510(k) Data Aggregation

    K Number
    K972564

    Validate with FDA (Live)

    Date Cleared
    1997-08-25

    (47 days)

    Product Code
    Regulation Number
    890.3860
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    THE TILTMASTER KIT DESIGN IS INTENDED FOR USE ON A POWER AND MANUAL WHEELCHAIR TO PROVIDE PATIENTS WITH POSTERIOR TILT FOR POSITIONING AND SEATING PRESSURE RELIEF.

    Device Description

    THE TILT MASTER CG SYSTEMS (CENTER OF GRAVITY), IS AN AFTERMARKET KIT CONSISTING OF A LINEAR ACTUATOR WITH 900 POUNDS CAPACITY, ALUMINUM AND STEEL BRACKETS, WIRING HARNESS TO SUPPLY VOLTAGE TO THE ACTUATOR, AND A MERCURY SWITCH DRIVER LOCKOUT WHICH RENDERS THE WHEELCHAIR INOPERABLE WHEN TILTED BEYOND 15 DEGREES. THE CG SYSTEM KIT IS DESIGNED TO CONVERT A POWERED OR MANUAL STANDARD WHEELCHAIR TO A POWER RECLINE. THE TILT MASTER CG SYSTEM USES A CENTER OF GRAVITY DESIGN TO MOVE THE PATIENTS CENTER OF GRAVITY FORWARD 6" AS THE SYSTEM TILTS. THIS PROVIDES ADDED SECURITY WHEN IN THE TILTED POSITION. THE TILT MASTER CG SYSTEM ALLOWS THE USER TO HAVE 5 TO 55 DEGREE RANGE OF TILT. THE TILT MASTER CG SYSTEM IS DESIGNED SO IF ANY CATASTROPHIC FAILURE OCCURS WHILE THE SEAT IS IN THE TILT POSITION, THE SAFETY NUT ON THE ACTUATOR WILL ALLOW THE DRIVER TO PUT THE SEAT BACK ON THE DRIVE POSITION AND WILL DISABLE THE TILT MECHANISM. THE DRIVER WILL BE UNABLE TO PUT THE SYSTEM IN THE TILT POSITION ONCE THIS OCCURS.

    AI/ML Overview

    The provided document is a 510(k) premarket notification for the "TILT MASTER CG SYSTEMS (CENTER OF GRAVITY)" and primarily focuses on demonstrating substantial equivalence to predicate devices rather than providing detailed acceptance criteria and a study demonstrating performance against those criteria.

    Therefore, the requested information regarding acceptance criteria, device performance, sample sizes, ground truth establishment, expert qualifications, adjudication methods, and MRMC studies is not available in the provided text.

    The document states "NON CLINICAL TESTING: PLEASE REFER TO THE FOLLOWING ATTACHMENT," indicating that the actual performance study details were provided in a separate attachment, which is not included in the provided text. The text only mentions the device's technical characteristics and intended use.

    Based on the provided text, the following information can be extracted/inferred:

    • Device Name: TILT MASTER CG SYSTEMS (CENTER OF GRAVITY)
    • Intended Use: To provide power recline for posterior tilt for positioning and seating pressure relief on power or manual standard wheelchairs.
    • Technological Characteristics Comparison (to E&J System - a predicate device):
      • TILT MASTER CG SYSTEM has a 6" linear motion (vs. 3" for E&J).
      • TILT MASTER CG SYSTEM uses an oil light bearing roller through a trough means (vs. rolls on cam means for E&J).
      • TILT MASTER CG SYSTEM uses a "higher quality made actuator by LINAK which also has an extra 2 year warranty" (vs. actuator by Motion for E&J).
      • TILT MASTER CG SYSTEM includes a padded contoured back and headrest.
    • Safety Feature: A mercury switch driver lockout renders the wheelchair inoperable when tilted beyond 15 degrees. If a catastrophic failure occurs while tilted, a safety nut on the actuator allows the seat to be put back on the drive position and disables the tilt mechanism.
    • Tilt Range: 5 to 55 degrees.

    Therefore, a table of acceptance criteria and reported device performance, and details about the study proving it, cannot be generated from the given text. The document focuses on the description of the device and its intended use for regulatory clearance.

    Ask a Question

    Ask a specific question about this device

    K Number
    K972563

    Validate with FDA (Live)

    Device Name
    LIFT MASTER
    Date Cleared
    1997-08-22

    (44 days)

    Product Code
    Regulation Number
    890.3860
    Age Range
    0 - 21
    Reference & Predicate Devices
    N/A
    Predicate For
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    THE LIFT MASTER ELEVATING POWER SEAT ASSEMBLY DESIGN IS INTENDED FOR USE ON A POWER AND MANUAL WHEELCHAIR. THE LIFT MASTER WILL ELEVATE PATIENTS TO A GREATER HEIGHT THAN THAT OF THE CONVENTIONAL SEAT HEIGHT OF A WHEELCHAIR.

    Device Description

    THE LIFT MASTER CONSISTS OF A BALL DRIVE PEDESTAL ACTUATOR WITH A LOAD CAPACITY OF 500 LBS., ALUMINUM AND STEEL BRACKETS, SAFETY CABLE, AND WIRING HARNESS. THE LIFT MASTER BEGINS WITH A SEAT TO FLOOR HEIGHT OF 17 1/2" AND ELEVATES 8" TO AN UPPER LIMIT OF 25 1/2". OTHER RANGES WILL BE AVAILABLE UPON REQUEST. THE SYSTEM HAS A SPEED REDUCTION CAPABILITY WHILE IN THE LIFTED POSITION. THE LIFT MASTER HAS A WEIGHT LIMIT OF 250 LBS. AND A HEIGHT LIMIT OF 6'. OPERATES ON REAR WHEEL DRIVE AND OFFERS CUSTOM SEATING CAPABILITIES.

    AI/ML Overview

    Acceptance Criteria and Device Performance for the Lift Master System Wheelchair Elevator

    The Lift Master System Wheelchair Elevator is designed to enhance the functionality of wheelchairs by allowing elevation of the user. The primary acceptance criteria for this device relate to its stability when in use, particularly when elevated.

    1. Acceptance Criteria and Reported Device Performance

    Acceptance CriteriaReported Device Performance
    Stability (Non-elevated position): When driven in the recommended position, the Lift Master should have the same stability as the wheelchair manufacturer's had before installation of the Lift Master."WHEN DRIVEN IN THE RECOMMENDED POSITION, LIFT MASTER HAS THE SAME STABILITY AS THE WHEELCHAIR MANUFACTURER'S HAD BEFORE INSTALLATION OF THE LIFT MASTER." (Statement indicates compliance without specifying quantitative metrics or comparative data beyond a direct assertion of equivalence).
    Stability (Elevated position): When driven in the elevated position on terrain with inclines from 0 to 9 degrees, in the designated drive position with the maximum weight limit of 250 lbs., the wheelchair cannot be tipped or turned over."WHEN DRIVEN IN THE ELEVATED POSITION ON THE TERRAIN OF 0 DEGREES TO 9 DEGREES, IN THE DESIGNATED DRIVE I POSITION WITH THE MAXIMUM WEIGHT LIMIT OF 250 LBS., THE WHEELCHAIR CAN NOT BE TIPPED OR TURNED OVER AS OUR PHYSICAL TESTING HAS SHOWN UNDER THESE CONDITIONS." (Statement indicates compliance through physical testing demonstrating no tipping or overturning under specified conditions).

    2. Sample Size Used for the Test Set and Data Provenance

    The provided document describes "physical testing" but does not specify the sample size (i.e., number of wheelchairs, number of test runs, or number of individuals) used for the test set.

    Data Provenance: The data appears to be retrospective as it describes testing already conducted by the manufacturer ("our physical testing has shown"). The country of origin of the data is not explicitly stated, but the manufacturer is based in Katy, TX, USA.

    3. Number of Experts Used to Establish the Ground Truth for the Test Set and Qualifications

    There is no mention of experts being used to establish a "ground truth" for the test set in the provided document. The stability claims are based on "physical testing" conducted by the manufacturer.

    4. Adjudication Method

    No adjudication method is described. The stability claims are presented as direct observations from "physical testing."

    5. Multi-Reader Multi-Case (MRMC) Comparative Effectiveness Study

    There is no indication that a Multi-Reader Multi-Case (MRMC) comparative effectiveness study was done. This type of study typically involves human readers (e.g., medical professionals) assessing cases with and without AI assistance to measure improvement in accuracy or efficiency. The Lift Master is a mechanical device, not an AI-powered diagnostic tool, so an MRMC study would not be applicable here.

    6. Standalone Performance Study

    Yes, a standalone performance study was done. The document explicitly states "NON CLINICAL TESTING: ATTACHMENT." and then details "LIFT MASTER TESTING." This testing was conducted on the device itself ("the wheelchair can not be tipped or turned over as our physical testing has shown") without human interaction as part of the performance evaluation, focusing solely on the device's mechanical stability.

    7. Type of Ground Truth Used

    The ground truth used for the stability testing was empirical observation/physical testing results. The claims are based on directly observing the device's behavior (whether it tipped or turned over) under controlled conditions, not on expert consensus, pathology, or outcomes data in a medical sense.

    8. Sample Size for the Training Set

    This question is not applicable. The Lift Master System Wheelchair Elevator is a mechanical device, not an algorithm or AI system that requires a "training set" in the computational sense. The design and engineering would have gone through iterative development and testing, but not "training" with a dataset.

    9. How the Ground Truth for the Training Set Was Established

    This question is not applicable as there is no "training set" for a mechanical device like the Lift Master. The design and validation would be based on engineering principles, materials science, and physical prototypes.

    Ask a Question

    Ask a specific question about this device

    K Number
    K961744

    Validate with FDA (Live)

    Date Cleared
    1996-07-25

    (110 days)

    Product Code
    Regulation Number
    890.3860
    Age Range
    N/A
    Reference & Predicate Devices
    N/A
    Predicate For
    N/A
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use
    Device Description
    AI/ML Overview