510(k) Data Aggregation

    K Number
    K070622

    Validate with FDA (Live)

    Date Cleared
    2007-08-14

    (161 days)

    Product Code
    Regulation Number
    876.1500
    Reference & Predicate Devices
    Predicate For
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The NeoGuide Endoscopy System is intended to provide visualization and diagnostic / therapeutic access to the adult lower gastrointestinal tract (including, but not limited to, the anus, rectum, sigmoid colon, colon, cecum and ileocecal valve) for endoscopy and endoscopic surgery.

    Device Description

    The NeoGuide colonoscope is manually inserted and withdrawn by the physician, who steers and controls it using the electromechanical controls located at the handle. The colonoscope distal tip is equipped with a CCD camera and fiber optic illumination bundles for procedural illumination and includes a standard tool channel for therapeutic procedures. Valves control insuflation air, water irrigation, and suction. The NeoGuide Colonoscope incorporates fifteen active electro-mechanically controlled segments, not including the tip. During a procedure, the segments shape conforms to the path defined by the physician as the tip is manually steered but electromechanically controlled through the colon lumen. Each of the active segments uses four control cables to articulate in the up/down and left/right directions. This mechanism of action is the same as the mechanism used in conventional colonoscope steerable tips. The NeoGuide Endoscopy System displays a graphical representation of the system interpretation of the tip movements commanded by the physician and the depth of insertion of the colonoscope into the patient.

    AI/ML Overview

    I am sorry, but the provided text does not contain any information about acceptance criteria, device performance, a study, or any of the other specific details requested. The document is a 510(k) premarket notification summary and an FDA clearance letter for the NeoGuide Endoscopy System.

    It describes the device, its intended use, and compares it to predicate devices to establish substantial equivalence. However, it does not include data from a performance study against specific acceptance criteria.

    Therefore, I cannot provide the requested information based on the given input.

    Ask a Question

    Ask a specific question about this device

    K Number
    K052930

    Validate with FDA (Live)

    Date Cleared
    2006-01-31

    (104 days)

    Product Code
    Regulation Number
    876.1500
    Reference & Predicate Devices
    Predicate For
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The NeoGuide Endoscopy System is intended to provide visualization and diagnostic / therapeutic access to the adult lower gastrointestinal tract (including, but not limited to, the anus, rectum, sigmoid colon, colon, cecum and ileocecal valve) for endoscopy and endoscopic surgery.

    Device Description

    The NeoGuide Endoscopy System has many features in common with currently marketed colonoscopes. The colonoscope is manually inserted and withdrawn by the physicial, who manually steers and controls it using up/down and left/right steering control knobs on a handle. The colonoscope distal tip is equipped with a CCD camera and fiber optic illumination bundles for procedural illumination. A standard tool channel is incorporated for therapeutic procedures, as well as valves to control insuflation air, water irrigation, and suction.

    The NeoGuide Colonoscope differs from currently marketed colonoscopes in that it incorporates fifteen active electro-mechanically controlled segments designed to allow the shape of the insertion tube to conform to the path defined by the physician as the colonoscope tip is manually steered through the colon lumen. The active segments are similar to conventional colonoscope steerable tips, as they each employ four control cables to articulate in the up/down and left/right directions. In order to determine the path selected by the physician during a procedure, the NeoGuide endoscopy system incorporates transducers that measure the angle of articulation of the steerable tip and the depth of insertion of the colonoscope into the patient. Software is required to create an anatomical map and interpret, monitor, and control the insertion tube segments.

    AI/ML Overview

    Here's a breakdown of the requested information based on the provided text. Unfortunately, the provided text does not contain detailed acceptance criteria or the specific study details that "prove" the device meets them. The document is primarily a 510(k) summary and an FDA clearance letter, which focuses on demonstrating substantial equivalence to predicate devices rather than proving performance against specific acceptance criteria through a detailed clinical study report.

    Therefore, many sections below will indicate that the information is not available in the provided text.


    Acceptance Criteria and Device Performance

    1. Table of Acceptance Criteria and Reported Device Performance

    Acceptance CriteriaReported Device Performance
    Not AvailableNot Available
    (e.g., specific metrics like insertion success rate, procedure time reduction, diagnostic accuracy for specific pathologies are not provided in this document.)(The document states the device has been shown to be "substantially equivalent" to currently marketed predicate devices based on in vitro bench, in vivo animal, and clinical studies, but does not detail the results of these studies against specific performance metrics.)

    Explanation: The 510(k) summary and FDA letter do not list explicit acceptance criteria for performance metrics. The clearance is based on substantial equivalence, implying that the device's performance is expected to be comparable to its predicates, but no specific numerical targets or results are presented in this document.

    2. Sample size used for the test set and the data provenance

    • Sample Size (Test Set): Not available in the provided text. The document mentions "clinical study" but does not specify the sample size for a test set.
    • Data Provenance: Not available in the provided text. The document mentions "clinical study" but does not specify the country of origin of the data or whether it was retrospective or prospective.

    3. Number of experts used to establish the ground truth for the test set and the qualifications of those experts

    • Number of Experts: Not available in the provided text.
    • Qualifications of Experts: Not available in the provided text.

    4. Adjudication method for the test set

    • Adjudication Method: Not available in the provided text.

    5. If a multi-reader multi-case (MRMC) comparative effectiveness study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance

    • MRMC Study: Not applicable. The NeoGuide Endoscopy System is a colonoscope with electro-mechanically controlled segments, not an AI-based diagnostic tool that assists human readers in interpreting images. Therefore, the concept of human readers improving with AI assistance does not apply to this device. The document describes a colonoscope that is "manually inserted and withdrawn by the physician, who manually steers and controls it."

    6. If a standalone (i.e., algorithm only without human-in-the-loop performance) was done

    • Standalone Performance: Not applicable. As noted above, this is a physical medical device (colonoscope) operated by a physician, not an algorithm, so standalone performance in the context of AI is not relevant.

    7. The type of ground truth used (expert consensus, pathology, outcomes data, etc.)

    • Type of Ground Truth: Not available in the provided text. The document refers to "in vitro bench, in vivo animal and clinical study" but does not describe how ground truth was established within these studies. For a colonoscope, relevant ground truth might involve successful navigation, lesion detection (confirmed by pathology), or safety outcomes.

    8. The sample size for the training set

    • Sample Size (Training Set): Not applicable in the traditional sense of machine learning. The NeoGuide Endoscopy System is a hardware device with software to control its segments. There's no indication of a "training set" used for an AI algorithm in the context typically understood for diagnostic AI. The software "creates an anatomical map and interpret, monitor, and control the insertion tube segments," which implies control algorithms rather than a trained classification model.

    9. How the ground truth for the training set was established

    • Ground Truth (Training Set): Not applicable for the reasons stated above. If the software involved any form of learned control, the "training" would likely refer to engineering calibration and testing against design specifications, not a ground truth labeled for a diagnostic AI.