that have been approved and published by either a governmental body or professional medical society.
The proposed device uMI Panvivo combines a 295/235 mm axial field of view (FOV) PET and 160-slice CT system to provide high quality functional and anatomical images, fast PET/CT imaging and better patient experience. The system includes PET system, CT system, patient table, power distribution unit, control and reconstruction system (host, monitor, and reconstruction computer, system software, reconstruction software), vital signal module and other accessories.
The uMI Panvivo has been previously cleared by FDA via K243538. The main modifications performed on the uMI Panvivo (K243538) in this submission are due to the addition of Deep MAC(also named AI MAC), Digital Gating(also named Self-gating), OncoFocus(also named uExcel Focus and RMC), NeuroFocus(also named HMC), DeepRecon.PET (also named as HYPER DLR or DLR), uExcel DPR (also named HYPER DPR or HYPER AiR)and uKinetics. Details about the modifications are listed as below:
-
Deep MAC, Deep Learning-based Metal Artifact Correction (also named AI MAC) is an image reconstruction algorithm that combines physical beam hardening correction and deep learning technology. It is intended to correct the artifact caused by metal implants and external metal objects.
-
Digital Gating (also named Self-gating, cleared via K232712) can automatically extract a respiratory motion signal from the list-mode data during acquisition which called data-driven (DD) method. The respiratory motion signal was calculated by tracking the location of center-of-distribution(COD) in body cavity mask. By using the respiratory motion signal, system can perform gate reconstruction without respiratory capture device.
-
OncoFocus (also named uExcel Focus and RMC, cleared via K232712) is an AI-based algorithm to reduce respiratory motion artifacts in PET/CT images and at the same time reduce the PET/CT misalignment.
-
NeuroFocus (also named HMC) is head motion correction solution, which employs a statistics-based head motion correction method that correct motion artifacts automatically using the centroid-of-distribution (COD) without manual parameter tuning to generate motion free images.
-
DeepRecon.PET (also named as HYPER DLR or DLR, cleared via K193210) uses a deep learning technique to produce better SNR (signal-to-noise-ratio) image in post-processing procedure.
-
uExcel DPR (also named HYPER DPR or HYPER AiR, cleared via K232712) is a deep learning-based PET reconstruction algorithm designed to enhance the SNR of reconstructed images. High-SNR images improve clinical diagnostic efficacy, particularly under low-count acquisition conditions (e.g., low-dose radiotracer administration or fast scanning protocols).
-
uKinetics(cleared via K232712) is a kinetic modeling toolkit for indirect dynamic image parametric analysis and direct parametric analysis of multipass dynamic data. Image-derived input function (IDIF) can be extracted from anatomical CT images and dynamic PET images. Both IDIF and populated based input function (PBIF) can be used as input function of Patlak model to generate kinetic images which reveal biodistribution map of the metabolized molecule using indirect and direct methods.
The provided FDA 510(k) clearance letter describes the uMI Panvivo PET/CT System and mentions several new software functionalities (Deep MAC, Digital Gating, OncoFocus, NeuroFocus, DeepRecon.PET, uExcel DPR, and uKinetics). The document includes performance data for four of these functionalities: DeepRecon.PET, uExcel DPR, OncoFocus, and DeepMAC.
The following analysis focuses on the acceptance criteria and study details for these four AI-based image processing/reconstruction algorithms as detailed in the document. The document presents these as "performance verification" studies.
Overview of Acceptance Criteria and Device Performance (for DeepRecon.PET, uExcel DPR, OncoFocus, DeepMAC)
The document details the evaluation of four specific software functionalities: DeepRecon.PET, uExcel DPR, OncoFocus, and DeepMAC. Each of these has its own set of acceptance criteria and reported performance results, detailed below.
1. Table of Acceptance Criteria and Reported Device Performance
| Software Functionality | Evaluation Item | Evaluation Method | Acceptance Criteria | Reported Performance |
|---|---|---|---|---|
| DeepRecon.PET | Image consistency | Measuring mean SUV of phantom background and liver ROIs (regions of interest) and calculating bias. Used to evaluate image bias. | The bias is less than 5%. | Pass |
| Image background noise | a) Background variation (BV) in the IQ phantom.b) Liver and white matter signal-to-noise ratio (SNR) in the patient case. Used to evaluate noise reduction performance. | DeepRecon.PET has lower BV and higher SNR than OSEM with Gaussian filtering. | Pass | |
| Image contrast to noise ratio | a) Contrast to noise ratio (CNR) of the hot spheres in the IQ phantom.b) Contrast to noise ratio of lesions. CNR is a measure of the signal level in the presence of noise. Used to evaluate lesion detectability. | DeepRecon.PET has higher CNR than OSEM with Gaussian filtering. | Pass | |
| uExcel DPR | Quantitative evaluation | Contrast recovery (CR), background variability (BV), and contrast-to-noise ratio (CNR) calculated using NEMA IQ phantom data reconstructed with uExcel DPR and OSEM methods under acquisition conditions of 1 to 5 minutes per bed.Coefficient of Variation (COV) calculated using uniform cylindrical phantom data on images reconstructed with both uExcel DPR and OSEM methods. | The averaged CR, BV, and CNR of the uExcel DPR images should be superior to those of the OSEM images.uExcel DPR requires fewer counts to achieve a matched COV compared to OSEM. | Pass.- NEMA IQ Phantom Analysis: an average noise reduction of 81% and an average SNR enhancement of 391% were observed.- Uniform cylindrical Analysis: 1/10 of the counts can obtain the matching noise level. |
| Qualitative evaluation | uExcel DPR images reconstructed at lower counts qualitatively compared with full-count OSEM images. | uExcel DPR reconstructions with reduced count levels demonstrate comparable or superior image quality relative to higher-count OSEM reconstructions. | Pass.- 1.7 | |
| OncoFocus | Volume relative to no motion correction (∆Volume). | Calculate the volume relative to no motion correction images. | The ∆Volume value is less than 0%. | Pass |
| Maximal standardized uptake value relative to no motion correction (∆SUVmax) | Calculate the SUVmax relative to no motion correction images. | The ∆SUVmax value is larger than 0%. | Pass | |
| DeepMAC | Quantitative evaluation | For PMMA phantom data, the average CT value in the affected area of the metal substance and the same area of the control image before and after DeepMAC was compared. | After using DeepMAC, the difference between the average CT value in the affected area of the metal substance and the same area of the control image does not exceed 10HU. | Pass |
2. Sample Sizes Used for the Test Set and Data Provenance
-
DeepRecon.PET:
- Phantoms: NEMA IQ phantoms.
- Clinical Patients: 20 volunteers.
- Data Provenance: "collected from various clinical sites" and explicitly stated to be "different from the training data." The document does not specify country of origin or if it's retrospective/prospective, but "volunteers were enrolled" suggests prospective collection for the test set.
-
uExcel DPR:
- Phantoms: Two NEMA IQ phantom datasets, two uniform cylindrical phantom datasets.
- Clinical Patients: 19 human subjects.
- Data Provenance: "derived from uMI Panvivo and uMI Panvivo S," "collected from various clinical sites and during separated time periods," and "different from the training data." "Study cohort" and "human subjects" imply prospective collection for the test set.
-
OncoFocus:
- Clinical Patients: 50 volunteers.
- Data Provenance: "collected from general clinical scenarios" and explicitly stated to be "on cases different from the training data." "Volunteers were enrolled" suggests prospective collection for the test set.
-
DeepMAC:
- Phantoms: PMMA phantom datasets.
- Clinical Patients: 20 human subjects.
- Data Provenance: "from uMI Panvivo and uMI Panvivo S," "collected from various clinical sites" and explicitly stated to be "different from the training data." "Volunteers were enrolled" suggests prospective collection for the test set.
3. Number of Experts Used to Establish the Ground Truth for the Test Set and Qualifications of Those Experts
The document does not explicitly state that experts established "ground truth" for the quantitative metrics (e.g., SUV, CNR, BV, CR, ∆Volume, ∆SUVmax, HU differences) for the test sets. These seem to be derived from physical measurements on phantoms or calculations from patient image data using established methods.
-
For qualitative evaluation/clinical diagnosis assessment:
- DeepRecon.PET: Two American Board of Radiologists certified physicians.
- uExcel DPR: Two American board-certified nuclear medicine physicians.
- OncoFocus: Two American Board of Radiologists-certified physicians.
- DeepMAC: Two American Board of Radiologists certified physicians.
The exact years of experience for these experts are not provided, only their board certification status.
4. Adjudication Method for the Test Set
The document states that the radiologists/physicians evaluated images "independently" (uExcel DPR) or simply "were evaluated by" (DeepRecon.PET, OncoFocus, DeepMAC). There is no mention of an adjudication method (such as 2+1 or 3+1 consensus) for discrepancies between reader evaluations for any of the functionalities. The evaluations appear to be separate assessments, with no stated consensus mechanism.
5. If a Multi-Reader Multi-Case (MRMC) Comparative Effectiveness Study Was Done, and the Effect Size of How Much Human Readers Improve with AI vs. Without AI Assistance
- The document describes qualitative evaluations by radiologists/physicians comparing the AI-processed images to conventionally processed images (OSEM/no motion correction/no MAC). These are MRMC comparative studies in the sense that multiple readers evaluated multiple cases.
- However, these studies were designed to evaluate the image quality (e.g., diagnostic sufficiency, noise, contrast, sharpness, lesion detectability, artifact reduction) of the AI-processed images compared to baseline images, rather than to measure an improvement in human reader performance (e.g., diagnostic accuracy, sensitivity, specificity, reading time) when assisted by AI vs. without AI.
- Therefore, the studies were not designed as comparative effectiveness studies measuring the effect size of human reader improvement with AI assistance. They focus on the perceived quality of the AI-processed images themselves.
6. If a Standalone (i.e., algorithm only without human-in-the-loop performance) Was Done
- Yes, for DeepRecon.PET, uExcel DPR, OncoFocus, and DeepMAC, quantitative (phantom and numerical) evaluations were conducted that represent the standalone performance of the algorithms in terms of image metrics (e.g., SUV bias, BV, SNR, CNR, CR, COV, ∆Volume, ∆SUVmax, HU differences). These quantitative results are directly attributed to the algorithm's output without human intervention for the measurement/calculation.
- The qualitative evaluations by the physicians (described in point 3 above) also assess the output of the algorithm, but with human interpretation.
7. The Type of Ground Truth Used
-
For Quantitative Evaluations:
- Phantoms: The "ground truth" for phantom studies is implicitly the known physical properties and geometry of the NEMA IQ and PMMA phantoms, allowing for quantitative measurements (e.g., true SUV, true CR, true signal-to-noise).
- Clinical Data (DeepRecon.PET, uExcel DPR): For these reconstruction algorithms, "ground-truth images were reconstructed from fully-sampled raw data" for the training set. For the test set, comparisons seem to be made against OSEM with Gaussian filtering or full-count OSEM images as reference/comparison points, rather than an independent "ground truth" established by an external standard.
- Clinical Data (OncoFocus): Comparisons are made relative to "no motion correction images" (∆Volume and ∆SUVmax), implying these are the baseline for comparison, not necessarily an absolute ground truth.
- Clinical Data (DeepMAC): Comparisons are made to a "control image" without metal artifacts for quantitative assessment of HU differences.
-
For Qualitative Evaluations:
- The "ground truth" is based on the expert consensus / qualitative assessment by the American Board-certified radiologists/nuclear medicine physicians, who compared images for attributes like noise, contrast, sharpness, motion artifact reduction, and diagnostic sufficiency. This suggests a form of expert consensus, although no specific adjudication is described. There's no mention of pathology or outcomes data as ground truth.
8. The Sample Size for the Training Set
The document provides the following for the training sets:
- DeepRecon.PET: "image samples with different tracers, covering a wide and diverse range of clinical scenarios." No specific number provided.
- uExcel DPR: "High statistical properties of the PET data acquired by the Long Axial Field-of-View (LAFOV) PET/CT system enable the model to better learn image features. Therefore, the training dataset for the AI module in the uExcel DPR system is derived from the uEXPLORER and uMI Panorama GS PET/CT systems." No specific number provided.
- OncoFocus: "The training dataset of the segmentation network (CNN-BC) and the mumap synthesis network (CNN-AC) in OncoFocus was collected from general clinical scenarios. Each subject was scanned by UIH PET/CT systems for clinical protocols. All the acquisitions ensure whole-body coverage." No specific number provided.
- DeepMAC: Not explicitly stated for the training set. Only validation dataset details are given.
9. How the Ground Truth for the Training Set Was Established
- DeepRecon.PET: "Ground-truth images were reconstructed from fully-sampled raw data. Training inputs were generated by reconstructing subsampled data at multiple down-sampling factors." This implies that the "ground truth" for training was derived from high-quality, fully-sampled (and likely high-dose) PET data.
- uExcel DPR: "Full-sampled data is used as the ground truth, while corresponding down-sampled data with varying down-sampling factors serves as the training input." Similar to DeepRecon.PET, high-quality, full-sampled data served as the ground truth.
- OncoFocus:
- For CNN-BC (body cavity segmentation network): "The input data of CNN-BC are CT-derived attenuation coefficient maps, and the target data of the network are body cavity region images." This suggests the target (ground truth) was pre-defined body cavity regions.
- For CNN-AC (attenuation map (umap) synthesis network): "The input data are non-attenuation-corrected (NAC) PET reconstruction images, and the target data of the network are the reference CT attenuation coefficient maps." The ground truth was "reference CT attenuation coefficient maps," likely derived from actual CT scans.
- DeepMAC: Not explicitly stated for the training set. The mention of pre-trained neural networks suggests an established training methodology, but the specific ground truth establishment is not detailed.
Ask a specific question about this device
(244 days)
The uMR Ultra system is indicated for use as a magnetic resonance diagnostic device (MRDD) that produces sagittal, transverse, coronal, and oblique cross sectional images, and spectroscopic images, and that display internal anatomical structure and/or function of the head, body and extremities. These images and the physical parameters derived from the images when interpreted by a trained physician yield information that may assist the diagnosis. Contrast agents may be used depending on the region of interest of the scan.
uMR Ultra is a 3T superconducting magnetic resonance diagnostic device with a 70cm size patient bore and 2 channel RF transmit system. It consists of components such as magnet, RF power amplifier, RF coils, gradient power amplifier, gradient coils, patient table, spectrometer, computer, equipment cabinets, power distribution system, internal communication system, and vital signal module etc. uMR Ultra is designed to conform to NEMA and DICOM standards.
Here's a breakdown of the acceptance criteria and study details for the uMR Ultra device, based on the provided FDA 510(k) clearance letter.
1. Table of Acceptance Criteria and Reported Device Performance
Given the nature of the document, which focuses on device clearance, multiple features are discussed. I will present the acceptance criteria and results for the AI-powered features, as these are the most relevant to the "AI performance" aspect.
Acceptance Criteria and Device Performance for AI-Enabled Features
| AI-Enabled Feature | Acceptance Criteria | Reported Device Performance |
|---|---|---|
| ACS | - Ratio of error: NRMSE(output)/NRMSE(input) is always less than 1. - ACS has higher SNR than CS. - ACS has higher (standard deviation (SD) / mean value(S)) values than CS. - Bland-Altman analysis of image intensities acquired using fully sampled and ACS shown with less than 1% bias and all sample points falls in the 95% confidence interval. - Measurement differences on ACS and fully sampled images of same structures under 5% is acceptable. - Radiologists rate all ACS images with equivalent or higher scores in terms of diagnosis quality. | - Pass - Pass - Pass - Pass - Pass - Verified that ACS meets the requirements of clinical diagnosis. All ACS images were rated with equivalent or higher scores in terms of diagnosis quality. |
| DeepRecon | - DeepRecon images achieve higher SNR compared to NADR images. - Uniformity difference between DeepRecon images and NADR images under 5%. - Intensity difference between DeepRecon images and NADR images under 5%. - Measurements on NADR and DeepRecon images of same structures, measurement difference under 5%. - Radiologists rate all DeepRecon images with equivalent or higher scores in terms of diagnosis quality. | - NADR: 343.63, DeepRecon: 496.15 (PASS) - 0.07% (PASS) - 0.2% (PASS) - 0% (PASS) - Verified that DeepRecon meets the requirements of clinical diagnosis. All DeepRecon images were rated with equivalent or higher scores in terms of diagnosis quality. |
| EasyScan | No Fail cases and auto position success rate P1/(P1+P2+F) exceeds 80%. (P1: Pass with auto positioning; P2: Pass with user adjustment; F: Fail) | 99.6% |
| t-ACS | - AI prediction (AI module output) much closer to reference compared to AI module input images. - Better consistency between t-ACS and reference than between CS and reference. - No large structural difference appeared between t-ACS and reference. - Motion-time curves and Bland-Altman analysis consistency between t-ACS and reference. | - Pass - Pass - Pass - Pass |
| AiCo | - AiCo images exhibit improved PSNR and SSIM compared to the originals. - No significant structural differences from the gold standard. - Radiologists confirm image quality is diagnostically acceptable, fewer motion artifacts, and greater benefits for clinical diagnosis. | - Pass - Pass - Confirmed. |
| SparkCo | - Average detection accuracy needs to be > 90%. - Average PSNR of spark-corrected images needs to be higher than spark images. - Spark artifacts need to be reduced or corrected after enabling SparkCo. | - 94% - 1.6 higher - Successfully corrected |
| ImageGuard | Success rate P/(P+F) exceeds 90%. (P: Pass if prompt appears for motion / no prompt for no motion; F: Fail if prompt doesn't appear for motion / prompt appears for no motion) | 100% |
| EasyCrop | No Fail cases and pass rate P1/(P1+P2+F) exceeds 90%. (P1: Other peripheral tissues cropped, meets user requirements; P2: Cropped images don't meet user requirements, but can be re-cropped; F: EasyCrop fails or original images not saved) | 100% |
| EasyFACT | Satisfied and Acceptable ratio (S+A)/(S+A+F) exceeds 95%. (S: All ROIs placed correctly; A: Fewer than five ROIs placed correctly; F: ROIs positioned incorrectly or none placed) | 100% |
| Auto TI Scout | Average frame difference between auto-calculated TI and gold standard is ≤ 1 frame, and maximum frame difference is ≤ 2 frames. | Average: 0.37-0.44 frames, Maximum: 1-2 frames (PASS) |
| Inline MOCO | Average Dice coefficient of the left ventricular myocardium after motion correction is > 0.87. | Cardiac Perfusion Images: 0.92 Cardiac Dark Blood Images: 0.96 |
| Inline ED/ES Phases Recognition | The average error between the phase indices calculated by the algorithm for the ED and ES of test data and the gold standard phase indices does not exceed 1 frame. | 0.13 frames |
| Inline ECV | No failure cases, satisfaction rate S/(S+A+F) > 95%. (S: Segmentation adheres to myocardial boundary, blood pool ROI correct; A: Small missing/redundant areas but blood pool ROI correct; F: Myocardial mask fails or blood pool ROI incorrect) | 100% |
| EasyRegister (Height Estimation) | PH5 (Percentage of height error within 5%); PH15 (Percentage of height error within 15%); MEAN_H (Average error of height). (Specific numerical criteria not explicitly stated beyond these metrics) | PH5: 92.4% PH15: 100% MEAN_H: 31.53mm |
| EasyRegister (Weight Estimation) | PW10 (Percentage of weight error within 10%); PW20 (Percentage of weight error within 20%); MEAN_W (Average error of weight). (Specific numerical criteria not explicitly stated beyond these metrics) | PW10: 68.64% PW20: 90.68% MEAN_W: 6.18kg |
| EasyBolus | No Fail cases and success rate P1+P2/(P1+P2+F) exceeds 100%. (P1: Monitoring point positioning meets user requirements, frame difference ≤ 1 frame; P2: Monitoring point positioning meets user requirements, frame difference = 2 frames; F: Auto position fails or frame difference > 2 frames) | P1: 80% P2: 20% Total Failure Rate: 0% Pass: 100% |
For the rest of the questions, I will consolidate the information where possible, as some aspects apply across multiple AI features.
2. Sample Sizes Used for the Test Set and Data Provenance
- ACS: 749 samples from 25 volunteers. Diverse demographic distributions covering various genders, age groups, ethnicity (White, Asian, Black), and BMI (Underweight, Healthy, Overweight/Obesity). Data collected from various clinical sites during separated time periods.
- DeepRecon: 25 volunteers (nearly 2200 samples). Diverse demographic distributions covering various genders, age groups, ethnicity (White, Asian, Black), and BMI. Data collected from various clinical sites during separated time periods.
- EasyScan: 444 cases from 116 subjects. Diverse demographic distributions covering various genders, age groups, and ethnicities. Data acquired from UIH MRI equipment (1.5T and 3T). Data provenance not explicitly stated (e.g., country of origin), but given the company location (China) and "U.S. credentials" for evaluators, it likely includes data from both. The document states "The testing dataset was collected independently from the training dataset".
- t-ACS: 1173 cases from 60 volunteers. Diverse demographic distributions covering various genders, age groups, ethnicities (White, Black, Asian) and BMI. Data acquired by uMR Ultra scanners. Data provenance not explicitly stated, but implies global standard testing.
- AiCo: 218 samples from 24 healthy volunteers. Diverse demographic distributions covering various genders, age groups, BMI (Under/healthy weight, Overweight/Obesity), and ethnicity (White, Black, Asian). Data provenance not explicitly stated.
- SparkCo: 59 cases from 15 patients for real-world spark raw data testing. Diverse demographic distributions including gender, age, BMI (Underweight, Healthy, Overweight, Obesity), and ethnicity (Asian, "N.A." for White, implying not tested as irrelevant). Data acquired by uMR 1.5T and uMR 3T scanners.
- ImageGuard: 191 cases from 80 subjects. Diverse demographic distributions covering various genders, age groups, and ethnicities (White, Black, Asian). Data acquired from UIH MRI equipment (1.5T and 3T).
- EasyCrop: Not explicitly stated as "subjects" vs. "cases," but tested on 5 intended imaging body parts. Sample size (N=65) implies 65 cases/scans, potentially from 65 distinct subjects or fewer if subjects had multiple scans. Diverse demographic distributions covering various genders, age groups, ethnicity (Asian, Black, White). Data acquired from UIH MRI equipment (1.5T and 3T).
- EasyFACT: 25 cases from 25 volunteers. Diverse demographic distributions covering various genders, age groups, weight, and ethnicity (Asian, White, Black).
- Auto TI Scout: 27 patients. Diverse demographic distributions covering various genders, age groups, ethnicity (Asian, White), and BMI. Data acquired from 1.5T and 3T scanners.
- Inline MOCO: Cardiac Perfusion Images: 105 cases from 60 patients. Cardiac Dark Blood Images: 182 cases from 33 patients. Diverse demographic distributions covering age, gender, ethnicity (Asian, White, Black, Hispanic), BMI, field strength, and disease conditions (Positive, Negative, Unknown).
- Inline ED/ES Phases Recognition: 95 cases from 56 volunteers, covering various genders, age groups, field strength, disease conditions (NOR, MINF, DCM, HCM, ARV), and ethnicity (Asian, White, Black).
- Inline ECV: 90 images from 28 patients. Diverse demographic distributions covering gender, age, BMI, field strength, ethnicity (Asian, White), and health status (Negative, Positive, Unknown).
- EasyRegister (Height/Weight Estimation): 118 cases from 63 patients. Diverse ethnic groups (Chinese, US, France, Germany).
- EasyBolus: 20 subjects. Diverse demographic distributions covering gender, age, field strength, and ethnicity (Asia).
Data Provenance (Retrospective/Prospective and Country of Origin):
The document states "The testing dataset was collected independently from the training dataset, with separated subjects and during different time periods." This implies a prospective collection for validation that is distinct from the training data. For ACS and DeepRecon, it explicitly mentions "US subjects" for some evaluations, but for many features, the specific country of origin for the test set is not explicitly stated beyond "diverse ethnic groups" or "Asian" which could be China (where the company is based) or other Asian populations. The use of "U.S. board-certified radiologists" and "licensed MRI technologist with U.S. credentials" for evaluation suggests the data is intended to be representative of, or directly includes, data relevant to the U.S. clinical context.
3. Number of Experts Used to Establish the Ground Truth for the Test Set and Qualifications
- ACS & DeepRecon: Evaluated by "American Board of Radiologists certificated physicians" (plural, implying multiple, at least 2). Not specified how many exactly, but strong qualifications.
- EasyScan, ImageGuard, EasyCrop, EasyBolus: Evaluated by "licensed MRI technologist with U.S. credentials." For EasyBolus, it specifies "certified professionals in the United States." Number not explicitly stated beyond "the" technologist/professionals, but implying multiple for robust evaluation.
- Inline MOCO & Inline ECV: Ground truth annotations done by a "well-trained annotator" and "finally, all ground truth was evaluated by three licensed physicians with U.S. credentials." This indicates a 3-expert consensus/adjudication.
- SparkCo: "One experienced evaluator" for subjective image quality improvement.
- For other features (t-ACS, EasyFACT, Auto TI Scout, Inline ED/ES Phases Recognition, EasyRegister), the ground truth seems to be based on physical measurements (for EasyRegister) or computational metrics (for t-ACS based on fully-sampled images, and for accuracy of ROI placement against defined standards), rather than human expert adjudication for ground truth.
4. Adjudication Method (e.g., 2+1, 3+1, none) for the Test Set
- Inline MOCO & Inline ECV: "Evaluated by three licensed physicians with U.S. credentials." This implies a 3-expert consensus method for ground truth establishment.
- ACS, DeepRecon, AiCo: "Evaluated by American Board of Radiologists certificated physicians" (plural). While not explicitly stated as 2+1 or 3+1, it suggests a multi-reader review, where consensus was likely reached for the reported diagnostic quality.
- SparkCo: "One experienced evaluator" was used for subjective evaluation, implying no formal multi-reader adjudication for this specific metric.
- For features like EasyScan, ImageGuard, EasyCrop, EasyBolus (evaluated by MRI technologists) and those relying on quantitative metrics against a reference (t-ACS, EasyFACT, Auto TI Scout, EasyRegister, Inline ED/ES Phases Recognition), the "ground truth" is either defined by the system's intended function (e.g., correct auto-positioning) or a mathematically derived reference, so a traditional human adjudication method is not applicable in the same way as for diagnostic image interpretation.
5. If a Multi-Reader Multi-Case (MRMC) Comparative Effectiveness Study was Done
The document does not explicitly state that a formal MRMC comparative effectiveness study was performed to quantify the effect size of how much human readers improve with AI vs. without AI assistance.
Instead, the evaluations for ACS, DeepRecon, and AiCo involve "American Board of Radiologists certificated physicians" who "verified that [AI feature] meets the requirements of clinical diagnosis. All [AI feature] images were rated with equivalent or higher scores in terms of diagnosis quality." For AiCo, they confirmed images "exhibit fewer motion artifacts and offer greater benefits for clinical diagnosis." This is a qualitative assessment of diagnostic quality by experts, but not a comparative effectiveness study in the sense of measuring reader accuracy or confidence change with AI assistance.
6. If a Standalone (i.e., algorithm only without human-in-the-loop performance) was Done
Yes, for many of the AI-enabled features, a standalone performance evaluation was conducted:
- ACS: Performance was evaluated by comparing quantitative metrics (NRMSE, SNR, Resolution, Contrast, Uniformity, Structure Measurement) against fully-sampled images or CS. This is a standalone evaluation.
- DeepRecon: Quantitative metrics (SNR, uniformity, contrast, structure measurement) were compared between DeepRecon and NADR (without DeepRecon) images. This is a standalone evaluation.
- t-ACS: Quantitative tests (MAE, PSNR, SSIM, structural measurements, motion-time curves) were performed comparing t-ACS and CS results against a reference. This is a standalone evaluation.
- AiCo: PSNR and SSIM values were quantitatively compared, and structural dimensions were assessed, between AiCo processed images and original/motionless reference images. This is a standalone evaluation.
- SparkCo: Spark detection accuracy was calculated, and PSNR of spark-corrected images was compared to original spark images. This is a standalone evaluation.
- Inline MOCO: Evaluated using Dice coefficient, a quantitative metric for segmentation accuracy. This is a standalone evaluation.
- Inline ED/ES Phases Recognition: Evaluated by quantifying the error between algorithm output and gold standard phase indices. This is a standalone evaluation.
- Inline ECV: Evaluated by quantitative scoring for segmentation accuracy (S, A, F criteria). This is a standalone evaluation.
- EasyRegister (Height/Weight): Evaluated by quantitative error metrics (PH5, PH15, MEAN_H; PW10, PW20, MEAN_W) against physical measurements. This is a standalone evaluation.
Features like EasyScan, ImageGuard, EasyCrop, and EasyBolus involve automated workflow assistance where the direct "diagnostic" outcome isn't solely from the algorithm, but the automated function's performance is evaluated in a standalone manner against defined success criteria.
7. The Type of Ground Truth Used
The type of ground truth varies depending on the specific AI feature:
- Reference/Fully-Sampled Data:
- ACS, DeepRecon, t-ACS, AiCo: Fully-sampled k-space data transformed to image space served as "ground-truth" for training and as a reference for quantitative performance metrics in testing. For AiCo, "motionless data" served as gold standard.
- SparkCo: Simulated spark artifacts generated from "spark-free raw data" provided ground truth for spark point locations in training.
- Expert Consensus/Subjective Evaluation:
- ACS, DeepRecon, AiCo: "American Board of Radiologists certificated physicians" provided qualitative assessment of diagnostic image quality ("equivalent or higher scores," "diagnostically acceptable," "fewer motion artifacts," "greater benefits for clinical diagnosis").
- EasyScan, ImageGuard, EasyCrop, EasyBolus: "Licensed MRI technologist with U.S. credentials" or "certified professionals in the United States" performed subjective evaluation against predefined success criteria for the workflow functionality.
- SparkCo: One experienced evaluator for subjective image quality improvement.
- Anatomical/Physiological Measurements / Defined Standards:
- EasyFACT: Defined criteria for ROI placement within liver parenchyma, avoiding borders/vascular structures.
- Auto TI Scout, Inline ED/ES Phases Recognition: Gold standard phase indices were presumably established by expert review or a reference method.
- Inline MOCO & Inline ECV: Ground truth for cardiac left ventricular myocardium segmentation was established by a "well-trained annotator" and "evaluated by three licensed physicians with U.S. credentials" (expert consensus based on anatomical boundaries).
- EasyRegister (Height/Weight Estimation): "Precisely measured height/weight value" using "physical examination standards."
8. The Sample Size for the Training Set
- ACS: 1,262,912 samples (collected from variety of anatomies, image contrasts, and acceleration factors, scanned by UIH MRI systems).
- DeepRecon: 165,837 samples (collected from 264 volunteers, scanned by UIH MRI systems for multiple body parts and clinical protocols).
- EasyScan: Training data collection not explicitly detailed in the same way as ACS/DeepRecon (refers to "collected independently from the training dataset").
- t-ACS: Datasets collected from 108 volunteers ("large number of samples").
- AiCo: 140,000 images collected from 114 volunteers across multiple body parts and clinical protocols.
- SparkCo: 24,866 spark slices generated from 61 cases collected from 10 volunteers.
- EasyFACT, Auto TI Scout, Inline MOCO, Inline ED/ES Phases Recognition, Inline ECV, EasyRegister, EasyBolus: The document states that training data was independent of testing data but does not provide specific sample sizes for the training datasets for these features.
9. How the Ground Truth for the Training Set was Established
- ACS, DeepRecon, t-ACS, AiCo: "Fully-sampled k-space data were collected and transformed to image space as the ground-truth." For DeepRecon specifically, "multiple-averaged images with high-resolution and high SNR were collected as the ground-truth images." For AiCo, "motionless data" served as gold standard. All training data were "manually quality controlled."
- SparkCo: "The training dataset... was generated by simulating spark artifacts from spark-free raw data... with the corresponding ground truth (i.e., the location of spark points)."
- Inline MOCO & Inline ECV: The document states "all ground truth was annotated by a well-trained annotator. The annotator used an interactive tool to observe the image, and then labeled the left ventricular myocardium in the image."
- For EasyScan, EasyFACT, Auto TI Scout, Inline ED/ES Phases Recognition, EasyRegister, and EasyBolus training ground truth establishment is not explicitly detailed, only that the testing data was independent of the training data. For EasyRegister, it implies physical measurements were the basis for ground truth.