Found 2 results

510(k) Data Aggregation

    K Number
    K213614

    Validate with FDA (Live)

    Date Cleared
    2022-08-03

    (261 days)

    Product Code
    Regulation Number
    888.3040
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    N/A
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    Cannulated Screw and Double Compression Cannulated Screw are intended for the treatment of fractures, and arthrodesis of bones with the appropriate screw size.

    The Cannulated Compression Taper Screw (2.5-3.0 mm cannulated) are intended to be used as stand-alone bone screws for internal bone fixation for bone fractures, fusions, osteotomies and non-unions in the ankle, foot, hand, and wrist.

    The Cannulated Compression Taper Screw (3.5 mm and larger, cannulated) are intended to be used as stand-alone bone screws for internal bone fixation for bone fractures, fusions, ostectomies and non-unions in the ankle, foot, hand, wrist, clavicle, scapula, olecranon, humerus, radius, ulna, tibia, calcaneus, femur, and fibula.

    Device Description

    Cannulated Screws are implantable medical devices developed for application in osteosynthesis, with the purpose of reducing, compressing, aligning, stabilizing, and fixing different types of fractures, in small, medium, and large bones, of lower and upper limbs, and can be used in isolated form or associated with washers. This submission also includes the corresponding washers for Cannulated Screws.

    The screws have a hexagonal connection for a wrench and can be found in three different models: Cannulated Screw, Double Compression Cannulated Screw and Cannulated Compression Taper Screw. These devices are found in a variety of diameters to meet the range of anatomies of the patients, are presented in Titanium Alloy according to the standard ASTM F136, being provided in non-sterile condition.

    AI/ML Overview

    The provided text is a 510(k) Premarket Notification from the FDA regarding "Cannulated Screws." It details the device's indications for use, technological characteristics, and performance data. However, this document does not contain information about an AI/ML-driven medical device, a study involving human readers or expert ground truth, or an AI algorithm's performance.

    The "Performance Data" section discusses mechanical properties testing of the physical screws (torsional properties, driving torque, axial pullout strength, chemical and mechanical properties) against ASTM standards. It concludes that the device presents safety and efficacy in terms of its mechanical properties, but this pertains to the physical product, not a diagnostic or AI-assisted system.

    Therefore, I cannot provide the requested information regarding acceptance criteria and study details for an AI-driven device, as the provided document does not pertain to such a device.

    Ask a Question

    Ask a specific question about this device

    K Number
    K181843

    Validate with FDA (Live)

    Date Cleared
    2019-03-04

    (236 days)

    Product Code
    Regulation Number
    888.3030
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    N/A
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The MLP Special Locking Bone Plate System is indicated for use in internal fixation for bone fractures, fusions, osteotomies, pseudoarthroses, and non-unions of the humerus, radius, ulna, tibia, scapula, clavicle, fibula, tarsal, metatarsal and metatarsophalangeal in pediatrics and adult populations.

    Device Description

    The MLP Special Locking Bone Plate System consists of Bone Plates and locking screw components that are intended to be used in various bone fixation procedures. The MLP Special Locking Bone Plate System consists of bone plates and screws for fractures, fusions, and osteotomies. The bone plates are pre-bent to minimize bending which is done intraoperatively. Instruments are supplied with the implants to aid in the insertion of the plates and screws. All plates and screws are manufactured from titanium (Ti-6Al-4V) in conformance with ASTM F136. Plates and screws are provided non-sterile.

    AI/ML Overview

    This is a 510(k) premarket notification for the MLP Special Locking Bone Plate System. This type of submission rarely contains the kind of detailed performance data and study information you're asking for, as the primary goal is to demonstrate "substantial equivalence" to a predicate device.

    Based on the provided document, here's what can and cannot be answered regarding acceptance criteria and a study proving those criteria:

    1. Table of Acceptance Criteria and Reported Device Performance

    DescriptionAcceptance CriteriaReported Device Performance
    Material ConformityDevice materials should conform to ASTM F136 (titanium).All plates and screws are manufactured from titanium (Ti-6Al-4V) in conformance with ASTM F136.
    Static and Dynamic 4-Point Plate Bending Tests (ASTM F382-17, Annex 1, 2 and 3)Performance should demonstrate equivalence to predicate devices.The results of these evaluations indicate that the MLP Special Locking Plate System is equivalent to the predicate devices.
    Screw Pull-Out Tests (ASTM F543-17)Performance should demonstrate equivalence to predicate devices.The results of these evaluations indicate that the MLP Special Locking Plate System is equivalent to the predicate devices.
    Screw Torque Tests (ASTM F543-17)Performance should demonstrate equivalence to predicate devices.The results of these evaluations indicate that the MLP Special Locking Plate System is equivalent to the predicate devices.
    Screw Torsion Tests (ASTM F543-17)Performance should demonstrate equivalence to predicate devices.The results of these evaluations indicate that the MLP Special Locking Plate System is equivalent to the predicate devices.

    Important Note: The document states that the MLP Special Locking Plate System is equivalent to the predicate devices based on these tests, but it does not provide specific numerical acceptance criteria or detailed numerical results for any of these tests. For instance, it doesn't say "bending strength must be > X MPa" and then report "our device achieved Y MPa." It only states that the results "indicate equivalence."

    Regarding "the study that proves the device meets the acceptance criteria":

    The document describes non-clinical mechanical testing as the study that supports the substantial equivalence claim.

    2. Sample size used for the test set and the data provenance

    • Sample Size for Test Set: Not specified in the document. The tests performed are ASTM F382-17 and ASTM F543-17, but the number of devices or components tested is not mentioned.
    • Data Provenance: The document does not specify the country of origin of the data. It's an in-vitro non-clinical test conducted by the manufacturer or a contracted lab. It is a retrospective analysis in the sense that the tests were performed to support the 510(k) submission, not as part of an ongoing clinical trial.

    3. Number of experts used to establish the ground truth for the test set and the qualifications of those experts

    • This question is not applicable to this submission. The "ground truth" here is established by standardized mechanical testing protocols (ASTM). It's not a diagnostic device where expert interpretation of data generates a ground truth.

    4. Adjudication method (e.g. 2+1, 3+1, none) for the test set

    • This question is not applicable to this submission. Mechanical tests don't involve adjudication in this manner.

    5. If a multi reader multi case (MRMC) comparative effectiveness study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance

    • No, an MRMC comparative effectiveness study was not done. This is a bone plate system, not an AI-powered diagnostic device.

    6. If a standalone (i.e. algorithm only without human-in-the loop performance) was done

    • No, a standalone (algorithm only) performance study was not done. This is a mechanical device, not an algorithm.

    7. The type of ground truth used (expert consensus, pathology, outcomes data, etc.)

    • The "ground truth" for the non-clinical tests is the specified performance requirements and methods defined by the ASTM standards (ASTM F382-17 and ASTM F543-17). These standards define how the mechanical properties should be measured and likely include performance benchmarks (though the specific benchmarks are not reported in this document). The comparative aspect is against the performance of the predicate device(s).

    8. The sample size for the training set

    • This question is not applicable to this submission. There is no "training set" as this is not an AI/machine learning device. The design and validation of the device rely on engineering principles, material science, and mechanical testing.

    9. How the ground truth for the training set was established

    • This question is not applicable as there is no training set for this type of device.