Found 2 results

510(k) Data Aggregation

    K Number
    K140862

    Validate with FDA (Live)

    Date Cleared
    2014-08-27

    (146 days)

    Product Code
    Regulation Number
    884.2720
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The Monica Novii Pod is an intrapartum maternal-fetal monitor that non-invasively measures and displays fetal heart rate (FHR), uterine activity (UA) and maternal heart rate (MHR). The Novii Pod acquires and displays the FHR tracing from abdominal surface electrodes that pick up the fetal ECG (fECG) signal. Using the same surface electrodes, the Pod also acquires and displays the UA tracing from the uterine electromyography (EMG) signal and the MHR tracing from the maternal ECG signal (mECG). The Pod is indicated for use on women who are at >36 completed weeks, in labor, with singleton pregnancies, using surface electrodes on the maternal abdomen.

    The Novii Patch is an accessory to the Novii Pod that connects directly to the Novii Pod and contains the surface electrodes that attach to the abdomen.

    The Novii Interface is an accessory to the Novii Pod which provides a means of interfacing the wireless output of the Novii Pod to the transducer inputs of a CTG Fetal monitor. The Novii Interface enables signals collected by the Novii Pod to be printed and displayed on a CTG Fetal Monitor and sent on to a central network, if connected.

    The Novii Pod maternal-fetal monitor and its accessories are intended for use by healthcare professionals in a clinical setting

    Device Description

    The Monica Novii Pod Fetal-Maternal Monitor is designed as an ambulatory device for the monitoring of a pregnant mother. The monitor enables the abdominal electrophysiological signal to be picked up from three different positions on the maternal abdomen using the 5 electrodes on the Monica Novii Patch. The monitor filters the abdominal signals, converts the abdominal electrophysiological data into a digital format and then processes it in real time to extract the fetal heart rate, maternal heart rate and uterine activity. The result of the processing is transmitted via the Bluetooth connection to the Monica Novii CTG Interface device that is a Monica Approved accessory to the Monica Novii Pod.

    AI/ML Overview

    Here's a breakdown of the acceptance criteria and the studies that prove the Monica Novii Wireless Patch System meets them, based on the provided text:

    1. Table of Acceptance Criteria and Reported Device Performance

    The document provides acceptance criteria for non-clinical tests (Data Transfer Validation and Data Extraction Validation).

    Acceptance Criteria CategorySpecific MetricAcceptance CriteriaReported Device Performance
    Non-Clinical Testing
    Data Transfer ValidationBias difference for Fetal Heart Rate (FHR)Less than 1 BPMDemonstrated compliance (implies bias difference was < 1 BPM). The system achieves "reliability and accuracy of the data transfer... by demonstrating it meets pre-set thresholds i.e. a bias difference less of than 1 BPM for fetal heart rate and a maximum loss of transmitted to recorded data of 2%".
    Maximum loss of transmitted to recorded data2%Demonstrated compliance (implies loss was < 2%). Same as above.
    Data Extraction ValidationEquivalence with predicate for FHR, MHR, UA data (via statistical analysis)Demonstrated by statistical analysis including Positive Percent Agreement (PPA), Percentage Equivalence, and Sensitivity. Implicitly, these metrics met predefined thresholds for equivalence, though specific numerical thresholds are not provided in the summary.The results of the extracted data from the Novii Pod were compared to the output of the predicate Monica AN24 device, and "demonstrate equivalence by statistical analysis including; Positive Percent Agreement (PPA), Percentage Equivalence and Sensitivity." This implies the device met the criteria for equivalence.
    Clinical TestingEquivalence in clinical performance of FHR, MHR, UA with predicateSubstantial equivalence to the Ambu electrodes attached to the Monica AN24 predicate device.The results "demonstrated that the Monica Novii Patch is substantially equivalent to the Ambu electrodes attached to the Monica AN24 predicate device." (Specific quantitative metrics or detailed statistical results from the clinical study are not provided in this summary, but the conclusion states equivalence was demonstrated).

    2. Sample Sizes Used for the Test Set and Data Provenance

    • Clinical Study (Test Set):
      • Sample Size: 31 patients. The study was conducted in two stages:
        • 24 subjects recruited into three BMI groups.
        • 7 subjects where the Novii Patch was deliberately misplaced.
      • Data Provenance: The document does not explicitly state the country of origin for the clinical study data but implies it was collected in a clinical environment. Given Monica Healthcare is based in the UK, it's probable the study took place there. The study was prospective in nature, comparing the Novii Patch directly against a predicate device in a clinical setting.
    • Non-Clinical Data Extraction Validation (Test Set):
      • Sample Size: Ten (10) simulated data files.
      • Data Provenance: The simulated data files were "based on data collected from the maternal abdomen in previous fetal ECG trials" of the predicate Monica AN24 device (K101801). This is retrospective in terms of the original data used to create the simulations, but the testing itself was performed using these pre-existing simulated data sets.

    3. Number of Experts Used to Establish the Ground Truth for the Test Set and Their Qualifications

    • Clinical Study: The document does not specify the number of experts or their qualifications for establishing ground truth in the clinical study. It mentions the study monitored "clinical performance" implicitly against the predicate device's readings, suggesting the predicate device served as the reference rather than independent expert adjudication of the Novii's output alone.
    • Non-Clinical Studies: Ground truth for the non-clinical tests (Data Transfer and Data Extraction) was established by comparing the device's output against known input signals or the predicate device's output. No human experts were involved in establishing ground truth for these simulated tests.

    4. Adjudication Method for the Test Set

    • Clinical Study: The document does not describe a formal adjudication method by experts for the clinical study beyond comparing the Novii Patch's performance directly to that of the predicate device (Monica AN24 with Ambu electrodes).
    • Non-Clinical Studies: Adjudication was purely technical/automated, comparing device output to known inputs or predicate device output.

    5. Multi-Reader Multi-Case (MRMC) Comparative Effectiveness Study

    • No, an MRMC comparative effectiveness study was not explicitly mentioned or implied. The studies described focus on the device's performance characteristics and its equivalence to a predicate device, rather than how human readers' diagnostic accuracy or efficiency might improve with or without AI assistance. The Monica Novii Wireless Patch System appears to be a monitoring device that outputs raw data (FHR, MHR, UA tracings) rather than an AI-driven interpretive tool requiring human reader studies.

    6. Standalone (Algorithm Only) Performance Study

    • Yes, standalone performance was assessed in the non-clinical "Data Extraction Validation." In this test, the Novii Pod's ability to extract FHR, MHR, and UA data from simulated electrophysiological signals was directly compared to the predicate device's output using the same inputs. This assesses the algorithm's performance in isolation from the clinical environment where a human might interpret the data.

    7. Type of Ground Truth Used

    • Clinical Study: The ground truth was effectively the output of the predicate device (Monica AN24 with Ambu electrodes), as the study aimed to demonstrate substantial equivalence to this legally marketed device. This is a form of comparative ground truth against a recognized standard.
    • Non-Clinical Data Transfer Validation: Ground truth was the locally stored extracted data on the Novii Pod's Micro-SD card, compared against the transmitted data. This is a form of internal consistency ground truth.
    • Non-Clinical Data Extraction Validation: Ground truth was the output of the predicate Monica AN24 device when fed the same simulated inputs. This is also a form of comparative ground truth against a known standard.

    8. Sample Size for the Training Set

    • The document does not provide any explicit details about a training set size. The Monica Novii Wireless Patch System's detection technology is explicitly stated to be "identical to the Monica AN24 predicate device in that it use the same electronic components, the same signal processing software." This suggests it reuses the established algorithms from the predicate device, rather than relying on a newly trained (e.g., machine learning) algorithm that would require a distinct training set. The simulated data used in testing was based on "previous fetal ECG trials" of the predicate, which could be considered data from which the original algorithms were developed, but not a "training set" in the context of a new algorithm.

    9. How the Ground Truth for the Training Set Was Established

    • As there's no explicit mention of a new "training set" for a novel algorithm, the document doesn't detail how ground truth for a training set was established. The algorithms are inherited from the predicate device. The simulated data used for non-clinical testing was "based upon data collected in a trial of the predicate Monica AN24 device (K101801)" and "data collected from the maternal abdomen in previous fetal ECG trials" – these historical data sets would have had their own ground truth established via methods relevant to those original trials, likely involving expert review or known physiological parameters.
    Ask a Question

    Ask a specific question about this device

    K Number
    K112390

    Validate with FDA (Live)

    Device Name
    MONICA AN24
    Date Cleared
    2012-07-13

    (330 days)

    Product Code
    Regulation Number
    884.2720
    Age Range
    All
    Reference & Predicate Devices
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The Monica AN24 is an intrapartum maternal-fetal monitor that non-invasively measures and displays fetal heart rate (FHR), maternal heart rate (MHR) and uterine activity (UA). The AN24 acquires and displays the FHR & MHR tracing from abdominal surface electrodes that pick up the fetal ECG (fECG) and maternal ECG (mECG) signal. Using the same surface electrodes, the AN24 also acquires and displays the UA tracing from the uterine electromyography (EMG) signal. The AN24 is indicated for use on women who are at term (>36 completed weeks), in labor, with singleton pregnancies, using surface electrodes on the maternal abdomen.

    The AN24 maternal-fetal monitor is intended for use by healthcare professionals in a clinical setting.

    Device Description

    The Monica AN24™ is a small, battery-powered device for L&D surveillance of fetal well-being. The AN24™ is designed to passively monitor Fetal Heart Rate (FHR)), maternal heart rate (MHR) and Uterine Activity (UA) during pregnancy and can be used at any time from > 36 completed weeks gestation in laboring patients. The AN24™ is suitable for singleton pregnancies only.

    The Monica AN24 is a small, battery powered electrophysiological monitor (specifically fetal ECG, maternal ECG and uterine EMG). The electrical signals are passively monitored on three channels using five electrodes placed on the pregnant abdomen in specific locations. From these electrical signals the Fetal Heart Rate (FHR), maternal heart rate (MHR) and Uterine Activity (UA) are continuously extracted and displayed in the same standard format as the predicate device.

    AI/ML Overview

    Here's an analysis of the Monica AN24 device's acceptance criteria and study, based on the provided 510(k) summary:

    Monica AN24 Device Acceptance Criteria and Study Analysis

    The Monica AN24 is an intrapartum maternal-fetal monitor. This 510(k) summary focuses on demonstrating the substantial equivalence of the Monica AN24's Maternal Heart Rate (MHR) monitoring capability to a predicate SPO2 pulse oximeter (Philips M1191A). The FHR and UA monitoring capabilities had previously been cleared (K101801).


    1. Table of Acceptance Criteria and Reported Device Performance

    The study aimed to demonstrate non-inferiority of the Monica AN24's MHR monitoring compared to the predicate SPO2 pulse oximeter.

    Acceptance Criterion (Null Hypothesis of Inferiority, Alternative Hypothesis of Non-Inferiority)Reported Device Performance (Monica AN24 vs. Predicate SPO2)Outcome
    Reliability: Success Rate Ratio (Lower limit of CI > 0.8)Mean SR Ratio (AN24/SPO2): 1.16 CI: 1.08 - 1.21Met
    Accuracy: RMS Error (Upper limit of 95% CI for RMS error < 7 BPM)Combined RMS error (AN24 vs. SPO2): 4.49 BPM CI: 3.46 - 5.52 BPM Upper limit of 95% CI: 5.381 BPM (from conclusion)Met
    Correlation between AN24 and SPO2 MHR tracesMean: 0.90 CI: 0.87 - 0.93N/A (Secondary)
    95% Limits of Agreement-11.47 bpm to +11.62 bpmN/A (Descriptive)

    2. Sample Size Used for the Test Set and Data Provenance

    • Sample Size (for MHR study): 33 women (from the initial 60 enrolled women). This specific study focuses on MHR data.
    • Data Provenance: The study was conducted at two clinical sites: QHC, New York, and Temple University, Philadelphia, in the USA. The study was prospective.

    3. Number of Experts Used to Establish the Ground Truth for the Test Set and Qualifications

    The ground truth for the MHR study was established by a predicate SPO2 pulse oximeter (Philips M1191A) connected to a series 50 fetal monitor. The study does not mention the use of human experts to establish ground truth for MHR. Instead, it relies on the established accuracy and reliability of the predicate medical device.


    4. Adjudication Method for the Test Set

    Since the ground truth for MHR was established by a predicate medical device (SPO2 pulse oximeter) and not human experts, there was no adjudication method described or necessary in the traditional sense (e.g., 2+1, 3+1). The AN24's MHR readings were directly compared to the SPO2 readings.


    5. If a Multi-Reader Multi-Case (MRMC) Comparative Effectiveness Study was Done

    No, a multi-reader multi-case (MRMC) comparative effectiveness study was not conducted for the MHR monitoring capability. The study evaluates the performance of the AN24 device itself against a predicate device, not the improvement of human readers with AI assistance.


    6. If a Standalone (Algorithm Only Without Human-in-the-Loop Performance) Was Done

    Yes, a standalone performance evaluation was conducted. The study directly compares the MHR outputs of the Monica AN24 device (algorithm only, as it's an automated measurement) against the outputs of the predicate SPO2 pulse oximeter. There is no human intervention in the MHR measurement process for either device in this comparative study.


    7. The Type of Ground Truth Used

    The ground truth for the MHR was the measurement from a predicate medical device: a SPO2 pulse oximeter (Philips M1191A) known to produce an MHR trace. Additionally, maternal heart rate was monitored by a pulse oximeter as part of the overall study design.


    8. The Sample Size for the Training Set

    The document does not specify a separate training set or its sample size. This type of submission (510(k) for a device with established underlying technology for FHR/UA and comparing a new MHR method) usually focuses on validation rather than demonstrating the development of a novel algorithm from scratch. It's possible the MHR algorithm in the AN24 was developed using internal data not disclosed in this summary, or it relies on well-established ECG signal processing techniques that don't require training in the machine learning sense. The clinical study described here is for validation/testing purposes.


    9. How the Ground Truth for the Training Set Was Established

    As no separate training set is explicitly mentioned or detailed, the method for establishing its ground truth is also not provided in this summary.