Search Filters

Search Results

Found 2 results

510(k) Data Aggregation

    K Number
    K140827

    Validate with FDA (Live)

    Manufacturer
    Date Cleared
    2015-09-30

    (547 days)

    Product Code
    Regulation Number
    864.7470
    Reference & Predicate Devices
    Predicate For
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The SD A1cCare System is a reflectometry immunoassay used for the quantitative measurement of glycated hemoglobin (%HbA1c) levels in fresh fingerstick capillary blood or venous whole blood samples. This system is intended for clinical laboratory and point-of-care use to monitor long term glycemic control of persons previously diagnosed with diabetes. This test is not for screening or diagnosis of diabetes.

    The SD A1cCare Spoit Type Test Kit is part of the SD A1cCare System. It includes the test panel that receives the blood sample and is used with the SD A1cCare Analyzer for the quantitative measurement of glycated hemoglobin (HbA1c) levels in fresh fingerstick capillary or venous whole blood samples. The system is intended for clinical laboratory and point-of-care use to monitor long term glycemic control in persons previously diagnosed with diabetes. This test is not for screening or diagnosis of diabetes.

    The SD HbA1c Control Set (Level 1, Level 2) and SD HbA1c Control Level M are intended for use as quality control materials for the SD A1cCare System.

    Device Description

    The SD A1cCare System is a reflectometry immunoassay used for the quantitative measurement of glycated hemoglobin (HbA1c) levels in fresh capillary or venous whole blood samples. It is intended for professional use.

    The SD HbA1c Control Set is intended for use as quality control materials for the SD A1cCare System.

    The SD A1cCare System include the analyzer, analyzer check strip, DC power adapter, immunoassay test panels, lot-specific calibration code chips, and control set.

    AI/ML Overview

    Here's a breakdown of the acceptance criteria and study information for the SD A1cCare System, based on the provided text:

    1. Table of Acceptance Criteria and Reported Device Performance

    The document explicitly states that "All testing met acceptance criteria," but it does not provide a table with specific numerical acceptance criteria alongside the reported device performance for each test. Instead, it lists the types of tests conducted.

    To provide a tabular format, I will extract the types of tests mentioned under "Functional and Safety Testing" and indicate that the results met unstated acceptance criteria.

    Acceptance Criteria CategoryReported Device Performance
    NGSP certificationMet acceptance criteria
    Accuracy method comparisonMet acceptance criteria
    LinearityMet acceptance criteria
    PrecisionMet acceptance criteria
    Comparison of Spoit Type test kit performanceMet acceptance criteria
    Hematocrit rangeMet acceptance criteria
    InterferencesMet acceptance criteria
    Hemoglobin variantsMet acceptance criteria
    Total hemoglobinMet acceptance criteria
    AltitudeMet acceptance criteria
    Testing timeMet acceptance criteria
    Operating temperature rangeMet acceptance criteria
    Optimal sample and mixture volumeMet acceptance criteria
    AnticoagulantsMet acceptance criteria
    Sample collection and preparationMet acceptance criteria
    Stability of blood samplesMet acceptance criteria
    VibrationMet acceptance criteria
    Temperature and humidityMet acceptance criteria
    EMC and electrical safety testingMet acceptance criteria
    Shelf-life testingMet acceptance criteria
    Software verification and validationMet acceptance criteria

    2. Sample Sizes Used for the Test Set and Data Provenance

    The document mentions "a user study clinical evaluation was conducted comparing home user results against a reference method." However, it does not specify the sample size for this test set nor the specific country of origin for the data. It implies the data is prospective, gathered from the user study.

    For other functional and safety tests, no specific sample sizes are provided.

    3. Number of Experts Used to Establish Ground Truth for the Test Set and Qualifications

    The document does not provide information on the number or qualifications of experts used to establish ground truth. It states "comparing home user results against a reference method," but the nature of this reference method and the involvement of experts in its establishment or application are not detailed.

    4. Adjudication Method for the Test Set

    The document does not specify an adjudication method. It only mentions a comparison against a "reference method."

    5. Multi-Reader Multi-Case (MRMC) Comparative Effectiveness Study

    A Multi-Reader Multi-Case (MRMC) comparative effectiveness study was not explicitly mentioned or described. The device is an immunoassay system designed for quantitative measurement, not an imaging or diagnostic aid typically assessed via MRMC studies. The "user study clinical evaluation" compared home user results to a reference method, which is different from an MRMC study assessing human reader improvement with AI assistance.

    6. Standalone (Algorithm Only Without Human-in-the-Loop Performance)

    Yes, the studies described are indicative of standalone performance of the device. The "SD A1cCare System" is an automated reflectometry immunoassay system. The bench testing and clinical evaluation would assess the performance of this system (analyzer and test kit) in isolation, measuring its accuracy, precision, linearity, etc., without an explicit human-in-the-loop component influencing the measurement itself. The "user study clinical evaluation" did involve home users, but their role was in operating the device, not in interpreting results in conjunction with an AI algorithm.

    7. Type of Ground Truth Used

    The ground truth for the clinical evaluation was established by a "reference method". The specific nature of this reference method is not detailed, but for HbA1c assays, it typically refers to a highly accurate laboratory method (e.g., HPLC or mass spectrometry, often NGSP-certified) used to provide the true HbA1c values against which the device's measurements are compared.

    8. Sample Size for the Training Set

    The document does not specify a sample size for a training set. Immunoassays like the SD A1cCare System typically use a different development and validation paradigm than machine learning models that require distinct training and test sets. While the system may have undergone internal calibration and optimization during development, the text does not refer to a "training set" in the context of a machine learning algorithm.

    9. How Ground Truth for the Training Set Was Established

    As no "training set" in the machine learning sense is mentioned, this information is not available in the provided text. The calibration and performance optimization of an immunoassay system would typically be based on a series of characterized samples and reference methods, but this is not referred to as a "training set."

    Ask a Question

    Ask a specific question about this device

    K Number
    K132929

    Validate with FDA (Live)

    Manufacturer
    Date Cleared
    2015-08-05

    (687 days)

    Product Code
    Regulation Number
    862.1345
    Reference & Predicate Devices
    Predicate For
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    SD GlucoNavii® Mentor NFC Blood Glucose Monitoring System is intended to be used for the quantitative measurement of glucose (sugar) in fresh capillary whole blood from fingertip, palm, upper arm, or forearm. SD GlucoNavii® Mentor NFC Blood Glucose Monitoring System is intended to be used by a single person and should not be shared. It is intended for self-testing outside the body (in vitro diagnostic use) by people with diabetes at home as an aid to monitor the effectiveness of diabetes control.

    The SD GlucoNavii® Mentor NFC Blood Glucose Monitoring System should not be used for the diagnosis of or screening for diabetes. The SD GlucoNavii® Mentor NFC Blood Glucose Monitoring System is not for use in neonates. Alternative site testing should be done only during steady-state times (when glucose is not changing rapidly). SD GlucoNavii® Mentor NFC Blood Glucose Monitoring System is intended to be used to transmit glucose values to compatible mobile application or PC software through use of radio frequency communication.

    SD GlucoNavii® Mentor NFC Blood Glucose Test Strips are for use with SD GlucoNavii® Mentor NFC Blood Glucose Meter to quantitatively measure glucose (sugar) in fresh capillary whole blood samples drawn from the fingertips, forearm, upper arm, or palm.

    SD GlucoNavii® Mentor NFC Multi Blood Glucose Monitoring System is intended to be used for the quantitative measurement of glucose (sugar) in fresh capillary whole blood from fingertip, palm, upper arm, or forearm. The SD GlucoNavii® Mentor NFC Multi Blood Glucose Monitoring System is intended for testing outside the body (in vitro diagnostic use) and is intended for multiple-patient use in professional healthcare settings as an aid to monitor the effectiveness of diabetes control program. This system should only be used with auto-disabling, single-use lancing devices.

    The SD GlucoNavii® Mentor NFC Multi Blood Glucose Monitoring System should not be used for the diagnosis of or screening for diabetes. The SD GlucoNavi® Mentor NFC Multi Blood Glucose Monitoring System is not for use in neonates Alternative site testing should be done only during steady-state times (when glucose is not changing rapidly). SD GlucoNavii® Mentor NFC Multi Blood Glucose Monitoring System is intended to transmit glucose values to compatible mobile application or PC software through use of radio frequency communication.

    SD GlucoNavii® Mentor NFC Multi Blood Glucose Test Strips are for use with SD GlucoNavii® Mentor NFC Multi Blood Glucose Meter to quantitatively measure glucose (sugar) in fresh capillary whole blood samples drawn from the fingertips, forearm, upper arm, or palm.

    Device Description

    SD GlucoNavii® Mentor NFC and NFC Multi Blood Glucose Monitoring Systems are OTC/ Rx blood glucose monitoring systems. The SD GlucoNavii® Mentor NFC Blood Glucose Monitoring System is indicated for single-patient use at home (over-the-counter; OTC) and should not be shared, while The SD GlucoNavii® Mentor NFC Multi Blood Glucose Monitoring System is for multi-patient use in a professional healthcare setting(over-the-counter; OTC and prescription; POC), in order to help monitor the effectiveness of diabetes control. NFC devices contain near field communication (NFC) technology.

    SD GlucoNavii® Mentor NFC Blood Glucose Monitoring System includes:

    • SD GlucoNavii® Mentor NFC Blood Glucose Meter
    • SD GlucoNavii® Mentor NFC Blood Glucose Test Strips
    • SD Glucose Check Strip
    • SD Glucose Control Solution - Level M
    • 3V Battery Type CR2032
    • User Instruction Guide
    • Quick Guide
    • Test Strip Package Insert
    • Control Solution Package Insert
    • Carrying Case
    • Lancing Device, Lancet

    SD GlucoNavii® Mentor NFC Multi Blood Glucose Monitoring System includes:

    • SD GlucoNavii® Mentor NFC Multi Blood Glucose Meter
    • SD GlucoNavii® Mentor NFC Multi Blood Glucose Test Strips
    • SD Glucose Check Strip
    • SD Glucose Control Solution Level M
    • 3V Battery Type CR2032
    • User Instruction Guide
    • Quick Guide
    • Test Strip Package Insert
    • Control Solution Package Insert
    • Carrying Case

    Optional software accessory

    • GlucoNavii® DMS
    • GlucoNavii®

    A drop of blood sample from the finger prick works with glucose oxidase and the mediators in the test strip to make a small electric current proportional to the glucose concentration in the blood. The meter reads the current and displays the blood glucose result equivalent to the current.

    The user can search the stored results with three presentations of 7, 14 and 30-day averages of test results stored in memory: normal, pre-meal state averages. The system can set the beep, hypo warning, date, time, post-meal alarm. The system can also set the pre-meal and post-meal mark. Test results are displayed with mg/dL unit. A check strip allows the meter to check a problem and the control solution allows the meter and test strip to be checked.

    AI/ML Overview

    The provided text does not contain detailed information about specific acceptance criteria and a study proving the device meets them in the format usually expected for complex medical imaging devices or AI-driven diagnostic tools. This submission is for a Blood Glucose Monitoring System, which falls under a different regulatory pathway.

    However, based on the non-clinical and clinical tests performed, I can extract information related to "System Accuracy" and "User Performance Studies" as the closest equivalent to acceptance criteria and the studies performed.

    Here's an analysis based on the provided text, structured to answer your questions as best as possible given the available information:

    1. Table of Acceptance Criteria and Reported Device Performance

    The document mentions that "System accuracy evaluations (Method Comparison with Predicate Device) for the SD GlucoNavii Mentor NFC and NFC Multi Blood Glucose Monitoring Systems were performed according to ISO 15197." ISO 15197 is an international standard for in vitro diagnostic test systems for self-testing in managing diabetes mellitus. It defines minimum requirements for system accuracy.

    While the exact numerical acceptance criteria from ISO 15197 are not explicitly listed in the document, it's a common standard for blood glucose meters. The document states that "The study results support that SD GlucoNavii® Mentor NFC and NFC Multi Blood Glucose Monitoring Systems are substantially equivalence to other predicate devices in the market" and that the testing "met all relevant standards requirements." This implies compliance with ISO 15197.

    Based on typical ISO 15197:2013 (or earlier versions like 2003, which might have been relevant in 2015) standards for system accuracy:

    Acceptance Criteria (Typical ISO 15197)Reported Device Performance (Implied)
    For glucose concentrations < 100 mg/dL (5.55 mmol/L): Minimum 95% of results shall fall within ±15 mg/dL (±0.83 mmol/L) of the reference method.The document states, "System accuracy evaluations (Method Comparison with Predicate Device) for the SD GlucoNavii Mentor NFC and NFC Multi Blood Glucose Monitoring Systems were performed according to ISO 15197." It also concludes that "testing met all relevant standards requirements." This implies that the device achieved at least 95% of results within ±15 mg/dL of the reference method for glucose concentrations below 100 mg/dL, in accordance with ISO 15197.
    For glucose concentrations ≥ 100 mg/dL (5.55 mmol/L): Minimum 95% of results shall fall within ±15% of the reference method.Similarly, for glucose concentrations at or above 100 mg/dL, the device is implied to have achieved at least 95% of results within ±15% of the reference method, as required by ISO 15197.
    For the combined range: 99% of all individual glucose measurement results shall fall within zone A and B of the Consensus Error Grid.The document does not explicitly state CEG results, but compliance with ISO 15197 likely indicates adherence to this aspect as well, where 99% of results would fall within clinically acceptable ranges (Zone A and B) on the Consensus Error Grid. The statement "User performance studies were performed to demonstrate that lay consumers could obtain accurate results using the SD GlucoNavii® Mentor NFC and NFC Multi Blood Glucose Monitoring Systems" further supports the device's ability to produce clinically relevant and safe results when used by target users.

    2. Sample size used for the test set and the data provenance

    The document does not specify the exact sample size for the system accuracy or user performance studies. It only mentions that "System accuracy evaluations... were performed according to ISO 15197" and "User performance studies were performed."

    • Sample Size: Not specified in the provided text.
    • Data Provenance: Not specified (e.g., country of origin, retrospective/prospective). Studies for regulatory submissions are typically prospective clinical studies.

    3. Number of experts used to establish the ground truth for the test set and the qualifications of those experts

    The concept of "experts establishing ground truth" is not directly applicable in the same way for a blood glucose monitoring system as it would be for diagnostic imaging or AI.

    For blood glucose meters, the "ground truth" (reference method) is typically established by a central laboratory reference method (e.g., YSI 2300 STAT Plus Glucose & Lactate Analyzer or similar) which is regularly calibrated and precisely measures glucose concentrations in blood samples. These reference methods are highly accurate and do not rely on a panel of human experts for interpretation.

    • Number of experts: Not applicable in the context of ground truth for a blood glucose meter. The ground truth is established by a validated laboratory reference instrument.
    • Qualifications of those experts: Not applicable.

    4. Adjudication method for the test set

    Adjudication methods (e.g., 2+1, 3+1) are typically used in studies where human readers interpret data, and there's a need to resolve discrepancies in their interpretations to establish a final ground truth. This is not applicable to blood glucose measurement system accuracy where the reference method provides a definitive numerical value.

    • Adjudication method: Not applicable.

    5. If a multi reader multi case (MRMC) comparative effectiveness study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance

    MRMC studies and the concept of "human readers improve with AI vs without AI assistance" are relevant for AI-driven diagnostic tools that augment human interpretation, such as in radiology or pathology. This is not applicable to a standalone blood glucose monitoring system, which provides a numerical measurement directly to the user.

    • MRMC study: Not applicable.
    • Effect size of human reader improvement with/without AI: Not applicable.

    6. If a standalone (i.e. algorithm only without human-in-the-loop performance) was done

    A blood glucose monitoring system, by its nature, is a standalone device in terms of its measurement algorithm. The device measures glucose and displays a result. There isn't typically a "human-in-the-loop" influencing the measurement itself, beyond proper sample application and adherence to instructions. The "System Accuracy" and "User Performance" studies evaluate the device's standalone performance (its algorithm and hardware together) and its performance when used by a lay user, respectively.

    • Standalone performance: Yes, the "System Accuracy" assessment is essentially a standalone performance evaluation against a reference method. The "User Performance Studies" validate that lay users can obtain accurate results, implying the device's performance is robust even with typical user interaction.

    7. The type of ground truth used (expert consensus, pathology, outcomes data, etc.)

    The ground truth for blood glucose monitoring systems is established using a laboratory reference method (e.g., a highly accurate and calibrated glucose analyzer like a YSI instrument). This is considered the gold standard for glucose measurement in such studies.

    • Type of ground truth: Laboratory reference method.

    8. The sample size for the training set

    The concept of a "training set" and "testing set" is primarily relevant for machine learning or AI models. While the device likely undergoes extensive internal calibration and development (which could be considered analogous to "training"), the document does not refer to a distinct "training set" in the context of an AI algorithm. For a traditional electrochemical biosensor, the "training" involves optimizing the design, chemical reagents, and electronics using a range of known glucose concentrations during development.

    • Sample size for the training set: Not specified, and likely not applicable in the AI/ML sense.

    9. How the ground truth for the training set was established

    As above, the concept of a "training set ground truth" is not directly applicable to this type of device in the same way as AI. The "ground truth" during development and calibration would be established using glucose solutions or blood samples with precisely known glucose concentrations determined by highly accurate laboratory reference methods.

    Ask a Question

    Ask a specific question about this device

    Page 1 of 1