510(k) Data Aggregation

    K Number
    K091459

    Validate with FDA (Live)

    Date Cleared
    2009-07-28

    (71 days)

    Product Code
    Regulation Number
    868.1850
    Age Range
    All
    Reference & Predicate Devices
    N/A
    Predicate For
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The intended use of the Philips NM3 monitor, Model 7900 is to provide:

    • cardiac output monitoring via the method of partial rebreathing in adult patients receiving mechanical ventilation during general anesthesia and in the intensive care unit (ICU).
    • spirometric, and carbon dioxide monitoring in neonatal, pediatric and adult patients during general anesthesia and in the intensive care unit (ICU) and the emergency department (ED). Separate combination CO2/flow sensors are provided for adult, pediatric and neonatal use.
    • continuous, non-invasive monitoring of functional arterial oxygen saturation and pulse rate in neonatal, pediatric and adult patients during both no motion conditions and for patients who are well or poorly perfused during general anesthesia and in the intensive care unit (ICU) and the emergency department (ED).

    The NM3 monitor Model 7900 and its sensors are intended to be used by trained operators when spirometric, capnographic, pulse oximetry, or cardiac output monitoring is indicated in the judgement of a physician.

    The use of the NM3 monitor Model 7900 for cardiac output monitoring is contraindicated in patients in which a small rise (3-5 mmHg) in their arterial partial pressure of CO2 level cannot be tolerated.

    Device Description

    The Philips NM3 monitor is intended for non-invasive monitoring of the inspired and expired airflow and airway pressure of intensive care unit (ICU), anesthesia and emergency room (ER) patients, as well as capnography and pulse oximetry in all of these clinical settings. It is intended to serve the same purposes as the flow, carbon dioxide and pulse oximetry monitoring components of the predicate NICO with MARS monitor.

    In the NM3 monitor as in the NCO system, combination CO2 adapter/flow sensors (neonatal, pediatric, adult), combination adult CO2 adapter/flow sensors with a partial rebreathing valve and flow sensors (infant/neonatal, pediatricladult) are connected with a male pneumatic connector to the NICO monitor. Sidestream airway adapters and nasal cannulas are available which are connected with a sample cell connector to a receptacle on the LoFlo Module which can be interfaced to the NM3 monitor. All of these sensors are already legally marketed as accessories of 510(k) cleared Respironics-Novametrix predicate devices. The pulse oximetry sensors are connected to the NM3 monitor via a connector on the front panel of the monitor. All of the pulse oximetry sensors are already legally marketed as accessories of 510(k) cleared Masimo predicate devices.

    The principal function of the flow portion of combination sensors and flow sensors is to provide a differential pressure signal related to flow and airway pressure relative to atmospheric pressure. These sensors are often placed in the breathing circuit between the endotracheal tube and the ventilator circuit Y piece and may also be used in conjunction with a face mask or mouthpiece. The flow measurement portion of the NM3 monitor is contained in the Mercury module which consists of a microprocessor-based data acquisition system that measures flow, and pressure and interfaces with a Capnostat 5 CO2 sensor. The CO2 airway adapter portion of the combination sensors, allow the Respironics-Novametrix CO2 mainstream gas sensor, the Capnostat® 5, to attach to it and measure the concentration of CO2 in the airway using infrared technology. When CO2 measurements are combined with airway flow and volume measurements, other parameters such as CO2 production and dead space can be calculated. The Capnostat 5 sensor as a mainstream gas analyzer includes a sample cell positioned in the breathing circuit through which a patient's inspiratory and expiratory gases flow. The LoFlo module, a sidestream type of gas analyzer, samples gases at 50 ml/min from a sampling port in an adapter placed in a breathing circuit or from a nasal or oral cannula. The gas then passes through a sampling tube to the sample cell, where the gas components are measured. The combination adult CO2 adapter/flow sensors with a partial rebreathing valve with periodic activation of the rebreathing valve allow pulmonary capillary blood flow and cardiac output to be calculated using the differential Fick method.

    AI/ML Overview

    I am unable to find the specific study and acceptance criteria within the provided text that would allow me to populate the table and fully answer all aspects of your request. The document is primarily a 510(k) summary for a medical device (Philips NM3 monitor), which outlines its intended use, technological characteristics, and substantial equivalence to a predicate device, but does not detail specific performance studies with acceptance criteria in the format requested.

    The document states that the device includes components (flow sensors, CO2 sensors, pulse oximetry sensors) that are "already legally marketed as accessories of 510(k) cleared Respironics-Novametrix predicate devices" or "Masimo predicate devices." This suggests that the performance validation for these components might have been conducted and cleared under those previous 510(k) submissions, and this current submission is for the integrated "Philips NM3 monitor" system.

    Therefore, many of the requested fields cannot be directly extracted from the provided text. To answer your complete request, information from detailed performance studies (which are typically part of a 510(k) submission but not fully contained in the summary provided) would be necessary.

    Ask a Question

    Ask a specific question about this device

    K Number
    K080652

    Validate with FDA (Live)

    Date Cleared
    2008-06-20

    (105 days)

    Product Code
    Regulation Number
    868.1850
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The intended use of the Mercury module with Capnostat 5 is to provide: spirometric, and carbon dioxide monitoring in neonatal, pediatric and adult patients during general anesthesia and in the intensive care unit (ICU) and the emergency department (ED). Separate combination CO2/flow sensors are provided for adult, pediatric and neonatal use.

    Device Description

    The Mercury module with Capnostat 5 is intended for non-invasive monitoring of the inspired and expired airflow and airway pressure of intention norminds for monthsive non emergency room (ER) patients, as well as capnography in all of these clinical settings. It is intended to serve the same purposes as the flow and carbon dioxide monitoring component of the NICO monitor. The Mercury module with Capnostat 5 is the flow and carbon dioxide monitoring component of the presently 510(k) cleared NICO with MARS monitor. It has been designed to include all of the functionality of the flow and carbon dioxide monitoring components of NCO with CO massurament workilling for a with Capnostat 5 is intended to provide all of the existing flow and CO2 measurement capabilities of the NICO Model 7300 of continuous monitoring of respiratory flow and pressure, and CO2 during anesthesia and intensive care and in the emergency department. The flow sensors connect to a patient airway circuit and provide physiological information to the Mercury module. The parameters directly measured and computed by the module (when connected to a Capnostal 5 sensor) include airway flow and pressure, volume, and CO2. The monitor calculates flow by measuring the pressure drop across a known resistance placed in the breathing circuit. CO2 is measured as the absorption of a known intensity of infrared light by CO2 molecules in the airway.

    AI/ML Overview

    The provided document does not contain information about the acceptance criteria or a study proving the device meets acceptance criteria. The document is a 510(k) summary for the Mercury Module with Capnostat 5 CO2 Sensor, primarily focusing on its substantial equivalence to a predicate device and its intended use. It does not detail specific performance studies, acceptance criteria, or the methodology for proving these criteria.

    Therefore, I cannot populate the requested table or answer the specific questions about sample size, data provenance, expert qualifications, adjudication methods, MRMC studies, standalone performance, ground truth types, or training set details based on the provided text.

    Ask a Question

    Ask a specific question about this device

    K Number
    K053174

    Validate with FDA (Live)

    Date Cleared
    2006-01-12

    (59 days)

    Product Code
    Regulation Number
    868.1400
    Age Range
    All
    Reference & Predicate Devices
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The intended use of the LoFlo C5 CO2 sensor is to provide carbon dioxide monitoring to a host monitoring system during anesthesia / recovery, in the intensive care unit (ICU), and in Emergency Medicine/Transport or Respiratory care.

    Device Description

    The LoFlo C5 CO2 sensor is designed for continuous, non-invasive sidestream monitoring of carbon dioxide. Carbon dioxide is measured on-airway using an infrared absorption (IR) technique. The airway adapters and associated nasal cannulas are already legally marketed as accessories to the predicate device. The LoFlo C5 CO2 sensor is an integrated microprocessor based data acquisition system consisting of CO2 measurement, control circuitry and a high speed serial interface. The LoFlo C5 CO2 sensor uses SRAM for data storage and an EEPROM to store system parameters. The firmware resides in a PROM. The operations performed by the LoFlo C5 CO2 sensor include data acquisition, parameter calculation, zeroing, heater control and corrections to the CO2 signal for N2O, O2 and barometric pressure.

    AI/ML Overview

    The provided text is a 510(k) summary for a medical device (LoFlo C5 CO2 Sensor) and does not contain detailed information about acceptance criteria or specific study results that prove the device meets acceptance criteria. The document mainly focuses on describing the device, its intended use, technological characteristics, and its substantial equivalence to a predicate device.

    Therefore, I cannot extract the requested information about acceptance criteria and study details from this document.

    The following information is NOT available in the provided text:

    1. A table of acceptance criteria and the reported device performance: The document does not specify any quantitative acceptance criteria or report performance metrics against such criteria.
    2. Sample size used for the test set and the data provenance: No information on test set sample sizes or data provenance (country of origin, retrospective/prospective) is provided.
    3. Number of experts used to establish the ground truth for the test set and the qualifications of those experts: The concept of "ground truth" and expert involvement for a test set is not discussed.
    4. Adjudication method for the test set: No information is given regarding adjudication methods.
    5. If a multi-reader multi-case (MRMC) comparative effectiveness study was done, and the effect size: MRMC studies and effect sizes are not mentioned.
    6. If a standalone study (algorithm only without human-in-the-loop performance) was done: Standalone performance testing is not detailed.
    7. The type of ground truth used: The establishment of ground truth is not described.
    8. The sample size for the training set: Training set information is not provided.
    9. How the ground truth for the training set was established: Ground truth establishment for a training set is not discussed.