Found 4 results

510(k) Data Aggregation

    K Number
    K000693

    Validate with FDA (Live)

    Date Cleared
    2000-05-16

    (76 days)

    Product Code
    Regulation Number
    878.4810
    Age Range
    N/A
    Reference & Predicate Devices
    N/A
    Predicate For
    N/A
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use
    Device Description
    AI/ML Overview
    Ask a Question

    Ask a specific question about this device

    K Number
    K972368

    Validate with FDA (Live)

    Date Cleared
    1997-09-23

    (90 days)

    Product Code
    Regulation Number
    878.4810
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    N/A
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The Fotona Skinlight Plus Nd: YAG system is indicated for the photocoagulation of benign vascular and pigmented lesions.

    Device Description

    The Fotona Skinlight Plus system is based on the addition of a Nd: YAG accessory to a previously cleared Er: YAG system (K962902). Within the accessory sub-system, an optical cavity contains the Nd: YAG crystal, which is activated by means of the use of flashlamps. After the cavity,a red diode aiming beam is reflected onto a coaxial beam path using a beamsplitter assembly. The combined therapuetic and aiming beams are guided down an optical fiber delivery system to a focusing handpiece. The laser is used in noncontact mode. The System is capable of emitting up to 2.0 Watts of light at 532 nm, with a minimal pulsewidth envelope of 100ms. The laser is intended to be used for the photocoagulation of benign vascular and pigmented lesions. The Nd: YAG accessory sub-system is designed with 3 major sub-systems: a) An optical fiber delivery system terminated in spot-size specific handpiece. b) An electronic power supply and interface circuitry. c) An optical chamber containing laser rod and laser cavity optics. No accessories are available for use with the accessory Nd: Y AG sub-system.

    AI/ML Overview

    This document is a 510(k) premarket notification for the Fotona Skinlight Plus Nd:YAG Laser system. It aims to demonstrate substantial equivalence to a previously cleared device, the Laserscope Aura system (K951034), for the photocoagulation of benign vascular and pigmented lesions.

    The document does not contain a detailed study with acceptance criteria and reported device performance in the way that would typically be presented for an AI/Software as a Medical Device (SaMD). Instead, it relies on demonstrating substantial equivalence to a predicate device, which is a common pathway for medical device clearance.

    Therefore, many of the requested sections about explicit acceptance criteria, study details, sample sizes, expert ground truth, and comparative effectiveness (which are typically relevant for AI/SaMD) cannot be directly extracted from this submission.

    Here's a breakdown based on the provided text, addressing what can be inferred and what is not applicable or not provided:

    1. Table of Acceptance Criteria and Reported Device Performance

    This document does not define explicit performance acceptance criteria in terms of sensitivity, specificity, accuracy, or similar metrics, nor does it present device performance data against such criteria. The "acceptance criteria" here is implicitly demonstrating substantial equivalence to a predicate device based on similar intended use, technological characteristics (wavelength, power, pulsewidth), and safety/effectiveness profile.

    The summary states:

    • Intended Use: "The Fotona Skinlight Plus Nd: YAG system is intended for the photocoagulation of benign vascular and pigmented lesions." (Same as predicate)
    • Wavelength: 532nm (Same as predicate)
    • Maximum Average Power: 10 Watts (Same as predicate)
    • Pulsewidth: 0.1 - 1.0 seconds (envelope width), with continuous emission option (Similar to predicate)

    The document concludes: "It is therefore believed that there are no new questions of Safety or Effectiveness raised by the introduction of this device." This statement serves as the "reported device performance" in the context of a substantial equivalence claim – meaning its performance is considered equivalent to a device already deemed safe and effective.

    2. Sample Size Used for the Test Set and Data Provenance

    Not applicable. This submission does not describe a clinical study with a "test set" in the context of an AI/SaMD performance evaluation. Substantial equivalence claims often rely on engineering analysis, bench testing, and comparison of characteristics, rather than patient-level performance data against a ground truth.

    3. Number of Experts Used to Establish the Ground Truth for the Test Set and the Qualifications of Those Experts

    Not applicable. There is no "test set" and no ground truth established by experts for performance evaluation as would be done for an AI/SaMD.

    4. Adjudication Method for the Test Set

    Not applicable. No test set requiring expert adjudication is described.

    5. If a Multi Reader Multi Case (MRMC) Comparative Effectiveness Study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance

    Not applicable. This is a medical device (laser system), not an AI/SaMD for diagnostic interpretation. There is no mention of "human readers" or "AI assistance."

    6. If a Standalone (i.e. algorithm only without human-in-the-loop performance) was done

    Not applicable. This is a physical medical device (laser), not a standalone algorithm.

    7. The Type of Ground Truth Used

    Not applicable. No "ground truth" (e.g., pathology, outcomes data) as would be used in a diagnostic performance study is described or utilized in this substantial equivalence claim. The "ground truth" for supporting the claim is the established safety and effectiveness of the predicate device.

    8. The Sample Size for the Training Set

    Not applicable. This is not an AI/Machine Learning device that requires a "training set."

    9. How the Ground Truth for the Training Set Was Established

    Not applicable. (As above, no training set).

    Ask a Question

    Ask a specific question about this device

    K Number
    K970757

    Validate with FDA (Live)

    Device Name
    FOTONA SKINSCAN
    Date Cleared
    1997-05-09

    (67 days)

    Product Code
    Regulation Number
    878.4810
    Age Range
    All
    Reference & Predicate Devices
    N/A
    Predicate For
    N/A
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    Not Found

    Device Description

    The Fotona Skinscan system is a microprocessor controlled device which generates precisely defined patterns on skin tissue in an automated sequence to increase uniformity and ease of treatment when used in conjunction with a host Skinlight system. The Fotona Skinscan system is designed as an accessory for use with the Fotona Skinlight laser system. Skinscan is functionally integrated to the host laser system. When the scanner head is attached to the articulated arm and the scanner cable is connected, the host laser system recognizes the presence and activation of the accessory and permits activation of the scanner specific modes which are programmed into the host at time of installation of the scanner accessory. In these modes scanner settings can be selected from an easy-toread menu. When the operator reverts to use of the standard dermatological handpiece, these settings are not accessible. When the scanner is connected and a scanner sub-menu is selected the system automatically initiates for scanner operation. The Skinscan system is designed with 3 major sub-systems a) A scanner handpiece comprising smoke evacuation components and distance gauge components. b) A scanner head, containing scanning mirrors and imaging optics. c) An electronic control hox containing scanning mirror control and laser interface circuitry.

    AI/ML Overview

    The provided text describes a medical device called the Fotona Skinscan system, an accessory for the Fotona Skinlight laser system. However, the text does not contain any information about acceptance criteria, device performance studies, sample sizes, expert qualifications, or ground truth methodologies.

    Therefore, I cannot fulfill your request for a table of acceptance criteria, study details, or information about MRMC studies, standalone performance, or training set specifics based on the provided input.

    The text focuses solely on:

    • Description of the device: Its components, function as an accessory to the Skinlight laser, and how it integrates with the host system.
    • Claim of substantial equivalence: Comparing it to the Coherent CPG system and stating that it raises no new questions of safety or effectiveness.
    Ask a Question

    Ask a specific question about this device

    K Number
    K962902

    Validate with FDA (Live)

    Date Cleared
    1997-01-10

    (169 days)

    Product Code
    Regulation Number
    878.4810
    Age Range
    All
    Reference & Predicate Devices
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The laser is intended to be used for cutting, and coagulating soft tissue.

    Device Description

    The Fotona Skinlight system is based on Er: Y AG laser technology. Within the system, an optical cavity contains the Er: YAG crystal, which is activated by means of the use of flashlamps. After the cavity, a red diode aiming beam is reflected onto a coaxial beam path using a beamsplitter assembly. The combined therapuetic and aiming beams are guided down an articulated arm delivery system to a focusing handpiece. The laser is used in noncontact mode. The System is capable of emitting up to 1.0 Joule of pulsed light at 2.94 um, with a (nominal ) pulsewidth of 300 us. The Skinlight system is designed with 5 major sub-systems: a) A high voltage power supply which converts and rectifies the a.c. mains current to provide regulated power for the flashlamp simmer current and main triggering pulse. b) A cooling system consisting of an internal water flow circuit together with water-to-air heat exchanger. c) An Er:YAG laser rod, capable of generating 1.0 Joule optical pulses at a frequency up to 15 Hz. d) An optical delivery system, interfacing the energy from the laser to the patient via an articulated arm and focusing handpiece. e) The microprocessor based controller which regulates the functions of the laser and allows parameter selection by the user.

    AI/ML Overview

    The provided text describes a medical device, the Fotona Skinlight system, and argues for its substantial equivalence to a predicate device (Schwartz Electro-Optics TriLase 2940). However, the text does not contain any information about acceptance criteria, device performance metrics, or any study that proves the device meets specific acceptance criteria.

    Therefore, I cannot provide the requested table or answer the specific questions about sample sizes, data provenance, expert ground truth, adjudication methods, MRMC studies, standalone performance, or training set details because this information is not present in the provided document.

    The document discusses the laser's physical characteristics, intended use, and its technological similarities to a predicate device to argue for substantial equivalence, which is a regulatory pathway. It does not present clinical trial data or performance studies against predefined acceptance criteria.

    Ask a Question

    Ask a specific question about this device