    Intended Use

    These cannulae are intended for collection of venous blood from the right side of the heart via the superior and inferior vena cava during cardiopulmonary bypass surgery.

    Device Description

    The Medtronic DLP Malleable Single Stage Venous Cannulae represent modified versions of existing Medtronic Single Stage Venous Cannulae. The proposed change involves the incorporation of a malleable wire/tube assembly embedded within the wall of the cannula. This malleable wire/tube assembly allows the cannula body to be shaped into a surgeon preferred position.

    AI/ML Overview

    The provided document, KO22272 for the Medtronic DLP Malleable Single Stage Venous Cannula, is a 510(k) summary for a medical device. This type of submission focuses on demonstrating substantial equivalence to a legally marketed predicate device rather than establishing completely new performance criteria. Therefore, the document does not contain detailed acceptance criteria in the form of specific performance metrics or a study that rigorously "proves" the device meets them in the same way a de novo or PMA submission might.

    Instead, the acceptance criteria are implicitly met by demonstrating that the new device is as safe and effective as the predicate device, which is already on the market. The study described focuses on non-clinical tests to support this substantial equivalence.

    Here's an analysis based on the provided text, addressing the requested points where information is available:

    1. Table of Acceptance Criteria and Reported Device Performance:

    Acceptance Criteria (Implicit)Reported Device Performance
    Material Biocompatibility (as per ISO 10993-1 for externally communicating devices in contact with circulating blood for <24 hours)Non-clinical tests conducted, results support assertion of safety and effectiveness as predicate device.
    Substantial Equivalence to Predicate Device (Medtronic DLP Single Stage Venous Cannulae, K845045) in terms of safety and effectiveness.The addition of a malleable wire/tube assembly does not change the fundamental scientific technology or intended use.

    Explanation of "Acceptance Criteria" in this context: For a 510(k) submission, the primary "acceptance criterion" is demonstrating substantial equivalence to a predicate device. This means showing that the new device is as safe and effective as a device already cleared by the FDA. The specific performance metrics are often derived from the predicate device's established safety and effectiveness. Here, the key performance aspect is the biocompatibility of the materials used in the modified device.

    2. Sample size used for the test set and the data provenance:

    • Sample Size: The document does not specify a numerical sample size for the non-clinical tests. "Material biocompatibility was conducted in accordance with the ISO 10993-1 standard," which typically involves various in vitro and in vivo tests, but the number of samples or specimens used is not detailed.
    • Data Provenance: The data is from "non-clinical tests" conducted by Medtronic. The country of origin is not explicitly stated, but Medtronic is a US-based company, and the submission is to the FDA. The tests are "non-clinical," meaning they are laboratory or bench tests, not involving human subjects.

    3. Number of experts used to establish the ground truth for the test set and the qualifications of those experts:

    • This information is not provided in the document. For non-clinical, biocompatibility testing, "ground truth" is established through standardized laboratory procedures and scientific protocols rather than expert consensus on individual cases.

    4. Adjudication method for the test set:

    • This concept is not applicable to the type of non-clinical, biocompatibility testing described. Adjudication methods (like 2+1, 3+1) are typically used in clinical studies when multiple human readers/reviewers assess images or clinical outcomes.

    5. If a multi-reader multi-case (MRMC) comparative effectiveness study was done, if so, what was the effect size of how much human readers improve with AI vs without AI assistance:

    • No, a multi-reader multi-case (MRMC) comparative effectiveness study was not done. This device is a cardiovascular cannula, a physical medical device, not an AI or imaging diagnostic tool. Therefore, the concept of "human readers improving with AI assistance" is not relevant here.

    6. If a standalone (i.e., algorithm only without human-in-the-loop performance) was done:

    • No, a standalone (algorithm only) performance study was not done. This is a physical medical device, not an algorithm.

    7. The type of ground truth used:

    • For the non-clinical biocompatibility tests, the "ground truth" is derived from the results of the specific standardized tests themselves (e.g., cytotoxicity assays, sensitization tests, irritation tests, hemocompatibility tests as defined by ISO 10993-1). The pass/fail criteria for these tests, based on established biological responses, serve as the ground truth.

    8. The sample size for the training set:

    • This device is not an AI/ML algorithm, so there is no "training set" in that sense. The concept of a training set is not applicable.

    9. How the ground truth for the training set was established:

    • As there is no training set for an AI/ML algorithm, this question is not applicable.
    Ask a Question

    Ask a specific question about this device

    K Number
    K013013

    Validate with FDA (Live)

    Date Cleared
    2001-12-04

    (88 days)

    Product Code
    Regulation Number
    870.4210
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    These cannulae are intended for the perfusion of the ascending aorta during short-term (6 hours or less) cardiopulmonary bypass.

    Device Description

    The Medtronic DLP Arterial Cannulae with 3D Tip represent modified versions of existing Medtronic DLP Arterial Cannulae. The proposed change involves the incorporation of a baffled tip design into the 22 Fr. cannula. This baffled tip imparts a more diffuse pattern of blood flow exiting from the cannula tip than exists with the existing open tip cannula design.

    AI/ML Overview

    The provided document is a 510(k) Summary for a medical device (Medtronic DLP Arterial Cannulae with 3D Tip - 22 Fr.) and describes non-clinical performance data rather than a study with acceptance criteria and device performance in the context of human data or AI algorithms. As such, many of the requested categories are not applicable.

    Here's an analysis based on the available information:

    1. Table of Acceptance Criteria and Reported Device Performance

    Acceptance CriteriaReported Device Performance
    Biocompatibility: In accordance with ISO 10993-1 for externally communicating devices in contact with circulating blood for <24 hours.Material biocompatibility testing was conducted in accordance with ISO 10993-1.
    Dynamic Hemolytic Properties: Rates of hemolysis comparable to competitive comparator models.Rates of hemolysis observed for the modified device were comparable to those measured for comparator cannulae.

    2. Sample size used for the test set and the data provenance

    • Sample Size: Not specified for biocompatibility testing; for hemolytic properties, "Short circuits containing 1000 ml of freshly collected, heparinized bovine blood" were constructed. The number of such circuits or repetitions is not specified.
    • Data Provenance: The hemolytic properties test used "freshly collected, heparinized bovine blood." This is an in vitro test, not human data. The country of origin for the data is not specified, but the test was likely conducted by Medtronic or a contracted lab.
    • Retrospective/Prospective: Prospective (experimental).

    3. Number of experts used to establish the ground truth for the test set and the qualifications of those experts

    Not applicable. This was a non-clinical in vitro and material testing study, not requiring expert ground truth establishment in the traditional sense of clinical studies or AI algorithm evaluation.

    4. Adjudication method for the test set

    Not applicable. This was a non-clinical in vitro and material testing study.

    5. If a multi reader multi case (MRMC) comparative effectiveness study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance

    Not applicable. This document describes a medical device, not an AI or imaging diagnostic tool, and therefore no MRMC study, human reader improvement, or AI assistance is relevant.

    6. If a standalone (i.e. algorithm only without human-in-the-loop performance) was done

    Not applicable. This document describes a physical medical device, not an algorithm.

    7. The type of ground truth used

    • Biocompatibility: Compliance with ISO 10993-1 standard.
    • Dynamic Hemolytic Properties: Measurement of hemolysis rates in comparison to established performance of predicate/comparator devices. This is a scientific measurement rather than an expert consensus or pathology ground truth.

    8. The sample size for the training set

    Not applicable. This is a physical medical device, not an AI model, so there is no training set.

    9. How the ground truth for the training set was established

    Not applicable. There is no training set for a physical medical device.

    Ask a Question

    Ask a specific question about this device

    K Number
    K012143

    Validate with FDA (Live)

    Date Cleared
    2001-10-24

    (106 days)

    Product Code
    Regulation Number
    870.1280
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    N/A
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The 24 Fr. Left Heart Vent Catheter with Pressure Monitoring Line is intended for use in venting the left heart during cardiopulmonary bypass surgery.

    Device Description

    The 24 Fr. Left Heart Vent Catheter with Pressure Monitoring Line is designed for use in venting the left heart during cardiopulmonary bypass surgery.

    The 24 Fr. Left Heart Vent Catheter with Pressure Monitoring Line is equipped with a pressure monitoring line, which allows measurement of left ventricular pressure.

    AI/ML Overview

    This submission package does not contain the level of detail required to complete the requested table and provide specific information on acceptance criteria and study design elements like sample sizes, ground truth establishment, or expert qualifications. The provided document is a 510(k) summary for a medical device (24 Fr. Left Heart Vent Catheter w/ Pressure Monitoring Line) seeking substantial equivalence to predicate devices.

    Here's why and what can be pieced together:

    Key Takeaways from the Document:

    • Substantial Equivalence: The primary goal of this submission is to demonstrate that the new device is substantially equivalent to already legally marketed predicate devices. This means it has the same intended use, similar technological characteristics, and does not raise new questions of safety or effectiveness.
    • No Clinical Trials: 510(k) submissions, especially for devices seeking substantial equivalence based on minor modifications, often rely heavily on bench testing and comparison to predicates rather than extensive clinical studies with human participants. This is evident as no mention of human subject data, clinical trials, or expert reader studies (MRMC, standalone AI performance) is present.
    • Bench Testing: The document explicitly states: "The biocompatibility rationale and in vitro bench testing demonstrated that when compared to the predicate devices, the 24 Fr. Left Heart Vent Catheter with Pressure Monitoring Line does not significantly affect safety and effectiveness and are substantially equivalent to other commercially distributed devices. The in vitro bench testing included analysis of: kink testing, clamp testing, flexibility testing, burst, leak testing, pull testing and pressure monitoring capability."

    Therefore, many sections of your request cannot be directly answered from this document.

    Here's an attempt to populate the table and answer the questions based on the available information, noting where information is absent:


    1. Table of acceptance criteria and the reported device performance

    Acceptance Criteria CategorySpecific Acceptance Criteria (Inferred)Reported Device Performance
    Material PropertiesBiocompatibility: Device materials (Polyvinyl Chloride - PVC) must be non-toxic and compatible with biological tissue, similar to predicate devices.Biocompatibility rationale demonstrated no significant effect on safety and effectiveness when compared to predicate devices.
    Mechanical IntegrityKink Resistance: The catheter must maintain patency and functionality when subjected to bending or kinking forces, similar to predicate devices. Clamp Resistance: The catheter must withstand clamping without damage or loss of functionality. Flexibility: The catheter must possess appropriate flexibility for its intended surgical use to facilitate insertion and positioning. Burst Strength: The catheter must withstand internal pressure without bursting. Leak Integrity: The catheter must not leak fluids at connections or along its length. Pull Strength: The catheter must withstand tensile forces during handling and use without separation or damage.In vitro bench testing (kink, clamp, flexibility, burst, leak, pull testing) demonstrated that the device does not significantly affect safety and effectiveness and is substantially equivalent to predicate devices.
    Functional PerformancePressure Monitoring Capability: The integrated pressure monitoring line must accurately and reliably measure left ventricular pressure within an acceptable range, equivalent to predicate devices with pressure monitoring features (e.g., Aortic Root Cannula with Integral Pressure Monitoring Line).In vitro bench testing included analysis of "pressure monitoring capability," demonstrating substantial equivalence. (Specific performance metrics like accuracy range are not provided in this summary).

    2. Sample sized used for the test set and the data provenance (e.g. country of origin of the data, retrospective or prospective)

    • Sample Size: Not specified for any of the bench tests.
    • Data Provenance: The tests are in-vitro bench tests, not involving human or animal subjects. The location of the testing is not specified, but it was conducted by Medtronic, Inc. in the USA. Given the nature of a 510(k) for device modifications, these would be considered retrospective in the sense that the new device's performance is compared against known characteristics or specifications of existing predicate devices and general standards.

    3. Number of experts used to establish the ground truth for the test set and the qualifications of those experts (e.g. radiologist with 10 years of experience)

    • This information is not applicable (N/A) as the study involved in-vitro bench testing, not expert interpretation or clinical assessment.

    4. Adjudication method (e.g. 2+1, 3+1, none) for the test set

    • This information is not applicable (N/A) as the study involved in-vitro bench testing, not subjective assessment requiring adjudication.

    5. If a multi reader multi case (MRMC) comparative effectiveness study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance

    • No MRMC study was done. This is a 510(k) for a physical medical device (catheter), not an AI-enabled diagnostic tool. Therefore, concerns about human reader improvement with AI are not applicable (N/A).

    6. If a standalone (i.e. algorithm only without human-in-the-loop performance) was done

    • No standalone algorithm performance study was done. This is a 510(k) for a physical medical device, not an AI algorithm. Therefore, concerns about standalone algorithm performance are not applicable (N/A).

    7. The type of ground truth used (expert consensus, pathology, outcomes data, etc.)

    • The "ground truth" for the bench tests would be the pre-defined engineering specifications, material standards, and performance characteristics of the predicate devices. For instance, the "ground truth" for burst pressure would be a certain pressure threshold the device must withstand, derived from safety standards and predicate device performance. It is based on engineering specifications and established material/device performance standards.

    8. The sample size for the training set

    • This is not applicable (N/A). This device is not an AI algorithm, and thus, there is no AI "training set."

    9. How the ground truth for the training set was established

    • This is not applicable (N/A) as there is no AI training set.
    Ask a Question

    Ask a specific question about this device

    K Number
    K010737

    Validate with FDA (Live)

    Date Cleared
    2001-04-04

    (23 days)

    Product Code
    Regulation Number
    870.4210
    Age Range
    N/A
    Reference & Predicate Devices
    N/A
    Predicate For
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use
    Device Description
    AI/ML Overview
    Ask a Question

    Ask a specific question about this device

    K Number
    K000776

    Validate with FDA (Live)

    Date Cleared
    2001-02-07

    (334 days)

    Product Code
    Regulation Number
    870.4210
    Age Range
    N/A
    Reference & Predicate Devices
    N/A
    Predicate For
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use
    Device Description
    AI/ML Overview
    Ask a Question

    Ask a specific question about this device

    K Number
    K994171

    Validate with FDA (Live)

    Date Cleared
    2000-04-27

    (139 days)

    Product Code
    Regulation Number
    870.4210
    Age Range
    All
    Reference & Predicate Devices
    N/A
    Predicate For
    N/A
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    These devices are intended for the perfusion of anticoagulated arterial blood to an ischemic area of the heart.
    These devices are intended for the perfusion of anticoagulated arterial blood from the aorta to coronary vessels to supply an ischemic area of the heart during beating heart CABG procedures.

    Device Description

    The Medtronic AortoCoronary Shunt includes an Aortic Root Cannula Assembly, a Y-Tubing Connector Assembly and a set of Arteriotomy Cannulae (2 mm, 3 mm and 4 mm sizes). The Arteriotomy Cannula Assemblies are also available separately for user convenience. The user assembles the components into the final product configuration immediately prior to use. The assembled device diverts oxygenated, arterial blood from the patient's aorta directly to one or two coronary arteries, thereby providing perfusion of an ischemic area of the heart during cardiac surgical procedures

    AI/ML Overview

    The Medtronic AortoCoronary Shunt and Arteriotomy Cannulae are medical devices intended for the perfusion of anticoagulated arterial blood to an ischemic area of the heart during cardiac surgical procedures. The provided 510(k) summary outlines the non-clinical performance data used to assert substantial equivalence to legally marketed predicate devices.

    1. Table of Acceptance Criteria and Reported Device Performance

    Test CategoryAcceptance CriteriaReported Device Performance
    BiocompatibilityNegative (non-toxic) results in a battery of tests per ISO 10993-1.- Cytotoxicity (MEM Elution Method): Negative results- Sensitization (Guinea Pig Maximization Method): Negative results- Intracutaneous Reactivity (in rabbits): Negative results- Acute Systemic Toxicity (in mice): Negative results- Genotoxicity (Ames Salmonella typhimurium / Escherichia coli Mutation Reversion Method): Negative results- Hemocompatibility (material-mediated Hemolysis and Thrombogenicity): Negative results
    Tensile and Hydrostatic Burst TestingAcceptable strength and integrity of all device segments.Yielded acceptable results on all segments of the fully assembled AortoCoronary Shunt.
    Resistance to Fluid FlowCapable of delivering blood to target coronary arteries at flow rates higher than normally observed.Demonstrated that the product is capable of delivering blood to target coronary arteries at flow rates that are higher than are normally observed in those coronary arteries. Evaluated for both Arteriotomy Cannulae alone and the fully assembled AortoCoronary Shunt.
    Resistance to Kinking and Damage due to ClampingAcceptable resistance to kinking and damage.Yielded acceptable results.

    2. Sample Size Used for the Test Set and Data Provenance

    The provided document describes non-clinical performance data, meaning these are laboratory or bench tests, not tests on human subjects. Therefore, the concept of a "test set" with human data is not applicable in this context.

    • Sample Size: Not explicitly stated for each test (e.g., number of devices tested for tensile strength). However, the document implies that a sufficient number of samples were tested to demonstrate acceptable performance for each criterion.
    • Data Provenance: The tests are explicitly described as "non-clinical" performance data, conducted in a laboratory setting. Country of origin of data is not specified but is implicitly associated with the submitter, Medtronic Cardiac Surgical Products, Grand Rapids, MI, USA. The data is prospective in the sense that the tests were conducted specifically to evaluate the new device.

    3. Number of Experts Used to Establish Ground Truth for the Test Set and Qualifications of Those Experts

    Not applicable. As this involves non-clinical bench testing, the concept of "ground truth" established by medical experts (e.g., radiologists) for a test set is not relevant. The "ground truth" here is the physical and biological characteristics measured by the laboratory tests against established scientific and regulatory standards (e.g., ISO 10993-1).

    4. Adjudication Method for the Test Set

    Not applicable. Adjudication methods like 2+1 or 3+1 are used for human reader studies or clinical trials to resolve discrepancies in expert opinions. For non-clinical bench testing, the results are typically quantitative measurements or qualitative observations directly compared against pre-defined acceptance criteria.

    5. If a Multi-Reader Multi-Case (MRMC) Comparative Effectiveness Study Was Done

    No, an MRMC comparative effectiveness study was not done. The document focuses on non-clinical performance data to demonstrate substantial equivalence to predicate devices, not on comparing the effectiveness of human readers with and without AI assistance.

    6. If a Standalone (i.e., algorithm only without human-in-the-loop performance) Was Done

    No, a standalone (algorithm only) performance study was not done. This submission is for a physical medical device (AortoCoronary Shunt and Arteriotomy Cannulae), not for an artificial intelligence/machine learning algorithm.

    7. The Type of Ground Truth Used

    The "ground truth" for these non-clinical tests is based on:

    • International Standards: Specifically, ISO 10993-1 for biocompatibility.
    • Engineering Principles and Benchmarks: For functional tests like tensile strength, burst pressure, fluid flow resistance, and kinking resistance, the ground truth is established by physical measurements and comparison against expected physiological performance (e.g., flow rates higher than normally observed in coronary arteries) and engineering specifications for device integrity.

    8. The Sample Size for the Training Set

    Not applicable. There is no mention of a "training set" as this is not an AI/ML device. The tests described are for a physical medical device.

    9. How the Ground Truth for the Training Set Was Established

    Not applicable, as there is no training set for an AI/ML algorithm.

    Ask a Question

    Ask a specific question about this device

    K Number
    K000274

    Validate with FDA (Live)

    Date Cleared
    2000-02-10

    (10 days)

    Product Code
    Regulation Number
    870.4210
    Age Range
    N/A
    Reference & Predicate Devices
    N/A
    Predicate For
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use
    Device Description
    AI/ML Overview
    Ask a Question

    Ask a specific question about this device

    Page 1 of 1