Search Filters

Search Results

Found 15 results

510(k) Data Aggregation

    K Number
    K172393

    Validate with FDA (Live)

    Date Cleared
    2018-04-23

    (258 days)

    Product Code
    Regulation Number
    870.1220
    Age Range
    All
    Reference & Predicate Devices
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The Advisor HD Grid Mapping Catheter, Sensor Enabled, is indicated for multiple electrode electrophysiological mapping of cardiac structures in the heart, i.e., recording or stimulation only. This catheter is intended to obtain electrograms in the atrial and ventricular regions of the heart.

    Device Description

    The Advisor HD Grid Mapping Catheter, Sensor Enabled, is a sterile, singleuse, irrigated, high-density mapping catheter with a 7.5F shaft and an 8F distal shaft deflectable section. It is available in a D-F bi-directional curve model that is deflected using the actuator located on the catheter handle. The catheter working length is 110 cm. The device consists of a paddle-shaped distal tip with 16 electrodes, two distal shaft ring electrodes, two magnetic sensors, polymer braided shaft, handle, fluid lumen extension with a luer, and an electrical connector. The catheter also has an introducer tool intended to compress and guide the distal paddle into, and withdraw from, the hemostasis valve of an introducer sheath. The catheter is compatible with the EnSite Velocity and EnSite Precision Cardiac Mapping Systems and other accessories, including the connecting cable and commercially available irrigation pumps.

    AI/ML Overview

    The provided text describes the St. Jude Medical Advisor HD Grid Mapping Catheter, Sensor Enabled. It mentions several types of testing conducted to demonstrate substantial equivalence to predicate devices, including bench, in vivo, and biocompatibility testing. However, the document does NOT contain a study that establishes acceptance criteria and provides specific device performance data in the format requested.

    The document lists various performance characteristics that were tested (e.g., irrigation pressure, electrical resistance, magnetic resistance, and compliance to various ISO and ANSI/AAMI/IEC standards), as well as a "GLP safety study" and an "Accuracy study" as part of in vivo testing. It states that "The resulting evidence obtained from the design verification and validation testing did not raise new questions of safety and effectiveness, and demonstrates that the subject device is as safe and effective as the predicate devices."

    However, it does not provide the acceptance criteria for these tests, nor does it present the reported device performance against those criteria in a quantitative manner. Therefore, I cannot complete the table or answer most of the specific questions about the study design, sample sizes, ground truth establishment, or expert involvement, as this information is not present in the provided text.

    Based on the provided text, I can only state that an "Accuracy study" was performed as an in vivo test, but no details about its methodology, results, or how it proved the device met specific acceptance criteria are given.

    The information regarding acceptance criteria and a study proving their fulfillment is absent from the provided FDA 510(k) clearance letter and associated indications for use and device description.

    Ask a Question

    Ask a specific question about this device

    K Number
    K163407

    Validate with FDA (Live)

    Date Cleared
    2017-09-29

    (298 days)

    Product Code
    Regulation Number
    870.2800
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The Confirm Rx™ ICM is indicated for the monitoring and diagnostic evaluation of patients who experience unexplained symptoms such as: dizziness, palpitations, chest pain, syncope, and shortness of breath, as well as patients who are at risk for cardiac arrhythmias. It is also indicated for patients who have been previously diagnosed with atrial fibrillation or who are susceptible to developing atrial fibrillation.

    Device Description

    The St. Jude Medical Confirm Rx™ system consists of the following key features and components:

    • Confirm RxTM ICM Model DM3500 Implantable Device: The ICM is intended as a minimally invasive, implantable diagnostic monitoring device, with subcutaneous electrodes, looping memory, and automatic as well as patient-activated EGM storage capability, which help physicians monitor, diagnose, and document patients who are susceptible to cardiac arrhythmias. It is predicated on SJM Confirm™ DM2102 with a two-year longevity, MR conditional labeling, and identical sensing and detection algorithms as SJM Confirm™ DM2102, but with downsized hardware and Bluetooth communication.
    • Implant Tools: Model DM3520 incision tool and Model DM3510 insertion tool to implant the device subcutaneously.
    • Model 3111 Magnet (existing SJM donut magnet) facilitates faster startup of Bluetooth connection and provides user authentication (required for programmer sessions).
    • Clinician Programmer (Merlin PCS Programmer Model 3650): The Merlin PCS Programmer 3650 operates using Merlin PCS Model 3330 software and provides the means for the physician to program device parameters and retrieve diagnostic information from the device, including electrograms, heart rate history, episode duration and trend information.
    • myMerlin™ Patient App (Model APP1000 Android): The Patient App provides the means for the patient to activate EGM recording in the Confirm Rx™ device, with data pass-through functionality to enable physician follow-up via the Merlin.net Patient Care Network.
    • Remote Care/Clinician Portal (Merlin.net MN5000 Report Generator): The Merlin.net MN5000 system allows physicians to remotely monitor and diagnose patients' cardiac events.
    AI/ML Overview

    The provided text describes the Confirm Rx™ Insertable Cardiac Monitor (ICM) System, Model DM3500.

    Here's an analysis of the acceptance criteria and the studies mentioned:

    1. Table of Acceptance Criteria and Reported Device Performance:

    The document mentions that the Confirm Rx™ ICM leverages the existing market-cleared SJM Confirm™ (DM2102) algorithms and functionality. Therefore, the "acceptance criteria" for the detection algorithms are implicitly inherited from the predicate device. While specific numerical targets for metrics like sensitivity or specificity are not explicitly stated as acceptance criteria for the Confirm Rx™ ICM in this summary, the key performance aspects verified through testing are:

    Acceptance Criterion (Implicitly inherited/verified)Reported Device Performance
    R-wave detectionVerified via bench and animal testing.
    Device migrationVerified via bench and animal testing.
    Algorithms and FunctionalityIdentical to SJM Confirm™ DM2102, which previously met clinical testing requirements (IDE G080090).
    Intended Performance"The results of testing show that the Confirm Rx™ ICM performs as intended and is safe for its intended use."
    Safety and Effectiveness (overall)"The Confirm Rx™ ICM is substantially equivalent to the predicate devices in terms of technological characteristics, intended use, and performance."

    Important Note: The provided document is a 510(k) summary, which focuses on demonstrating substantial equivalence to predicate devices. It typically does not contain the detailed clinical study reports or comprehensive performance metrics that would be found in a full PMA application or a detailed peer-reviewed publication. The "acceptance criteria" here are therefore inferred from the context of substantial equivalence to a previously cleared device.

    2. Sample Size Used for the Test Set and Data Provenance:

    • Test Set Sample Size: The document does not explicitly state a specific sample size for a clinical test set used to evaluate the Confirm Rx™ ICM's diagnostic performance for arrhythmia detection. It states: "R-wave detection and device migration were verified via bench and animal testing for the Confirm Rx™ ICM DM3500." and "The Confirm Rx™ ICM leverages the existing market cleared SJM Confirm™ (DM2102) algorithms and functionality for which the clinical testing, performed on the SJM Confirm™ (DM2102) device per St. Jude Medical IDE G080090, is applicable and was not repeated."
    • Data Provenance: The document does not specify the country of origin for the data, but it refers to an IDE (Investigational Device Exemption) study (G080090) conducted for the predicate device, SJM Confirm™ (DM2102). IDE studies are typically prospective clinical trials.

    3. Number of Experts Used to Establish Ground Truth for the Test Set and Their Qualifications:

    • This information is not provided in the 510(k) summary for the Confirm Rx™ ICM. Since the clinical performance data is leveraged from the predicate device, the details about ground truth establishment would reside in the original IDE G080090 submission for the SJM Confirm™ (DM2102).

    4. Adjudication Method for the Test Set:

    • This information is not provided in the 510(k) summary. Details on adjudication methods would typically be found in the full clinical study report for the predicate device (IDE G080090).

    5. If a Multi-Reader Multi-Case (MRMC) Comparative Effectiveness Study was done, and the effect size of how much human readers improve with AI vs. without AI assistance:

    • No MRMC comparative effectiveness study is mentioned. The Confirm Rx™ ICM is an insertable cardiac monitor that automatically detects and records cardiac events. It is not an AI-assisted diagnostic tool designed to improve human reader performance in interpreting medical images or complex waveforms. Its primary function is automated detection and recording, with physician review of the recorded electrograms (EGMs).

    6. If a Standalone (i.e., algorithm only without human-in-the-loop performance) was done:

    • Yes, the document implies standalone performance evaluation of the detection algorithms. It states that the Confirm Rx™ ICM utilizes "identical sensing and detection algorithms as SJM Confirm™ DM2102." These algorithms are designed for automated triggering of EGM storage based on detected events like tachycardia, pauses, and atrial fibrillation. The verification of R-wave detection (a fundamental aspect of these algorithms) was performed via bench and animal testing, suggesting an evaluation of the algorithm's performance independent of a human in the loop for the core detection task. Physicians later review the automatically captured EGMs.

    7. The Type of Ground Truth Used:

    • For the R-wave detection and device migration verification in the Confirm Rx™ ICM, the ground truth would likely be based on direct physiological measurements from bench testing and animal studies (e.g., direct electrical signals or physical tracking of device position).
    • For the leveraged clinical performance of the detection algorithms (from SJM Confirm™ DM2102 IDE G080090), the ground truth for arrhythmia detection would typically involve expert consensus of ECG/EGM interpretation by cardiologists or electrophysiologists, potentially corroborated with other clinical data or findings.

    8. The Sample Size for the Training Set:

    • The document does not specify a training set sample size. Given that the device leverages "identical sensing and detection algorithms" from a predicate device, the algorithms were likely developed and "trained" (or more accurately, designed and optimized) at an earlier stage with data that is not detailed in this 510(k) summary. This summary focuses on verifying the new device's implementation of those existing algorithms, not on new algorithm development.

    9. How the Ground Truth for the Training Set Was Established:

    • This information is not provided in the 510(k) summary. As mentioned, the algorithms are inherited from a predicate. Details on their initial development and the establishment of ground truth for any underlying "training" or optimization data would be found in the documentation for the predicate device (SJM Confirm™ DM2102).
    Ask a Question

    Ask a specific question about this device

    K Number
    K140793

    Validate with FDA (Live)

    Date Cleared
    2014-12-17

    (261 days)

    Product Code
    Regulation Number
    870.1340
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The Nanostim™ Introducer Kit is intended to provide a conduit into the venous system for insertion of diagnostic and other interventional devices.

    Device Description

    The St Jude Medical Nanostim Introducer Kit is designed to perform as a guiding sheath for introduction of diagnostic and interventional devices. The Nanostim™ Introducer Kit is comprised of an Introducer sheath and a dilator. The Introducer Kit is compatible with 0.035" and 0.038" guidewires and is available in 18F and one length of 30 cm. The introducer sheath is fitted with a hemostasis valve to prevent blood loss and minimize air introduction during introducer insertion and/or exchange. A sideport with a three-way stopcock is provided for air or blood aspiration and fluid infusion. The introducer features a radiopaque tip marker incorporated within the sheath material to identify the location of the distal tip of the sheath.

    AI/ML Overview

    This document is a 510(k) summary for the St. Jude Medical Nanostim Introducer Kit and does not contain information about a study proving the device meets specific acceptance criteria in the context of AI/ML performance, nor does it involve expert reviews or clinical trials in the way typically associated with AI/ML medical devices. The document concerns a physical medical device (catheter introducer) and its substantial equivalence to predicate devices.

    Therefore, I cannot fulfill your request to describe acceptance criteria and a study proving the device meets those criteria, as the provided document does not contain this information in the context you've outlined.

    The document discusses:

    • The device's intended use and technological characteristics.
    • Non-clinical testing (e.g., visual, dimensional, tensile, leak tests, biocompatibility).
    • A statement that clinical evaluation is not required.
    • A comparison to predicate devices to establish substantial equivalence.
    Ask a Question

    Ask a specific question about this device

    K Number
    K133481

    Validate with FDA (Live)

    Date Cleared
    2014-05-28

    (196 days)

    Product Code
    Regulation Number
    870.2800
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The SJM Confirm " ICM is indicated for the monitoring and diagnostic evaluation of patients who experience unexplained symptoms such as: dizziness, palpitations, chest pain, syncope, and shortness of breath, as well as patients who are at risk for other cardiac arrhythmias.

    The SJM Confirm ICM, Model DM2102, is also indicated for patients who have been previously diagnosed with atrial fibrillation or who are susceptible to developing atrial fibrillation.

    Device Description

    The SJM Confirm ICM is a cardiovascular monitoring device used to record and play back. physiological signals.

    AI/ML Overview

    The provided text for SJM Confirm (DM2102) ICM 5 10(k) Premarket Notification (K133481) indicates that clinical performance testing was performed to demonstrate the device meets the required performance criteria. However, the document does not provide specific acceptance criteria or detailed results of this clinical study. It primarily focuses on asserting substantial equivalence to predicate devices based on technological characteristics and general performance.

    Therefore, much of the requested information cannot be extracted from the provided text.

    Here is what can be inferred and what is missing:

    1. A table of acceptance criteria and the reported device performance

    • Acceptance Criteria: Not explicitly stated in the provided text. The document broadly states the device "meets the required performance criteria" and "performs as intended."
    • Reported Device Performance: Not explicitly stated in terms of quantitative metrics. The document concludes that "the SJM Confirm ICM functions to its specifications, performs as intended, and exhibits the appropriate characteristics of an implantable cardiovascular monitoring device."

    2. Sample size used for the test set and the data provenance

    • Sample Size for Test Set: Not specified. The document mentions "clinical performance testing" but does not provide details about the number of patients or cases.
    • Data Provenance (e.g., country of origin of the data, retrospective or prospective): Not specified.

    3. Number of experts used to establish the ground truth for the test set and the qualifications of those experts

    • Not specified. There is no mention of expert review or ground truth establishment in the context of the clinical study described.

    4. Adjudication method (e.g., 2+1, 3+1, none) for the test set

    • Not specified.

    5. If a multi-reader multi-case (MRMC) comparative effectiveness study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance

    • The document implies that the SJM Confirm is a standalone cardiac monitoring device rather than an AI-assisted interpretation tool for human readers. Therefore, an MRMC study comparing human readers with and without AI assistance is not relevant to this device's function as described. No such study is mentioned.

    6. If a standalone (i.e. algorithm only without human-in-the-loop performance) was done

    • The document states "clinical performance testing were performed to demonstrate the SJM Confirm ICM meets the required performance criteria." While it doesn't explicitly use the term "standalone performance," given that it's an "Implantable Cardiac Monitor," its primary function would be continuous, automated monitoring and recording of physiological signals. This suggests the evaluation would focus on the device's ability to accurately detect and record these signals on its own. However, specific metrics are not provided.

    7. The type of ground truth used (expert consensus, pathology, outcomes data, etc)

    • Not specified.

    8. The sample size for the training set

    • Not applicable as this seems to be a hardware device with embedded firmware/software rather than a machine learning algorithm that requires a separate training set. The relevant testing is "Software Verification and System Validation" and "Clinical Study."

    9. How the ground truth for the training set was established

    • Not applicable.
    Ask a Question

    Ask a specific question about this device

    K Number
    K131592

    Validate with FDA (Live)

    Date Cleared
    2014-01-31

    (242 days)

    Product Code
    Regulation Number
    870.1250
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    N/A
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The EnligHTN™ Renal Guiding Catheter system is indicated for percutaneous use through an introducer sheath to facilitate a pathway to introduce interventional and diagnostic devices into the renal arterial vasculature.

    Device Description

    The EnligHTN Renal Guiding Catheter consists of two primary components, the guiding catheter assembly and the dilator. The guide catheter assembly is the renal access device and has a usable length of 55cm. The outside diameter (OD) of the catheter shaft is 8F (2.7mm) with a distal tip inner diameter (ID) of 0.089 inches. The device is single use and packaged sterile via Ethylene oxide (EO) sterilization. The dilator fits inside the guiding catheter providing support during advancement through the vasculature and placement near the renal ostia. At the proximal end of the guiding catheter is a molded hub equipped with a hemostasis valve that is secured by an ultrasonically welded cap. The hub has a side port feature with an extension tubing and stopcock assembly attached. The distal end of the guiding catheter is formed to match the RDC-1 curve common to the industry and incorporates a radiopaque marker band. The dilator lumen is designed to accommodate a guidewire with an outside diameter of 0.035" or less.

    The EnligHTN Renal Guiding Catheter system includes the following design aspects:

    • 55cm Usable Length
    • Renal double curve (RDC-1) at the distal end to assist in engagement of renal ostium
    • Radiopaque marker band at the distal tip to aid in visualization under fluoroscopy
    • Hub with hemostasis valve
    • Extension tube with 3-way stopcock
    • Compatible Dilator
    AI/ML Overview

    Here's an analysis of the provided text regarding the acceptance criteria and study for the EnligHTN Renal Guiding Catheter:

    Summary of Acceptance Criteria and Device Performance (Assumed from Testing Summary)

    The document describes various performance tests conducted to demonstrate that the EnligHTN Renal Guiding Catheter meets product specifications and intended uses, and is as safe and effective as the predicate device (Cordis Guide Catheter). While explicit "acceptance criteria" are not listed with quantitative thresholds, the successful completion of these tests implies that the device met the required performance standards.

    ItemAcceptance Criteria (Implied)Reported Device Performance
    Device PerformanceMeets product specifications for: Dimensions, Kink Resistance, Torque Manipulation and Strength, Air Leak, Seal Manipulation, Hemostasis Performance, Renal Double Curve Maintenance, Tensile Strength, Corrosion Resistance.Testing demonstrated that the guide catheter's design meets product specifications and intended uses.
    BiocompatibilityMeets biological safety standards for: Cytotoxicity, Sensitization, Intracutaneous Reactivity, Acute Systemic Toxicity, Pyrogenicity, Hemolysis, Partial Thromboplastin Time, Complement Activation, In Vivo Thromboresistance, and Chemical Characterization (GC/MS, ICP, FTIR, NVR).All biocompatibility tests were successfully conducted.
    Sterilization/MicrobiologyMeets standards for: Sterilization, Ethylene Oxide Residuals, Bioburden, LAL Endotoxin.All sterilization and microbiology tests were successfully conducted.
    PackagingMeets standards for: Bubble Leak Test, Visual Inspection, Pouch Seal Strength.All packaging tests were successfully conducted.
    Shelf LifeMaintains performance over the specified shelf life of 13 months (accelerated and real-time).13-month accelerated aging and 13-month real-time aging (in-process) were conducted. (Implicitly met criteria).
    Animal Testing (In-Vivo Performance)Demonstrates satisfactory performance for: Fit of the Dilator and Catheter, Visualization, Engagement, Seal Performance, and Withdrawal Performance.Performed a study to assess fit, visualization, engagement, seal, and withdrawal. (Implicitly met criteria).

    1. A table of acceptance criteria and the reported device performance:

    (See table above)

    2. Sample size used for the test set and the data provenance (e.g. country of origin of the data, retrospective or prospective):

    • Sample Size for Test Set: The document does not explicitly state the numerical sample sizes for each specific test (e.g., how many catheters were used for kink resistance, how many animals for animal testing). It lists the types of tests performed.
    • Data Provenance: Not specified. Standard practice for medical device testing implies that these tests are performed in a controlled laboratory environment. The country of origin of the data is not mentioned and is typically not a requirement for this type of 510(k) submission unless specific clinical trial data from diverse populations is being used. This would be considered prospective bench and animal testing.

    3. Number of experts used to establish the ground truth for the test set and the qualifications of those experts (e.g. radiologist with 10 years of experience):

    • This information is not provided in the document. For bench and animal testing of this nature, "experts" in the traditional sense of medical specialists establishing ground truth for diagnostic accuracy are not typically involved. The "ground truth" would be defined by engineering specifications and expected physiological responses, assessed by engineers, technicians, and veterinarians.

    4. Adjudication method (e.g. 2+1, 3+1, none) for the test set:

    • This information is not applicable to the non-clinical (bench and animal) testing described. Adjudication methods like 2+1 or 3+1 are typically used in clinical studies, particularly those involving human interpretation of medical images, to resolve discrepancies among expert readers.

    5. If a multi-reader multi-case (MRMC) comparative effectiveness study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance:

    • No, an MRMC comparative effectiveness study was not done. This device is a physical medical device (catheter), not an AI-powered diagnostic or assistive tool. Therefore, the concept of human readers improving with AI assistance is not relevant.

    6. If a standalone (i.e. algorithm only, without human-in-the-loop performance) was done:

    • No, a standalone algorithm performance study was not done. This device is a medical catheter and does not involve any algorithms or AI.

    7. The type of ground truth used (expert consensus, pathology, outcomes data, etc.):

    • For the non-clinical tests (bench, biocompatibility, sterilization, packaging, shelf life): The "ground truth" is based on engineering specifications, recognized industry standards, and regulatory requirements (e.g., ISO standards for biocompatibility, sterility assurance levels).
    • For the animal testing: The "ground truth" for performance aspects like fit, visualization, engagement, seal, and withdrawal performance would be based on direct observation and assessment by trained personnel (e.g., veterinarians, researchers) in accordance with study protocols, confirming the device performs as intended within the physiological model.

    8. The sample size for the training set:

    • Not applicable. This document describes the testing of a physical medical device. There is no "training set" in the context of machine learning or AI algorithm development. The device's design is refined through engineering and iterative testing, not through training on a dataset.

    9. How the ground truth for the training set was established:

    • Not applicable. As there is no training set for an AI algorithm, the concept of establishing ground truth for it does not apply here.
    Ask a Question

    Ask a specific question about this device

    K Number
    K073700

    Validate with FDA (Live)

    Device Name
    6F PROXIS SYSTEM
    Date Cleared
    2008-10-02

    (276 days)

    Product Code
    Regulation Number
    870.1250
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    N/A
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The 6F Proxis System controls the flow of fluids in the coronary and peripheral vasculature. This is achieved by temporary vessel occlusion to hold a column of fluid in the vessel stagnant. The stagnant column can be used to aid in the visualization of the lesion or be used as a means of local and temporary delivery of therapeutic solutions.

    The 6F Proxis System is also indicated for use as an aid in the removal of fresh, soft emboli and thrombi in the coronary and peripheral vasculature.

    The safety and efficacy of this device as an embolic protection system has not been established. The 6F Proxis System is not indicated for use for embolic protection. The device is not intended to be used as a thrombectomy system.

    Device Description

    The 6F Proxis System (Proxis System) is a proximal flow control system used in conjunction with other interventional devices. The Proxis System controls the flow of fluids in the coronary and peripheral vasculature. This is achieved by temporarily occluding the vessel which holds the column of fluid stagnant. The stagnant column can be used to aid in the visualization of the lesion and for the delivery of therapeutic solution(s).

    The Proxis System consists of an Evacuation Sheath Catheter (Proxis Catheter), inflation device. aspiration syringe, lip seal, and strainer basket. In addition, an optional accessory called the Proxis Infusion Catheter (packaged separately) may be used with Proxis System.

    The Proxis Catheter is loaded onto the guide wire and tracked down to the distal portion of the guide catheter and proximal to the lesion. When the sealing balloon is inflated, antegrade flow of the fluid in the target vessel is prevented.

    While the vessel is occluded, therapeutic solutions may be infused through the Proxis Catheter and stagnated in the target vessel/lesion during the delivery of the therapeutic device or after the deployment of the therapeutic device.

    The aspiration syringe is provided for the removal of stagnated fluid and/or fresh, soft thrombi and emboli during aspiration. Additionally, if there is insufficient venous or collateral flow, the Proxis Infusion Catheter (optional accessory) may be used to infuse saline to augment the retrograde flow of fluid and removal of stagnated fluid.

    AI/ML Overview

    The provided text describes a Special 510(k) submission for the 6F Proxis™ System. This type of submission is used when modifications to a legally marketed device do not raise new questions of safety or effectiveness. As such, the study performed is a verification study against established specifications of predicate devices, rather than a clinical trial with acceptance criteria for device performancemetrics.

    Here's an analysis based on the provided text:

    1. Table of Acceptance Criteria and Reported Device Performance

    Acceptance Criteria CategoryReported Device Performance (as stated in the submission)
    Dimensional SpecificationsPassed all verification specification criteria (K063638)
    Strength SpecificationsPassed all verification specification criteria (K063638)
    Functional SpecificationsPassed all verification specification criteria (K063638)
    Packaging SpecificationsPassed all verification specification criteria (K063638)
    Sterilization SpecificationsPassed all verification specification criteria (K063638)
    BiocompatibilityPassed all verification specification criteria (K063638)
    Shelf LifePassed all verification specification criteria (K063638)
    Substantial EquivalenceConfirmed to be substantially equivalent to K063638 and K052523, with identical technological characteristics and principles of operation, and similar intended uses.

    2. Sample Size Used for the Test Set and Data Provenance

    The document does not specify a "test set sample size" in the context of a clinical study. Instead, it refers to verification testing against specifications. The sample sizes for these engineering and laboratory tests (e.g., for dimensional, strength, functional properties) are not detailed in this summary, but would typically be part of the underlying design verification documentation. The data provenance is implied to be from the manufacturer's internal testing facilities, used for previous 510(k) clearances (K063638 and K052523), and is retrospective in the sense that the current submission leverages prior clearance data. No specific country of origin for the data is mentioned for these engineering tests.

    3. Number of Experts Used to Establish Ground Truth for the Test Set and Qualifications

    Not applicable. For this type of submission (Special 510(k) based on device modifications), clinical expert consensus for "ground truth" on patient data is not the primary basis for demonstrating safety and efficacy. Instead, the focus is on engineering and laboratory performance meeting established specifications.

    4. Adjudication Method for the Test Set

    Not applicable. Given that this is a Special 510(k) submission primarily relying on design verification and substantial equivalence to predicate devices, an adjudication method for a clinical test set is not described or required.

    5. If a Multi-Reader Multi-Case (MRMC) Comparative Effectiveness Study Was Done

    No. An MRMC comparative effectiveness study is designed to assess human reader performance, often with and without AI assistance, or comparing different diagnostic methods. This submission for the 6F Proxis™ System is for a physical medical device (catheter system) and its modifications, not a diagnostic imaging AI algorithm. Therefore, such a study was not performed.

    6. If a Standalone (i.e., algorithm only without human-in-the-loop performance) Was Done

    No. This question typically pertains to AI/CADe (Computer-Aided Detection) or CADx (Computer-Aided Diagnosis) devices. The 6F Proxis™ System is a percutaneous catheter system; therefore, a standalone algorithm performance study is not relevant.

    7. The Type of Ground Truth Used

    The "ground truth" in this context is defined by engineering specifications and performance parameters established for the device components and system. These specifications are derived from recognized standards, clinical needs for the intended use, and the performance of previously cleared predicate devices. The "truth" is that the device meets these predetermined technical and functional requirements.

    8. The Sample Size for the Training Set

    Not applicable. The concept of a "training set" applies to machine learning algorithms. The 6F Proxis™ System is a physical medical device, not an AI/ML product.

    9. How the Ground Truth for the Training Set Was Established

    Not applicable, as there is no "training set" for this device.

    Ask a Question

    Ask a specific question about this device

    K Number
    K060954

    Validate with FDA (Live)

    Date Cleared
    2006-04-21

    (14 days)

    Product Code
    Regulation Number
    870.1425
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The EnSite System is indicated for patients for whom electrophysiology studies are indicated.
    When used with the EnSite* Catheter, the EnSite System is intended to be used in . the right atrium of patients with complex arrhythmias that may be difficult to identify using conventional mapping systems alone.
    OR
    When used with the EnSite NavX™ Surface Electrode Kit, the EnSite System is . intended to display the position of conventional electrophysiology catheters in the heart.

    Device Description

    The EnSite System is a computerized storage and display system for use in electrophysiology studies of the human heart. The system consists of a console workstation, patient interface unit, and an electrophysiology mapping catheter or surface electrode kit.

    AI/ML Overview

    This 510(k) summary does not contain the level of detail necessary to answer all the questions about acceptance criteria and the study proving the device meets them as typically presented for AI/ML-based medical devices. This document predates the widespread use of sophisticated AI/ML in medical devices and therefore focuses on traditional medical device validation.

    Based on the provided information, here's what can be extracted and what cannot:

    1. A table of acceptance criteria and the reported device performance

    The document does not explicitly state quantitative acceptance criteria or detailed performance metrics in the format requested for an AI/ML device. Instead, it relies on a qualitative assessment of "safety and effectiveness" compared to a predicate device.

    Acceptance CriteriaReported Device Performance
    Safety"as safe as the previously marketed device"
    Effectiveness"as effective as the previously marketed device"
    No new safety/effectiveness issues"does not raise any new issues of safety and effectiveness"
    Bench and User Tests"The changes made to the EnSite System underwent a battery of bench and user tests. Device validation testing was conducted in accordance with in-house procedures." (Specific results not provided)

    2. Sample sized used for the test set and the data provenance (e.g. country of origin of the data, retrospective or prospective)

    This information is not provided in the document. The abstract mentions "bench and user tests," but details on sample size, data type, or provenance are omitted.

    3. Number of experts used to establish the ground truth for the test set and the qualifications of those experts (e.g. radiologist with 10 years of experience)

    This information is not provided. Given the nature of the device (an electrophysiology cardiac mapping system and its components), ground truth would likely be established through physician observation during electrophysiology studies, but the specifics are absent.

    4. Adjudication method (e.g. 2+1, 3+1, none) for the test set

    This information is not provided.

    5. If a multi reader multi case (MRMC) comparative effectiveness study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance

    A multi-reader multi-case (MRMC) comparative effectiveness study as typically understood for AI/ML evaluation was not performed or reported. The document describes a traditional medical device submission based on substantial equivalence to a predicate device, not an AI efficacy study. The concept of "human readers improve with AI vs without AI assistance" is not applicable here as it is not an AI/ML device in the modern sense.

    6. If a standalone (i.e. algorithm only without human-in-the-loop performance) was done

    This concept is not applicable to this device. The EnSite System is a computerized storage and display system that supports electrophysiology studies, not a standalone AI algorithm producing diagnoses or interpretations without human involvement. Its "performance" is inherently linked to its use by an electrophysiologist in conjunction with catheters or surface electrodes.

    7. The type of ground truth used (expert concensus, pathology, outcomes data, etc)

    The document does not specify the type of ground truth. For an electrophysiology mapping system, "ground truth" would likely relate to accurate identification and visualization of cardiac activation patterns and catheter positions, validated through clinical observation and established electrophysiological principles, rather than pathology or outcomes data in the traditional sense of a diagnostic AI device.

    8. The sample size for the training set

    This information is not provided and is not applicable in the context of this traditional medical device submission. The device is not an AI/ML system that undergoes "training" in the computational sense.

    9. How the ground truth for the training set was established

    This information is not provided and is not applicable.

    Ask a Question

    Ask a specific question about this device

    K Number
    K042734

    Validate with FDA (Live)

    Date Cleared
    2004-12-17

    (77 days)

    Product Code
    Regulation Number
    870.3800
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    N/A
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The SJM™ Rigid Saddle ring is indicated for use to correct annular dilation, increase leaflet coaptation, and prevent further dilatation of the mitral valve annulus caused by diseased states such as degenerative disease, rheumatic disease, Ischemia or vascular disease. The combination of prosthetic ring with valvuloplasty may be used in all acquired or congenital mitral insufficiencies with dilation and deformation of the fibrous mitral annulus.

    For mitral insufficiencies with no subvalvular lesions and normal valvular movements, r of that ring implant alone may be sufficient. However, annuloplasty ring implant along with mitral valvuloplasty repair must be considered for insufficiencies with a prolapsed while mark relongation or rupture of the chordae tendineae and for insufficiencies with valve ado to blongation ements due to fusion of the commissures or chordae tendineae, or chordal hypertrophy.

    Device Description

    The SJM™ Rigid Saddle Ring assembly consists of a rigid core machined from titanium covered with a double velour polyester fabric with a sewing cuff created for suturability. The ring is mounted on a holder and placed in a dual barrier package system. The package system is then steam sterilized. The SJM™ Rigid Saddle Ring is available in sizes 24mm-34mm (even sizes). Sizing is based on the inter-commissural distance as indicated by the commissure markers placed on the ring.

    AI/ML Overview

    The provided text describes a 510(k) premarket notification for the "SJM™ Rigid Saddle Ring" (Model RSAR). This submission aims to demonstrate substantial equivalence to a predicate device, not to establish new performance criteria through a study with acceptance criteria in the same way one might for a novel device or AI software. Therefore, much of the requested information regarding acceptance criteria, extensive studies, expert ground truth, and training sets for an AI device is not directly applicable.

    However, I can extract and present the information available from the document in a structured way that aligns with your request where possible, and clearly state when information is not provided or applicable.

    Here's a breakdown based on the provided text:

    1. Table of Acceptance Criteria and Reported Device Performance

    The document does not specify "acceptance criteria" in a quantitative sense as might be typical for a new device's performance study (e.g., minimum sensitivity/specificity). Instead, the submission relies on demonstrating substantial equivalence to a predicate device based on characteristics and non-clinical testing. The "reported device performance" is the conclusion that it is "safe and effective for the intended use" and "substantially equivalent" to predicate devices.

    Characteristic Tested (Non-Clinical)Acceptance/Equivalency StandardReported Device Performance
    Product LabelingSubstantially EquivalentSubstantially Equivalent
    Intended UseSubstantially EquivalentSubstantially Equivalent
    Physical CharacteristicsSubstantially EquivalentSubstantially Equivalent
    Anatomical SitesIdenticalIdentical
    Target PopulationSubstantially EquivalentSubstantially Equivalent
    Performance TestingSubstantially EquivalentSubstantially Equivalent
    Safety CharacteristicsSubstantially EquivalentSubstantially Equivalent
    Ring Tensile StrengthNot explicitly statedConducted
    Ring Compressive StrengthNot explicitly statedConducted
    Suture Pullout TestNot explicitly statedConducted
    Needle Penetration TestNot explicitly statedConducted
    Computational Structural AnalysisNot explicitly statedConducted
    Holder EvaluationNot explicitly statedConducted
    Assembled Ring/Holder EvaluationNot explicitly statedConducted
    MR SafetyNot explicitly statedConducted
    Package Shelf Life EvaluationNot explicitly statedConducted
    Manufacturing Process ValidationNot explicitly statedConducted
    Biocompatibility EvaluationNot explicitly statedConducted
    Chemical and Morphological EvaluationNot explicitly statedConducted
    Sterilization ValidationNot explicitly statedConducted
    BioburdenNot explicitly statedConducted
    PyrogenicityNot explicitly statedConducted

    2. Sample size used for the test set and the data provenance

    This information is not provided in the document. The submission details "non-clinical tests" but does not specify the sample sizes for these tests or the origin of any data (as it's not a study on patient data).

    3. Number of experts used to establish the ground truth for the test set and the qualifications of those experts

    This information is not applicable as this is a submission for a medical device (an annuloplasty ring), not an AI device requiring expert-established ground truth from medical imaging or patient data. The "ground truth" for a mechanical device would be laboratory measurements against relevant standards or engineering specifications.

    4. Adjudication method for the test set

    This information is not applicable for the same reasons as point 3.

    5. If a multi reader multi case (MRMC) comparative effectiveness study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance

    This information is not applicable as this is a medical device, not an AI or imaging diagnostic device that would involve human readers.

    6. If a standalone (i.e. algorithm only without human-in-the-loop performance) was done

    This information is not applicable as this is a medical device, not an algorithm.

    7. The type of ground truth used

    For the non-clinical tests conducted, the "ground truth" would be established by engineering specifications, material science standards, and accepted physiological/biocompatibility benchmarks. The document lists tests like "Ring Tensile Strength," "Biocompatibility Evaluation," and "Sterilization Validation," implying that these were assessed against a set of predetermined criteria based on these standards.

    8. The sample size for the training set

    This information is not applicable as this is a medical device, not an AI device trained on data.

    9. How the ground truth for the training set was established

    This information is not applicable as this is a medical device, not an AI device.

    Ask a Question

    Ask a specific question about this device

    K Number
    K022363

    Validate with FDA (Live)

    Date Cleared
    2002-09-19

    (59 days)

    Product Code
    Regulation Number
    870.3800
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    N/A
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The SJM® Tailor™ annuloplasty band is indicated for use in the repair of a mitral or tricuspid valve that is diseased or damaged due to acquired or congenital processes.

    Device Description

    The Tailor band is a flexible band fabricated with a medical grade silicone rubber core, surrounded by polyester fabric.

    AI/ML Overview

    The provided document is a 510(k) summary for a medical device, the SJM® Tailor™ annuloplasty band. This type of submission focuses on demonstrating substantial equivalence to a legally marketed predicate device rather than conducting new clinical studies to establish acceptance criteria and performance. Therefore, most of the requested information regarding acceptance criteria, study details, and human-AI comparative effectiveness is not applicable to this document.

    Here's a breakdown of the parts that can be addressed based on the provided text:

    1. A table of acceptance criteria and the reported device performance

    The document does not specify "acceptance criteria" in a quantitative sense for performance metrics like sensitivity, specificity, or accuracy. Instead, the "acceptance criteria" are implied by demonstrating substantial equivalence to the predicate device through various non-clinical tests.

    CharacteristicAcceptance Criteria (Implied by Substantial Equivalence)Reported Device Performance
    Product LabelingSubstantially Equivalent to predicateSubstantially Equivalent
    Intended UseIdentical to predicateIdentical
    Physical CharacteristicsSubstantially Equivalent to predicateSubstantially Equivalent
    Anatomical SitesIdentical to predicateIdentical
    Target PopulationIdentical to predicateIdentical
    Performance TestingIdentical to predicateIdentical
    Safety CharacteristicsIdentical to predicateIdentical
    Band end evaluationDemonstrated satisfactory performance in comparison to predicatePerformed
    GappingDemonstrated satisfactory performance in comparison to predicatePerformed
    Band releaseDemonstrated satisfactory performance in comparison to predicatePerformed
    Suture RetentionDemonstrated satisfactory performance in comparison to predicatePerformed
    Suture pullDemonstrated satisfactory performance in comparison to predicatePerformed
    Biocompatibility evaluationDemonstrated satisfactory performancePerformed
    Sterility Assurance evaluationDemonstrated satisfactory performancePerformed
    Manufacturing Process ValidationDemonstrated satisfactory performancePerformed

    2. Sample size used for the test set and the data provenance (e.g. country of origin of the data, retrospective or prospective)

    • Sample size for the test set: Not applicable. This submission relies on non-clinical testing and comparison to a predicate device, not a patient-based test set in the context of AI or diagnostic performance. The tests mentioned are for material and mechanical properties, not clinical assessment on patients.
    • Data provenance: Not applicable. The tests performed are laboratory-based and do not involve patient data.

    3. Number of experts used to establish the ground truth for the test set and the qualifications of those experts

    Not applicable. There is no "ground truth" establishment by experts in the context of image interpretation or diagnosis for this device's non-clinical testing. The tests are physical and microbiological validations.

    4. Adjudication method (e.g. 2+1, 3+1, none) for the test set

    Not applicable. There is no "adjudication method" in the context of clinical interpretation or expert review for this type of non-clinical testing.

    5. If a multi reader multi case (MRMC) comparative effectiveness study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance

    Not applicable. This is a medical device for heart valve repair (an annuloplasty band), not an AI diagnostic or assistance tool that would undergo MRMC studies involving human readers.

    6. If a standalone (i.e. algorithm only without human-in-the-loop performance) was done

    Not applicable. This is a physical medical device, not an algorithm.

    7. The type of ground truth used (expert consensus, pathology, outcomes data, etc)

    Not applicable. The "ground truth" for the non-clinical tests would be the established scientific and engineering principles for material integrity, mechanical strength, and biocompatibility, as well as validated testing methods. It's not a clinical "ground truth" derived from patient-specific data.

    8. The sample size for the training set

    Not applicable. This is not an AI or machine learning device requiring a training set.

    9. How the ground truth for the training set was established

    Not applicable.

    Ask a Question

    Ask a specific question about this device

    K Number
    K014161

    Validate with FDA (Live)

    Date Cleared
    2002-01-15

    (27 days)

    Product Code
    Regulation Number
    870.3800
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The SJM® Tailor™ annuloplasty ring is indicated for use in the repair of a mitral or tricuspid valve that is diseased or damaged due to acquired or congenital processes.

    Device Description

    The Tailor ring is a flexible ring fabricated with a medical grade silicone rubber core, surrounded by polyester fabric. The full ring may be cut to form a partial or "C" ring.

    AI/ML Overview

    The provided text is a 510(k) summary for the SJM® Tailor™ annuloplasty ring, model TARP. This document primarily focuses on establishing substantial equivalence to a predicate device (Tailor ring, model TARN) rather than presenting a standalone study with specific acceptance criteria and detailed device performance metrics in the way one might expect for a new AI/software device.

    Therefore, the requested information, particularly regarding acceptance criteria and a study that proves the device meets those criteria (in terms of performance metrics like sensitivity, specificity, etc.), sample sizes for test sets, data provenance, number of experts, adjudication methods, MRMC studies, standalone performance, ground truth types for test and training sets, and training set sample sizes, is not present in the provided document.

    The document is about a physical medical device (annuloplasty ring) and its substantial equivalence based on physical, non-clinical, and safety characteristics. It is not about a software or AI device that would typically have the kind of performance study details requested.

    However, I can extract the information that is present regarding the comparison and testing:

    1. A table of acceptance criteria and the reported device performance

    The document doesn't provide "acceptance criteria" in terms of performance metrics (like accuracy, sensitivity, etc.) or specific numerical thresholds. Instead, it demonstrates substantial equivalence to a predicate device based on characteristics and non-clinical testing.

    CharacteristicEquivalency ClaimTesting/Rationale
    Product LabelingSubstantially EquivalentImplied by submission for marketing based on predicate.
    Intended UseIdentical"repair of diseased or damaged mitral or tricuspid heart valves".
    Physical CharacteristicsDifferent (Holder and Handle only)Non-Clinical Tests Performed: Holder to Handle connection, Holder assembly, Ring assembly to holder. (No specific numerical results reported in this summary).
    Anatomical SitesIdenticalMitral or tricuspid heart valves.
    Target PopulationIdenticalPatients with diseased or damaged mitral or tricuspid heart valves determined to be repairable.
    Performance TestingSubstantially EquivalentRefers to predicate device (K000119) and testing for new holder/handle. (No specific numerical results reported in this summary).
    Safety CharacteristicsSubstantially EquivalentNon-Clinical Tests Performed: Microbiological Testing (Biocompatibility, Sterility Assurance), Manufacturing Process Validation. (No specific numerical results reported in this summary).

    2. Sample size used for the test set and the data provenance (e.g. country of origin of the data, retrospective or prospective)

    Not applicable. The document describes non-clinical engineering and biological testing, not a clinical study on patient data with a "test set."

    3. Number of experts used to establish the ground truth for the test set and the qualifications of those experts (e.g. radiologist with 10 years of experience)

    Not applicable. This is not a study requiring expert-established ground truth on a test set.

    4. Adjudication method (e.g. 2+1, 3+1, none) for the test set

    Not applicable.

    5. If a multi reader multi case (MRMC) comparative effectiveness study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance

    Not applicable. This is not an AI or software device.

    6. If a standalone (i.e. algorithm only without human-in-the-loop performance) was done

    Not applicable. This is not an AI or software device.

    7. The type of ground truth used (expert consensus, pathology, outcomes data, etc)

    For the non-clinical tests conducted (e.g., physical testing, microbiological testing), the "ground truth" would be established by standard engineering specifications, material properties, and biological testing protocols relevant to medical devices, not by expert consensus on clinical cases or pathology.

    8. The sample size for the training set

    Not applicable. This is not an AI/ML device that requires a training set.

    9. How the ground truth for the training set was established

    Not applicable.

    Ask a Question

    Ask a specific question about this device

    Page 1 of 2