Search Filters

Search Results

Found 3 results

510(k) Data Aggregation

    K Number
    K230241

    Validate with FDA (Live)

    Device Name
    Jumong General
    Date Cleared
    2023-02-23

    (24 days)

    Product Code
    Regulation Number
    892.1680
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    N/A
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The Jumong General is intended for use by a qualified/trained doctor or technician on both adult and pediatric subjects for taking diagnostic radiographic exposures of the skull, spinal column, extremities, and other body parts. Applications can be performed with the patient sitting, standing, or lying in the prone or supine position. Not for mammography.

    Device Description

    This device represents a combination of an already cleared solid state digital x-ray acquisition panel with software and diagnostic x-ray components required to make a complete system. Film cassettes may be employed in place of the x-ray generator has been changed to a Delta Electronics Delta DMP 100R The collimator has been changed to a Fairy Medical Electronics model CRUX FR04. The tubehead has been changed to a Hangzhou Kailong Medical Instruments Co., Ltd H1074X. The system complies with the CDRH Radiological Health performance standard in the Code of Federal Regulations, as well as the voluntary IEC standards IEC 60601-1 and IEC 60601-1-2.

    AI/ML Overview

    The provided text is a 510(k) Pre-market Notification document for the "Jumong General" stationary x-ray system. This document is a submission to the FDA demonstrating that a new device is substantially equivalent to a legally marketed predicate device.

    It's important to understand that in this context, "acceptance criteria" and "study that proves the device meets the acceptance criteria" refer to the demonstration of substantial equivalence, primarily through non-clinical performance testing and comparison to an established predicate device, rather than a clinical study with human-in-the-loop performance measurement of an AI algorithm.

    The document states:

    • "5. Safety and Effectiveness, comparison to predicate device. This combination device has the same indications for use and very similar technological characteristics as the predicate device, and employs already 510(k) cleared digital panels and software."
    • "No software modifications were made to the imaging chain."
    • "8. Summary of clinical testing: Not applicable."

    This clearly indicates that this submission does not involve an AI algorithm that requires a separate performance study with human readers or standalone algorithm performance assessment. The device is a conventional x-ray imaging system, albeit with some updated components compared to its predicate.

    Therefore, many of the requested points related to AI performance, such as MRMC studies, standalone AI performance, ground truth establishment for AI training/testing, and expert adjudication, are not applicable to this specific submission.

    However, I can still interpret how the concept of "acceptance criteria" and "proof" apply to this device based on the provided text, focusing on its non-clinical performance and substantial equivalence demonstration.


    Acceptance Criteria and Study for Jumong General X-Ray System

    Given that the Jumong General is a stationary x-ray system (Product Code: KPR, MQB) and not an AI-powered diagnostic device, the "acceptance criteria" and "proof" focus on demonstrating substantial equivalence to a previously cleared predicate device (K150816, Jumong Series Stationary Radiographic System). This is achieved primarily through non-clinical performance testing, safety standards compliance, and direct comparison of functional characteristics. The document explicitly states "No software modifications were made to the imaging chain," and "Clinical testing: Not applicable."

    The "acceptance criteria" for demonstrating substantial equivalence primarily revolve around meeting recognized performance standards, electrical safety, EMC compliance, and demonstrating comparable image quality and intended use to the predicate device.

    1. Table of Acceptance Criteria and Reported Device Performance

    Acceptance Criteria CategorySpecific Acceptance Criteria (Demonstrated Equivalency)Reported Device Performance / Proof
    Intended UseIdentical Indications for Use as the predicate device.UNCHANGED from K150816, Jumong Series Stationary Radiographic System: "Intended for use by a qualified/trained doctor or technician on both adult and pediatric subjects for taking diagnostic radiographic exposures of the skull, spinal column, chest, abdomen, extremities, and other body parts. Applications can be performed with the patient sitting, standing, or lying in the prone or supine position. Not for mammography." (page 4, section 3 & page 5, "Intended Use" row)
    Technological CharacteristicsFunctional equivalence of modified components (Generator, Collimator, Tubehead) to predicate components, while retaining existing cleared digital panels and software.The device combines an "already cleared solid state digital x-ray acquisition panel with software and diagnostic x-ray components." (page 4, section 4). The new components are: - Generator: Delta Electronics DMP 100R (same kVp range as CPI CMP 200 DR predicate) - Collimator: Fairy Medical Electronics CRUX FR04 (changed from Ralco Model R225) - Tubehead: Hangzhou Kailong Medical Instruments Co., Ltd H1074X (changed from Varian RAD14) Digital Panel Models, Image acquisition panel specifications, DICOM, Image acquisition software, and Power Source are all SAME as predicate. (page 5, comparison chart). Conclusion: "This combination device has the same indications for use and very similar technological characteristics as the predicate device, and employs already 510(k) cleared digital panels and software." (page 4, section 5)
    Safety & Performance StandardsCompliance with relevant US Radiation Safety Performance Standards and IEC standards for medical electrical equipment.- Conforms to the US Performance Standard. (page 6, section 7) - New generator complies with: IEC 60601-2-54:2009+A1+A2, IEC 60601-1:2005+Corrigendum 1+Corrigendum 2+A1, IEC 60601-1-3:2008+A1, and IEC 60601-1-6:2010+A1. (page 6, section 7) - EMC testing complies with IEC 60601-1-2:2014. (page 6, section 7) - New collimator tested for compliance with EN/IEC 60601-2-54 for radiation leakage. (page 6, section 7) - New tubehead tested to IEC 60613:2010 and IEC 60336:2005. (page 6, section 7) - "Every unit is tested for electrical safety, input power, display of operation and exposure factors, collimator operation, reproducibility, and accuracy." (page 6, section 7)
    Image QualityImage quality should be diagnostically acceptable and comparable to the predicate device."Test images were acquired which showed excellent diagnostic quality." (page 6, section 7)
    Risk AnalysisAssessment of risks associated with modifications and demonstration of acceptable risk profile."A risk analysis was performed with regard to the modifications. No software modifications were made to the imaging chain." (page 6-7, section 7) The conclusion states the device is "as safe and effective as the predicate device." (page 7, section 9)

    As this is a conventional X-ray system submission and not an AI/CADe device, the following points are largely "Not Applicable."

    2. Sample size used for the test set and the data provenance

    • Not Applicable in the traditional sense of a clinical test set for an AI algorithm. The "test set" here refers to the physical system undergoing non-clinical verification and validation tests. The document references "test images" acquired for image quality assessment, but the sample size or specific provenance of these images is not detailed as it would be for a clinical AI study. The testing is described as non-clinical ("integration and image quality testing").

    3. Number of experts used to establish the ground truth for the test set and the qualifications of those experts

    • Not Applicable. Ground truth, in the context of diagnostic accuracy for AI, is not relevant here. The "diagnostic quality" of images was assessed, presumably by qualified personnel, but this is a standard engineering and quality assurance assessment for image generators, not an AI ground truth establishment process.

    4. Adjudication method (e.g., 2+1, 3+1, none) for the test set

    • Not Applicable. This pertains to clinical AI studies for diagnostic accuracy.

    5. If a multi-reader multi-case (MRMC) comparative effectiveness study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance

    • Not Applicable. This is specific to AI-assisted diagnostic devices. The document explicitly states "Summary of clinical testing: Not applicable."

    6. If a standalone (i.e. algorithm only without human-in-the-loop performance) was done

    • Not Applicable. This is specific to the performance of an AI algorithm. The device is a hardware x-ray system, and no AI algorithm's standalone performance is being evaluated.

    7. The type of ground truth used (expert consensus, pathology, outcomes data, etc.)

    • Not Applicable. Ground truth for diagnostic accuracy is not relevant here as it's a hardware device demonstrating fundamental imaging capability and safety, not a diagnostic interpretation tool.

    8. The sample size for the training set

    • Not Applicable. There is no AI algorithm being trained for this device as per the submission details ("No software modifications were made to the imaging chain").

    9. How the ground truth for the training set was established

    • Not Applicable. As there is no AI algorithm being trained by the applicant, this point is not relevant.
    Ask a Question

    Ask a specific question about this device

    K Number
    K222080

    Validate with FDA (Live)

    Date Cleared
    2022-10-06

    (83 days)

    Product Code
    Regulation Number
    892.1650
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The Garion is intended to be used and operated by: adequately trained, qualified and authorized health care professionals who have full understanding of the safety information and emergency procedures as well as the capabilities and functions of the device. The device is used for radiological guidance and visualization during diagnostic, interventional and surgical procedures on all patients, except neonates (birth to one month), within the limits of the device is to be used in health care facilities both inside and outside the operating room, sterile as well as non-sterile environment in a variety of procedures.

    Device Description

    GARION is mobile fluoroscopy system is designed to provdie fluoroscopic and spot-film images of thepatient during diagnostic, surgical procedures. This device is a digital X-ray radiographic equipment that consists of high voltage generator, X-ray control unit, X-ray tube unit, Collimator, image processing unit. The image processing unit consists of medical image detector, power supply, medical image collecting unit and relevant software.

    AI/ML Overview

    The provided text describes a 510(k) premarket notification for a medical device called "Garion", an image-intensified fluoroscopic x-ray system. The document focuses on demonstrating substantial equivalence to a legally marketed predicate device, "Zenition 70".

    Here's an analysis of the acceptance criteria and study information based on the provided text:

    1. Table of Acceptance Criteria and Reported Device Performance:

    The document focuses on demonstrating substantial equivalence to a predicate device rather than defining specific performance acceptance criteria for the Garion device against a set of quantitative metrics. The "performance" is implicitly assessed through a comparison of technical characteristics to the predicate.

    Acceptance Criteria (Implicit from Substantial Equivalence Claim)Reported Device Performance (Comparison to Predicate: Zenition 70 K183040)
    Indications for UseSame as predicate
    X-ray Tube Anode TypeRotating Anode (Same as predicate)
    X-ray Tube Anode Target Angle10° (Same as predicate)
    X-ray Tube Focal Size0.3/0.6 (Same as predicate)
    Fluoroscopic Mode kV range40-125 kV (Similar, slightly higher peak kVp than predicate's 40-120 kV)
    Fluoroscopic Mode mA range0.1-100 mA (Similar, slightly higher mA than predicate's 0.5-60 mA)
    Pulse FluoroYES (Same as predicate)
    ABS functionYES (Same as predicate)
    FPD ScintillatorCesium Iodide (Same as predicate)
    FPD Detector typeAmorphous silicon detector (Same as predicate)
    FPD Active detector size228.6 mm x 228.6 mm (Similar, slightly larger image than predicate's 207x207 mm)
    FPD Total pixel matrix1024x1024 (Similar to predicate's 1344x1344)
    FPD Pixel pitch205 μm (Similar to predicate's 154 μm)
    FPD A/D Conversion16 bit (Same as predicate)
    FPD MTF (1.0 lp/mm)0.64 (Similar, slightly better than predicate's 0.59)
    FPD DQE (0 lp/mm)0.77 (Same as predicate)
    SID980mm (Similar to predicate's 993mm)
    C-arm Rail Rotation Range±180° (Similar to predicate's ±200°)
    Linear FR-arm Movement Range200mm (Same as predicate)
    Linear T-arm Movement Range400mm (Similar to predicate's 490 mm)
    Swing-arm Rotation Range±15° (Similar, slightly better than predicate's ±10°)
    Collimator ControlMotor control / rotation (Same as predicate)

    The acceptance criterion, in this context, is that the Garion device's technological characteristics are substantially equivalent to the predicate device, implying similar safety and effectiveness. The reported performance is the direct comparison of these characteristics.

    2. Sample Size Used for the Test Set and Data Provenance:

    The document explicitly states: "9. Summary of clinical testing: Not required for a finding of substantial equivalene." This indicates that no clinical test set was used to evaluate the device's performance against specific acceptance criteria. The evaluation relies on comparing the technical specifications of the new device to the predicate device and adherence to relevant IEC standards.

    3. Number of Experts Used to Establish the Ground Truth for the Test Set and Qualifications of Those Experts:

    Since no clinical test set was used, there were no experts establishing ground truth for a test set.

    4. Adjudication Method for the Test Set:

    Not applicable, as no clinical test set was used.

    5. If a Multi-Reader Multi-Case (MRMC) Comparative Effectiveness Study Was Done:

    No, an MRMC comparative effectiveness study was not done. The document states that clinical testing was not required for substantial equivalence.

    6. If a Standalone (i.e., algorithm only without human-in-the-loop performance) Was Done:

    The "Garion" is an X-ray system, not an AI algorithm. Therefore, the concept of "standalone (algorithm only)" performance is not applicable in the same way as it would be for a pure software device. The evaluation is of the hardware and integrated software for image acquisition and display.

    7. The Type of Ground Truth Used:

    The "ground truth" for the substantial equivalence claim is effectively the established safety and effectiveness of the legally marketed predicate device (Zenition 70), supported by the device's compliance with applicable performance standards (IEC and FDA Radiation Safety Performance Standard). The comparison of technical specifications aims to show that the Garion device is sufficiently similar to the predicate to assume similar safety and effectiveness.

    8. The Sample Size for the Training Set:

    The concept of a "training set" is typically associated with machine learning or AI algorithms. Since this submission is for an X-ray system and does not mention any AI components requiring supervised learning, there is no training set in the conventional sense.

    9. How the Ground Truth for the Training Set Was Established:

    Not applicable, as there is no mention of a training set or AI algorithms requiring ground truth establishment.

    Ask a Question

    Ask a specific question about this device

    K Number
    K150816

    Validate with FDA (Live)

    Device Name
    Jumong Series
    Date Cleared
    2015-05-08

    (42 days)

    Product Code
    Regulation Number
    892.1680
    Age Range
    2 - 120
    Predicate For
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The Jumong Series Stationary Radiographic System is intended for use by a qualified/trained doctor or technician on both adult and pediatric subjects for taking diagnostic radiographic exposures of the skull, spinal column, chest. abdomen, extremities, and other body parts. Applications can be performed with the patient sitting, standing, or lying in the prone or supine position. Not for mammography.

    Device Description

    This device represents a new combination of an already cleared solid state digital x-ray acquisition panel with software and diagnostic x-ray compnents required to make a complete system. Film cassettes may be employed in place of the digital panel. The purchaser can select from one of four configurations. The x-ray generator is a CPI CMP 200DR. The x-ray tubes are supplied by Varian (RAD-14), and the collimator is the Ralco R225 ACS DHHS. The system complies with the CDRH Radiological Health performance standard in the Code of Federal Regulations, as well as the voluntary IEC standards IEC 60601-1 and IEC 60601-1-2. All major components are either UL or CSA listed.

    AI/ML Overview

    The provided text is a 510(k) summary for the "Jumong Series Stationary Radiographic System." It primarily focuses on demonstrating substantial equivalence to a predicate device rather than providing specific acceptance criteria and performance data from a standalone study. Therefore, much of the requested information cannot be extracted directly from this document.

    Here's what can be gathered:

    1. Table of Acceptance Criteria and Reported Device Performance:

    The document does not explicitly state quantitative acceptance criteria for image quality or clinical performance that the device was tested against. Instead, it relies on demonstrating that the device meets general safety and performance standards, and that its components (like digital panels) are previously cleared. The "performance" assessment is framed as "bench, safety test, and software validation documentation indicates that the new device is as safe and effective as the predicate device" and that the device "conforms to US Performance Standards" and various IEC/NEMA voluntary standards.

    CharacteristicAcceptance Criteria (Not explicitly stated as quantitative targets)Reported Device Performance
    Overall PerformanceSafe and effective as the predicate device. Conforms to US Performance Standards and listed voluntary international standards."Results of a review of bench, safety test, and software validation documentation indicates that the new device is as safe and effective as the predicate device. The device conforms to US Performance Standards..." and lists compliance with standards like IEC 60601-1 (Safety of Electrical Medical Equipment), IEC 60601-1-2 (Electromagnetic Compatibility), IEC 60601-1-3 (Radiation protection), IEC 60601-1-6 (Usability), IEC 60601-2-28 (X-ray tube assemblies), IEC 60601-2-54 (X-ray equipment for radiography), IEC 62366 (Usability engineering), and NEMA PS 3.1 - 3.18 (DICOM).
    Image QualityNot explicitly defined with quantitative metrics, but inferred to be comparable to cleared digital panels.Clinical images were provided; these images were not necessary to establish substantial equivalence but "provide further evidence in addition to the laboratory performance data to show that the complete system works as intended." The digital panels used are previously 510(k) cleared.
    Intended UseIdentical to the predicate device.The Jumong Series has "identical indications for use" as the predicate device.

    2. Sample Size Used for the Test Set and the Data Provenance:

    The document mentions that "Clinical images were provided," but does not specify the sample size, data provenance (e.g., country of origin), or whether they were retrospective or prospective. It explicitly states these images "were not necessary to establish substantial equivalence."

    3. Number of Experts Used to Establish the Ground Truth for the Test Set and the Qualifications of Those Experts:

    This information is not provided in the document. The phrase "clinical images were provided" suggests some form of evaluation but no details on expert involvement or ground truth establishment for a test set.

    4. Adjudication Method:

    This information is not provided in the document.

    5. Multi-Reader Multi-Case (MRMC) Comparative Effectiveness Study:

    No MRMC comparative effectiveness study is mentioned in the document. The submission focuses on substantial equivalence based on technical characteristics and safety/performance standards, rather than a clinical trial comparing human reader performance.

    6. Standalone Performance Study:

    The document implies that images were used to show the "complete system works as intended," suggesting some form of standalone evaluation. However, it does not describe a formal standalone performance study with specific metrics, acceptance criteria, or a detailed methodology. The "non-clinical testing" section primarily covers integration, bench, safety, and software validation.

    7. Type of Ground Truth Used:

    The document does not explicitly state the type of ground truth used for any clinical image evaluation, given that the clinical images were "not necessary to establish substantial equivalence."

    8. Sample Size for the Training Set:

    This information is not applicable as the document describes a device (X-ray system), not an AI algorithm that would typically require a training set.

    9. How the Ground Truth for the Training Set Was Established:

    This information is not applicable as the document describes a device (X-ray system), not an AI algorithm.

    Ask a Question

    Ask a specific question about this device

    Page 1 of 1