510(k) Data Aggregation

    K Number
    K972509

    Validate with FDA (Live)

    Date Cleared
    1997-09-08

    (67 days)

    Product Code
    Regulation Number
    892.1200
    Age Range
    All
    Reference & Predicate Devices
    N/A
    Predicate For
    N/A
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    This software program should be used to guantitatively analyze the myocardial perfusion of patients' who have been injected with Cardiolite® (Technetium Tc99m Sestamibi) for a rest/stress same-day Single Photon Emission Computerized Tomography (SPECT) acquisition protocol. Cardiolite®, Kit for the Preparation of Technetium Tc99m Sestamibi is a myocardial perfusion agent that is useful in the evaluation of ischemic heart disease. Cardiolite®, Kit for the Preparation of Technetium Tc99m Sestamibi is useful in distinguishing normal from abnormal myocardium and in the localization of the abnormality, in patients with suspected myocardial infarction, ischemic heart disease or Evaluation of ischemic heart disease or coronary artery disease. coronary artery disease is accomplished using rest and stress techniques.

    Cardiolite®, Kit for the Preparation of Technetium Tc99m Sestamibi is also useful in the evaluation of myocardial function using the first pass technique.

    Rest-exercise imaging with Tc99m Sestamibi in conjunction with other diagnostic information may be used to evaluate ischemic heart disease and its localization.

    In clinical trials, using a template consisting of the anterior wall, inferior-posterior wall and isolated apex, localization in the anterior or inferior-posterior wall in patients with suspected angina pectoris or coronary artery disease was shown. Disease localization isolated to the apex has not been established. Tc99m Sestamibi has not been studied or evaluated in other cardiac diseases.

    It is usually not possible to differentiate recent from old myocardial infarction or to differentiate recent myocardial infarction from ischemia.

    To detect or image the distribution of radionuclides in the body or organ, using the following technique(s). Tomographic imaging (SPECT) for non Positron emitter.

    Device Description

    This medical device (CEqual®) is a diagnostic software program that quantitatively analyzes the myocardial perfusion of patients' injected with Cardiolite® (99mTc Sestamibi) following a rest/stress same-day SPECT acquisition protocol. The algorithm automatically determines the processing parameters and, following operator verification of these parameters, samples the myocardium using maximum count profiles. These stress and rest profiles are then used to generate relative count "raw data" polar maps. In addition, the profiles are compared to a normal data base and the results of this comparison are used to generate quantitative stress and rest polar maps which indicate defect extent, severity, and reversibility for all abnormal perfusion areas of the patients' study. The final results are presented in the form of polar maps as well as a table indicating the % abnormal pixels in territories supplied by the left anterior descending, left circumflex, and right coronary arteries.

    AI/ML Overview

    The provided text describes the CEqual® software, a diagnostic program that quantitatively analyzes myocardial perfusion from SPECT acquisitions using Cardiolite® (Technetium Tc99m Sestamibi). The software generates polar maps indicating defect extent, severity, and reversibility, and a table showing the percentage of abnormal pixels in territories supplied by major coronary arteries.

    Here is an analysis of the provided information:

    1. Table of Acceptance Criteria and Reported Device Performance

    The document does not explicitly state formal acceptance criteria with specific threshold values for performance metrics (e.g., sensitivity, specificity, accuracy). Instead, it states that "The accuracy results obtained with this program are similar to those obtained with previous quantitative analysis programs of the TI-201 myocardial perfusion agent (1,2) and Cardiolite® (3,4)." This implies that the acceptance criterion was likely non-inferiority or comparable performance to existing, legally marketed predicate devices rather than meeting a specific numerical target.

    Performance MetricAcceptance Criteria (Implied)Reported Device Performance
    AccuracyComparable to established quantitative analysis programs for Tl-201 and Cardiolite® myocardial perfusion agents."The accuracy results obtained with this program are similar to those obtained with previous quantitative analysis programs of the TI-201 myocardial perfusion agent (1,2) and Cardiolite® (3,4)."

    2. Sample Size Used for the Test Set and Data Provenance

    • Test Set Sample Size: 35 patients.
    • Data Provenance: The study was a "prospective validation which included 35 patients acquired and processed at another institution." This indicates the data was prospective and collected from an institution different from the developers. The country of origin is not specified, but the references suggest it was likely within the United States, given the authors and journals.

    3. Number of Experts Used to Establish the Ground Truth for the Test Set and Their Qualifications

    The document does not specify the number of experts used or their qualifications for establishing the ground truth for the test set.

    4. Adjudication Method for the Test Set

    The adjudication method for the test set is not specified in the provided text.

    5. If a Multi-Reader Multi-Case (MRMC) Comparative Effectiveness Study Was Done

    A Multi-Reader Multi-Case (MRMC) comparative effectiveness study was not explicitly stated as part of this device's validation. The focus was on the software's performance itself rather than human reader improvement with AI assistance. The text mentions the program is an "adjunctive diagnostic tool" and not meant to replace visual analysis, suggesting it's for human-in-the-loop use but doesn't quantify reader improvement.

    6. If a Standalone Study Was Done

    Yes, a standalone study was done. The description "The effectiveness of the program has been established in a prospective validation which included 35 patients acquired and processed at another institution" refers to the algorithm's performance as a standalone tool, comparing its quantitative results against some form of ground truth (or established accuracy benchmarks of predicate devices as per the acceptance criteria).

    7. The Type of Ground Truth Used

    The specific type of ground truth used to evaluate the 35 patients in the prospective validation is not explicitly stated. However, given the context of myocardial perfusion imaging for "evaluation of ischemic heart disease or coronary artery disease" and localization of abnormalities, common ground truth types in such studies include:

    • Expert Consensus: Visual interpretation by experienced cardiologists or nuclear medicine physicians.
    • Coronary Angiography: An invasive procedure considered the gold standard for anatomical assessment of coronary artery disease.
    • Clinical Outcomes: Follow-up data on patient events (e.g., myocardial infarction, revascularization).

    The reference to "previous quantitative analysis programs" suggests the ground truth was comparable to what was used in those studies, which often involves a combination of expert visual assessment and, for more definitive studies, angiography.

    8. The Sample Size for the Training Set

    The document does not specify the sample size used for the training set. It mentions "a normal data base" used to generate quantitative stress and rest polar maps, implying a training or reference set was used, but the size is not provided.

    9. How the Ground Truth for the Training Set Was Established

    The document states that the software compares patient profiles "to a normal data base." This "normal data base" serves as a reference for quantifying abnormalities. How the ground truth for this normal data base was established is not explicitly detailed. It can be inferred that this database would consist of studies from individuals confirmed to have normal myocardial perfusion, likely established through:

    • Absence of clinical symptoms of cardiac disease.
    • Normal findings on other diagnostic tests (e.g., EKG, echocardiogram).
    • Possibly, follow-up to ensure no cardiac events.
    • Expert interpretation confirming normalcy.

    The references provided (1, 2, 3, 4) might contain more details about the methodology for creating such "normal databases" in studies of similar quantitative myocardial perfusion agents. For example, Van Train et al. (1993, Ref 3) specifically mentions "definition and validation of stress normal limits," which would involve establishing the ground truth for a normal cohort.

    Ask a Question

    Ask a specific question about this device

    K Number
    K970288

    Validate with FDA (Live)

    Date Cleared
    1997-04-24

    (90 days)

    Product Code
    Regulation Number
    892.1200
    Age Range
    All
    Reference & Predicate Devices
    N/A
    Predicate For
    N/A
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    This software program should be used to quantitatively analyze the myocardial perfusion of patients' who have been injected with Cardiolite® (Technetium Tc99m Sestamibi) for a rest/stress same-day Single Photon Emission Computerized Tomography (SPECT) acquisition protocol. Cardiolite®, Kit for the Preparation of Technetium Tc99m Sestamibi is a myocardial perfusion agent that is useful in the evaluation of ischemic heart disease. Technetium Tc99m Sestamibi is useful in distinguishing normal from abnormal myocardium and in the localization of the abnormality, in patients with suspected myocardial infarction, ischemic heart disease or coronary artery disease. Evaluation of ischemic heart disease or coronary artery disease is accomplished using rest and stress techniques.

    Preparation of Technetium Tc99m Sestamibi is also useful in the evaluation of myocardial function using the first pass technique.

    Rest-exercise imaging with Tc99m Sestamibi in conjunction with other diagnostic information may be used to evaluate ischemic heart disease and its localization.

    In clinical trials, using a template consisting of the anterior wall, inferior-posterior wall and isolated apex, localization in the anterior or inferior-posterior wall in patients with suspected angina pectoris or coronary artery disease was shown. Disease localization isolated to the apex has not been established. Tc99m Sestamibi has not been studied or evaluated in other cardiac diseases.

    It is usually not possible to differentiate recent from old myocardial infarction or to differentiate recent myocardial infarction from ischemia.

    Device Description

    This medical device (CEqual®) is a diagnostic software program that quantitatively analyzes the myocardial perfusion of patients' injected with Cardiolite® (99mTc Sestamibi) following a rest/stress same-day SPECT acquisition protocol. The algorithm automatically determines the processing parameters and, following operator verification of these parameters, samples the myocardium using maximum count profiles. These stress and rest profiles are then used to generate relative count "raw data" polar maps. In addition, the profiles are compared to a normal data base and the results of this comparison are used to generate quantitative stress and rest polar maps which indicate defect extent, severity, and reversibility for all abnormal perfusion areas of the patients' study. The final results are presented in the form of polar maps as well as a table indicating the % abnormal pixels in territories supplied by the left anterior descending, left circumflex, and right coronary arteries.

    AI/ML Overview

    Here's an analysis of the acceptance criteria and the study proving the device meets them, based on the provided text:

    Acceptance Criteria and Device Performance

    The provided text does not explicitly state specific numerical acceptance criteria (e.g., sensitivity > X%, specificity > Y%). Instead, it refers to the program's accuracy being "similar to those obtained with previous quantitative analysis programs." It describes the intended function of the device and its role as an adjunctive diagnostic tool.

    However, based on the "Effectiveness" section, we can infer a general acceptance criterion related to its performance being comparable to established methods.

    Acceptance Criteria (Inferred)Reported Device Performance
    Provides quantitative analysis of myocardial perfusionAutomatically determines processing parameters, samples myocardium using maximum count profiles, generates relative count "raw data" polar maps, compares to a normal database to generate quantitative stress/rest polar maps, indicates defect extent, severity, and reversibility, provides a table of % abnormal pixels in specific arterial territories.
    Accuracy similar to existing quantitative analysis programs (e.g., Tl-201 and Cardiolite®)"The accuracy results obtained with this program are similar to those obtained with previous quantitative analysis programs of the Tl-201 myocardial perfusion agent (1,2) and Cardiolite® (3,4)."
    Functions as an adjunctive diagnostic tool"The intent of this program was to provide the physician with an adjunctive diagnostic tool to aid in the diagnostic interpretation of the patients' Cardiolite® same-day study."

    Study Details

    1. Sample size used for the test set and the data provenance:

      • Test Set Sample Size: 35 patients.
      • Data Provenance: The data was "acquired and processed at another institution," indicating an external, prospective collection. The country of origin is not specified, but the references are primarily from US-based journals and institutions, suggesting US origin.
      • Retrospective or Prospective: Prospective validation.
    2. Number of experts used to establish the ground truth for the test set and the qualifications of those experts:

      • This information is not provided in the document. The text states "The effectiveness of the program has been established in a prospective validation which included 35 patients," but does not detail how ground truth for these 35 patients was established. The references listed (especially the multi-center trials for Tl-201 and Technetium-99m sestamibi) likely used expert interpretation, but this is not explicitly linked to the ground truth of this specific 35-patient validation study.
    3. Adjudication method for the test set:

      • This information is not provided in the document.
    4. If a multi reader multi case (MRMC) comparative effectiveness study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance:

      • A formal MRMC comparative effectiveness study was not described for this specific device's validation. The text clarifies, "It was not meant to replace or eliminate the standard visual analysis of the Cardiolite® images," indicating it's an adjunctive tool. The study focuses on the standalone performance of the algorithm itself in comparison to established methods, not on human reader improvement with AI assistance.
    5. If a standalone (i.e. algorithm only without human-in-the-loop performance) was done:

      • Yes, a standalone validation was done. The described "prospective validation which included 35 patients" assesses the "accuracy results obtained with this program," implying the algorithm's direct output was evaluated. The comparison is made to the accuracy of previous quantitative analysis programs, which are also standalone algorithms.
    6. The type of ground truth used (expert consensus, pathology, outcomes data, etc.):

      • This information is not explicitly stated for the 35-patient validation study. Given the nature of myocardial perfusion studies, the ground truth for diagnosing ischemic heart disease or coronary artery disease in the broader context often involves a combination of clinical assessment, invasive angiography (coronary artery disease status), follow-up for cardiac events (outcomes data), or expert interpretation of the gold standard imaging itself (though this creates a circularly dependent ground truth). The references (especially Van Train et al., 1993, 1994) imply "definition and validation of stress normal limits and criteria for abnormality," which would likely involve expert consensus and correlation with other diagnostic findings, but this isn't clarified for the 35 patients.
    7. The sample size for the training set:

      • The document does not provide a specific sample size for the training set. It refers to the program using a "normal data base" for comparison, which would be derived from a training or reference set, but its size is not mentioned. The references, particularly Van Train et al., 1993, describe building "normal limits," which would involve a cohort of healthy individuals.
    8. How the ground truth for the training set was established:

      • This is not explicitly detailed for a "training set" in the context of this document. However, the mention of comparing to "a normal data base" implies that this database was established with a ground truth representing normal myocardial perfusion. Based on the references, it's highly probable this involved:
        • Expert Consensus/Clinical Criteria: Normal limits are typically established using a cohort of individuals with a low likelihood of coronary artery disease, confirmed by clinical assessment, normal ECG, and possibly other tests.
        • Angiography (Absence of Disease): For "normal limits" in the context of perfusion, individuals often undergo coronary angiography to confirm the absence of significant coronary artery disease.
        • Follow-up Outcomes: Long-term follow-up confirming the absence of cardiac events can also define a "normal" population.
      • Reference 3 specifically mentions "definition and validation of stress normal limits and criteria for abnormality," which is a key process for establishing the ground truth for such a normal database.