Found 2 results

510(k) Data Aggregation

    K Number
    K223122

    Validate with FDA (Live)

    Date Cleared
    2023-08-03

    (304 days)

    Product Code
    Regulation Number
    878.5000
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    N/A
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The MENIX® / MENIX® DUO Meniscal Suture Systems are indicated for use as suture retention devices to facilitate percutaneous or endoscopic soft tissue procedures. The MENIX® DUO systems are indicated for use in meniscal repairs and allograft transplant procedures. The MENIX® / MENIX® DUO systems are intended to be used for anchoring the allograft to the meniscal rim during allograft transplant procedures. The MENIX ® / MENIX® DUO devices are intended for single use only.

    Device Description

    The MENIX® / MENIX® DUO devices are intended to be used for all-inside meniscal repair:

    • The MENIX® system consists of a single-use launcher which deploys a nonabsorbable implant composed of one anchor pre-tied with a suture.
    • MENIX® DUO system consists of a single-use launcher which deploys a nonabsorbable implant composed of two anchors connected by a suture.
      Each anchor is pre-mounted on a needle to allow its deployment through the meniscus by pressing on the associated button. A transparent sheath acts as a penetration depth limiter and as a protection for users. As the MENIX® meniscal suture system consists of only one anchor associated with a suture, this suture must be tied to another MENIX® / MENIX® DUO meniscal suture system. The devices are supplied sterile, individually packaged and ready to use
    AI/ML Overview

    The provided text is a 510(k) summary for the Menix®/Menix® Duo Meniscal Suture Systems. It describes a medical device and its equivalence to a predicate device, based on non-clinical performance data. This document does NOT describe a study involving an AI/Machine Learning device or a Multi-Reader Multi-Case (MRMC) comparative effectiveness study, nor does it establish ground truth with human experts.

    Therefore, I cannot provide information for most of the requested points, as they are not relevant to the content of this 510(k) summary. I can only provide details on the acceptance criteria and performance as they relate to the mechanical and biological testing for this specific type of medical device (surgical suture system).

    Here's what can be extracted and what cannot:

    1. A table of acceptance criteria and the reported device performance:

    The document states:

    • "The mechanical performance data demonstrates that MENIX ® / MENIX® DUO meniscal suture system met performance specifications for traction strength and fatigue displacement traction strength through Dynamic then static tensile tests based on established acceptance criteria taken from the state of the art (Baraber's studies) and in comparison to the predicate device FAST-FIX 360 Meniscal Repair System (K121861)."
    • "All acceptance criteria were met and MENIX ® / MENIX® DUO meniscal suture system were deemed biologically safe."

    However, specific numerical acceptance criteria or the reported performance values (e.g., actual traction strength in Newtons or displacement in mm) are not provided in this summary. The table below reflects the general statements made.

    Test ParameterAcceptance CriteriaReported Device Performance
    BiocompatibilityMet ISO 10993-1 (2018) requirements through risk analysis; existing data and chemical characterization assessed."All acceptance criteria were met and MENIX ® / MENIX® DUO meniscal suture system were deemed biologically safe."
    Mechanical PerformancePerformance specifications for traction strength and fatigue displacement traction strength, based on "state of the art (Baraber's studies)" and comparison to predicate device (FAST-FIX 360 Meniscal Repair System (K121861))."MENIX ® / MENIX® DUO meniscal suture system met performance specifications for traction strength and fatigue displacement traction strength through Dynamic then static tensile tests based on established acceptance criteria taken from the state of the art (Baraber's studies) and in comparison to the predicate device FAST-FIX 360 Meniscal Repair System (K121861)."

    2. Sample sized used for the test set and the data provenance (e.g. country of origin of the data, retrospective or prospective)

    • Sample Size: Not specified in the document for any of the tests (biocompatibility or mechanical performance).
    • Data Provenance: The device manufacturer (S.B.M. SAS) is located in Lourdes, France. The studies are non-clinical, likely laboratory-based. No mention of retrospective or prospective data.

    3. Number of experts used to establish the ground truth for the test set and the qualifications of those experts (e.g. radiologist with 10 years of experience)

    • Not applicable. This relates to human expert review for AI/ML ground truth, which is not described in this document. The "ground truth" for this device's performance is established via standardized laboratory mechanical and biological testing.

    4. Adjudication method (e.g. 2+1, 3+1, none) for the test set

    • Not applicable. This relates to human expert review for AI/ML ground truth, which is not described in this document.

    5. If a multi reader multi case (MRMC) comparative effectiveness study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance

    • No, an MRMC study was not done. This document describes a medical device, not an AI/ML diagnostic or assistive tool. The comparison is between the new device's mechanical properties and those of a predicate device, using non-clinical testing.

    6. If a standalone (i.e. algorithm only without human-in-the-loop performance) was done

    • Not applicable. This is not an AI algorithm.

    7. The type of ground truth used (expert concensus, pathology, outcomes data, etc)

    • The "ground truth" for this device's safety and effectiveness relies on results from standardized mechanical performance tests (traction strength, fatigue displacement traction strength) and biocompatibility tests (per ISO 10993-1), compared against established specifications and a predicate device. It is not based on expert consensus, pathology, or outcomes data in the traditional sense for diagnostic tools.

    8. The sample size for the training set

    • Not applicable. This document does not describe an AI/ML device that requires a training set.

    9. How the ground truth for the training set was established

    • Not applicable. This document does not describe an AI/ML device that requires a training set.
    Ask a Question

    Ask a specific question about this device

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The PULLUP® BTB, BT LOOP®, PULLUP® CLIP and PULLUP® TEX CLIP devices are designed to be used as cortical fixation for ACL reconstruction.

    Device Description

    The device is proposed in the following variants:

    • -PULLUP®: comprises a titanium button-plate, and an adjustable nonabsorbable braided loop. The system is preloaded with traction and flip threads, and is designed to be used with a soft tissue graft.
    • PULLUP® BTB: comprises a titanium button-plate, and an adjustable nonabsorbable braided loop. The system is preloaded with traction and flip threads, as well as a temporary splice suture, and is designed to be used with a bone-tendon-bone graft.
    • -BT LOOP®: comprises a titanium button-plate, and an adjustable nonabsorbable braided loop. The system is preloaded with traction and flip threads, as well as a temporary splice suture, and is designed to be used with a bone-tendon-bone graft. It is assembled on a holder that must be mounted on the GraftTech® preparation station.
    • -PULLUP® CLIP: comprises a titanium button-plate only, is designed to be used with a soft tissue graft, and can either be connected to another PULLUP® CLIP button-plate by using the PULLUP® TEX CLIP nonabsorbable braided loop, or can be connected to another PULLUP® device.

    Standard models are used for cortical tunnels with a diameter of 4.5 mm; XL models are used for cortical tunnels with a diameter between 5 and 10 mm.

    The implants are supplied sterile, individually packaged, ready to use.

    AI/ML Overview

    This is a 510(k) premarket notification for a medical device, not a study evaluating an AI algorithm. Therefore, the standard information requested for describing acceptance criteria and a study proving device performance for an AI algorithm is not applicable here.

    Here's a breakdown of why the requested information cannot be provided from the given document:

    • This is not an AI/Software as a Medical Device (SaMD) submission: The document describes PULLUP® BTB, PULLUP® CLIP, PULLUP® TEX CLIP adjustable fixation systems, and BT LOOP® for ligament reconstruction. These are physical implants, not AI algorithms.
    • The document focuses on substantial equivalence to a predicate device: The purpose of a 510(k) submission is to demonstrate that a new device is as safe and effective as a legally marketed predicate device. It doesn't typically involve new clinical studies with acceptance criteria in the way AI algorithm validation does.
    • "Device performance" refers to mechanical and biological properties: In this context, "device performance" refers to the biocompatibility, biological, and mechanical properties of the physical implant, not the diagnostic or predictive performance of an algorithm.

    Based on the provided text, I can extract the following relevant information regarding non-clinical performance:

    1. Acceptance Criteria and Reported Device Performance (Non-Clinical)

    Acceptance Criteria CategoryReported Device Performance (Summary)
    BiocompatibilityNot impacted by changes. Satisfactory.
    Biological PerformanceNot impacted by changes. Satisfactory.
    Mechanical PerformanceNot impacted by changes. Satisfactory; devices functional within intended use.
    Non-pyrogenicDevice determined to be non-pyrogenic.

    Explanation: The document states that "Non-clinical testing including biocompatibility, biological and mechanical performances were not impacted by the change. The results indicated that the devices were functional within their intended use and equivalent to the predicate devices. The proposed device has been determined to be non-pyrogenic." This indicates that the new variants met the established non-clinical performance and safety profiles, thus fulfilling the acceptance criteria for these aspects.


    The following requested information is NOT APPLICABLE or NOT AVAILABLE in the provided document, as it pertains to AI/algorithm validation, not to the premarket notification of a physical medical device:

    • Sample size used for the test set and the data provenance: Not applicable.
    • Number of experts used to establish the ground truth for the test set and the qualifications of those experts: Not applicable.
    • Adjudication method for the test set: Not applicable.
    • If a multi-reader multi-case (MRMC) comparative effectiveness study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance: Not applicable.
    • If a standalone (i.e., algorithm only without human-in-the-loop performance) was done: Not applicable.
    • The type of ground truth used (expert consensus, pathology, outcomes data, etc.): Not applicable.
    • The sample size for the training set: Not applicable.
    • How the ground truth for the training set was established: Not applicable.

    In summary, this document describes the substantial equivalence of a physical medical device (ligament fixation systems) through non-clinical testing, not the performance validation of an AI algorithm.