510(k) Data Aggregation

    K Number
    K081781

    Validate with FDA (Live)

    Device Name
    NUWAV
    Date Cleared
    2008-07-09

    (15 days)

    Product Code
    Regulation Number
    892.1560
    Reference & Predicate Devices
    Predicate For
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The NuWav Ultrasound Probe System is intended to used to perform diagnostic general ultrasound studies including Fetal, Abdominal (Solid Organs, Aneurysms, bladder), Pediatric, Small organ (breast, thyroid, bladder, testes, prostate), Neonatal Cephalic, Cardiac, Trans-vaginal, Trans-rectal, Peripheral Vascular, and Musculoskeletal (Conventional and Superficial). The system provides imaging for guidance of biopsy and imaging to assist in the placement of needles or other anatomical structures as well as performing Urodynamic Studies.

    Device Description

    Not Found

    AI/ML Overview

    The provided text is a 510(k) premarket notification for the "NuWay Ultrasound Probe System." It primarily details the regulatory clearance for the device and its various transducers, listing the intended uses. However, it does not contain any information about acceptance criteria, device performance studies, sample sizes, ground truth establishment, or expert involvement for studying the device's diagnostic performance.

    The document confirms that the device is "substantially equivalent" to legally marketed predicate devices, meaning that its performance does not need to be independently proven against new acceptance criteria. Instead, it relies on the established safety and effectiveness of its predicate.

    Therefore, I cannot provide the requested information from the given text.

    Summary of what cannot be provided from the text:

    1. A table of acceptance criteria and the reported device performance: Not present. The document focuses on regulatory clearance by substantial equivalence, not performance metrics against specific acceptance criteria.
    2. Sample sized used for the test set and the data provenance: Not present. No performance study details are included.
    3. Number of experts used to establish the ground truth for the test set and the qualifications of those experts: Not present. No performance study details are included.
    4. Adjudication method for the test set: Not present. No performance study details are included.
    5. If a multi reader multi case (MRMC) comparative effectiveness study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance: Not present. This device is a diagnostic ultrasound system, not an AI-assisted diagnostic tool.
    6. If a standalone (i.e. algorithm only without human-in-the loop performance) was done: Not present. This is a hardware device, not a standalone algorithm.
    7. The type of ground truth used (expert consensus, pathology, outcomes data, etc.): Not present. No performance study details are included.
    8. The sample size for the training set: Not present. This is a hardware device; no training set for an algorithm is mentioned.
    9. How the ground truth for the training set was established: Not present. This is a hardware device; no training set for an algorithm is mentioned.
    Ask a Question

    Ask a specific question about this device

    K Number
    K073552

    Validate with FDA (Live)

    Date Cleared
    2008-03-05

    (78 days)

    Product Code
    Regulation Number
    876.1620
    Reference & Predicate Devices
    N/A
    Predicate For
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    Laborie Urodynamic systems are intended for Urodynamics testing. The traditional equipment performs standard tests including uroflowmeter, cystometry, micturition, electromyography and urethral pressure profiles. The accessory to our standard equipment, Tetra, uses near infrared spectroscopy, for non-invasive testing of bladder activity, aiding in the diagnosis of patients with lower urinary tract symptoms - that is patients who suffer from Urinary Incontinence.

    All Urodynamic equipment including the Laborie Urodynamic System with Tetra Accessory are for use under the direction of a licensed physical or health care professional in an office or hospital setting.

    Device Description

    The complete device includes traditional Urodynamic system and the Tetra accessory. That is all the standard components, for uroflowmetry and pressure measurement, and the new non-invasive component the Tetra accessory to detect bladder activity.

    AI/ML Overview

    The provided 510(k) summary for the Laborie Medical Technologies Urodynamic System with Tetra Accessory is for a Class II medical device that measures urodynamic parameters. It's important to note that this submission is primarily focused on demonstrating substantial equivalence to a predicate device, rather than proving novel effectiveness through rigorous clinical trials with specific acceptance criteria in the same way a new drug or a high-risk AI device might.

    Therefore, the study information requested regarding acceptance criteria and performance metrics (e.g., sensitivity, specificity, reader improvement with AI) is not applicable in the context of this 510(k) summary. The summary focuses on bench testing and a clinical study to confirm the efficacy of the system and its accessory, as well as safety testing, but these are not described with specific acceptance criteria in terms of diagnostic performance.

    Here's an breakdown of the available information:

    1. A table of acceptance criteria and the reported device performance:

    This information is not provided in the 510(k) summary in the traditional sense of diagnostic performance metrics with defined acceptance criteria. The summary lists technical specifications for the UDS-94 and Tetra Accessory, which are inherent design parameters rather than performance outcomes against a gold standard in a diagnostic context.

    Metric (UDS-94 System)Reported Performance
    Uroflow Rate0 to 50 ml/s
    Uroflow Volume0 to 1100 ml
    Pressure-40 to 350 cm H2O
    EMG Frequency2 to 800 Hz
    Pump Rate5 to 140 ml/min
    UPP Puller0.5 to 3 mm/s
    Infusion0 to 1000 ml
    T-Doc-68 to 408 cmH2O
    Data Conversion RateMin 10 Hz up to 1000 Hz (optional up to 5000 Hz)
    Metric (Tetra Accessory)Reported Performance
    Wavelengths785 nm, 808nm, 830nm
    Energy OutputUp to 350 mJ
    Type of OperationPulsed Only, 4 µsec
    Class of Laser ProductsClass I

    2. Sample size used for the test set and the data provenance (e.g., country of origin of the data, retrospective or prospective):

    The 510(k) summary states "Bench and clinical studies have confirmed the efficacy of the Laborie Urodynamic System with Tetra Accessory," but does not provide details on the sample size, data provenance, or study design (retrospective/prospective) for these studies.

    3. Number of experts used to establish the ground truth for the test set and the qualifications of those experts:

    This information is not provided in the 510(k) summary. Since the submission focuses on substantial equivalence for a device measuring physiological parameters, the method of "establishing ground truth" for diagnostic accuracy involving expert consensus would not typically be a primary focus for this type of device.

    4. Adjudication method (e.g., 2+1, 3+1, none) for the test set:

    This information is not provided.

    5. If a multi-reader multi-case (MRMC) comparative effectiveness study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance:

    A multi-reader multi-case (MRMC) comparative effectiveness study is not applicable and was not performed. The Tetra Accessory uses near-infrared spectroscopy for non-invasive bladder activity detection; it is a measurement device, not an AI diagnostic tool designed to assist human readers in interpreting complex images or data in a way that would require an MRMC study.

    6. If a standalone (i.e., algorithm only without human-in-the-loop performance) was done:

    A standalone algorithm performance study is not applicable as the device is not an AI algorithm. The Tetra accessory is a physical component that uses near-infrared spectroscopy to detect bladder activity. It's a measurement device intended for use by a healthcare professional, not a standalone diagnostic algorithm.

    7. The type of ground truth used (expert consensus, pathology, outcomes data, etc.):

    The 510(k) summary does not specify the "ground truth" used for the efficacy confirmation. For a urodynamic system, "efficacy" would likely relate to the accuracy and reliability of its physiological measurements compared to established standards or clinical observations, rather than a diagnostic 'ground truth' like pathology.

    8. The sample size for the training set:

    As this is not an AI/ML device, there is no training set in the conventional sense.

    9. How the ground truth for the training set was established:

    As mentioned above, there is no training set and therefore no ground truth establishment for a training set.

    In summary:

    The provided document describes a 510(k) submission for a medical device that measures physiological parameters. The primary goal of this submission is to demonstrate substantial equivalence to a predicate device, focusing on technical specifications and safety rather than a detailed performance study with diagnostic acceptance criteria. As such, many of the requested details regarding AI/ML device performance validation metrics are not applicable to this submission.