Search Filters

Search Results

Found 1 results

510(k) Data Aggregation

    K Number
    K961645

    Validate with FDA (Live)

    Device Name
    MRS-2D
    Date Cleared
    1996-10-31

    (185 days)

    Product Code
    Regulation Number
    882.5050
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    N/A
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    BioLex is indicated for relaxation training using alpha EEG biofeedback. In the protocol for relaxation training, BioLex provides a visual and/or auditory signal that corresponds to the patient's increase in alpha activity as an indicator of achieving a state of relaxation.

    Device Description

    The NRS-2D is a two channel electrophysiological signal acquisition and biofeedback device. The product is designed for use with a standard IBM PC/AT compatible computer and associated peripheral equipment. When assembled with the computer, the NRS-2D system will acquire EEG and biofeedback data, perform signal spectral analysis and quantification and provide auditory and/or visual feedback. At the user's discretion the NRS-2D can be factory configured as a single channel device.

    AI/ML Overview

    The provided text describes the Lexicor NRS-2D, a two-channel electrophysiological signal acquisition and biofeedback device. It focuses on device specifications and intended use but does not contain information about acceptance criteria or specific studies proving the device meets acceptance criteria.

    Therefore, I cannot provide the requested information from the given text.

    The document primarily covers:

    • Device Description: The NRS-2D is a two-channel device for acquiring EEG and biofeedback data, performing signal spectral analysis, and providing auditory/visual feedback. It can also be configured as a single-channel device.
    • Intended Use: For relaxation training using alpha EEG biofeedback, providing visual and/or auditory signals corresponding to increased alpha activity.
    • Warnings and Contraindications: Patients unwilling or unable to understand feedback principles, those experiencing anxiety from EEG biofeedback, and a warning regarding potential causal relationship between EEG training and seizures in epilepsy.
    • Technological Characteristics: Details about the acquisition and preprocessing unit, including filters (lowpass, highpass, notch), A/D converter, microprocessor control, and communication with a PC. Specifications like sampling rate (128Hz), gain (8,000), and electrode continuity checking are mentioned.
    • Device Specifications Table: A table outlining physical dimensions, signal acquisition parameters (channels, sampling rate, frequency resolution, noise, notch filtering, CMRR, gain, filters, input impedance, A/D resolution), and power details (AC power, battery power).
    Ask a Question

    Ask a specific question about this device

    Page 1 of 1