510(k) Data Aggregation

    K Number
    K201549

    Validate with FDA (Live)

    Date Cleared
    2020-08-26

    (78 days)

    Product Code
    Regulation Number
    878.4040
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The Motex Anti-Fog Surgical Face Mask is intended to be worn to protect both the patient and healthcare personnel from transfer of microorganisms, body fluids, and particulate material. These face masks are intended for use in infection control practices to reduce potential exposure to blood and body fluids. The face mask is single use, disposable device, provided non-sterile.

    Device Description

    The Motex Anti-Fog Surgical Face Mask, type: Tie-on, Ear-loop, is flat pleated 3-ply device, which consists of four layers, i.e., Inner layer (Bicomponent thermal-bonded nonwoven, Polypropylene / Polyethylene, PP/PE), Filter layer (Polypropylene Melt-blown), Outer layer (Polypropylene Spunbond, blue/ green/ white/ pink color) and Anti-Fog films (EP coated Polyethylene). Each mask contains tie-on strips or elastic ear loops and of steel wire coated with Polyethylene resin to secure the mask fit over the user's mouth and nose. The dimensions of each mask are length 165±5 mm and width 95±2 mm.

    AI/ML Overview

    The provided text describes the acceptance criteria and performance data for the Motex Anti-Fog Surgical Face Mask.

    1. A table of acceptance criteria and the reported device performance

    Test item (Performance Level 3)Acceptance CriteriaReported Device PerformanceResult
    Bacterial filtration efficiency≥ 98%≥99%Pass
    Differential pressure (Delta-P)< 5 mm H2O/cm²2.6 mm H2O/cm²Pass
    Sub-micron particulate filtration efficiency at 0.1 µm of Polystyrene Latex Spheres≥ 98%99.75%Pass
    Resistance to penetration by synthetic blood, minimum pressure in mm Hg for pass resultFluid resistant claimed at 80, 120, 160 mm HgFluid Resistant claimed at 160 mm HgPass
    Flame spreadClass 1Class 1Pass
    In vitro Cytotoxicity TestPass ISO 10993-5:2009Pass ISO 10993-5:2009Pass
    Skin Sensitization TestPass ISO 10993-10:2010Pass ISO 10993-10:2010Pass
    Skin Irritation TestPass ISO 10993-10:2010Pass ISO 10993-10:2010Pass

    2. Sample size used for the test set and the data provenance

    The document does not specify the exact sample sizes (number of masks tested) for each non-clinical test. The tests are described as "Performance Testing summary" and "Biocompatibility Testing." Given the nature of these tests for medical devices, they were likely conducted in a controlled laboratory setting. The manufacturer is Modern Healthcare Corp., located in Hsin-Chu City, Taiwan. The provenance of the data is therefore Taiwan, and the tests were prospective in nature, performed to demonstrate compliance.

    3. Number of experts used to establish the ground truth for the test set and the qualifications of those experts

    This information is not applicable as the evaluation is based on non-clinical, objective performance tests (e.g., filtration efficiency, pressure differential, flame spread) and biocompatibility tests, not subjective expert assessment of images or medical cases.

    4. Adjudication method for the test set

    This information is not applicable as the evaluation is based on objective performance tests with predefined pass/fail criteria, not subjective human assessment requiring adjudication.

    5. If a multi reader multi case (MRMC) comparative effectiveness study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance

    A multi-reader multi-case (MRMC) comparative effectiveness study was not done. This type of study is relevant for AI-powered diagnostic tools or image analysis, which is not the case for a surgical face mask.

    6. If a standalone (i.e. algorithm only without human-in-the-loop performance) was done

    A standalone performance test for an algorithm was not done. This medical device is a physical product (a surgical face mask), not a software algorithm.

    7. The type of ground truth used

    The ground truth used for verifying the device's performance relies on objective measurements and standardized test methods. These include:

    • ASTM F2101-14 for Bacterial filtration efficiency.
    • MIL-M-36954C, Section 4.4.1.2 for Differential pressure.
    • ASTM F2299-03 for Sub-micron particulate filtration efficiency.
    • ASTM F1862-17 or ISO 22609:14 for Resistance to penetration by synthetic blood.
    • 16 CFR Part 1610 for Flame spread.
    • ISO 10993-5:2009 for In vitro Cytotoxicity Test.
    • ISO 10993-10:2010 for Skin Sensitization Tests and Skin Irritation Tests.

    8. The sample size for the training set

    This information is not applicable. The device is a physical medical device (surgical face mask), not a machine learning or AI algorithm that requires a "training set."

    9. How the ground truth for the training set was established

    This information is not applicable as there is no training set for this type of device.

    Ask a Question

    Ask a specific question about this device

    K Number
    K191898

    Validate with FDA (Live)

    Date Cleared
    2019-12-18

    (155 days)

    Product Code
    Regulation Number
    878.4460
    Age Range
    All
    Reference & Predicate Devices
    N/A
    Predicate For
    N/A
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    Sterile Latex Powder-Free Surgical Gloves are sterile disposable devices made of natural rubber latex (that may bear a trace amount of glove powder) and are intended to be worn on the hands, usually in surgical settings, to provide a barrier against potentially infectious materials and other contaminants.

    Device Description

    Sterile Latex Powder-Free Surgical Gloves are sterile disposable devices made of natural rubber latex (that may bear a trace amount of glove powder) and are intended to be worn on the hands, usually in surgical settings, to provide a barrier against potentially infectious materials and other contaminants.

    AI/ML Overview

    I am sorry to inform you that the provided text is a 510(k) clearance letter from the FDA for Sterile Latex Powder-Free Surgical Gloves.

    This document does not contain information about a medical device that utilizes AI or algorithms, nor does it discuss acceptance criteria, study data, or ground truth establishment relevant to AI/ML device performance.

    Therefore, I cannot fulfill your request to describe the acceptance criteria and the study that proves the device meets those criteria, as the document does not contain this type of information. It is a regulatory document for a physical medical device (gloves).

    Ask a Question

    Ask a specific question about this device

    K Number
    K063043

    Validate with FDA (Live)

    Date Cleared
    2007-03-21

    (169 days)

    Product Code
    Regulation Number
    878.4040
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The Surgical Face Mask of different colors (Green, White, Blue and Pink) is a device intended to be worn by operating room personnel during surgical procedures to protect both the surgical patient and the operation room personnel from transfer of microorganisms, body fluid and particulate material.

    Device Description

    Modern Healthcare Corp. Surgical Face Mask, type: Tie-on and Ear-loop, are flat pleated 3-ply (at least) masks with an inner and outer layer (spunbonded polypropylene) that sandwich a melt blown polypropylene filter material, also with elastic loops and / or strip. The nosepiece for all Modern Healthcare Corp. Surgical Face Mask is malleable aluminum wire. All the materials used in the construction of the Modern Healthcare Corp. Surgical Face Mask are being used in currently marked devices.

    AI/ML Overview

    The provided text is a 510(k) summary for a surgical face mask. It indicates that no clinical tests were performed to establish acceptance criteria or to prove that the device meets those criteria. Instead, the device's substantial equivalence to a predicate device (K060776) was demonstrated through bench testing.

    Therefore, most of the requested information regarding acceptance criteria and study details cannot be extracted from this document.

    Here's a breakdown of what can be answered based on the provided text:

    1. A table of acceptance criteria and the reported device performance

    Not applicable. The document states "Discussion of Clinical Tests Performed: Not Applicable". Performance targets and results from clinical studies are not provided. The substantial equivalence is based on meeting the same technological characteristics as the predicate device, which implies compliance with relevant standards through bench testing, not clinical performance criteria.

    2. Sample sized used for the test set and the data provenance (e.g. country of origin of the data, retrospective or prospective)

    Not applicable. No clinical test set or data provenance is mentioned. The submission relies on "bench testing" which is typically laboratory-based and doesn't involve human subjects for performance evaluation in the way a clinical study would.

    3. Number of experts used to establish the ground truth for the test set and the qualifications of those experts (e.g. radiologist with 10 years of experience)

    Not applicable. No clinical test set requiring expert ground truth establishment is mentioned.

    4. Adjudication method (e.g. 2+1, 3+1, none) for the test set

    Not applicable. No clinical test set requiring adjudication is mentioned.

    5. If a multi reader multi case (MRMC) comparative effectiveness study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance

    Not applicable. This is a surgical face mask, not an AI-assisted diagnostic device. No MRMC study or AI component is involved.

    6. If a standalone (i.e. algorithm only without human-in-the-loop performance) was done

    Not applicable. This is a surgical face mask, not an algorithm.

    7. The type of ground truth used (expert consensus, pathology, outcomes data, etc)

    Not applicable. No clinical ground truth is mentioned. The evaluation is based on bench testing of the product's physical and filtration properties, comparing them to established standards and the predicate device.

    8. The sample size for the training set

    Not applicable. No training set is mentioned as this is not an AI/machine learning device.

    9. How the ground truth for the training set was established

    Not applicable. No training set or ground truth for a training set is mentioned.