510(k) Data Aggregation

    K Number
    K223251

    Validate with FDA (Live)

    Device Name
    Hexanium PLIF
    Date Cleared
    2022-12-16

    (56 days)

    Product Code
    Regulation Number
    888.3080
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    N/A
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The Hexanium® PLIF (Posterior Lumbar Interbody Fusion) system is an intervertebral body fusion device indicated for use with autogenous bone graft in skeletally mature patients with Degenerative Disc Disease (DDD) at one or two continuous levels from L2-S1. DDD is defined as discogenic back pain with degeneration of the disc confirmed by patient history and radiographic studies. These DDD patients may also have up to Grade I spondylolisthesis or retrolisthesis at the involved level(s). Patients should have received at least 6 months of non-operative treatment prior to treatment with Hexanium PLIF system. This device has to be filled with autogenous bone graft material. This device is implanted via the posterior approach. Hexanium PLIF system must be used in combination with supplemental internal spinal fixation which has been cleared by the FDA for use in the lumbar spine.

    Device Description

    The Hexanium® PLIF (Posterior Lumbar Interbody Fusion) is a titanium alloy (Ti6Al4V ELI) interbody cage manufactured via an Additive Manufacturing method. The honeycomb structure allows for bone through-growth through the structure of the cage as well as providing lateral and vertical bone graft windows in the body of the cage. Hexanium® PLIF cages are available in heights of 7-16 mm (in 1 mm increments), width of 9 mm, lengths of 22 and 25 mm, and lordosis angles of 0°, 5°, and 8°. Hexanium® PLIF cages are provided sterile and supplied with a set of non-sterile surgical instruments.

    AI/ML Overview

    The Hexanium® PLIF (Posterior Lumbar Interbody Fusion) system is an intervertebral body fusion device. The provided text lacks the detailed "acceptance criteria" and subsequent "reported device performance" typically found in a clinical study report for AI-powered devices. The document is a 510(k) summary for a medical device (an intervertebral body fusion device, not an AI device) where equivalence to a predicate device is established through mechanical testing, not clinical performance data. Therefore, the questions related to AI device performance metrics, such as sensitivity, specificity, or human-in-the-loop performance, and associated study details are not applicable here.

    However, I can extract information related to the device's performance data that was provided to demonstrate substantial equivalence:

    1. A table of acceptance criteria and the reported device performance:

    The document states that the Hexanium® PLIF cages conform to the FDA guidance "Guidance for Industry and FDA Staff – Class II Special Controls Guidance Document: Intervertebral Body Fusion Device" dated June 12, 2007. The device was evaluated against predetermined functional and performance requirements and external standard requirements.

    Test TypeAcceptance Criteria (Implied by adherence to standards)Reported Device Performance (Implied by "meets the same... requirements")
    Mechanical TestingConformity to ASTM F2077, ASTM F2267, and draft ASTM F-04.25.02.02 for intervertebral body fusion devices.Hexanium® PLIF cages met these pre-determined functional and performance requirements.
    Static CompressionMeets force/displacement, stiffness, and permanent deformation requirements as per ASTM F2077.Performed according to ASTM F2077, implying requirements were met.
    Static Compression-ShearMeets force/displacement, stiffness, and permanent deformation requirements as per ASTM F2077.Performed according to ASTM F2077, implying requirements were met.
    Static TorsionMeets torque/angle, stiffness, and permanent deformation requirements as per ASTM F2077.Performed according to ASTM F2077, implying requirements were met.
    Dynamic CompressionWithstands specified number of cyclic loads at defined forces without fracture or excessive deformation as per ASTM F2077.Performed according to ASTM F2077, implying requirements were met.
    Dynamic Compression-ShearWithstands specified number of cyclic loads at defined forces without fracture or excessive deformation as per ASTM F2077.Performed according to ASTM F2077, implying requirements were met.
    Dynamic TorsionWithstands specified number of cyclic loads at defined torques without fracture or excessive deformation as per ASTM F2077.Performed according to ASTM F2077, implying requirements were met.
    Subsidence TestingMeets subsidence resistance requirements as per ASTM F2267.Performed according to ASTM F2267, implying requirements were met.
    Expulsion TestingMeets expulsion resistance requirements as per draft ASTM F-04.25.02.02.Performed according to draft ASTM F-04.25.02.02, implying requirements were met.
    BiocompatibilityMeets pyrogenicity limits.Bacterial Endotoxins Test performed in accordance with USP, implying pyrogen limit specifications were met.

    2. Sample size used for the test set and the data provenance:

    • Sample Size: Not specified in the document for mechanical testing. These tests typically involve a specific number of device samples (e.g., typically N=6 or more) for each test configuration, as defined by the ASTM standards, but the exact number is not provided.
    • Data Provenance: The tests are laboratory-based mechanical and biocompatibility tests, not human data. The document does not specify a country of origin for the testing itself, but the submitter is based in France.

    3. Number of experts used to establish the ground truth for the test set and the qualifications of those experts:

    This question is not applicable. The device is not an AI device requiring expert-established ground truth for a test set. The performance is assessed against engineering standards and material properties.

    4. Adjudication method for the test set:

    This question is not applicable. There was no clinical adjudication for an AI device. Mechanical and biocompatibility tests are assessed against predefined pass/fail criteria from international standards.

    5. If a multi reader multi case (MRMC) comparative effectiveness study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance:

    This question is not applicable. No MRMC study was conducted as this is not an AI device. The document explicitly states: "No clinical data has been presented."

    6. If a standalone (i.e. algorithm only without human-in-the-loop performance) was done:

    This question is not applicable. This is not an AI device.

    7. The type of ground truth used:

    For mechanical testing, the "ground truth" is defined by the objective pass/fail criteria established within the referenced ASTM international standards for intervertebral body fusion devices (e.g., F2077, F2267, F-04.25.02.02). For biocompatibility, the ground truth is the pyrogen limit specification as per USP.

    8. The sample size for the training set:

    This question is not applicable. There is no training set as this is not an AI/machine learning device. The device's design and manufacturing process are based on established engineering principles for intervertebral body fusion devices.

    9. How the ground truth for the training set was established:

    This question is not applicable. There is no training set for an AI device. The device's performance is demonstrated through in-vitro mechanical and biocompatibility testing against predefined standards.

    Ask a Question

    Ask a specific question about this device

    K Number
    K221578

    Validate with FDA (Live)

    Device Name
    Hexanium ACIF
    Date Cleared
    2022-11-14

    (166 days)

    Product Code
    Regulation Number
    888.3080
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The Hexanium® ACIF (Anterior Cervical Interbody Fusion) system is an intervertebral body fusion device indicated for use with autogenous bone graft in skeletally mature patients with Degenerative Disc Disease (DDD) at one level from C3-T1. DDD is defined as discogenic neck pain with degeneration of the disc confirmed by patient history and radiographic studies. These DDD patients may also have up to Grade I spondylolisthesis or retrolisthesis at the involved level(s). Patients should have received at least 6 weeks of non-operative treatment prior to treatment with Hexanium® ACIF system. This device has to be filled with autogenous bone graft material. This device is implanted via an anterior approach.

    Device Description

    The Hexanium® ACIF is a titanium alloy (Ti6Al4V ELI) interbody cage manufactured via an Additive Manufacturing method. The honeycomb structure allows for bone through-growth through the structure of the device as well as providing lateral and vertical bone graft windows in the body of the cage. Hexanium® ACIF is available in 2 sagittal profiles (lordotic 6º and convex 6°), heights of 5-12 mm, and 3 footprints (15x12mm, 17x14mm, and 19x15mm). The Hexanium® ACIF screws are self-drilling and available in lengths of 10, 12, 14, and 16mm and diameters of 3.50 and 3.80mm. Hexanium® ACIF is provided sterile. The Hexanium® ACIF system includes a set of reusable surgical instruments. The purpose of this Special 510(k) application is to propose minor modifications to the currently cleared surgical instruments. There are no modifications being proposed for the implantable components of the system

    AI/ML Overview

    This is not an AI/ML medical device. This is a medical device for intervertebral body fusion. Thus the acceptance criteria for AI devices do not apply here.

    Ask a Question

    Ask a specific question about this device

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    When used for anterior screw fixation or as a posterior, non-pedicle system of the U.L.I.S.™ and LUMISTM systems are indicated for:
    · degenerative disc disease (discogenic back pain with degeneration of the disc confirmed by history and radiographic studies)

    • · spondylolisthesis
    • · fracture
    • · spinal stenosis
    • · curvatures (i.e. scoliosis, kyphosis, and/or lordosis)
    • tumors
    • · failed previous fusion (pseudoarthrosis)

    The U.L.I.S.™ and LUMIS™ systems are pedicle screw systems indicated for skeletally mature patients who:

    • · have severe spondylolisthesis (Grades 3 and 4) at the L5-S1 vertebra;
    • · receive fusions using autogenous bone graft only;
    • · have the device fixed or attached to the lumbar and sacral spine (L3 to sacrum); and
    • · have the device removed after the development of a solid fusion.

    In addition, the U.L.I.S.™ and LUMIS™ systems are pedicle screw systems intended to provide immobilization and stabilization of spinal segments in skeletally mature patients as an adjunct to fusion in the following acute and chronic instabilities or deformities of the thoracic, lumbar, and sacral spine (T10-S1):

    • · degenerative spondylolisthesis with objective evidence of neurologic impairment
    • · fracture
    • · curvatures (i.e. scoliosis, kyphosis, and/or lordosis)
    • · spinal tumor
    • · failed previous fusion (pseudoarthrosis)
    Device Description

    The SpineVision® Universal Lumbar Intuitive System (U.L.I.S.™ System), and Lumbar Universal Minimally Invasive System (LUMIS™ System) are composed of cannulated (LUMIS™) and non-cannulated (U.L.I.S.™) pedicle screws and fixation rods Their components can be rigidly assembled in a variety of constructs, each corresponding to the needs and anatomy of a specific patient and are supplied non-sterile.
    The purpose of this submission is to include design modification and new diameters and lengths of the LUMIS™ Cannulated Polyaxial Pedicle Screws and U.L.I.S.™ Polyaxial Pedicle Screws, creation of LUMIS™ Cannulated Monobloc Pedicle Screws and U.L.I.S.™ Monobloc Pedicle Screws, addition of CoCr Spinal Rods, and new lengths of UNI-Thread® rods.

    AI/ML Overview

    The provided text describes a medical device submission (K133575) for the SpineVision LUMIS™ Cannulated Pedicle Screw Fixation System and U.L.I.S.™ Pedicle Screw Fixation System. The submission focuses on demonstrating substantial equivalence to predicate devices through mechanical testing, not through clinical or AI-powered studies. Therefore, many of the requested elements (like sample size for test sets, expert qualifications, and AI-specific metrics) are not applicable or cannot be extracted directly from this document.

    Here's the information that can be extracted and a clear indication where certain information is not provided:

    Acceptance Criteria and Device Performance

    1. Table of Acceptance Criteria and Reported Device Performance

    The acceptance criteria for the SpineVision LUMIS™ and U.L.I.S.™ systems are primarily based on demonstrating comparable mechanical properties to legally marketed predicate devices.

    Acceptance CriteriaReported Device Performance
    Mechanical Properties Comparability: Must demonstrate mechanical properties comparable to predicate devices. This is assessed via specific ASTM standards.Met. Mechanical testing was conducted per ASTM F1717-13 "Standard Test Methods for Spinal Implant Constructs in Vertebrectomy Model" (including Static Compression, Static Torsion, and Dynamic Compression) and ASTM F1798-13 "Standard Test Method for Evaluating the Static and Fatigue Properties of Interconnection Mechanisms and Subassemblies Used in Spinal Arthrodesis Implants" (Transverse Test Apparatus for Subassembly). The results "demonstrate comparable mechanical properties to the predicate devices."
    Material Compliance: Materials used must conform to specified ASTM and ISO standards for biocompatibility and strength.Met. The devices are manufactured in Titanium Ti-6Al-4V ELI per ASTM F136 (ISO 5832-3) and Cobalt Chromium (CoCr) alloy per ASTM F1537.
    Special Control Conformance: Must conform to special controls established for Pedicle Screw Spinal Systems and to the "Spinal System 510(k)s - Guidance for Industry and FDA Staff Document" issued on May 3, 2004.Met. The devices conform to these guidelines.
    Substantial Equivalence: Device must be substantially equivalent to predicate devices in terms of intended use, material, design, mechanical properties, and function.Met. The submission concludes "[the devices] are substantially equivalent to their predicate devices in terms of intended use, material, design, mechanical properties and function."

    2. Sample size used for the test set and the data provenance

    • Sample Size for Test Set: This information is not provided. The study involved mechanical testing of device components, not a test set of patient data.
    • Data Provenance: Not applicable in the context of mechanical testing. The testing was conducted in a laboratory setting as part of the device's engineering analysis and design validation/verification.

    3. Number of experts used to establish the ground truth for the test set and the qualifications of those experts

    Not applicable. There was no "ground truth" derived from expert consensus on patient data. The "truth" in this context is established by engineering standards and measurements from mechanical tests.

    4. Adjudication method (e.g. 2+1, 3+1, none) for the test set

    Not applicable. This concept applies to human-reviewed data, not mechanical testing results where outcomes are quantifiable and objectively measured against engineering standards.

    5. If a multi reader multi case (MRMC) comparative effectiveness study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance

    Not applicable. This device is a pedicle screw fixation system, not an AI-powered diagnostic or assistive tool for human readers. No MRMC study was conducted, and the concept of "human readers improve with AI" is irrelevant to this submission.

    6. If a standalone (i.e. algorithm only without human-in-the-loop performance) was done

    Not applicable. This device is a physical medical implant, not an algorithm.

    7. The type of ground truth used (expert consensus, pathology, outcomes data, etc)

    The "ground truth" for demonstrating the device's safety and effectiveness relies on engineering standards and direct measurements from mechanical testing. The comparability to predicate devices, as assessed through these tests, serves as the basis for the substantial equivalence determination. There is no clinical ground truth (like pathology or outcomes data) mentioned in this summary for the purpose of demonstrating equivalence.

    8. The sample size for the training set

    Not applicable. This submission concerns a physical medical device and its mechanical properties, not a machine learning model. Therefore, there is no "training set."

    9. How the ground truth for the training set was established

    Not applicable, as there is no training set for a machine learning model.

    Ask a Question

    Ask a specific question about this device

    K Number
    K130302

    Validate with FDA (Live)

    Manufacturer
    Date Cleared
    2013-07-30

    (173 days)

    Product Code
    Regulation Number
    888.3070
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    When used for anterior screw fixation or as a posterior, non-pedicle system of the noncervical spine, the U.L.I.S. ™ and LUMIS™ systems are indicated for:

    · degenerative disc disease (discogenic back pain with degeneration of the disc confirmed by history and radiographic studies)

    • · spondylolisthesis
    • fracture
    • · spinal stenosis
    • · tumors
    • · failed previous fusion (pseudoarthrosis)

    The U.L.I.S. ™ and LUMIS™ systems are pedicie screw systems indicated for skeletally mature patients who:

    • · have severe spondvlolisthesis (Grades 3 and 4) at the L5-S1 vertebra;
    • · receive fusions using autogenous bone graft only;
    • have the device fixed or attached to the lumbar and sacral spine (L3 to sacrum); and
      • · have the device removed after the development of a solid fusion.

    In addition, the U.L.I.S.™ and LUMIS™ systems are pedicle screw systems intended to provide immobilization and stabilization of spinal segments in skeletally mature patients as an adjunct to fusion in the treatment of the following acute and chronic instabilities or deformities of the thoracic, lumbar, and sacral spine (T10-S1):

    • degenerative spondylolisthesis with objective evidence of neurologic

    • impairment
      • fracture
      • spinal tumor
      • · failed previous fusion (pseudoarthrosis)
    Device Description

    The SpineVision® Universal Lumbar Intuitive System (U.L.I.S.™ Description System), and Lumbar Universal Minimally Invasive System (LUMIS™ System) instrumentations are composed of cannulated (LUMIS™) and non-cannulated (U.L.I.S.™) pedicle screws and fixation rods (SpineVision UNI-Thread™ rods or LUMIS™ percutaneous rods). Their components can be rigidly assembled in a variety of constructs, each corresponding to the needs and anatomy of a specific patient and are supplied nonsterile. These constructs are assembled using specific instruments. The components of the U.L.I.S.™ and LUMIS™ systems are made of Titanium Ti-6Al-4V ELI complying with ASTM F136 (ISO 5832-3). The components added within this submission include: New reference of LUMIS™ rods (Straight and pre-bent), 12 new instruments for LUMIS™ system, 4 new instruments for U.L.I.S.™ system. The devices provide correction and rigid cannulated. stabilization of the spine during development of solid bone fusion following corrective spine surgery for a number of indications (listed above).

    AI/ML Overview

    The provided text describes a 510(k) submission for a medical device, the SpineVision U.L.I.S.™ and LUMIS™ Pedicle Screw Fixation Systems. This is a submission for an extension of range of products to a previously cleared device (K112607).

    The key takeaway is that no new clinical or additional testing was performed, nor was a new study conducted to prove the device meets acceptance criteria. Instead, SpineVision S.A. claims substantial equivalence to their predicate device based on engineering analysis and design validation/verification.

    Therefore, the requested information regarding acceptance criteria, study data, sample sizes, expert involvement, and ground truth cannot be extracted as it is not present in the provided document. The 510(k) summary explicitly states:

    • "No additional testing has been performed for the added components."
    • "No clinical data has been presented."

    The submission relies on the previously established performance of the predicate device (K112607) and asserts that the new components do not alter the fundamental safety and effectiveness.

    Given this, I cannot fill out the requested table or paragraphs accurately, as the document explicitly states the absence of such new data.

    Ask a Question

    Ask a specific question about this device

    K Number
    K112607

    Validate with FDA (Live)

    Manufacturer
    Date Cleared
    2012-06-07

    (274 days)

    Product Code
    Regulation Number
    888.3070
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    When used for anterior screw fixation or as a posterior, non-pedicle system of the non-cervical spine, the U.L.I.S.TM and LUMISTM systems are indicated for:

    • degenerative disc disease (discogenic back pain with degeneration of the disc confirmed by history and radiographic studies)
    • spondylolisthesis
    • fracture
    • spinal stenosis
    • tumors
    • failed previous fusion (pseudoarthrosis)
      The U.L.I.S.TM and LUMISTM systems are pedicle screw systems indicated for skeletally mature patients who:
    • have severe spondylolisthesis (Grades 3 and 4) at the L5-S1 vertebra;
    • receive fusions using autogenous bone graft only;
    • have the device fixed or attached to the lumbar and sacral spine (L3 to sacrum); and
    • have the device removed after the development of a solid fusion.
      In addition, the U.L.I.S.TM and LUMIS™ systems are pedicle screw systems intended to provide immobilization and stabilization of spinal segments in skeletally mature patients as an adjunct to fusion in the treatment of the following acute and chronic instabilities or deformities of the thoracic, lumbar, and sacral spine (T10-S1):
    • degenerative spondylolisthesis with objective evidence of neurologic impairment
    • fracture
    • spinal tumor
    • failed previous fusion (pseudoarthrosis)
    Device Description

    The SpineVision Universal Lumbar Intuitive System (U.L.I.S.TM System), and Lumbar Universal Minimally Invasive System (LUMISTM System) instrumentations are composed of cannulated (LUMISTM) and non-cannulated (U.L.I.S.TM) pedicle screws and fixation rods (Spine Vision Unithread TM rods). Their components can be rigidly assembled in a variety of constructs, each corresponding to the needs and anatomy of a specific patient. These constructs are assembled using specific instruments. The components of the U.L.E.S.TM and LUMISTM systems are made from ASTM F136 titanium alloy (Ti-6Al-4V ELI) complying with ASTM F136 (ISO 5832-3). The SpineVision Universal Lumbar Intuitive System (U.L.I.S.TM System), and Lumbar Universal Minimally Invasive System (LUMISTM System) instrumentations are manufactured in Titanium alloy complying with ASTM 136. The LUMISTM Pedicle screw system is cannulated. The devices provide correction and rigid stabilization of the spine during development of solid bone fusion following corrective spine surgery for a number of indications (listed above).

    AI/ML Overview

    The manufacturer, Orgenix LLC, submitted a 510(k) Premarket Notification for the SpineVision LUMIS™ Cannulated Polyaxial Pedicle Screw Fixation System and SpineVision U.L.I.S.™ Polyaxial Pedicle Screw Fixation System. The submission refers to non-clinical testing and published retrospective clinical data to support the substantial equivalence claim.

    Here's an analysis of the provided information regarding acceptance criteria and supporting studies:

    1. Table of Acceptance Criteria and Reported Device Performance

    Acceptance Criteria CategorySpecific Criteria/StandardReported Device Performance
    Mechanical TestingASTM F1717 - Standard Test Methods for Spinal Implant Constructs in a Vertebrectomy Model (worse case)Test results indicated substantial performance of the worse case in side-by-side testing with the predicate device.
    ASTM F543 - Standard Specification and Test Methods for Metallic Medical Bone Screws (worse case)Test results indicated substantial performance of the worse case in side-by-side testing with the predicate device.
    ASTM F2193 - Standard Specifications and Test Methods for Components Used in the Surgical Fixation of the Spinal Skeletal System (worse case)Test results indicated substantial performance of the worse case in side-by-side testing with the predicate device.
    ASTM F1798 - Standard Guide for Evaluating the Static and Fatigue Properties of Interconnection Mechanisms and Subassemblies Used in Spinal Arthrodesis Implants (worse case)Test results indicated substantial performance of the worse case in side-by-side testing with the predicate device.
    Sterilization ValidationANSI/AAMI/ISO 17665-1:2006Not explicitly stated "met," but listed as a standard the validation was performed to.
    ANSI/AAMI ST79:2010, A1:2010 and A2:2011Not explicitly stated "met," but listed as a standard the validation was performed to.
    Clinical Equivalence (Pedicle Screws in Pediatric Patients)No specific quantitative criteria are provided for clinical performance; the criterion is established through comparison to predicate devices and demonstration of no new risks.Published retrospective clinical data for similar devices demonstrated pedicle screws posed no new risks to pediatric patients.

    2. Sample Size Used for the Test Set and Data Provenance

    • Mechanical Testing: The document mentions "worse case" testing and "side-by-side testing with the predicate device." However, specific sample sizes (e.g., number of implants tested) for these mechanical tests are not provided.
    • Clinical Data: The clinical data provenance is described as "Published retrospective clinical data for devices similar to the SpineVision Universal Lumbar Intuitive System (U.L.I.S.TM System), and Lumbar Universal Minimally Invasive System (LUMIS™ System) devices."
      • Sample Size: The sample size for this retrospective clinical data is not specified.
      • Country of Origin: The country of origin for the clinical data is not specified.
      • Retrospective or Prospective: Explicitly stated as retrospective.

    3. Number of Experts Used to Establish the Ground Truth for the Test Set and Qualifications of Those Experts

    • This information is not provided in the document. The mechanical testing standards inherently define the "ground truth" through specified methodologies and expected outcomes (e.g., specific load failures, fatigue cycles, etc.). For the retrospective clinical data, the "ground truth" would be the observed safety profile and outcomes in prior use, often established by treating physicians, but the review process for that data is not detailed here.

    4. Adjudication Method for the Test Set

    • This information is not provided. For mechanical testing, adjudication typically refers to the interpretation of test results against established pass/fail criteria. For the retrospective clinical data, the adjudication method of the published studies is not detailed.

    5. If a Multi-Reader Multi-Case (MRMC) Comparative Effectiveness Study was Done

    • No, a Multi-Reader Multi-Case (MRMC) comparative effectiveness study was not done. This type of study is typically associated with diagnostic imaging devices or software where human readers interpret cases with and without AI assistance to measure improvement in diagnostic accuracy. The submitted device is a spinal fixation system, not a diagnostic tool.

    6. If a Standalone (i.e., algorithm only without human-in-the-loop performance) was Done

    • Not applicable. The device is a mechanical implant (pedicle screw fixation system), not an algorithm or software. Therefore, the concept of "standalone performance" in the context of an algorithm does not apply. The device's performance is standalone in the sense that it relies on its physical properties when implanted and a surgeon's skill.

    7. The Type of Ground Truth Used

    • Mechanical Testing: The ground truth is defined by engineering standards and specifications (ASTM F1717, ASTM F543, ASTM F2193, ASTM F1798). These standards establish objective criteria for performance (e.g., force at failure, fatigue life, torsional strength).
    • Clinical Data: The ground truth for the clinical data mentioned is based on patient outcomes and safety profiles observed in prior retrospective studies involving similar devices. This would encompass absence of new risks, stability, and effectiveness in achieving fusion, as documented in clinical records.

    8. The Sample Size for the Training Set

    • Not applicable / Not explicitly provided. This device is a physical implant and not an AI/ML algorithm that requires a "training set" of data in the conventional sense. The design and manufacturing processes are informed by engineering principles, material science, and prior clinical experience, rather than data-driven machine learning training.

    9. How the Ground Truth for the Training Set Was Established

    • Not applicable / Not explicitly provided. As noted above, there is no "training set" for this type of medical device in the context of AI/ML. The "ground truth" for the device's design and engineering is established through fundamental scientific and engineering principles, material properties, and established biomaterial/biomechanical testing methodologies.