The indications for use of 3D Anatomical™ Mesh are:
- l) inguinal hernia repair
-
- ventral abdominal wall hernia repair
3D Anatomical™ Mesh is manufactured in a class 10,000 clean room environment in accordance with ISO 9001 and EN 46001 regulations. Full traceability will be maintained on all production lots.
The provided document, K990730: 3D Anatomical™ Mesh, describes in-vitro testing and clinical experience for a surgical mesh, but it does not contain information about acceptance criteria related to device performance in a study setting, nor does it detail a study proving the device meets such criteria.
The document does list some in-vitro test results that can be interpreted as de-facto acceptance criteria for manufacturing and material properties, but these are not presented as "acceptance criteria" for a clinical or performance study proving efficacy or safety in a patient population.
Here's an analysis based on the information available in the provided text, while highlighting the absence of information for most of your requested points:
Acceptance Criteria and Device Performance
The document presents in-vitro test results for the 3D Anatomical™ Mesh. These can be considered the required performance specifications that the manufactured mesh must meet.
| Acceptance Criteria (In-vitro) | Reported Device Performance (In-vitro) | Notes |
|---|---|---|
| Weave density: N/A | 0.91g/cm³ | This is a reported characteristic, not given as a specific minimum/maximum criteria. |
| Tensile strength: > 40 daN (> 50% elongation prior to rupture) | "must exceed 40 daN (greater than 50% elongation prior to rupture)" | The device reportedly meets this criterion. |
| Burst strength: > 500 kPa | "must exceed 500 kPa" | The device reportedly meets this criterion. |
| Comparative infrared spectrometry: Positive comparison to reference polypropylene (monofilament, 100% homopolymer) | Positive comparison | Confirmed chemical composition. |
| Comparative thermal analysis: Fusion temperatures between 160°C and 175°C, crystallization above 60% | Fusion temperatures between 160°C and 175°C, crystallization above 60% | Confirmed thermal properties. |
Missing Information for Device Acceptance Criteria and Performance Studies:
The following points cannot be addressed from the provided text as the document focuses on pre-market notification for a 510(k) submission, which typically relies on substantial equivalence and in-vitro data rather than extensive clinical efficacy studies with predefined acceptance criteria.
- Sample size used for the test set and the data provenance (e.g. country of origin of the data, retrospective or prospective)
- No information about a "test set" for performance evaluation in humans. The in-vitro tests were conducted by Institut Textile de France and Laboratoire de Rheologie des Matieres Plastiques (both in France).
- Number of experts used to establish the ground truth for the test set and the qualifications of those experts (e.g. radiologist with 10 years of experience)
- Not applicable as no clinical performance "test set" with ground truth is described.
- Adjudication method (e.g. 2+1, 3+1, none) for the test set
- Not applicable.
- If a multi-reader multi-case (MRMC) comparative effectiveness study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance
- Not applicable. This is a medical device (surgical mesh), not an AI diagnostic tool.
- If a standalone (i.e. algorithm only without human-in-the loop performance) was done
- Not applicable.
- The type of ground truth used (expert consensus, pathology, outcomes data, etc)
- Not applicable for a clinical performance study. For the in-vitro tests, the ground truth is established by standardized laboratory testing methods and comparison to reference materials.
- The sample size for the training set
- Not applicable. This is a medical device, not a machine learning algorithm that requires a "training set."
- How the ground truth for the training set was established
- Not applicable.
Clinical Experience Mentioned:
While not a formal "study" proving acceptance criteria, the document states:
- "Clinical experience of 3D Anatomical™ Mesh began internationally in 1994 and now includes thousands of mesh implants."
This indicates post-market surveillance data or anecdotal reports (prior to the 1999 filing) rather than a controlled study specifically designed to meet pre-defined acceptance criteria for efficacy or safety. The 510(k) approval process often relies on existing clinical use and substantial equivalence to a predicate device rather than new, large-scale clinical trials for every device.
Ask a specific question about this device