Found 2 results

510(k) Data Aggregation

    K Number
    K974724

    Validate with FDA (Live)

    Manufacturer
    Date Cleared
    1998-03-02

    (74 days)

    Product Code
    Regulation Number
    886.5928
    Reference & Predicate Devices
    N/A
    Predicate For
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The New Comfort Contact Lens Care Accessory is intended for use in conjunction with contact lens solutions as an accessory in the cleaning of contact lenses.

    The New Comfort Contact lens Care Accessory is indicatod as aid for cleaning as an accessory for soft hydrophilic lenses and gas pormoablo lonsos whon usod with the appropriate Allergan® Soft Mate® solutions such as the Consept® Cleaning and Disinfoction Systom which is comprisod of the Allergan® Soft Mato® Consept®-1 Cleaning and Disinfecting solution and Allergen® Soft Mate® Consept - 2 Neutralizing and Rinsing Solution or Spray. The New Comfort Contact Lens Care Accessory is indicated for use for gas permeable solutions such as Allergan® Gas Permeable Daily Cleaner and Allergan® ComfortCare GP Wetting and Soaking Solution. The New Comfort Contact Lens Care Accessory may be used for a receptacle for chemical disinfection.

    Device Description

    The New Comfort Ultrasonic Contact Lens Care Accessory uses a piezo-electric crystal to generate a wave form, in a reservoir containing a specific volume of fluid. Cavitation in fluid results in the generation of microscopic bubbles that implode upon the lens surface. The matrix of frequency, duration of ultrasound, and the control of temperature rise in the fluid medium leads to cleaning when a specific contact lens solution is present. The New Comfort device uses standard power (110 v/120 v). There is a four (4) foot cord and a UL approved wall transformer.

    The New Comfort device consists of the housing, lens baskets, a reservoir, electronics and a transducer. All components that come in contact with contact lenses or solutions are of medical grade composition and have been used in legally marketed predicate devices in the United States. The housing is injection molded of ABS. The baskets and supporting structure are injection molded from ABS. The reservoir is deep drawn stainless steel, is passivated and electropolished. The electronic circuitry has been used in other cleaning applications in other industries for years. The single crystal is affixed directly to the bottom of the reservoir with an epoxy generally used in cleaning applications in the ultrasound industry.

    AI/ML Overview

    Acceptance Criteria and Device Performance for "The New Comfort Contact Lens Care Accessory"

    This document describes the acceptance criteria and the study that demonstrates the "New Comfort Contact Lens Care Accessory" meets these criteria, based on the provided 510(k) summary (K974724).

    1. Table of Acceptance Criteria and Reported Device Performance

    The 510(k) summary does not explicitly list "acceptance criteria" in a formal, quantifiable manner. Instead, the demonstration of substantial equivalence is based on the device performing comparably to legally marketed predicate devices, particularly regarding its impact on contact lenses during cleaning cycles. The acceptance criteria can be inferred from the study's objective: to ensure no adverse changes to the contact lenses after prolonged use with the device.

    Acceptance Criteria (Inferred from Study Objective)Reported Device Performance (New Comfort)
    No changes in contact lens color after 30 cleaning cycles.No changes noted in color.
    No changes in contact lens clarity after 30 cleaning cycles.No changes noted in clarity.
    No changes in contact lens power after 30 cleaning cycles.No changes noted in power.
    No changes in contact lens diameter after 30 cleaning cycles.No changes noted in diameter.
    No changes in contact lens base curve after 30 cleaning cycles.No changes noted in base curve.
    No deposits or residue observed on contact lenses after 30 cleaning cycles.No deposits or residue noted on any of the lenses.
    No damage to contact lenses observed after 30 cleaning cycles.No damage noted on any of the lenses.

    2. Sample Size Used for the Test Set and Data Provenance

    • Sample Size for Test Set: Lenses were selected from "Group 1, Group 3, Group 4 and the Gas Permeable class." The exact number of lenses used is not specified in the document, but it includes representatives from key contact lens types.
    • Data Provenance: The study was conducted by an optometrist in a large ophthalmology practice, strongly suggesting prospective data collection. The country of origin is not explicitly stated, but given the 510(k) submission to the FDA, it is highly likely to be the United States.

    3. Number of Experts Used to Establish Ground Truth for the Test Set and Qualifications

    • Number of Experts: One expert.
    • Qualifications of Expert: The study was conducted by "an optometrist who is director of optometric services in a large ophthalmology practice." This indicates a qualified eye care professional with clinical experience relevant to contact lenses.

    4. Adjudication Method for the Test Set

    • Adjudication Method: None explicitly stated. The evaluation was conducted by a single optometrist. There's no mention of a consensus process or multiple reviewers for the ground truth establishment.

    5. Multi-Reader Multi-Case (MRMC) Comparative Effectiveness Study

    • MRMC Study Done: No. This device is an accessory for cleaning contact lenses, not an diagnostic imaging tool where MRMC studies are typically performed. The evaluation focuses on the physical effects of the device on lenses, not on human interpretation or diagnostic accuracy.

    6. Standalone (Algorithm Only) Performance Study

    • Standalone Study Done: Yes, in essence. The described study evaluates the device's performance (its effects on contact lenses) in isolation from human intervention in the cleaning process itself. The optometrist observes and measures the lens characteristics after the device has completed its function.

    7. Type of Ground Truth Used

    • Type of Ground Truth: The ground truth was established through expert observation and measurement by a qualified optometrist. This involves physical and optical parameter measurements (color, clarity, power, diameter, base curve) and visual inspection for deposits, residue, or damage.

    8. Sample Size for the Training Set

    • The 510(k) summary describes a performance study for the device, not a machine learning model. Therefore, there is no concept of a "training set" as would be applicable to AI/ML devices. The device operates mechanistically based on physics (ultrasound), not learned patterns.

    9. How the Ground Truth for the Training Set Was Established

    • As stated above, this is not applicable as there is no training set for this type of device.
    Ask a Question

    Ask a specific question about this device

    K Number
    K962112

    Validate with FDA (Live)

    Manufacturer
    Date Cleared
    1996-11-29

    (182 days)

    Product Code
    Regulation Number
    886.5928
    Reference & Predicate Devices
    N/A
    Predicate For
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The Lena Comfort Contact Lens Care Accessory is intended for use in conjunction with contact lens solutions as an accessory in the cleaning of contact lenses,

    Lens Comfort is Indicated as aid for cleaning as on accossory for soft hydrophilic lanses and gas permeable lenses when used with the appropriate Barnea-i hind® Soft Mate solutions auch as the Consept Cleaning and Disintection System which is comprised of the Bernes-Hinde Soft Mare Consept . 1 Cleaning and Disinfecting solution and Barnes-Hinde Soft Mate® Consepte-2 Neutralizing and Pinaing Solution or Spray. The Lans Comfort Contact Lons Care Accessory Is indicalad for use for gas permeable solutions auch as Barnes. Hind® Gas Permeable Daily Cleaner and Barnes-Hind® ComfortCare GP Welting and Solution. The Lens Comfort Contact Lons Care Accessory may be used for a receptacie for chamical disinfection.

    Device Description

    The Lens Comfort Ultrasonic Contact Lens Care Accessory uses a plezo-electric crystal to generate a wave form. In a reservoir containing a specific volume of fluid. Cavitation in fluid results in the generation of microscopic bubbles that implode upon the lens surface. The matrix of frequency, duration of ultrasound, and the control of tomperature rise in the fluid medium leads to cleaning when a specific contact lens solution is present. The Lans Comfort device uses standerd power (110 v/120 v). There is a four (4) foul cord and a UL approved wall transformer.

    The Lens Comfort device consists of the housing, lens beskets, a reasivoir, electronics and a transducer. All components that come in contact with contact lenses or solutions are of medical grade composition and have been used in legally merkated predicate devices in the United States. The housing is injection molded of polycarbonate. The baskets and supporting structure are injection molded from polyethylene. The reservoir is deep drawn stallnioss steel, is passivated and pollshed. The electronic circultry has been used in other cleaning applications in other industries for years. The single crystal is affixed directly to the bottom of the reservoir with an epoxy generally used in cleaning applications in the ultrasound industry.

    AI/ML Overview

    Here's an analysis of the provided 510(k) summary regarding the Lens Comfort Ultrasonic Contact Lens Care Accessory, focusing on acceptance criteria and study details:

    1. Table of Acceptance Criteria and Reported Device Performance

    Acceptance CriteriaReported Device Performance
    No changes in lens physical and optical parameters after cleaning: Color, Clarity, Power, Diameter, Base Curve."No changes were noted in color, clarity, power, diameter or base curve."
    No deposits or residue on lenses after cleaning."The lenses all appeared clear and no deposits or residue or damage were noted on any of the lenses."
    No damage to lenses after cleaning."The lenses all appeared clear and no deposits or residue or damage were noted on any of the lenses."
    Compatibility with specified contact lens solutions."Lens Comfort references the same solutions [Sole/Barnes-Hind® Solutions] and data."

    2. Sample Size Used for the Test Set and Data Provenance

    The document does not explicitly state the number or type (e.g., brand, material) of unique lenses used in the test set. It mentions "Lenses were selected from Group 1, Group 3, Group 4 and the Gas Permeable class." It also states, "Thirty (30) cycles were performed on all lenses." This suggests a protocol that subjects each tested lens to 30 cleaning cycles.

    The data provenance is not explicitly stated in terms of country of origin. The study was "conducted by an optometrist who is director of optometric services in a large ophthalmology practice," implying a clinical setting, but whether this was in the US or elsewhere is not specified. The study appears to be prospective as it involves the active testing of the device according to a protocol.

    3. Number of Experts Used to Establish the Ground Truth for the Test Set and Qualifications of Those Experts

    The ground truth was established by one expert: "an optometrist who is director of optometric services in a large ophthalmology practice." Their qualifications as an optometrist and director of optometric services suggest expertise in evaluating contact lens health and performance. No further details on years of experience or board certifications are provided.

    4. Adjudication Method for the Test Set

    There is no mention of an adjudication method. The evaluation appears to have been performed by a single optometrist, who assessed the lenses for changes.

    5. If a Multi-Reader Multi-Case (MRMC) Comparative Effectiveness Study Was Done

    No, a Multi-Reader Multi-Case (MRMC) comparative effectiveness study was not done. The study focuses solely on the performance of the Lens Comfort device against established cleaning standards, not on comparing human reader performance with or without AI assistance.

    6. If a Standalone (i.e., algorithm only without human-in-the-loop performance) Was Done

    This question is not applicable. The device is a physical accessory for cleaning contact lenses, not an algorithm or AI system. The "standalone" performance here refers to the device's ability to clean lenses without human intervention in the cleaning process, which it is designed to do. Human evaluation is required for the assessment of the cleaning outcome.

    7. The Type of Ground Truth Used

    The ground truth used was expert assessment/observation by an optometrist. This involved the direct measurement and visual inspection of physical and optical parameters of the contact lenses.

    8. The Sample Size for the Training Set

    This question is not applicable. The Lens Comfort device is a physical product, not an AI or machine learning model that requires a "training set."

    9. How the Ground Truth for the Training Set Was Established

    This question is not applicable, as there is no training set for this type of device.