Found 23 results

510(k) Data Aggregation

    K Number
    K202266

    Validate with FDA (Live)

    Date Cleared
    2022-03-29

    (595 days)

    Product Code
    Regulation Number
    888.3080
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The Reliance Cervical IBF System is indicated for intervertebral body fusion of the spine in skeletally mature patients. The system devices are designed for use with autogenous bone graft to facilitate fusion. One device may be used per intervertebral space. The implants are intended to be used with legally cleared supplemental spinal fixation cleared for the implanted level.

    The Reliance Cervical IBF System is intended for use at one level in the cervical spine, from C3 to T1, for treatment of cervical degenerative disc disease (DDD is defined as neck pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies). The Reliance Cervical IBF System is to be used in patients who have six weeks of non-operative treatment.

    Device Description

    The Reliance Cervical IBF System is comprised of implant and instrument components. The implant component, the Reliance Cervical IBF device, is a spacer which inserts between vertebral bodies in the anterior column of the cervical spine. The subject Reliance Cervical IBF spacer is additively manufactured from Titanium 6A1-4V ELI as specified in ASTM F3001, with predicate spacers manufactured from PEEK Optima LT1 or PEEK Optima LT1-HA.

    AI/ML Overview

    This document is a 510(k) Summary for a medical device called the "Reliance Cervical IBF System." It describes the device, its intended use, and argues for its substantial equivalence to previously cleared predicate devices. Crucially, the document does NOT contain information about acceptance criteria or a study proving the device meets acceptance criteria in the way typically associated with clinical performance or efficacy studies.

    Instead, the "Performance Data and Substantial Equivalence" section refers to engineering and manufacturing performance testing to demonstrate that the new device, which has a material modification (Titanium 6Al-4V ELI) compared to its predicates (PEEK Optima LT1 or PEEK Optima LT1-HA), is still substantially equivalent to the predicates. Therefore, many of the requested categories cannot be filled from this document as they pertain to clinical or diagnostic performance studies, which are not described here.

    Here's an attempt to answer the questions based only on the provided text, acknowledging that much of the requested information regarding "acceptance criteria" and "study proving the device meets acceptance criteria" in a clinical performance context is not present.


    1. A table of acceptance criteria and the reported device performance

    The document does not explicitly state "acceptance criteria" in terms of clinical performance metrics (e.g., sensitivity, specificity, accuracy, or clinical success rates). Instead, it refers to compliance with engineering and manufacturing standards. Therefore, a table of clinical acceptance criteria and reported device performance cannot be generated from this text. The performance data mentioned relates to demonstrating substantial equivalence for engineering properties.

    Acceptance Criteria Category (Implied)Reported Device Performance (Reference to Standards)
    Mechanical PerformanceCompliance with ASTM F2077-18 and F2267-04 (2018) standards
    Packaging IntegrityCompliance with ASTM D4169, D4332, F88, F1886, F2096
    Cleaning ValidationCompliance with ASTM F2459 and F2847
    Sterilization EfficacyCompliance with ANSI/AAMI/ISO 11137-1:2006/A1:2013/A2:2019, ANSI/AAMI/ISO 11137-2:2013, ANSI/AAMI/ISO 11737-1:2006, ANSI/AAMI/ISO 11737-2:2009, and ANSI/AAMI/ISO TIR13004:2013
    BiocompatibilityDetermined to be substantially equivalent to predicate devices

    2. Sample size used for the test set and the data provenance (e.g. country of origin of the data, retrospective or prospective)

    This information is not provided. The performance data described are related to engineering and manufacturing tests, not clinical test sets.

    3. Number of experts used to establish the ground truth for the test set and the qualifications of those experts (e.g. radiologist with 10 years of experience)

    This information is not provided as there is no description of a clinical test set requiring expert ground truth.

    4. Adjudication method (e.g. 2+1, 3+1, none) for the test set

    This information is not provided as there is no description of a clinical test set requiring adjudication.

    5. If a multi reader multi case (MRMC) comparative effectiveness study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance

    There is no mention of an MRMC study or AI in this document. This device is an intervertebral body fusion system, not an AI/imaging diagnostic device.

    6. If a standalone (i.e. algorithm only without human-in-the-loop performance) was done

    This is not applicable. The device is a physical implant, not an algorithm.

    7. The type of ground truth used (expert consensus, pathology, outcomes data, etc)

    This information is not provided as there is no description of a clinical test set requiring ground truth. The "ground truth" for the engineering tests would be the specifications outlined in the referenced ASTM/ISO standards.

    8. The sample size for the training set

    This information is not provided as there is no mention of a training set, which is typically associated with AI/machine learning models or studies involving clinical data for training.

    9. How the ground truth for the training set was established

    This information is not provided as there is no mention of a training set or how its ground truth would be established.


    Summary regarding the device and the document:

    This 510(k) summary focuses on demonstrating "substantial equivalence" of a modified medical device to existing, legally marketed predicate devices. The modification is primarily a change in material for the intervertebral body fusion spacer, from PEEK to Titanium 6A1-4V ELI.

    The "study that proves the device meets the acceptance criteria" in this context refers to a battery of engineering and manufacturing tests (mechanical, packaging, cleaning, sterilization, biocompatibility) conducted according to recognized ASTM and ISO standards. The "acceptance criteria" are implied to be the successful compliance with these standards, demonstrating that the new material does not negatively impact the device's fundamental safety and effectiveness compared to the predicate, making it substantially equivalent.

    The document does not describe any clinical trials, performance studies, or efficacy studies involving human subjects or clinical data in the form requested to directly assess performance metrics like sensitivity, specificity, or clinical outcomes. For intervertebral body fusion devices in the 510(k) pathway, such extensive clinical performance studies are often not required if substantial equivalence can be demonstrated through other means (e.g., material testing, biomechanical testing, and comparison of design/indications to predicates).

    Ask a Question

    Ask a specific question about this device

    K Number
    K210874

    Validate with FDA (Live)

    Date Cleared
    2021-05-13

    (50 days)

    Product Code
    Regulation Number
    888.3070
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The Reliance Spinal Screw System is a pedicle screw system intended to provide immobilization of spinal segments in skeletally mature patients as an adjunct to fusion in the treatment of the following acute and chronic instabilities or deformities of the thoracic, lumbar, and sacral spine: degenerative disc disease (DDD) (defined as back pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies), degenerative spondylolisthesis with objective evidence of neurological impairment, fracture, dislocation, scoliosis, spinal tumor, and failed previous fusion (pseudarthrosis). The Reliance Spinal Screw System is also indicated for pedicle screw fixation for the treatment of severe spondylolisthesis (Grades 3 and 4) of the L5-S1 vertebra in skeletally-mature patients receiving fusion by autogenous bone graft and having implants attached to the lumbar and sacral spine (L3 to sacrum) with removal of the implants after the attainment of a solid fusion.

    When used posteriorly, the Reliance Spinal Screw System is also a hook and sacral/iliac screw fixation system of the noncervical spine indicated for: spondylolisthesis, trauma (fracture and/or dislocation), spinal stenosis, deformities (scoliosis, lordosis and/or kyphosis), tumor, and previous failed fusion (pseudarthrosis). Levels of fixation are for the thoracic, lumbar and sacral spine.

    The Reliance Spinal Screw System, when used with staples and two rods as an anterior thoracic/lumbar screw fixation system, is indicated for spondylolisthesis, trauma (fracture and/or dislocation), spinal stenosis, deformities (scoliosis, lordosis and/or kyphosis), tumor, and previous failed fusion (pseudarthrosis).

    When used in a percutaneous, posterior approach with MIS instrumentation, the Reliance Spinal Screw System components are intended for noncervical pedicle fixation and nonpedicle fixation for the following indications: spondylolisthesis, trauma (i.e., fracture or dislocation), spinal stenosis, curvatures (i.e., scoliosis, kyphosis, and/or lordosis), tumor, pseudarthrosis, and failed previous fusion in skeletally-mature patients.

    Device Description

    The Posterior Reliance Spinal Screw System consists of longitudinal rods, monoaxial screws, polyaxial screws, reduction screws, cannulated polyaxial screws, cannulated reduction screws, hooks, reduction hooks, set screws and transverse connectors.

    The Anterior Reliance Spinal Screw System consists of spinal rods, monoaxial screws, staples, and set screws. The Anterior Reliance staples and screws are intended to the lateral aspect of the vertebral bodies from T5 to L4, and SHOULD NOT be attached to the anterior aspect. Furthermore, only Titanium components should be used anteriorly. (See Precautions section)

    The Reliance Spinal Screw System components are available in titanium alloy conforming to ASTM F-136 specifications as well as stainless steel conforming to ASTM F-138 specifications. Furthermore, various rods of the Reliance Spinal Screw System are available in Cobalt-Chrome conforming to ASTM F-75 and ASTM F-1537 specifications. Components of the differing diameter rod systems are NOT interchangeable. The components of one material should not be used with components of another material, with the exception that the Cobalt-Chrome rods may be used with titanium alloy implants. The extension tabs on the reduction screw and hook components are intended to be removed intraoperatively.

    The subject Reliance Spinal Screw offers two new fenestrated screw systems (single and circumferential) for use with saline or radiopaque dye only, a percutaneous screw system, and two barend rod systems. These additions will be available in similar sizes, material and configurations as the currently approved Reliance Spinal Screws.

    AI/ML Overview

    This document is a 510(k) Premarket Notification from the FDA regarding the Reliance Spinal Screw System. It focuses on establishing substantial equivalence to previously marketed devices rather than presenting a study to prove acceptance criteria for a new device's performance. Therefore, the requested information, which pertains to studies demonstrating a device's performance against defined acceptance criteria (common for AI/ML or diagnostic devices), is largely not applicable in this context.

    However, I can extract the relevant information regarding acceptance criteria in the form of substantial equivalence and the type of data presented to support that equivalence.

    Here's an analysis based on the provided text:

    Device: Reliance Spinal Screw System

    1. A table of acceptance criteria and the reported device performance:

    Since this is a 510(k) submission for a spinal screw system, the "acceptance criteria" are primarily related to substantial equivalence to predicate devices in terms of design, materials, intended use, and mechanical performance. There isn't a performance table in the typical sense of a diagnostic or an AI/ML device (e.g., sensitivity, specificity).

    Acceptance Criteria (for Substantial Equivalence to Predicate Devices)Reported Device Performance (as demonstrated by comparison)
    Intended Use: Match predicate devices.The Indications for Use are consistent with the predicate devices.
    Levels of Attachment: Match predicate devices.The device is intended for fixation at the thoracic, lumbar, and sacral spine, consistent with predicate devices.
    Design/Configuration: Similar components (rods, screws, hooks, etc.).The subject device introduces new fenestrated screw systems (single and circumferential), a percutaneous screw system, and two barend rod systems. These are presented as additions/modifications to the existing Reliance Spinal Screw System (K162066) and are considered similar in configuration.
    Material: Identical or recognized biocompatible and mechanically sound materials.Components are available in titanium alloy (ASTM F-136) and stainless steel (ASTM F-138). Cobalt-Chrome rods (ASTM F-75 and ASTM F-1537) are also available. These materials are consistent with those found in predicate devices.
    Size Range: Comparable to predicate devices.The additions are available in "similar sizes" to the currently approved Reliance Spinal Screws.
    Strength/Mechanical Performance: Meet recognized standards, or demonstrate no new worst-case scenario.Non-Clinical Testing (Static Compressive, Static Torsion, Dynamic Compressive) was performed in accordance with ASTM F1717 on the predicate Reliance Spinal Screw System. The current submission argues that the changes and additions "do not represent a new worst case; therefore, no new mechanical performance testing is warranted."
    Sterilization & Biocompatibility: Consistent with predicate devices.The subject device is stated to be "substantially equivalent to the predicate devices in terms of sterilization and biocompatibility."

    2. Sample size used for the test set and the data provenance:

    • Sample Size for Test Set: Not applicable. There is no "test set" in the context of clinical performance evaluation for this type of device in this document. The mechanical testing was done on the predicate device, and the current device is deemed to not require new testing due to no new worst-case scenario.
    • Data Provenance: Not applicable for a typical clinical test set. The data cited are from non-clinical mechanical testing standards (ASTM F1717) applied to the predicate device. The information is retrospective in the sense that it relies on prior testing of the predicate.

    3. Number of experts used to establish the ground truth for the test set and the qualifications of those experts:

    • Not applicable. There is no "ground truth" established by experts in the context of a clinical test set from this document. The assessment is based on engineering principles, materials science, and regulatory comparison.

    4. Adjudication method for the test set:

    • Not applicable. No clinical test set requiring adjudication is described.

    5. If a multi reader multi case (MRMC) comparative effectiveness study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance:

    • Not applicable. This is not a diagnostic device or an AI-assisted device.

    6. If a standalone (i.e. algorithm only without human-in-the-loop performance) was done:

    • Not applicable. This is not an algorithm or AI device.

    7. The type of ground truth used:

    • The "ground truth" in this context is implicitly the historical safety and effectiveness of the identified predicate devices as demonstrated by their prior FDA clearance and adherence to recognized mechanical testing standards (ASTM F1717). This is a regulatory "ground truth" for substantial equivalence.

    8. The sample size for the training set:

    • Not applicable. This is not an AI/ML device so there is no training set.

    9. How the ground truth for the training set was established:

    • Not applicable. No training set is described.

    In summary: This 510(k) submission for the Reliance Spinal Screw System demonstrates substantial equivalence to predicate devices primarily through non-clinical assessment of design, materials, and existing mechanical testing data from the predicate device, rather than presenting a performance study against specific acceptance criteria for a new clinical performance claim.

    Ask a Question

    Ask a specific question about this device

    K Number
    K173283

    Validate with FDA (Live)

    Date Cleared
    2018-01-19

    (95 days)

    Product Code
    Regulation Number
    888.3080
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The Reliance Lumbar IBF System is indicated for intervertebral body fusion of the spine in skeletally mature patients. The device systems are designed for use with autogenous bone graft to facilitate fusion. One device may be used per intervertebral space. The implants are intended to be used with legally cleared supplemental spinal fixation cleared for the implanted level.

    The Reliance Lumbar IBF System, when used as an Intervertebral Body Fusion device is also intended for use at either one level or two contiguous levels in the lumbar spine, from L2 to S1, for the treatment of degenerative disease (DDD) with up to Grade 1 Spondylolisthesis. DDD is defined as back pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies. The lumbar device is to be used with patients who have had six months of non-operative treatment.

    Device Description

    The Reliance Lumbar IBF System, originally cleared by FDA in K113540, is intended to be used as an intervertebral body fusion device. Reliance Lumbar IBF device is a spacer, which inserts between vertebral bodies in the anterior column of the thoracic and lumbar spine. The device is surgically implanted between vertebral bodies from an anterior, lateral, or posterior surgical approach. The Reliance Lumbar IBF device will be manufactured from PEEK. The PEEK device also contains Tantalum wires to aid in fluoroscopic visualization. The construct is not intended to be employed as a standalone device. The Reliance Lumbar IBF is to be used with supplemental fixation in all applications.

    AI/ML Overview

    The provided text describes a 510(k) premarket notification for the "Reliance Lumbar IBF System" and does not contain information related to an AI/ML powered device, nor does it present acceptance criteria or a study proving device performance as typically expected for such devices.

    The document is for an intervertebral body fusion device and outlines its indications for use, technological modifications (additional implant sizes and instruments), and claims substantial equivalence to a predicate device. The conclusion is based on a risk analysis and design verification testing, not on a clinical study evaluating diagnostic or prognostic performance of an AI/ML algorithm.

    Therefore, I cannot extract the requested information regarding acceptance criteria, study details, sample sizes, expert qualifications, adjudication methods, MRMC studies, standalone performance, ground truth, or training set size, as this information is not present in the provided context.

    Ask a Question

    Ask a specific question about this device

    K Number
    K173102

    Validate with FDA (Live)

    Date Cleared
    2017-12-29

    (91 days)

    Product Code
    Regulation Number
    888.3080
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The RELIANCE CERVICAL IBF System is indicated for intervertebral body fusion of the spine in skeletally mature patients. The device systems are designed for use with autogenous bone graft to facilitate fusion. One device may be used per intervertebral space. The implants are intended to be used with legally cleared supplemental spinal fixation cleared for the implanted level.

    The RELIANCE CERVICAL IBF System is intended for use at one level in the cervical spine, from C3 to T1, for treatment of cervical disc disease (defined as neck pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies). The RELIANCE CERVICAL IBF System is to be used in patients who have six weeks of non-operative treatment.

    Device Description

    The Reliance Cervical IBF System is comprised of implants and instrument components. The implant component, the Reliance Cervical IBF device, is a spacer, which inserts between vertebral bodies in the anterior column of the cervical spine. The spacer is made of PEEK Optima LT1 or PEEK Optima LT1-HA with Tantalum markers. The Reliance Cervical IBF System also includes bone screws to secure the device to the vertebral body.

    AI/ML Overview

    This document is a 510(k) Premarket Notification from the FDA regarding the "Reliance Cervical IBF System." It is primarily a regulatory approval document and does not contain information about the acceptance criteria or a study that proves the device meets the acceptance criteria in the format requested for AI/medical device performance evaluation.

    The document pertains to an intervertebral body fusion device and confirms its substantial equivalence to previously marketed predicate devices (K120396, K131429, K142269 & K172489). The "Non-Clinical Testing" section mentions that the system has undergone mechanical testing according to ASTM standards (ASTM F-2077, ASTM F-2267, and ASTM Draft F-04.25.02.02). However, it does not provide specific acceptance criteria or performance results from these tests. These are standard tests for mechanical integrity of implants, not for AI performance.

    Therefore, I cannot provide the requested information as it is not present in the provided text. The questions regarding sample size, data provenance, number of experts, adjudication methods, multi-reader multi-case studies, standalone performance, ground truth types, and training set information are all relevant to the evaluation of AI models or diagnostic devices, which this document does not describe. This is a physical implant device, not an AI or diagnostic software.

    Ask a Question

    Ask a specific question about this device

    K Number
    K172489

    Validate with FDA (Live)

    Date Cleared
    2017-09-07

    (21 days)

    Product Code
    Regulation Number
    888.3080
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The Reliance Cervical IBF System is indicated for intervertebral body fusion of the spine in skeletally mature patients. The device systems are designed for use with autogenous bone graft to facilitate fusion. One device may be used per intervertebral space. The Reliance Cervical IBF and Reliance Cervical IBF-HA implants are intended to be used with legally cleared supplemental spinal fixation cleared for the implanted level.

    The Reliance Cervical IBF System is intended for use at one level in the cervical spine, from C3 to T1, for treatment of cervical disc disease (defined at neck pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies). The Reliance Cervical IBF System is to be used in patients who have six weeks of non-operative treatment.

    Device Description

    The Reliance Cervical IBF System is comprised of implant and instrument components. The Reliance Cervical IBF, the implant component, is a spacer which inserts between vertebral bodies in the anterior column of the cervical spine. The Reliance Cervical IBF spacer is either comprised of PEEK Optima HA with Tantalum markers, or from PEEK Optima LT1 with Tantalum markers. The Reliance Cervical IBF-S spacer (PEEK Optima LT1 or PEEK Optima HA) also incorporates screws to better fixate and stabilize the spine. These screws are manufactured from Titanium alloy as described by ASTM F-136. The device is intended for interbody fusion in the cervical spine and to aid in the surgical correction and stabilization of the spine.

    AI/ML Overview

    I am sorry, but the provided text does not contain information about acceptance criteria or a study proving device performance in the context of an AI/human reader comparative effectiveness study, standalone algorithm performance, ground truth establishment, or sample sizes for training and testing sets.

    The document is a 510(k) premarket notification for the "Reliance Cervical IBF System," which is an implantable medical device for intervertebral body fusion. The FDA review letter and the 510(k) summary describe the device's classification, indications for use, substantial equivalence to a predicate device, and technological modifications (specifically, additional sizes for existing implant designs).

    The critical information you requested, such as performance metrics, study design, or expert involvement, is not present in this regulatory submission for an implantable hardware device. Such information would be typical for AI-powered diagnostic or screening tools.

    Ask a Question

    Ask a specific question about this device

    K Number
    K162066

    Validate with FDA (Live)

    Date Cleared
    2016-12-02

    (129 days)

    Product Code
    Regulation Number
    888.3070
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The Reliance Spinal Screw System is a pedicle screw system intended to provide immobilization of spinal segments in skeletally mature patients as an adjunct to fusion in the treatment of the following acute and chronic instabilities or deformities of the thoracic, lumbar, and sacral spine: degenerative spondylolisthesis with objective evidence of neurological impairment, fracture, dislocation, scoliosis, spinal tumor, and failed previous fusion (pseudarthrosis). The Reliance Spinal Screw System is also indicated for pedicle screw fixation for the treatment of severe spondylolisthesis (Grades 3 and 4) of the L5-S1 vertebra in skeletally mature patients receiving fusion by autogenous bone graft having implants attached to the lumbar and sacral spine (L3 to sacrum) with removal of the implants after the attainment of a solid fusion.

    When used posteriorly, the Reliance Spinal Screw System is also a hook and sacral/iliac screw fixation system of the noncervical spine indicated for spondylolisthesis, trauma (fracture and/or dislocation), spinal stenosis, deformities (scoliosis, lordosis, and/or kyphosis), tumor, and previous failed fusion (pseudarthrosis). Levels of fixation are for the thoracic, lumbar, and sacral spine.

    The Reliance Spinal Screw System when used with staples and two rods as an anterior thoracic/lumbar screw fixation system, is indicated for spondylolisthesis, trauma (fracture and/or dislocation), spinal stenosis, deformities (scoliosis, lordosis and/or kyphosis), tumor, and previous failed fusion (pseudarthrosis).

    When used in a percutaneous, posterior approach with MIS Instrumentation, the Reliance Spinal Screw System components are intended for noncervical pedicle fixation and nonpedicle fixation for the following indications: spondylolisthesis; trauma (i.e., fracture or dislocation); spinal stenosis; curvatures (i.e., scoliosis, and/or lordosis); tumor; pseudoarthrosis; and failed previous fusion in skeletally mature patients.

    Device Description

    The Posterior Reliance Spinal Screw System consists of longitudinal rods, monoaxial screws, polyaxial screws, reduction screws, cannulated polyaxial screws, cannulated reduction screws, hooks, reduction hooks, set screws and transverse connectors. The Anterior Reliance Spinal Screw System consists of spinal rods, monoaxial screws. staples, and set screws. The Anterior Reliance staples and screws are intended to be attached to the lateral aspect of the vertebral bodies from T5 to L4, and SHOULD NOT be attached to the anterior aspect. Furthermore, only Titanium components should be used anteriorly. (See Precautions section)

    The Reliance Spinal Screw System components are available in titanium alloy conforming to ASTM F-136 specifications as well as stainless steel conforming to ASTM F-138 specifications. Furthermore, various rods of the Reliance Spinal Screw System are available in Cobalt-Chrome conforming to ASTM F-75 and ASTM F-1537 specifications.

    Components of the differing diameter rod systems are NOT interchangeable. The components of one material should not be used with components of another material, with the exception that the Cobalt-Chrome rods may be used with titanium alloy implants. The extension tabs on the reduction screw and hook components are intended to be removed intraoperatively.

    AI/ML Overview

    The provided document is a 510(k) premarket notification from the FDA for the Reliance Spinal Screw System. It details the device's indications for use, its description, and its substantial equivalence to previously marketed devices. However, it does not describe a study that proves the device meets specific acceptance criteria in the context of an AI/ML medical device.

    The document discusses "Non-Clinical Testing" which includes "Static Compressive and Dynamic Compressive in accordance with ASTM F1717." This refers to mechanical testing standards for spinal implant constructs, not a clinical study involving human patients or a study validating an AI algorithm.

    Therefore, I cannot fulfill the request to describe the acceptance criteria and a study proving an AI device meets them using the provided text. The document is about a traditional mechanical spinal implant, not an AI/ML medical device.

    Ask a Question

    Ask a specific question about this device

    K Number
    K160463

    Validate with FDA (Live)

    Date Cleared
    2016-05-20

    (91 days)

    Product Code
    Regulation Number
    888.3080
    Age Range
    All
    Reference & Predicate Devices
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The Reliance LUMBAR IBF System is indicated for intervertebral body fusion of the spine in skeletally mature patients. The device systems are designed for use with autogenous bone graft to facilitate fusion. One device may be used per intervertebral space. The implants are intended to be used with legally cleared supplemental spinal fixation cleared for the implanted level.

    The Reliance LUMBAR IBF System, when used as an Intervertebral Body Fusion device is also intended for use at either one level or two contiguous levels in the lumbar spine, from L2 to S1, for the treatment of degenerative disease (DDD) with up to Grade 1 spondylolisthesis. DDD is defined as back pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies. The lumbar device is to be used in patients who have had six months of non-operative treatment.

    Device Description

    The Reliance Lumbar IBF System is comprised of implant and instrument components. The implant component, the Reliance Lumbar IBF device, is a spacer, which inserts between vertebral bodies in the anterior column of the lumbar spine. The spacer is made of PEEK OPTIMA LT1 with Tantalum markers.

    AI/ML Overview

    The provided documents are a 510(k) Pre-market Notification from the FDA regarding the "Reliance Lumbar IBF System." This document primarily focuses on demonstrating substantial equivalence to previously cleared devices rather than presenting a study of its own performance against specific acceptance criteria.

    Therefore, the requested information about acceptance criteria and a study proving the device meets them, particularly regarding AI or algorithm performance, cannot be extracted from this document because:

    • The device is a physical medical implant (intervertebral body fusion device), not an AI/software device. This type of device does not have "acceptance criteria" in the sense of performance metrics for an algorithm (e.g., sensitivity, specificity, AUC). Its acceptance is based on meeting mechanical and material specifications, biocompatibility, and substantial equivalence to existing devices.
    • The document describes "Non-Clinical Testing" which is Finite Element Analysis (FEA). This is a computational method to analyze the mechanical behavior of the additional components, ensuring they do not create a "new worst-case scenario" compared to the predicate device. It's not a study with a test set, ground truth, experts, or statistical performance metrics.
    • There is no mention of an algorithm, AI, human readers, or any form of software performance evaluation.

    The document does state:

    • Device Name: Reliance Lumbar IBF System
    • Regulation Number: 21 CFR 888.3080
    • Regulation Name: Intervertebral body fusion device
    • Product Code: MAX
    • Predicate Devices: Reliance Lumbar IBF System (K113540) and Globus Patriot TransContinental System (K093242, K102313).
    • Intended Use/Indications for Use: Intervertebral body fusion of the spine in skeletally mature patients, with autogenous bone graft, intended for the lumbar spine (L2 to S1) for treatment of degenerative disc disease (DDD) with up to Grade 1 spondylolisthesis.
    • Device Description: Made of PEEK OPTIMA LT1 with Tantalum markers.
    • Non-Clinical Testing: Finite Element Analysis (FEA) was performed on additional components using Solidworks software and compared to test results of already approved components per K113540. No new components create a new worst-case scenario.

    In summary, none of the requested information regarding algorithm-specific acceptance criteria, study design parameters (sample size, data provenance, expert ground truth, adjudication, MRMC, standalone performance), or training set details can be provided from this document as it pertains to a physical implant and not an AI/software medical device.

    Ask a Question

    Ask a specific question about this device

    K Number
    K152131

    Validate with FDA (Live)

    Date Cleared
    2015-09-17

    (48 days)

    Product Code
    Regulation Number
    888.3070
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The RELIANCE Spinal Screw System is a pedicle screw systems intended to provide immobilization and stabilization of spinal segments in skeletally mature patients as an adjunct to fusion in the treatment of the following acute and chronic instabilities or deformities of the thoracic, lumbar, and sacral spine: degenerative spondylolisthesis with objective evidence of neurological impairment, fracture, dislocation, scoliosis, kyphosis, spinal tumor, and failed previous fusion (pseudarthrosis).

    The RELIANCE Spinal Screw System is also indicated for pedicle screw fixation for the treatment of severe degenerative spondylolisthesis (Grades 3 and 4) of the L5-S1 vertebra in skeletally-mature patients receiving fusion by autogenous bone graft and having implants attached to the lumbar and sacral spine (L3 to sacrum) with removal of the implants after the attainment of a solid fusion.

    When used posteriorly, the RELIANCE Spinal Screw System is also a hook and sacral/iliac screw fixation system of the noncervical spine indicated for: degenerative spondylolisthesis, trauma (fracture and/or dislocation), spinal stenosis, deformities (scoliosis, lordosis and/or kyphosis), tumor, and previous failed fusion (pseudarthrosis). Levels of fixation are for the thoracic, lumbar and sacral spine.

    The RELIANCE Spinal Screw System, when used with staples and two rods as an anterior thoracic/lumbar screw fixation system, is indicated for spondylolisthesis, trauma (fracture and/or dislocation), spinal stenosis, deformities (scoliosis and/or kyphosis), tumor, and previous failed fusion (pseudarthrosis).

    When used in a percutaneous, posterior approach with MIS instrumentation, the RELIANCE Spinal Screw System components are intended for noncervical pedicle fixation and nonpedicle fixation for the following indications: degenerative spondylolisthesis, trauma (i.e., fracture or dislocation), spinal stenosis, curvatures (i.e., scoliosis, kyphosis, and/or lordosis), tumor, pseudarthrosis, and failed previous fusion in skeletally-mature patients.

    Device Description

    The Posterior RELIANCE Spinal Screw System consists of longitudinal rods, monoaxial screws, polyaxial screws, reduction screws, cannulated polyaxial screws, cannulated reduction screws, hooks, reduction hooks, set screws and transverse connectors. The Anterior RELIANCE Spinal Screw System consists of two spinal rods, monoaxial screws, staples, and set screws. The Anterior RELIANCE staples and screws are intended to be attached to the lateral aspect of the vertebral bodies from T5 to L4, and SHOULD NOT be attached to the anterior aspect. Furthermore, only Titanium components should be used anteriorly.

    The RELIANCE Spinal Screw System components are available in titanium alloy conforming to ASTM F-136 specifications as well as stainless steel conforming to ASTM F-138 specifications. Furthermore, various rods of the RELIANCE Spinal Screw System are available in Cobalt-Chrome conforming to ASTM F-75 and ASTM F-1537 specifications. Components of the differing diameter rod systems are NOT interchangeable. The components of one material should not be used with components of another material with the exception that the Cobalt-Chrome rods may be used with titanium alloy implants. The extension tabs on the reduction screw and hook components are intended to be removed intraoperatively.

    AI/ML Overview

    The provided text describes a 510(k) premarket notification for a medical device called the "Reliance Spinal Screw System." This notification primarily focuses on establishing substantial equivalence to existing predicate devices based on material, intended use, size range, and strength. It also mentions non-clinical testing performed according to ASTM standards.

    However, the document does not contain the information requested regarding acceptance criteria and a study proving the device meets those criteria, as typically seen in detail for AI/software-driven medical devices. The Reliance Spinal Screw System is a physical orthopedic implant, not an AI/software device, and thus the type of information requested (e.g., sample sizes for test sets, expert ground truth, MRMC studies, standalone algorithm performance) is not applicable or present in this regulatory submission.

    Specifically, the document lacks details on:

    1. Acceptance criteria and reported device performance (in a table): The document states the device underwent "Non-Clinical Testing including Static Compressive, Static Torsion, and Dynamic Compressive in accordance with ASTM F1717," but it does not provide the specific acceptance criteria or the reported performance data from these tests.
    2. Sample sizes for test set and data provenance: Not applicable in the context of an orthopedic implant device.
    3. Number of experts and their qualifications for ground truth: Not applicable.
    4. Adjudication method: Not applicable.
    5. MRMC comparative effectiveness study and effect size: Not applicable as this is not an AI-assisted diagnostic device.
    6. Standalone algorithm performance: Not applicable.
    7. Type of ground truth used: Not applicable.
    8. Training set sample size: Not applicable.
    9. How ground truth for training set was established: Not applicable.

    The core of this 510(k) submission is to demonstrate that the expanded Reliance Spinal Screw System (with new screw types and rods) is substantially equivalent to previously cleared versions and other predicate devices, primarily through comparison of its physical characteristics, materials, indications for use, and a statement of compliance with mechanical testing standards (ASTM F1717). The results of these mechanical tests are not detailed in this publicly available summary.

    Ask a Question

    Ask a specific question about this device

    K Number
    K142269

    Validate with FDA (Live)

    Date Cleared
    2015-06-09

    (298 days)

    Product Code
    Regulation Number
    888.3080
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The RELIANCE CERVICAL IBF System is indicated for intervertebral body fusion of the spine in skeletally mature patients. The device systems are designed for use with autogenous bone graft to facilitate fusion. One device may be used per intervertebral space. The Reliance Cervical IBF and Reliance Cervical IBF-HA implants are intended to be used with legally cleared supplemental spinal fixation cleared for the implanted level.

    The RELIANCE CERVICAL IBF System is intended for use at one level in the cervical spine, from C3 to T1, for treatment of cervical disc disease (defined at neck pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies). The RELIANCE CERVICAL IBF System is to be used in patients who have six weeks of non-operative treatment.

    Device Description

    The Reliance Cervical IBF System is comprised of implants and instrument components. The implant component, the Reliance Cervical IBF device, is a spacer, which inserts between vertebral bodies in the anterior column of the cervical spine. The spacer may be made of PEEK Optima LT1 or PEEK Optima LT1-HA with Tantalum markers. The Reliance Cervical IBF System may also include bone screws to secure the device to the vertebral body.

    AI/ML Overview

    The provided text describes a 510(k) premarket notification for a medical device called the "Reliance Cervical IBF System." This document primarily focuses on demonstrating substantial equivalence to a predicate device through mechanical testing and an animal study, rather than establishing acceptance criteria and detailed performance against those criteria in a clinical study with human subjects.

    Therefore, many of the specific details requested in your prompt (such as acceptance criteria, sample size for test sets, number of experts for ground truth, adjudication methods, MRMC studies, standalone performance, and detailed training set information) are not directly present in this regulatory submission.

    However, I can extract and infer some information based on the provided text:

    Key Takeaway from the Document:

    The submission focuses heavily on substantial equivalence to previously cleared devices (K120396, K131429, and K142026) through mechanical testing and an animal study. It does not present detailed clinical efficacy or diagnostic performance data against specific acceptance criteria for a human clinical trial.

    Here's the breakdown of what can be extracted and what cannot:


    1. A table of acceptance criteria and the reported device performance

    • Acceptance Criteria: Not explicitly stated as pass/fail criteria in terms of clinical outcomes for human subjects. However, the document mentions adherence to specific ASTM standards for mechanical testing. These standards implicitly define acceptance criteria for the mechanical performance of intervertebral body fusion devices.
    • Reported Device Performance:
      • Mechanical Testing: Performed per ASTM F-2077 (Static and dynamic compression, static torsion, dynamic torsion), ASTM F-2267 (Expulsion), and ASTM Draft F-04.25.02.02 (Subsidence). The document states the device "was found to be substantially equivalent to itself" based on this testing, implying it met the performance expectations relative to its own prior clearance or the predicate devices. Specific quantitative results (e.g., maximum load, displacement) are not provided in this summary.
      • Animal Study: An "ovine fusion study was performed." No specific performance metrics or outcomes from this study are detailed in the provided text.
    Acceptance Criteria Category (Inferred from ASTM Standards)Reported Device Performance (Inferred/Summarized)
    Static Compression Strength (ASTM F-2077)Met, demonstrating substantial equivalence
    Dynamic Compression Endurance (ASTM F-2077)Met, demonstrating substantial equivalence
    Static Torsion Strength (ASTM F-2077)Met, demonstrating substantial equivalence
    Dynamic Torsion Endurance (ASTM F-2077)Met, demonstrating substantial equivalence
    Expulsion Resistance (ASTM F-2267)Met, demonstrating substantial equivalence
    Subsidence Resistance (ASTM Draft F-04.25.02.02)Met, demonstrating substantial equivalence
    Fusion in Animal Model (Ovine Fusion Study)Performed, result implies positive outcome for substantial equivalence

    2. Sample size used for the test set and the data provenance (e.g., country of origin of the data, retrospective or prospective)

    • Test Set Sample Size:
      • Mechanical Testing: Not specified in the summary. ASTM standards often specify the number of samples to be tested (e.g., n=6 for certain tests), but the exact count for this device is not here.
      • Animal Study: Not specified.
    • Data Provenance: Not specified, but generally, studies for U.S. FDA submissions are conducted under appropriate Good Laboratory Practice (GLP) standards, which implies a controlled testing environment, likely in the US or a country with equivalent regulatory oversight. The animal study would be prospective in nature, as would the mechanical testing.

    3. Number of experts used to establish the ground truth for the test set and the qualifications of those experts (e.g., radiologist with 10 years of experience)

    • Not Applicable: This information is not relevant to the type of studies described (mechanical testing and animal fusion study). These studies do not involve human expert interpretation for "ground truth" in the way a diagnostic AI device would. Mechanical tests rely on objective physical measurements and engineering analysis. Animal studies have veterinary pathologists or researchers assess outcomes.

    4. Adjudication method (e.g., 2+1, 3+1, none) for the test set

    • Not Applicable: No adjudication method is mentioned or relevant for mechanical testing or a preclinical animal study as described.

    5. If a multi reader multi case (MRMC) comparative effectiveness study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance

    • No: This is a mechanical device (cervical interbody fusion system), not an AI/diagnostic software. Therefore, an MRMC comparative effectiveness study for human readers with and without AI assistance is not applicable and was not performed.

    6. If a standalone (i.e. algorithm only without human-in-the-loop performance) was done

    • No: As this is a mechanical medical device, there is no "algorithm" or standalone AI performance to evaluate.

    7. The type of ground truth used (expert consensus, pathology, outcomes data, etc.)

    • Mechanical Testing: The "ground truth" is defined by the physical/mechanical properties and thresholds specified in the ASTM standards. Measurements are objective.
    • Animal Study: The "ground truth" for fusion in the ovine study would typically be established through methods like histological analysis (pathology), radiographic evidence (e.g., CT scans), and potentially biomechanical testing of explanted specimens. The document does not specify which methods were used, but pathology/imaging are standard for fusion assessment.

    8. The sample size for the training set

    • Not Applicable: This is not an AI/machine learning device. Therefore, there is no "training set" in the context of algorithm development.

    9. How the ground truth for the training set was established

    • Not Applicable: There is no training set for this device.

    In summary, the provided document is a 510(k) summary for a cervical interbody fusion device, showcasing substantial equivalence primarily through non-clinical (mechanical) testing and a pre-clinical animal study. It does not include the types of clinical performance data, acceptance criteria, or study designs typically associated with AI/diagnostic devices that would involve human readers, ground truth consensus, or large human clinical cohorts.

    Ask a Question

    Ask a specific question about this device

    K Number
    K142867

    Validate with FDA (Live)

    Date Cleared
    2015-04-29

    (210 days)

    Product Code
    Regulation Number
    888.3050
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The Reliance Posterior Cervical-Thoracic System is intended to promote fusion of the cervical spine and cervicothoracic junction (C1-T3), and is indicated for the following:

    • ddd (neck pain of discogenic origin with degeneration of the disc as confirmed by . patient history and radiographic studies)
    • Spondylolisthesis .
    • Spinal stenosis •
    • Fracture/dislocation •
    • Revision of previous cervical spine surgery .
    • . Tumors

    The use of the polyaxial screws is limited to placement in the upper thoracic spine (T1-T3) for anchoring the system only. They are not intended to be placed in the cervical spine.

    Hooks and Rods

    The rod and hook components are also intended to provide stabilization to promote fusion following reduction of fracture/dislocation or trauma in the cervical/upper thoracic (C1-T3) spine.

    WARNING: This device is not approved for screw attachment or fixation to the posterior elements (pedicles) of the cervical, thoracic (T4–T12), or lumbar spine. Pedicle screws are intended for placement only in T1-T3 as a means of anchoring the system.

    Device Description

    The Reliance Posterior Cervical-Thoracic System is comprised of implant and instrument components. The implant component, the Reliance Posterior Cervical-Thoracic device, consists of posterior attachment elements with a set screw and rod. The Posterior Cervical-Thoracic pedicle screw component is offered in a mono-axial configuration. In addition to this components, there are also ancillary components such as hooks, connectors, cross-links, and lateral offset connectors. There are also thoracic poly-axial screw components. Furthermore, the Reliance Posterior Cervical-Thoracic System has a variety of configurations to meet specific patients' needs.

    The Reliance Posterior Cervical-Thoracic instrument components include screw drivers, drill guides, plate holders, and drill bits. These instruments are manufactured from stainless steel, high grade plastic, and silicone rubber. There are also instrument trays that house these components.

    AI/ML Overview

    The provided document describes a medical device called the "Reliance Posterior Cervical-Thoracic System," for which the FDA is confirming substantial equivalence to a predicate device. This document does not describe the acceptance criteria and a study proving a device meets the acceptance criteria in the way a clinical trial or AI/ML performance study would.

    Instead, this document focuses on demonstrating substantial equivalence for a medical implant device, which involves showing that the new device is as safe and effective as a legally marketed predicate device. For this type of device, the "acceptance criteria" are typically met through non-clinical testing and comparison to predicate devices, rather than through studies involving human readers or expert consensus on observations.

    Here's an analysis based on the information provided, framed as closely as possible to your request, but acknowledging the different nature of this submission:

    1. Table of Acceptance Criteria and Reported Device Performance

    Acceptance Criteria (Non-Clinical)Reported Device Performance
    Static Compressive Strength (ASTM F1717)Tested and found substantially equivalent to predicate devices.
    Static Torsion Strength (ASTM F1717)Tested and found substantially equivalent to predicate devices.
    Dynamic Compressive Strength (ASTM F1717)Tested and found substantially equivalent to predicate devices.
    Dynamic Torsion Strength (ASTM F1717)Tested and found substantially equivalent to predicate devices.
    Sterilization Compatibility (ISO standards implied)Found substantially equivalent to predicate devices.
    Biocompatibility (ISO standards implied)Found substantially equivalent to predicate devices.
    Material equivalenceFound substantially equivalent to and itself (K122292), primary predicate device and the secondary predicate device, Synthes System & OC Fusion System (K141897).
    Intended Use equivalenceFound substantially equivalent to and itself (K122292), primary predicate device and the secondary predicate device, Synthes System & OC Fusion System (K141897).
    Levels of attachment equivalenceFound substantially equivalent to and itself (K122292), primary predicate device and the secondary predicate device, Synthes System & OC Fusion System (K141897).
    Size range equivalenceFound substantially equivalent to and itself (K122292), primary predicate device and the secondary predicate device, Synthes System & OC Fusion System (K141897).

    2. Sample Size Used for the Test Set and Data Provenance

    • Sample Size: Not explicitly stated as "sample size" in the context of clinical data for a test set. Instead, it refers to multiple test configurations for the mechanical testing of the device components. The number of samples tested for each mechanical property (e.g., number of constructs for static compressive testing) is not specified but would follow ASTM F1717 guidelines.
    • Data Provenance: The data is generated from non-clinical laboratory testing of the device prototypes. No human data (e.g., country of origin, retrospective/prospective) is involved in this described performance evaluation.

    3. Number of Experts Used to Establish Ground Truth for the Test Set and Qualifications

    • Not applicable in the context of this submission. The "ground truth" for the mechanical testing is based on the physical testing results against established international standards (ASTM F1717). No human experts are used to interpret clinical images or establish ground truth in a diagnostic sense for this type of submission.

    4. Adjudication Method for the Test Set

    • Not applicable. No adjudication method for a test set of clinical cases is described as this is not a study assessing diagnostic performance or human interpretation.

    5. If a Multi-Reader Multi-Case (MRMC) Comparative Effectiveness Study was done, and effect size.

    • Not applicable. This submission does not include an MRMC study. It is a premarket notification for a spinal fixation device, focusing on mechanical properties and substantial equivalence to existing devices, not on human diagnostic performance with or without AI assistance.

    6. If a standalone (i.e. algorithm only, without human-in-the-loop performance) was done

    • Not applicable. This device is a physical implant, not an algorithm or AI software. There is no standalone algorithm performance to evaluate.

    7. The Type of Ground Truth Used

    • The "ground truth" for the non-clinical performance evaluation is based on established engineering and biomechanical standards (ASTM F1717) and the performance characteristics of the identified predicate devices. This includes material properties, mechanical strength under various loads, sterilization, and biocompatibility.

    8. The Sample Size for the Training Set

    • Not applicable. This submission describes a physical medical device, not an AI/ML algorithm. Therefore, there is no "training set."

    9. How the Ground Truth for the Training Set was Established

    • Not applicable. As there is no training set for an AI/ML algorithm, this question is not relevant.

    In summary: The provided text details a 510(k) premarket notification for a spinal implant. The "acceptance criteria" discussed are related to the mechanical performance, materials, and intended use of the device, demonstrated through non-clinical testing and comparison to legally marketed predicate devices by showing "substantial equivalence." This is a different type of evaluation than those typically performed for AI-driven diagnostic devices.