510(k) Data Aggregation

    K Number
    K171515

    Validate with FDA (Live)

    Device Name
    NHAC 16
    Date Cleared
    2017-07-26

    (63 days)

    Product Code
    Regulation Number
    892.1000
    Reference & Predicate Devices
    Predicate For
    N/A
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The NHAC 16 is a local coil (receive only) and is intended to be used in conjunction with 1.5T or 3.0T magnetic resonance imaging (MRI) systems by Philips or Siemens and can be used in conjunction with the MR Diagnostics Incubator System nomag® IC. It provides MR images of the neonatal head, non-invasively and without the use of ionizing radiation.

    Device Description

    The NHAC 16 is a 16-channel coil (receive only) and is intended to produce high resolution images of the neonate head and brain.

    The NHAC 16 serves solely as a receiving coil for the reception of high frequency signals from the hydrogen nuclei. The hydrogen nuclei are induced into precession by the transmitting coil of the MRT device. The precessing magnetization induces potential differences in the NHAC 16 which are processed by the MRT system.

    Used in an MR Scanner or used in the MR Diagnostics Incubator System nomag® IC and an MR Scanner, the NHAC 16 is indicated for use as a diagnostic imaging device to provide transversal, sagittal, coronal and oblique images of the internal structures of the head.

    When interpreted by a trained physician, these images provide information that can be useful in the determination of a diagnosis. The excited nucleus is 1H (Hydrogen).

    The signal received by the coils is dependent upon the MRI parameters (T1 or spin-lattice relaxation time, T2 or spin-spin relaxation time, density of nuclei, flow velocity and chemical shift).

    AI/ML Overview

    I am sorry, but the provided text does not contain any information about acceptance criteria or a study that proves the device meets those criteria. The document is an FDA 510(k) clearance letter for a medical device (NHAC 16, a neonatal head array coil for MRI) and a summary of its comparison to a predicate device.

    It primarily discusses:

    • The device's intended use and description.
    • Comparison of its electrical, mechanical design, principles of operation, materials, and power supply to a predicate device.
    • The conclusion that the modified device is substantially equivalent to the predicate device and raises no new concerns of safety or efficacy.
    • A mention of "General testing was performed to ensure that functional requirements were met and that the coil executes as expected. Performance testing was conducted using phantoms and accepted imaging quality metrics." However, no specific acceptance criteria, performance metrics, or study details are provided.
    • It also states that "sample clinical images of the neonatal head were not necessary to support the premarket submission."

    Therefore, I cannot fulfill your request to describe the acceptance criteria and the study that proves the device meets them based on the given text.

    Ask a Question

    Ask a specific question about this device

    K Number
    K091047

    Validate with FDA (Live)

    Date Cleared
    2010-08-18

    (492 days)

    Product Code
    Regulation Number
    892.1000
    Reference & Predicate Devices
    Predicate For
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    Used in a MR Scanner or used in the LMT nomag IC incubator and a MR Scanner, the Neonate Array Colls (receive only) are indicated for use as a diagnostic imaging device to provide transversal, sacittel, connel, and chical device to provide (rocolve only) are indicated for use as a diagnostic imaging structures of the structures of the - head (Neonate Head Array Coil) . - spine, torso (Neonate Body Array Coil). . When interpreted by a trained physician, these images provide information that can be useful in the determination of a diagnosis. The excited nucleus is 1H (Proton). The signal received by the coils is dependent upon the MRI parameters (T1 (Proton). Intice relaxation time. T2 as an and is dependent upon the MRI parameters (T1 or spinlattice relaxation time, T2 or spin-spin relaxation time, density of nuclei, flow velocity and chemical shift). The Neonate Array coils are compatible to Siemens and Philips MRTs with 1 ET or 3 oT MRTs with 1.5T or 3.0T.

    Device Description

    The Neonate Array Coils (in the following NAC) is a phased array coil with rectangle loop design and integrated RF preamp per channel. It is a receive-only coil with rectangle for horizontal B-field scanners with field stars of for horizontal B-field scanners with field strengths of 1.5T of 3.0T.

    AI/ML Overview

    The provided text does not contain a study or acceptance criteria for device performance. It is a 510(k) summary for the LMT Medical Systems GmbH Neonate Array Coils, which establishes substantial equivalence to a predicate device.

    The document states that the "safety and performance parameters specified by the FDA guidance for MR Diagnostic Devices are met by the NAC," and lists "Imaging" under performance and various safety aspects. However, it does not provide specific acceptance criteria (e.g., target signal-to-noise ratio, image resolution, specific diagnostic accuracy metrics) or details of a study that evaluates the device's performance against such criteria.

    Therefore, I cannot provide the requested information regarding acceptance criteria and a study proving the device meets them, as this information is not present in the given text.