510(k) Data Aggregation

    K Number
    K120245

    Validate with FDA (Live)

    Manufacturer
    Date Cleared
    2012-06-21

    (146 days)

    Product Code
    Regulation Number
    884.5460
    Reference & Predicate Devices
    Predicate For
    N/A
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    Playtex® Gentle Glide Scented menstrual tampons are intended to be inserted into the vagina and used to absorb menstrual fluid.

    Playtex® Gentle Glide Unscented menstrual tampons are intended to be inserted into the vagina and used to absorb menstrual fluid.

    Absorbency Ranges:

    Absorbs menstrual flow < 6 grams (Slender Light)

    Absorbs menstrual flow 6-9 grams (Slender Regular, Regular)

    Absorbs menstrual flow 9-12 grams (Super)

    Absorbs menstrual flow 12-15 grams (Super Plus)

    Absorbs menstrual flow 15-18 grams (Ultra)

    Device Description

    Scented or scented deodorized, unscented menstrual tampons for the absorption of menstrual fluid.

    AI/ML Overview

    The Playtex® Gentle Glide Scented and Unscented Tampons (K120245) have specific acceptance criteria related to absorbency, which were verified through performance testing.

    1. Table of Acceptance Criteria and Reported Device Performance

    Acceptance Criteria (Absorbency Range per 21 CFR §801.430(f)(2))Reported Device Performance (Absorbency Grams)
    Slender Light< 6 grams (Absorbs menstrual flow)
    Slender Regular, Regular6-9 grams (Absorbs menstrual flow)
    Super9-12 grams (Absorbs menstrual flow)
    Super Plus12-15 grams (Absorbs menstrual flow)
    Ultra15-18 grams (Absorbs menstrual flow)

    The device meets these acceptance criteria, as stated in the performance testing section: "Syngyna testing was conducted in accordance to 21 CFR §801.430(f)(2) to verify that the modified tampons met absorbency ranges as specified in the regulation."

    2. Sample Size Used for the Test Set and Data Provenance

    The document does not explicitly state the specific sample size for the "Syngyna testing" (absorbency testing) or the biocompatibility tests. It only mentions that these tests were "conducted." The data provenance (e.g., country of origin, retrospective/prospective) is also not specified for these tests.

    3. Number of Experts Used to Establish the Ground Truth for the Test Set and Their Qualifications

    Since this device is a menstrual tampon and the primary performance testing involves absorbency measurements, there isn't a "ground truth" derived from expert consensus in the same way it would be for a diagnostic AI device. The ground truth for absorbency is established by the standardized Syngyna testing method itself, as defined by 21 CFR §801.430(f)(2).

    For the biocompatibility tests (preclinical and clinical), these are standard in vitro and in vivo tests that would be conducted by trained laboratory personnel, but not "experts" in the sense of clinicians establishing ground truth for a diagnostic outcome.

    4. Adjudication Method for the Test Set

    Not applicable. The absorbency tests are objective measurements, and biocompatibility tests involve standardized protocols and observations. There is no mention of an adjudication method.

    5. If a Multi-Reader Multi-Case (MRMC) Comparative Effectiveness Study Was Done, and Effect Size

    Not applicable. This is a medical device (menstrual tampon), not a diagnostic AI software. Therefore, an MRMC comparative effectiveness study involving human readers with or without AI assistance is not relevant to this submission.

    6. If a Standalone (Algorithm Only Without Human-in-the-Loop Performance) Was Done

    Not applicable. This is a physical medical device, not a software algorithm.

    7. The Type of Ground Truth Used

    The ground truth for the absorbency performance is based on objective measurements obtained through the standardized Syngyna testing method, as mandated by federal regulation (21 CFR §801.430(f)(2)).

    For the biocompatibility tests, the ground truth is established through standard laboratory test results (e.g., cytotoxicity, irritation, sensitization, TSS).

    8. The Sample Size for the Training Set

    Not applicable. This is a physical medical device. There is no concept of a "training set" in the context of its development and testing as described in this 510(k) summary.

    9. How the Ground Truth for the Training Set Was Established

    Not applicable, as there is no training set for this type of device.

    Ask a Question

    Ask a specific question about this device

    K Number
    K980478

    Validate with FDA (Live)

    Manufacturer
    Date Cleared
    1998-04-03

    (56 days)

    Product Code
    Regulation Number
    884.5470
    Reference & Predicate Devices
    Predicate For
    N/A
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    Unscented menstrual tampons for absorption of menstrual fluid.

    Device Description

    Not Found

    AI/ML Overview

    This document describes a 510(k) submission for Playtex Tampons (K980478), focusing on safety and effectiveness tests rather than AI/machine learning device performance. Therefore, many of the requested categories related to AI models, such as sample size for test sets, number of experts for ground truth, adjudication methods, multi-reader multi-case studies, standalone performance, and training set information, are not applicable.

    Here's a breakdown of the available information:

    1. Table of Acceptance Criteria and Reported Device Performance

    Acceptance CriteriaReported Device Performance
    Dioxin AnalysisNot explicitly stated as "passing" or "failing"; implies compliance as part of the overall acceptance.
    Primary Dermal Irritation (Rabbits)Non-Irritating
    Acute Oral Toxicity (Rats)Non-Toxic
    Subacute Vaginal Irritation (Rabbits)Non-Irritating
    Agar Diffusion StudyNo zones of inhibition were detected
    TSST-1, Toxin TestingResults in the range of values of commercially sold tampons (previously conducted on the same rayon pledget submitted in K971174)
    Human Repeat Insult Patch Test (200 persons)Implies no significant safety issues, as it contributed to the overall substantial equivalence finding.

    2. Sample Size Used for the Test Set and Data Provenance

    • Sample Size:
      • Primary Dermal Irritation: Not specified, but "Rabbits" plural implies more than one.
      • Acute Oral Toxicity: Not specified, but "Rats" plural implies more than one.
      • Subacute Vaginal Irritation: Not specified, but "Rabbits" plural implies more than one.
      • Human Repeat Insult Patch Test: 200 persons.
    • Data Provenance: Not specified, but assumed to be internal laboratory testing or contract research organization testing for the manufacturer (Playtex). Retrospective or prospective is not clearly stated but typical in vivo/in vitro testing for device clearance is prospective.

    3. Number of Experts Used to Establish the Ground Truth for the Test Set and Qualifications of Those Experts

    Not applicable. The "ground truth" for these types of tests (e.g., irritation, toxicity) is based on standard biological and chemical assays and established scientific protocols, not expert consensus interpreting results. The experts involved would be laboratory scientists and toxicologists.

    4. Adjudication Method for the Test Set

    Not applicable. Results are based on objective measurements and established protocols for biological and chemical assays.

    5. If a Multi Reader Multi Case (MRMC) Comparative Effectiveness Study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance

    Not applicable. This is not an AI/machine learning device.

    6. If a Standalone (i.e. algorithm only without human-in-the-loop performance) was done

    Not applicable. This is not an AI/machine learning device.

    7. The Type of Ground Truth Used

    The ground truth is based on:

    • In vitro/In vivo biological assays: For irritation, toxicity, and inhibition studies, ground truth is determined by the direct observed biological response or lack thereof according to established scientific methodologies and endpoints.
    • Chemical analysis: For Dioxin analysis, ground truth is determined by chemical quantification against established limits.
    • Toxin quantification: For TSST-1, ground truth is determined by laboratory methods to measure toxin levels.

    8. The Sample Size for the Training Set

    Not applicable. This is not an AI/machine learning device.

    9. How the Ground Truth for the Training Set was Established

    Not applicable. This is not an AI/machine learning device.

    Ask a Question

    Ask a specific question about this device

    K Number
    K971174

    Validate with FDA (Live)

    Manufacturer
    Date Cleared
    1997-05-21

    (51 days)

    Product Code
    Regulation Number
    884.5470
    Reference & Predicate Devices
    N/A
    Predicate For
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    Unscented menstrual tampons for the absorption of menstrual fluid.

    Device Description

    Unscented menstrual tampons for the absorption of menstrual fluid.

    AI/ML Overview

    The provided text describes a 510(k) submission for Playtex Tampons, specifically addressing their substantial equivalence to previously cleared Playtex Gentle Glide Tampons. It does not contain information about the acceptance criteria or a study that proves the device meets specific acceptance criteria in the format requested.

    The document states:

    • Device Name: Playtex Tampons (Unscented Menstrual Tampons)
    • Predicate Device: Previously cleared Playtex Gentle Glide Tampons, Regular, Super and Super Plus.
    • Intended Use: Unscented menstrual tampons for the absorption of menstrual fluid.
    • Technological Characteristics: The new tampon has the same technological characteristics as the predicate device (fiber, string, materials in contact with the vaginal wall, and mode of action are the same).
    • Nonclinical Testing: Dioxin analysis, dermal irritation, acute oral toxicity, subacute vaginal irritations, agar diffusion, and TSST-1 toxin testing.
    • Conclusion: The Playtex Tampons are substantially equivalent to the predicate device in terms of safety and effectiveness based on the review of the data.

    Therefore, I cannot populate the table or provide information for the specific points you requested, as the document focuses on demonstrating substantial equivalence rather than reporting on specific performance acceptance criteria from a study.

    The document indicates that the determination of safety and effectiveness was based on the nonclinical testing mentioned above and a comparison to the predicate device. It does not describe a clinical study with a test set, ground truth, or statistical analysis of performance metrics against predefined acceptance criteria for the new device.

    Ask a Question

    Ask a specific question about this device

    Page 1 of 1