Search Filters

Search Results

Found 1 results

510(k) Data Aggregation

    K Number
    K993963

    Validate with FDA (Live)

    Date Cleared
    2000-01-13

    (52 days)

    Product Code
    Regulation Number
    890.3850
    Reference & Predicate Devices
    Predicate For
    N/A
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    For transportation of disabled persons.

    Device Description

    The device consists of a chromed steel frame with cross bars, slung fabric seat and back, fixed or removable armrests, fixed or removable foot/legrests. Front caster wheels for steering, rear push handles for attendant-assisted propulsion, rear drive wheels with handrims for self-propulsion, and lever-style wheel locks.

    AI/ML Overview

    The provided text describes a 510(k) summary for a manual wheelchair and the FDA's clearance letter. It does not contain information about the acceptance criteria or a study proving the device meets those criteria in the context of an AI/ML device. The device described is a physical manual wheelchair, and the 510(k) summary focuses on demonstrating substantial equivalence to predicate devices based on design features and compliance with a flammability test for its fabric, not performance metrics common to AI/ML devices.

    Therefore, I cannot provide the requested information for an AI/ML device based on the given input.

    If the request was intended for a medical device in general, the provided text includes some information relevant to product specifications and a single test:

    1. Table of Acceptance Criteria and Reported Device Performance:

    CriteriaAcceptance / Predicate Value (Invacare Tracer Wheelchair - K935398)Reported Device Performance (Sigma Manual Wheelchair)
    Seat Height20"20"
    Widths14"-22"14"-22"
    Rear Wheels24"24"
    Front Casters8"8"
    Product Weight44 lbs43 lbs
    Weight Limit250 lbs.250 lbs.
    Fabric FlammabilityNFPA 701-89 Flame Resistant Textile and Films test (implied by predicate, explicitly stated for the submitted device)Meets NFPA 701-89 Flame Resistant Textile and Films test

    2. Sample size used for the test set and the data provenance: Not applicable. The "test set" consists of comparing the specifications of one submitted device model to a predicate device and a single fabric flammability test.

    3. Number of experts used to establish the ground truth for the test set and the qualifications of those experts: Not applicable. Specifications like dimensions and weight limits are objective measurements. Fabric flammability is determined by standardized tests, not expert consensus in this context.

    4. Adjudication method (e.g. 2+1, 3+1, none) for the test set: Not applicable. Performance is based on direct measurement and standardized testing.

    5. If a multi reader multi case (MRMC) comparative effectiveness study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance: Not applicable. This is a physical wheelchair, not an AI/ML device.

    6. If a standalone (i.e. algorithm only without human-in-the-loop performance) was done: Not applicable. This is a physical wheelchair, not an AI/ML device.

    7. The type of ground truth used (expert consensus, pathology, outcomes data, etc):
    * For physical dimensions and weight: Direct measurement/specification.
    * For fabric flammability: Results from a standardized ignitability test (NFPA 701-89).

    8. The sample size for the training set: Not applicable. This is not an AI/ML device.

    9. How the ground truth for the training set was established: Not applicable. This is not an AI/ML device.

    Ask a Question

    Ask a specific question about this device

    Page 1 of 1