510(k) Data Aggregation

    K Number
    K190406

    Validate with FDA (Live)

    Date Cleared
    2020-02-20

    (364 days)

    Product Code
    Regulation Number
    872.3640
    Panel
    Dental
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    N/A
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    SDS2.2 dental implants are intended as artificial replacements to be placed in the human upper or lower jaw to provide anchor points for the prosthetic restoration. They are indicated for transgingival healing. The implants are indicated for immediate loading when good primary stability is achieved and with appropriate occlusal loading.

    SDS2.2 standard implant posts and SDS2.2 standard screws are industrially manufactured prosthetic components. They are connected to the SDS2.2 dental implant and enable the fixation of prosthetic restorations.

    Device Description

    SDS2.2 dental implants are a two-piece implant system to fit a synthetic root replacement into the human jaw. The implants are made of Y-TZP (yttria-stabilized tetragonal zirconia poly-crystal) zirconium dioxide ceramics in accordance with ISO 13356. The SDS2.2 dental implant system with its included components is used to fix the prosthetic restoration and is suitable for patients with an intolerance to metal. The implants have a self-tapping Dynamic Thread® in the implant for good primary stability. Its bone-condensing section has a 2.5x thread depth. The upper section of the implant has a micro-thread. The outer surface of the SDS2.2 implants is abrasive blasted for good osseointegration, the implant shoulder is machined. SDS2.2 implants are provided in different length/ diameter combinations and with 2 different shoulder designs (standard shoulder and oval shoulder). The implants are provided sterile in sterile packaging and are intended for single use. The sterile packaging also includes the SDS2.2 cover screw made of PEEK (Polyetheretherketone), which can be used to protect the implant interface during the healing phase up to 180 days. SDS2.2 standard implant posts are made of Y-TZP and are attached to SDS 2.2 dental implants by cementation. During cementation, the implant posts are screw retained with the SDS2.2 standard PEEK screw to ensure implant post is fixed at final position. The SDS2.2 standard PEEK screw is removed before the cement is completely cured. After attachment to the SDS2.2 implant, standard implant posts enable cementation of prosthetic restorations. SDS2.2 standard implant posts are available in different designs. The SDS2.2 standard implant posts and SDS2.2 standard PEEK screws are provided non-sterile.

    AI/ML Overview

    The document is a 510(k) premarket notification for the SDS2.2 dental implant system. It focuses on demonstrating substantial equivalence to previously cleared predicate devices. The information provided heavily emphasizes physical and mechanical properties, material composition, manufacturing processes, and sterilization validation rather than AI/ML algorithm performance.

    Therefore, many of the requested bullet points for describing AI/ML device acceptance criteria and study details cannot be directly answered from this document. The document describes a traditional medical device (dental implant) and its non-clinical testing for safety and effectiveness.

    Here's an analysis based on the provided document, addressing what can be inferred and stating what cannot:

    1. A table of acceptance criteria and the reported device performance:

    The document doesn't present acceptance criteria in a formal table with values for an AI/ML algorithm's performance metrics (e.g., sensitivity, specificity, AUC). Instead, it discusses the device meeting "existing requirements and acceptance criteria" based on various regulatory standards and non-clinical tests.

    Acceptance Criteria Category/StandardReported Device Performance (Summary)
    BiocompatibilityComponents subjected to biological evaluation per ISO 10993-1, including cytotoxicity (ISO 10993-5). Demonstrated biocompatibility through tests regarding Cytotoxicity, Bioburden, and Endotoxins. Methods for manufacturing, cleaning, and sterilization are established and validated.
    Performance TestingRisk analysis per ISO 14971 guided performance tests. Successful fatigue testing (ISO 14801), surface investigation (scanning electron microscope), and laboratory testing for extractable cytotoxic substances, pyrogenicity, and total organic carbon. Meets existing requirements and acceptance criteria like predicate devices.
    Sterilization Validation & Shelf LifeSterilization validated per ISO 11137-2. Proved minimal sterilization dose of 25 Gy leading to SAL of ≤ 10^-6. Packaging system validated per ISO 11607-2 for performance during sterilization and storage up to 5 years (accelerated aging). Non-sterile products' end-user sterilization validated per ISO 17665-1.
    Compliance with Applicable StandardsMeets all requirements of listed standards (e.g., ISO 14801, ISO 7405, ISO 13356, ISO 10993 series, ISO 14971, ISO 15223-1, ISO 11607 series, ISO 11137 series).

    2. Sample size used for the test set and the data provenance:

    • Test Set Sample Size: Not applicable. This document describes testing for a physical medical device (dental implant), not an AI/ML algorithm. The "test set" in this context refers to physical implants subjected to various lab tests (e.g., fatigue testing, material analysis). The sample sizes for these specific physical tests are not provided in this summary document.
    • Data Provenance: Not applicable for AI/ML dataset. The "data" refers to the results of bench testing and physical-chemical characterization of the implant. There is no mention of country of origin or retrospective/prospective human data.

    3. Number of experts used to establish the ground truth for the test set and the qualifications of those experts:

    Not applicable. Ground truth, in the context of AI/ML, refers to human annotations or confirmed diagnoses used to train and evaluate an algorithm. For a dental implant, "ground truth" is established through engineering and material science standards and confirmed by accredited lab testing, not by expert physicians interpreting images or data for AI.

    4. Adjudication method (e.g., 2+1, 3+1, none) for the test set:

    Not applicable. Adjudication methods are typically used in clinical studies involving multiple human readers to resolve discrepancies in annotations or diagnoses for AI/ML ground truth. This is not relevant to the physical testing of a dental implant.

    5. If a multi reader multi case (MRMC) comparative effectiveness study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance:

    No. An MRMC study is relevant for evaluating the impact of AI assistance on human performance in diagnostic tasks. This document describes a physical medical device and its non-clinical performance, not an AI/ML diagnostic aid.

    6. If a standalone (i.e. algorithm only without human-in-the-loop performance) was done:

    No. This concept is specific to AI/ML algorithm testing. The device is a physical implant; its "performance" is inherently "standalone" in mechanical terms, but it's not an algorithm.

    7. The type of ground truth used (expert consensus, pathology, outcomes data, etc.):

    The "ground truth" for evaluating this device's performance is based on established engineering and material standards for dental implants (e.g., ISO 14801 for fatigue, ISO 10993 for biocompatibility) and the successful outcome of physical bench tests and material analyses. It's not based on clinical imaging, pathology, or outcomes data in the sense used for AI/ML.

    8. The sample size for the training set:

    Not applicable. There is no AI/ML training set discussed in this document.

    9. How the ground truth for the training set was established:

    Not applicable. There is no AI/ML training set discussed in this document.

    Ask a Question

    Ask a specific question about this device

    K Number
    K181953

    Validate with FDA (Live)

    Date Cleared
    2019-11-20

    (485 days)

    Product Code
    Regulation Number
    872.3640
    Panel
    Dental
    Age Range
    12 - 120
    Reference & Predicate Devices
    Predicate For
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    SDS 1.2 dental implants are intended as artificial replacements to be placed in the human upper or lower jaw to provide anchor points for the prosthetic restoration. They are indicated for transgingival healing. The implants are indicated for immediate loading when good primary stability is achieved and with appropriate occlusal loading. SDS1.2_33xx implants are recommended as single-tooth implant for upper lateral and lower incisors for fixed prosthetic restorations only.

    SDS 1.2 healing caps-disc, SDS .2 temporary caps and SDS 1.2 standard screws are industrially manufactured prosthetic components. They are connected to the SDS1.2 dental implant and enable the production/ fixation of long-term temporary restorations or protect the implant during healing phase for up to 180 days.

    Device Description

    SDS1.2 dental implants are a one-piece implant system to fit a synthetic root replacement into the human jaw. The implants are made of Y-TZP (yttria-stabilized tetragonal zirconia poly-crystal) zirconium dioxide ceramics in accordance with ISO 13356. The SDS1.2 dental implants are used to fix the prosthetic restoration and are suitable for patients with an intolerance to metal. The implants have a self-tapping Dynamic Thread® in the implant for good primary stability. Its bone-condensing section has a 2.5x thread depth. The upper section of the implant has a micro-thread. The outer surface of the SDS1.2 implants is abrasive blasted for good osseointegration, the implant shoulder is machined. SDS1.2 implants are provided in different length/ diameter combinations and with 2 different shoulder designs. The implants are provided sterile in sterile packaging and are intended for single use. SDS1.2 dental implants must not be re-sterilized or disinfected either. When delivered, all SDS1.2 dental implants are mounted with the disposable SDS1.2 insertion tool.

    Temporary restorations can be produced either individually or by using the prefabricated SDS1.2 Temporary cap as basis. The SDS1.2 Temporary caps are made of PEEK (polyether ether ketone). The SDS1.2 Temporary cap may only be used for screw-retaining temporary restorations with SDS1.2 standard screw (SDS1.2_SS-T) and must not be cemented. The SDS1.2 Temporary caps are provided non-sterile and must be cleaned, disinfected and sterilized according to the instructions given in the "Instructions for use" document. They are intended for single-use and can stay for a maximum period of 180 days in situ.

    SDS1.2 Healing caps-disc may be used to protect the dental implant. The Healing caps-disc are made of Y-TZP (yttria-stabilized tetragonal zirconia poly-crystal) zirconium dioxide ceramics in accordance with ISO 13356. They can be fixed by screw-retaining with SDS1.2 standard titanium screws. The SDS1.2 Healing caps-disc are provided non-sterile and must be cleaned, disinfected and sterilized according to the instructions given in the "Instructions for use" document. They are intended for single-use and can stay for a maximum period of 180 days in situ.

    AI/ML Overview

    The SDS1.2 dental implant system's acceptance criteria and the study proving it meets them are described below based on the provided document.

    1. Table of Acceptance Criteria and Reported Device Performance

    The acceptance criteria for the SDS1.2 dental implant system are primarily based on demonstrating substantial equivalence to predicate devices through various tests and compliance with established standards. The reported device performance indicates that these criteria have been met.

    Acceptance Criteria CategorySpecific Criteria/TestsReported Device Performance
    BiocompatibilityCompliance with ISO 10993-1 and ISO 10993-5 (cytotoxicity).Components subjected to biological evaluation per ISO 10993-1, including cytotoxicity tests per ISO 10993-5. Identical materials with comparable reference devices for type and duration of patient contact. Biocompatibility demonstrated by tests for cytotoxicity, bioburden, and endotoxins by an accredited laboratory.
    Performance TestingStability, surface structure analysis, fatigue testing (ISO 14801), and laboratory tests for extractable cytotoxic substances, pyrogenicity, and total organic carbon.Fatigue testing conducted in accordance with ISO 14801. Surface investigation performed with scanning electron microscope. Laboratory testing for extractable cytotoxic substances, pyrogenicity, and total organic carbon planned and performed as per FDA Guidance. Testing results analyzed and evaluated, demonstrating the SDS1.2 Dental implants meet existing requirements and acceptance criteria like the predicate devices.
    Sterilization ValidationCompliance with ISO 11137-2 for device sterilization.Minimal sterilization dose of 25 Gv proved, leading to a sterility assurance level (SAL) of ≤ 10^-6 as required by DIN EN 556-1.
    Packaging ValidationCompliance with ISO 11607-1 and ISO 11607-2.Packaging system performance validated per ISO 11607-1 and ISO 11607-2. Validation results demonstrated packaging system fulfilled requirements during sterilization and storage for up to 5 years (accelerated aging). For non-sterile products (healing and temporary caps), end-user sterilization validation performed according to ISO 17665-1, confirming cleaning, disinfection, and sterilization processes meet defined results.
    Material StandardsCompliance with ISO 13356 for Y-TZP zirconia ceramics.Implants are made of Y-TZP material in accordance with ISO 13356. Healing caps-disc also made of Y-TZP (ISO 13356).
    General ComplianceCompliance with all applicable standards.SDS 1.2 Dental implants meet all requirements of the applicable standards listed (e.g., ISO 7405, ISO 14971, ISO 15223-1, ISO 11137-1).
    Substantial EquivalenceDemonstrating equivalence to predicate devices in intended use, technological characteristics, packaging, sterilization, and design.The subject device is stated to be "substantially equivalent to the selected predicate devices" in terms of intended use, technological characteristics, packaging, sterilization, and design key elements. Minor differences are covered by reference devices and do not raise new questions of safety and effectiveness.

    2. Sample size used for the test set and the data provenance

    The document indicates that non-clinical testing was performed, including biocompatibility, performance testing (e.g., fatigue testing), sterilization validation, and packaging validation. However, specific sample sizes for these tests are not explicitly stated. The document only mentions that "the testing results were analyzed and evaluated" and that testing was "planned and performed."

    The document also explicitly states:

    • "No animal testing"
    • "No clinical testing"

    Therefore, there is no information on sample sizes from human, animal, or clinical trials. The provenance of the data is implicitly from laboratory testing conducted as part of the regulatory submission process, likely by the manufacturer or accredited testing facilities. The specific country of origin for the non-clinical test data is not provided, though the manufacturer is based in Switzerland.

    3. Number of experts used to establish the ground truth for the test set and the qualifications of those experts

    Not applicable. This device is not an AI/ML device that requires human expert adjudication for ground truth establishment. The ground truth for performance evaluation is established through objective physical and chemical test methods and compliance with established industry standards.

    4. Adjudication method (e.g., 2+1, 3+1, none) for the test set

    Not applicable, as this is not an AI/ML device requiring human adjudication or ground truth establishment based on expert consensus for a test set.

    5. If a multi-reader multi-case (MRMC) comparative effectiveness study was done, if so, what was the effect size of how much human readers improve with AI vs without AI assistance

    Not applicable. The SDS1.2 dental implant system is a physical medical device, not an AI/ML diagnostic or assistive tool. No MRMC study was conducted.

    6. If a standalone (i.e. algorithm only without human-in-the loop performance) was done

    Not applicable. The SDS1.2 dental implant system is a physical medical device, not an algorithm.

    7. The type of ground truth used (expert consensus, pathology, outcomes data, etc.)

    The "ground truth" for the device's performance is established through adherence to recognized international standards and validated laboratory test methods. This includes:

    • Biocompatibility testing (ISO 10993 series)
    • Mechanical performance testing (e.g., fatigue testing per ISO 14801)
    • Material standards compliance (e.g., ISO 13356 for Y-TZP)
    • Sterilization and packaging validation standards (ISO 11137, ISO 11607)
    • Comparison to technological characteristics of predicate devices that have already demonstrated safety and effectiveness.

    8. The sample size for the training set

    Not applicable. As a physical medical device, there is no "training set" in the context of AI/ML or statistical model development. The design and manufacturing processes are validated, and the device's performance is confirmed through non-clinical testing.

    9. How the ground truth for the training set was established

    Not applicable. There is no training set for this physical medical device.