    K Number
    K250673

    Validate with FDA (Live)

    Device Name
    CERABIEN MiLai
    Date Cleared
    2025-05-29

    (84 days)

    Product Code
    Regulation Number
    872.6660
    Panel
    Dental
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    N/A
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    For use in prosthetic dentistry to create an all-ceramic prosthesis.

    • Ceramic for coverage of a zirconia substructure
    • Ceramic for coverage of a lithium disilicate substructure
      [CTE: 9.5~11.0×10-6/K (50-500°C)]
    Device Description

    CERABIEN MiLai is a specific type of porcelain for dental restorations. The system consists of Powder, Paste and Liquids for powder/paste, to be applied utilizing layering technique and baked onto a ceramic frame of zirconia (ZrO2) or different lithium disilicate glasses.

    AI/ML Overview

    The provided FDA 510(k) clearance letter pertains to CERABIEN MiLai, a porcelain powder for clinical use in prosthetic dentistry. The documentation focuses on demonstrating substantial equivalence to predicate devices through compliance with established international standards for dental ceramics.

    1. A table of acceptance criteria and the reported device performance

    The acceptance criteria are derived from the requirements of the recognized consensus standards ISO 6872:2015 and ISO 9693:2019. The reported device performance indicates compliance with these standards. Specific quantitative acceptance criteria or detailed device performance values (e.g., specific flexural strength values, CTE measurements) are not explicitly itemized in the document but are stated to have been met.

    Acceptance CriteriaReported Device Performance
    ISO 6872:2015 (Dental ceramic - Strength): This standard specifies requirements for dental ceramic materials for fixed dental prostheses, including flexural strength. The specific numerical acceptance criteria within this standard are not detailed in the provided document, but compliance implies meeting these thresholds.The subject device met the requirements of ISO 6872:2015, indicating its mechanical strength properties are suitable for its intended use and comparable to predicate devices.
    ISO 9693:2019 (Dental ceramic - Compatibility): This standard specifies requirements for the compatibility of ceramic materials intended for veneering metallic and ceramic substructures for dental restorations. It includes tests for thermal compatibility (e.g., thermal shock) and bond strength. For the thermal shocking testing, the acceptance criterion implies no cracking, checking, or delamination after the specified thermal cycles.The subject device met the requirements of ISO 9693:2019 for compatibility testing for ceramic-ceramic systems. Specifically, it met the requirement of thermal shocking testing according to ISO 9693:2019, confirming its suitability with zirconia and lithium disilicate substructures within the specified CTE range (9.5~11.0×10-6/K).
    Thermal Shock Testing (Specifically for CTE range 9.5~11.0×10-6/K): The specific acceptance criterion for the thermal shocking testing with different lithium disilicate substrates is that the device "meets the requirement of thermal shocking testing according to ISO 9693:2019." This implies no failures such as cracking or delamination.The subject device met the requirement of thermal shocking testing according to ISO 9693:2019 when tested with different lithium disilicate substrates with CTEs ranging from 9.5×10-6/K to 11.0×10-6/K.

    2. Sample sized used for the test set and the data provenance (e.g. country of origin of the data, retrospective or prospective)

    The document does not explicitly state the sample sizes used for the non-clinical tests (physical and mechanical tests, thermal shocking tests). It only indicates that "Physical and mechanical tests were conducted according to ISO 6872: 2015 and ISO 9693: 2019" and "the thermal shocking testing was conducted according to ISO 9693: 2019."
    The provenance of the data (country of origin, retrospective/prospective) is not mentioned. However, since the applicant is Kuraray Noritake Dental Inc. located in Tokyo, Japan, it is reasonable to infer the testing was conducted either in Japan or under their direction.

    3. Number of experts used to establish the ground truth for the test set and the qualifications of those experts (e.g. radiologist with 10 years of experience)

    This is not applicable as the device is a material (porcelain powder) for dental prosthetics, not a diagnostic or screening device that requires expert interpretation for ground truth establishment. The performance is assessed through objective physical and mechanical tests based on recognized international standards.

    4. Adjudication method (e.g. 2+1, 3+1, none) for the test set

    This is not applicable for a physical material testing study. Adjudication methods like 2+1 or 3+1 are used in studies involving human interpretation or diagnostic agreement, which is not the case here.

    5. If a multi reader multi case (MRMC) comparative effectiveness study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance

    This is not applicable. MRMC studies are typically performed for AI or diagnostic imaging devices where human readers interpret medical images. The CERABIEN MiLai is a dental material, and its performance is evaluated through non-clinical physical and mechanical testing.

    6. If a standalone (i.e. algorithm only without human-in-the-loop performance) was done

    This is not applicable. The device is a material, not an algorithm. Its performance is inherent to its physical and chemical properties and is tested in a standalone manner against established standards without human-in-the-loop interaction in the performance evaluation.

    7. The type of ground truth used (expert consensus, pathology, outcomes data, etc)

    For this type of device, the "ground truth" is established by the well-defined physical and mechanical requirements and test methods outlined in the recognized international standards ISO 6872:2015 and ISO 9693:2019. This includes objective measurements of properties like flexural strength and thermal compatibility, rather than subjective expert consensus or pathology.

    8. The sample size for the training set

    This is not applicable. The device is a physical product, not a machine learning algorithm. Therefore, there is no "training set" in the context of AI.

    9. How the ground truth for the training set was established

    This is not applicable for the reasons mentioned in point 8.

    Ask a Question

    Ask a specific question about this device

    K Number
    K233285

    Validate with FDA (Live)

    Date Cleared
    2024-05-24

    (238 days)

    Product Code
    Regulation Number
    872.3630
    Panel
    Dental
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    N/A
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    KATANA Zirconia ONE For IMPLANT is intended for use in partially or fully edentulous mandibles and maxillae in support of single cement-retained restorations.

    For the SBL 3.3 L titanium bases, the indication is restricted to the replacement of single lateral incisors in the maxilla and lateral and central incisors in the mandible.

    KATANA Zirconia ONE For IMPLANT is used in combination with the TiBase and Sirona Dental CAD/CAM System. KATANA Zirconia ONE For IMPLANT cemented to the TiBase is recommended for two-piece hybrid abutments for single tooth restorations and hybrid abutment crowns, used in conjunction with endosseous dental implants.

    Compatible implant systems and TiBase are as follows.

    Device Description

    The KATANA Zirconia ONE For IMPLANT mesostructure material (conforming to ISO 6872:2015) is a pre-sintered zirconia block to be used as the ceramic mesostructure component of a two-piece titanium base abutment. KATANA Zirconia ONE For IMPLANT is compatible with the specified TiBase and the CAD/CAM component of the Sirona Dental CAD/CAM system (K193408, K200191) as identified in the Indications for Use. This device is further processed by the trained professional to make individually designed mesostructure that are milled into the desired shape of a hybrid abutment or hybrid abutment crown.

    The Zirconia block has identical composition as our own previously cleared reference device, KATANA Zirconia Block (K190436) under product code "EIH".

    The mesostructure material of KATANA Zirconia ONE For IMPLANT is available in shades, A1, A2, A3, A3.5, B1, B2, C1, C2, D2 and NW for flexibility and application variety to meet individual patient needs. The mesostructure material of KATANA Zirconia ONE For IMPLANT is available with one block size and two sizes of access hole, which is small (S) and large (L).

    The abutment must be sterilized after the cementation of the CAD/CAM patient matched mesostructure on the pre-manufactured titanium base component. PANAVIA SA Cement Universal (K183537) is used as the cement to set the mesostructure material to TiBase when the mesostructure material of the subject device set to TiBase prior to sterilization.

    Dentsply Sirona has issued a letter of authorization indicating that the subject mesostructure material of the subject device can be selected in combination with the CAD/CAM system. Kuraray Noritake Dental and Dentsply Sirona have a business agreement for adding this new material to the Sirona CAD/CAM system. Kuraray Noritake Dental has worked with Dentsply Sirona to implement their new material into the Sirona CAD/CAM system libraries.

    KATANA Zirconia ONE For IMPLANT which is the subject of this premarket notification consists of:

    • Sirona Dental CAD/CAM System with CEREC Chairside Software or with inLab Software
    • Sirona TiBase
    • . KATANA Zirconia ONE mesostructured blocks
    AI/ML Overview

    The provided text is a 510(k) summary for a dental device, specifically a zirconia block for implant mesostructures. It details the device's indications for use, design, material composition, and technical characteristics, comparing it to predicate and reference devices.

    Here's the breakdown of the acceptance criteria and study information:

    1. Table of Acceptance Criteria and Reported Device Performance

    Acceptance Criteria / Performance AspectDevice Performance / Standards Met
    Material CompositionIdentical to reference device KATANA Zirconia Block (K190436)
    BiocompatibilityEvaluated per ISO 10993 series and ISO 7405; meets requirements
    Material Standards (Zirconia Ceramic)Conforms to ISO 6872:2015
    Dynamic Fatigue Test (Implants)Performed according to ISO 14801:2016 for worst-case representative devices
    SterilizationValidated per ISO 17665-1, achieving SAL of at least 10^-6
    MR Environment CompatibilityNon-clinical worst-case MRI review performed based on scientific rationale and published literature; addressed magnetic displacement force and torque.
    CAD/CAM System CompatibilityConfirmed compatible with Sirona Dental CAD/CAM System (K193408, K200191) through a business agreement and disclosed requirements.
    Abutment Post Height4.0 mm ~ 16.7 mm
    Angulation0° ~ 20° (over 20° is contraindication at TiBase)
    Wall Thickness0.8 mm ~ 9.5 mm
    Diameter3.3 mm ~ 6.0 mm (dependent on selected TiBase)
    Gingival Height1.0 mm (dependent on selected TiBase)

    2. Sample Size Used for the Test Set and Data Provenance

    The document does not explicitly state a specific "test set" sample size for a clinical study. The performance evaluation relied on non-clinical testing and comparison to predicate devices, referencing international standards and scientific literature.

    • Data Provenance: The document does not specify a country of origin for any data beyond the manufacturer being in Japan. The studies are non-clinical, involving material testing and compatibility assessments. There is no mention of retrospective or prospective data as no human clinical testing was performed.

    3. Number of Experts Used to Establish the Ground Truth for the Test Set and Their Qualifications

    Not applicable. No human clinical testing was performed, and thus no expert ground truth was established for a clinical test set. The ground truth for material properties and performance would be derived from adherence to international standards and non-clinical testing protocols.

    4. Adjudication Method for the Test Set

    Not applicable. As no clinical test set requiring human interpretation or adjudication was used, this information is not relevant.

    5. If a Multi-Reader Multi-Case (MRMC) Comparative Effectiveness Study Was Done, and the Effect Size

    No, a multi-reader multi-case (MRMC) comparative effectiveness study was not done. The document explicitly states: "No human clinical testing was performed to support the substantial equivalence of the subject device."

    6. If a Standalone (Algorithm Only Without Human-in-the-Loop Performance) Was Done

    This device is not an AI algorithm. It is a physical dental material (zirconia block) used in a CAD/CAM system. Therefore, the concept of "standalone (algorithm only)" performance is not applicable. The performance is related to the material's physical and mechanical properties, its compatibility with the CAD/CAM system, and its ability to meet structural requirements when fabricated into an abutment.

    7. The Type of Ground Truth Used

    The ground truth for this device is based on:

    • International Standards: Adherence to established ISO standards for ceramic dental materials (ISO 6872:2015) and dynamic fatigue testing for dental implants (ISO 14801:2016).
    • Material Composition: Verification of identical chemical composition to a previously cleared reference device (KATANA Zirconia Block, K190436).
    • Biocompatibility Standards: Evaluation against ISO 10993 series and ISO 7405.
    • Engineering Design Parameters: Validation against specified design parameters for abutment post height, angulation, wall thickness, diameter, and gingival height, consistent with CAD/CAM system requirements and FDA recommendations.
    • Compatibility: Confirmation of functional compatibility with the predicate CAD/CAM system (Dentsply Sirona) and associated TiBase components through a business agreement and technical specifications.

    8. The Sample Size for the Training Set

    Not applicable. This device is a physical material, not an AI/ML algorithm that requires a "training set."

    9. How the Ground Truth for the Training Set Was Established

    Not applicable, as there is no training set for this type of device.

    Ask a Question

    Ask a specific question about this device

    K Number
    K231039

    Validate with FDA (Live)

    Date Cleared
    2023-12-13

    (245 days)

    Product Code
    Regulation Number
    872.3200
    Panel
    Dental
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    N/A
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use
    • [1] Direct restorations using light-cured composite resin
    • [2] Sealing of a prepared cavity or abutment tooth as a pretreatment for indirect restorations
    • [3] Treatment of exposed root surfaces
    • [4] Treatment of hypersensitive teeth
    • [5] Intraoral repairs of fractured restorations
    • [6] Post cementation and core build-ups
    • [7] Cementation of indirect restorations
    Device Description

    CLEARFIL Universal Bond Quick 2 consists of BOND and K-ETCHANT Syringe. BOND is a light-cure bonding agent that allows for the treatment of dentin, enamel, and prosthetic materials. Depending on the indication, BOND is used as self-etching or with K-ETCHANT Syringe for selective enamel etching or total-etching procedures. BOND is intended to be used for both direct and indirect restorations. CLEARFIL DC Activator activates the dual-curing mechanism of BOND; however, the addition of CLEARFIL DC Activator to the adhesive is not required when using BOND with CLEARFIL DC CORE PLUS, self-adhesive resin cements manufactured by Kuraray Noritake Dental Inc. (Kuraray's self-adhesive cements, e.g. PANAVIA SA Cement Universal) or PANAVIA Veneer LC. K-ETCHANT Syringe is an etching gel that consists of 35 % phosphoric acid aqueous solution and colloidal silica.

    AI/ML Overview

    This document is a 510(k) Premarket Notification from the FDA regarding a dental bonding agent, CLEARFIL Universal Bond Quick 2. It details the device's indications for use, its substantial equivalence to predicate devices, and the testing performed to demonstrate this equivalence.

    Here's an analysis of the acceptance criteria and the study proving the device meets them:

    1. Acceptance Criteria Table and Reported Device Performance:

    SectionRequirementCLEARFIL Universal Bond Quick 2 (Subject Device)CLEARFIL Universal Bond Quick (Primary Predicate Device)BeautiBond Xtreme (Predicate Device)
    AppearanceYellow or orange transparent liquid, No extraneous materialCOMPLIESCOMPLIES(Not tested/reported)
    Ease of applicationEasy to applyCOMPLIESCOMPLIES(Not tested/reported)
    Depth of cureEqual to or greater than 0.5 mmCOMPLIESCOMPLIES(Not tested/reported)
    Shear bond strength to bovine enamelEqual to or greater than 10 MPaCOMPLIESCOMPLIESCOMPLIES
    Shear bond strength to bovine dentinEqual to or greater than 10 MPaCOMPLIESCOMPLIESCOMPLIES
    Tensile bond strength to dental ceramicEqual to or greater than 10 MPaCOMPLIESCOMPLIES(Not tested/reported)
    Tensile bond strength to metalEqual to or greater than 17 MPaCOMPLIESCOMPLIES(Not tested/reported)
    Occlusion dentinal tubulesDentinal tubules are occludedCOMPLIESCOMPLIES(Not tested/reported)
    pH2.4 ± 0.4COMPLIESCOMPLIES(Not tested/reported)

    2. Sample Size and Data Provenance:

    The document does not explicitly state the sample sizes used for the shear/tensile bond strength or fluoride release testing. It states that "certain tests were performed on this device, in comparison with the primary predicate device..." and references "the results of comparative study."

    Regarding data provenance: The applicant, Kuraray Noritake Dental Inc., is based in Japan (1621 Sakazu, Kurashiki, Okayama 710-0801, Japan). The testing appears to be in-house testing performed by the manufacturer to demonstrate substantial equivalence, rather than a large-scale clinical trial with specific regional data. The document mentions "in-house standard" for compliance. The data is retrospective in the sense that it represents a snapshot of the device's performance at the time of submission.

    3. Number of Experts and Qualifications:

    The document does not mention the use of experts to establish ground truth for a test set. This type of submission relies on physical and chemical performance testing against defined quantitative criteria (e.g., bond strength in MPa). There were no human studies (e.g., diagnostic studies) mentioned that would require expert adjudication.

    4. Adjudication Method:

    Not applicable. As described above, this submission focuses on objective laboratory performance metrics, not human-read subjective assessments that would require adjudication.

    5. Multi-Reader Multi-Case (MRMC) Comparative Effectiveness Study:

    No MRMC study was conducted or mentioned. This is a dental bonding agent, not an AI-assisted diagnostic tool. Therefore, there's no concept of human readers improving with AI assistance.

    6. Standalone Algorithm Performance:

    Not applicable. This is a physical and chemical product, not a software algorithm.

    7. Type of Ground Truth Used:

    The "ground truth" for this device's performance evaluation is based on pre-defined quantitative performance metrics and physical/chemical properties established through laboratory testing. For example:

    • Shear/Tensile Bond Strength: Measured values against a minimum acceptable MPa.
    • Depth of Cure: Measured value against a minimum acceptable mm.
    • pH: Measured value within a specified range.
    • Appearance/Ease of Application/Occlusion of Dentinal Tubules: Qualitative assessment against defined criteria (e.g., "COMPLIES").

    These are not "expert consensus," "pathology," or "outcomes data" in the typical sense of a diagnostic or therapeutic clinical study, but rather engineering and material science specifications.

    8. Sample Size for the Training Set:

    Not applicable. This document describes a traditional medical device (dental material) and its performance validation, not a machine learning model that would require a training set.

    9. How Ground Truth for Training Set Was Established:

    Not applicable, as there is no training set for this type of device.

    Ask a Question

    Ask a specific question about this device

    K Number
    K220369

    Validate with FDA (Live)

    Date Cleared
    2022-09-23

    (227 days)

    Product Code
    Regulation Number
    872.6660
    Panel
    Dental
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    N/A
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    Esthetic Colorant is used for coloring pre-sintered zirconia structures for the fabrication of all-ceramic restorations.

    Device Description

    Esthetic Colorant, a colorant with a zirconia structure, is a dilute aqueous solution of transition metal salts and lanthanoid metal salts and enables appropriate color adjustment when combined with a pre-sintered zirconia structure such as KATANA Zirconia (K143439).

    Esthetic Colorant colors the pre-sintered zirconia structure by applying it with a metal-free brush. The structure is then dried and then sintered at temperatures above 1400°C. Sintering welds the coloring components in Esthetic Colorant, making it possible to adjust the color shade of the zirconia structure.

    Esthetic Colorant has 12 shades in bottle size (12 ml). In addition, Esthetic Colorant can only be used by professional technicians in the field of dentistry.

    AI/ML Overview

    Here's a breakdown of the acceptance criteria and study information for the "Esthetic Colorant" device, based on the provided FDA 510(k) summary:

    This document is a 510(k) summary for a medical device that colors pre-sintered zirconia structures for dental restorations. It is not an AI/ML device, and therefore several of the requested sections (sample size for test set, data provenance, number of experts for ground truth, adjudication method, MRMC study, standalone performance, sample size for training set, ground truth for training set) are not applicable.

    1. Table of acceptance criteria and the reported device performance

    Acceptance Criteria (from ISO 6872:2015)Reported Device Performance (Esthetic Colorant with KATANA Zirconia HT)
    Flexural Strength:
    Equal to or greater than 900 MPaCOMPLIES (for all tested colorants)
    Coefficient of Thermal Expansion:
    Shall not deviate by more than 0.5 x 10^-6 K^-1 from manufacturer's stated valueCOMPLIES (for all tested colorants)
    Chemical Solubility:
    Less than to 100 µg/cm²COMPLIES (for all tested colorants)

    2. Sample sized used for the test set and the data provenance

    • Sample Size: Not explicitly stated how many samples were tested for each physical and chemical property, other than that the properties were evaluated according to ISO 6872:2015.
    • Data Provenance: Not explicitly stated, but the company is in Japan (Kuraray Noritake Dental Inc.) so it can be inferred that the testing was conducted there. The testing is prospective as it's for a new product submission.

    3. Number of experts used to establish the ground truth for the test set and the qualifications of those experts

    • Not Applicable. This is a material science device, not an AI/ML device requiring expert ground truth for image interpretation or diagnosis. The ground truth refers to adherence to physical and chemical property standards.

    4. Adjudication method for the test set

    • Not Applicable. See point 3. Testing involves objective measurements against established ISO standards.

    5. If a multi reader multi case (MRMC) comparative effectiveness study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance

    • Not Applicable. This is a material science device, not an AI/ML device.

    6. If a standalone (i.e. algorithm only without human-in-the-loop performance) was done

    • Not Applicable. This is a material science device; there is no algorithm or standalone performance in the context of AI.

    7. The type of ground truth used

    • International Standard Compliance: The ground truth is established by the requirements of the international standard ISO 6872:2015 for dental ceramics. This standard defines the acceptable ranges for physical (flexural strength, coefficient of thermal expansion) and chemical (chemical solubility) properties.

    8. The sample size for the training set

    • Not Applicable. This is not an AI/ML device with a training set.

    9. How the ground truth for the training set was established

    • Not Applicable. See point 8.
    Ask a Question

    Ask a specific question about this device

    K Number
    K213147

    Validate with FDA (Live)

    Device Name
    CERABIEN MiLai
    Date Cleared
    2022-03-28

    (182 days)

    Product Code
    Regulation Number
    872.6660
    Panel
    Dental
    Age Range
    All
    Reference & Predicate Devices
    N/A
    Predicate For
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    For use in prosthetic dentistry to create an all-ceramic prosthesis.

    • Ceramic for coverage of a zirconia substructure
    • Ceramic for coverage of a lithium disilicate substructure [CTE: 10.2-10.5×10-6/K (50-500°C)]
    Device Description

    Not Found

    AI/ML Overview

    The provided text is a 510(k) premarket notification letter from the FDA for a dental prosthetic material, CERABIEN MiLai. It does not contain any information about acceptance criteria for device performance, the study design, or results of any performance studies (e.g., clinical or technical validation studies for an AI/ML powered medical device).

    Therefore, I cannot extract the requested information. The document pertains to the regulatory clearance of a material, not a software or AI device that would have such performance criteria and studies.

    Ask a Question

    Ask a specific question about this device

    K Number
    K210504

    Validate with FDA (Live)

    Date Cleared
    2021-06-11

    (109 days)

    Product Code
    Regulation Number
    872.3275
    Panel
    Dental
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    N/A
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    Cementation of ceramic and composite inlays, onlays and laminate veneers with less than 2mm thickness

    Device Description

    PANAVIA Veneer LC is a light-cure adhesive resin cement system. It consists of the light-cure cement paste (PANAVIA Veneer LC paste), CLEARFIL CERAMIC PRIMER PLUS, K-ETCHANT Syringe, and PANAVIA V5 Try-in Paste. CLEARFIL Universal Bond Quick or PANAVIA V5 Tooth Primer can be chosen for tooth treatment.

    The cement paste is a light-cure, resin based material which provides color stability and has radiopacity equal to or greater than 1mm aluminum. It is indicated for inlays, onlays and laminate veneer restorations made of ceramic and composite resin. It is supplied in Kuraray's ergonomic syringe and dispensed via an angled applicator tip (16G) into an inlay cavity or onto an onlay or a laminate veneer. It is available in 4 shades; Universal (A2), Clear, Brown (A4) and White. It is classified as a Type 2 and Class 2 (Group 1) material by ISO 4049. Shade adaptation is available to check by PANAVIA V5 Try-in Paste before cementation. This is the new registration application for the subject device and there have not been any prior submissions regarding the subject device.

    We are seeking clearance for PANAVIA Veneer LC paste in this submission.

    Concerning Try-in Paste which is included as components of the PANAVIA V5, CLEARFIL Universal Bond Quick, CLEARFIL CERAMIC PRIMER PLUS and K-ETCHANT Syringe, the specification of those 4 components were omitted for the reasons set forth below.

    We already have had 510(k) clearance of Try-in Paste of PANAVIA V5(510(k) Number: 150704), CLEARFIL Universal Bond Quick (510(k) Number: 161042), CLEARFIL CERAMIC PRIMER PLUS (510(k) Number: 150703) and K-ETCHANT Syringe (510(k) Number: 133078).

    AI/ML Overview

    This document describes the marketing authorization for the PANAVIA Veneer LC dental cement. Here's a breakdown of the acceptance criteria and supporting studies:

    1. Table of Acceptance Criteria and Reported Device Performance

    SectionRequirementPANAVIA Veneer LC (Subject device)PANAVIA V5 (Primary predicate device)CLEARFIL MAJESTY ES Flow (Predicate device)
    5.2.2 Film thickness, luting materials< 50 μm.COMPLIESCOMPLIESCOMPLIES
    5.2.7 Sensitivity to ambient lightThe material shall remain physically homogeneous.COMPLIESCOMPLIESCOMPLIES
    5.2.8 Depth of cureShade type 1 and Predicate device: Not less than 1.5mm. Shade type 2: Not less than 1.0mm.COMPLIESCOMPLIESCOMPLIES
    5.2.9 Flexural strengthEqual to or greater than 50 MPa.COMPLIESCOMPLIESCOMPLIES
    5.2.10 Water sorption and solubility≤ 40 μg/mm³.COMPLIESCOMPLIESCOMPLIES
    ≤ 7.5 μg/mm³.COMPLIESCOMPLIESCOMPLIES
    5.4 Color stability after irradiation and water sorptionNo more than a slight change in color shall be observed for luting materials.COMPLIESCOMPLIESCOMPLIES
    5.5 Radio-opacityEqual to or greater than that of the same thickness of aluminium and no less than 0.5 mm of any value claimed by the manufacturer.COMPLIESCOMPLIESCOMPLIES

    Bond Strength Test

    Adherend surface (Material composition)CriteriaSubject devicePrimary predicate device (PANAVIA V5)
    Tooth dentinIn-house standardCOMPLIESCOMPLIES
    Tooth enamelCOMPLIESCOMPLIES
    CeramicCOMPLIESCOMPLIES
    Composite resinCOMPLIESCOMPLIES
    Hybrid ceramicCOMPLIESCOMPLIES

    2. Sample Size Used for the Test Set and Data Provenance

    The document does not explicitly state the specific sample sizes used for each individual test within the comparative study according to ISO 4049: 2009 or the bond strength test. The data provenance is implied to be from internal studies conducted by Kuraray Noritake Dental Inc., as indicated by "In-house standard" for the bond strength criteria. The country of origin of the device manufacturer is Japan. The studies are assumed to be prospective in nature, conducted specifically for the purpose of this 510(k) submission.

    3. Number of Experts Used to Establish the Ground Truth for the Test Set and the Qualifications of Those Experts

    This document does not describe the use of human experts or ground truth establishment in the context of diagnostic interpretation or clinical decision-making. The "ground truth" here refers to objective physical and mechanical properties measured and compared against established ISO standards and in-house standards. Therefore, information regarding experts and their qualifications for establishing ground truth is not applicable to this type of device and study.

    4. Adjudication Method for the Test Set

    Not applicable. The studies involve objective measurements of material properties against predefined standards, not subjective interpretations requiring adjudication.

    5. Multi-Reader Multi-Case (MRMC) Comparative Effectiveness Study

    Not applicable. This device is a dental cement, and its performance is evaluated based on physical and mechanical properties, not by human readers interpreting medical images or data. Therefore, an MRMC study and effect size of AI assistance are not relevant.

    6. Standalone (Algorithm Only Without Human-in-the-Loop Performance) Study

    Not applicable. This device is a dental cement, not an algorithm or AI-powered system. The studies described evaluate the intrinsic properties of the material.

    7. Type of Ground Truth Used

    The ground truth used for the subject device's performance evaluation against acceptance criteria is based on:

    • International Standards: Specifically, ISO 4049: 2009 (Dentistry - Polymer-based restorative and materials).
    • In-house Standards: For the bond strength test.
    • Comparative Data: Performance of the predicate devices (PANAVIA V5 and CLEARFIL MAJESTY ES Flow) serve as a comparative ground truth to demonstrate substantial equivalence.

    8. Sample Size for the Training Set

    Not applicable. This device is a dental cement, not a machine learning model. Therefore, there is no "training set" in the context of artificial intelligence.

    9. How the Ground Truth for the Training Set Was Established

    Not applicable, as there is no training set for this type of device.

    Ask a Question

    Ask a specific question about this device

    K Number
    K193060

    Validate with FDA (Live)

    Date Cleared
    2020-01-30

    (90 days)

    Product Code
    Regulation Number
    872.6660
    Panel
    Dental
    Age Range
    All
    Reference & Predicate Devices
    N/A
    Predicate For
    N/A
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    For use in prosthetic dentistry to create a Porcelain prosthesis on a frame of dental alloy.

    Device Description

    Not Found

    AI/ML Overview

    The provided text is a 510(k) clearance letter from the FDA for a dental porcelain product. It does not contain any information about acceptance criteria, device performance testing, sample sizes, expert qualifications, or study methodologies that would be required to answer your request.

    Specifically, it lacks the following:

    1. A table of acceptance criteria and reported device performance: This document only states the device "Noritake Super Porcelain EX-3" is cleared for "For use in prosthetic dentistry to create a Porcelain prosthesis on a frame of dental alloy." There are no performance metrics or criteria listed.
    2. Sample sizes, data provenance, number of experts, adjudication methods, MRMC studies, standalone performance, type of ground truth, training set size, or how training ground truth was established. The letter is a regulatory approval, not a scientific study report.

    Therefore,Based on the provided text, I cannot describe the acceptance criteria and the study that proves the device meets the acceptance criteria as the document is a regulatory approval letter and does not contain the detailed study information you are asking for.

    Ask a Question

    Ask a specific question about this device

    K Number
    K191980

    Validate with FDA (Live)

    Date Cleared
    2019-11-18

    (117 days)

    Product Code
    Regulation Number
    872.3690
    Panel
    Dental
    Age Range
    All
    Reference & Predicate Devices
    N/A
    Predicate For
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    CLEARFIL MAJESTY ES Flow is indicated for the following restorative applications:

    • [1] Direct restorations for all cavity classes, cervical lesions (e.g. root surface caries, v-shape defects), tooth wear, and tooth erosion
    • [2] Cavity base / liner
    • [3] Correction of tooth position and tooth shape (e.g. diastema closure, tooth malformation)
    • [4] Intraoral repair of fractured restorations
    • [5] Cementation of ceramic and composite inlays, onlays and veneers with less than 2mm thickness
    Device Description

    Not Found

    AI/ML Overview

    The provided text is a 510(k) clearance letter from the FDA for a dental restorative material called CLEARFIL MAJESTY ES Flow. It details the device's indications for use and regulatory classification. However, this document does not contain any information regarding acceptance criteria, device performance studies, sample sizes, ground truth establishment, expert qualifications, or MRMC studies.

    Therefore, I cannot provide the requested information based on the given input text. The information typically found in a 510(k) clearance letter focuses on regulatory approval based on substantial equivalence to predicate devices, rather than detailed performance study results and acceptance criteria. Such detailed study information would usually be found in the 510(k) submission itself or in published studies related to the device.

    Ask a Question

    Ask a specific question about this device

    K Number
    K191133

    Validate with FDA (Live)

    Date Cleared
    2019-10-08

    (162 days)

    Product Code
    Regulation Number
    872.3260
    Panel
    Dental
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    N/A
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use
    • [1] Cleaning of contaminated glass ceramic, zirconia, resin restorations, metal restorations and fiber post after intraoral try-in.
    • [2] Cleaning for contaminated prepared tooth (cavity, root canal and tooth abutment), and implant abutment
    Device Description

    This subject device is a dental cleaning agent suitable for non-abrasive cleaning of the bonding surfaces of prosthetic restorations after intraoral try-in.

    It is also suitable for cleaning a contaminated prepared cavity, root canal, and tooth/ implant abutment. It is used in helping to achieve optimal adhesive results.

    AI/ML Overview

    The provided text describes the regulatory clearance of a dental cleaning agent, KATANA Cleaner, by the FDA. It includes a 510(k) summary which details the device, its intended use, comparison to predicate and reference devices, and non-clinical performance testing.

    Here's the breakdown of the acceptance criteria and the study proving the device meets them, based on the provided text:

    1. Table of acceptance criteria and the reported device performance:

    Evaluation ItemCriteriaSubject Device (KATANA Cleaner) PerformancePredicate device (CONSEPSIS) PerformanceReference device (ZirClean) Performance
    AppearanceIn-house standardCOMPLIESCOMPLIESCOMPLIES
    Coating propertyIn-house standardCOMPLIESCOMPLIESCOMPLIES
    Shear bond strength (contaminated by artificial saliva)
    - Bovine DentinIn-house standardCOMPLIESCOMPLIESN/A (not tested for ZirClean)
    - Metal (Titan100)In-house standardCOMPLIESCOMPLIESCOMPLIES
    - Ceramics (KATANA Zirconia HT)In-house standardCOMPLIESCOMPLIESCOMPLIES
    pH (before rinse/ after rinse)In-house StandardCOMPLIESCOMPLIESCOMPLIES
    Water solubilityIn-house StandardCOMPLIESCOMPLIESCOMPLIES
    SEM and EDX Surface ComparisonIn-house StandardCOMPLIESCOMPLIESCOMPLIES
    Staining Test(Not explicitly stated, but confirms color)Colored (Purple)Colored (Blue)Colored (Blue)

    Summary of Device Performance against Criteria:

    • Appearance and Coating Property: The device met in-house standards, showing no difference from predicate and reference devices.
    • Shear Bond Strength: The device demonstrated "good performance as cleaning agent," with shear bond strengths "equal to or greater than those of the predicate device and the reference device" after contamination with artificial saliva. Specifically, for "Just after prepared" and "for 3 weeks at 70 ℃/ 158 °F," the shear bond strength was equal to the "Positive control (Without contamination and applying the subject device)" and higher than the "Negative control (without the subject device)."
    • pH (before rinse/after rinse): The pH value of the subject device was within the range of the predicate and reference devices and became neutral after rinsing, similar to the control.
    • Water Solubility: The device was easily removed from the substrate, indicating good water solubility.
    • SEM and EDX Surface Comparison: The peak area ratio of the subject device was the same as the control, predicate, and reference devices.
    • Staining Test: The device was confirmed to be colored (purple), similar to the predicate and reference devices.

    2. Sample size used for the test set and the data provenance (e.g. country of origin of the data, retrospective or prospective):

    • Sample Size: Not explicitly stated in the provided text for the individual bench tests. The text only mentions "Shear bond strength tests to the adherent surfaces were performed on this device..." and does not give the number of samples per test.
    • Data Provenance: The studies were performance bench tests ("Non-Clinical Performance Testing"). There is no mention of country of origin of the data or whether it was retrospective or prospective, as these are in vitro laboratory tests. The submitter, Kuraray Noritake Dental Inc., is based in Japan.

    3. Number of experts used to establish the ground truth for the test set and the qualifications of those experts:

    • This information is not applicable as the evaluation involved non-clinical bench testing (material science / engineering properties) rather than human reader interpretation of medical images or clinical data. "Ground truth" in this context refers to the measured physical and chemical properties, not expert consensus.

    4. Adjudication method (e.g. 2+1, 3+1, none) for the test set:

    • This information is not applicable as the evaluation involved non-clinical bench testing and not human interpretation or adjudication.

    5. If a multi reader multi case (MRMC) comparative effectiveness study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance:

    • This information is not applicable. This submission is for a dental cleaning agent, not an AI-powered diagnostic or assistive tool. Therefore, an MRMC study or evaluation of human reader improvement with AI assistance was not performed.

    6. If a standalone (i.e. algorithm only without human-in-the loop performance) was done:

    • This information is not applicable. This is a physical dental cleaning agent, not an algorithm.

    7. The type of ground truth used (expert concensus, pathology, outcomes data, etc):

    • The "ground truth" for the non-clinical performance tests was established through measured physical and chemical properties, comparative analysis against controls (positive and negative), and comparison to predicate and reference devices. This includes:
      • Direct measurements of shear bond strength.
      • Visual inspection for appearance and coating property.
      • pH measurements.
      • Observation of water solubility.
      • Analytical techniques like Scanning Electron Microscopy (SEM) and Energy-Dispersive X-ray Spectroscopy (EDX) for surface comparison.
      • Biocompatibility testing according to ISO standards.

    8. The sample size for the training set:

    • This information is not applicable. This is a physical medical device, not a machine learning model; therefore, there is no "training set."

    9. How the ground truth for the training set was established:

    • This information is not applicable as there is no training set for this type of device submission.
    Ask a Question

    Ask a specific question about this device

    K Number
    K190436

    Validate with FDA (Live)

    Date Cleared
    2019-05-23

    (90 days)

    Product Code
    Regulation Number
    872.6660
    Panel
    Dental
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    KATANA Zirconia Block is used for the fabrication of the ceramic restorations (frameworks, FCZ crowns, FCZ bridges (14Z L only), inlays, onlays and veneers).

    Device Description

    The subject device, KATANA Zirconia Block is a pre-sintered zirconia block composed of yttrium stabilized zirconia, which is designed for CEREC milling systems. The subject device is meant to be end-user sintered after milling for the fabrication of dental restorations. KATANA Zirconia Block STML has 3 sizes (12Z, 14Z and 14Z L) and has 14 shade variations: (A1, A2, A3, A3.5, A4, B1, B2, B3, C1, C2, C3, D2, D3, NW). KATANA Zirconia Block ST has 1 size: (12Z) and has 1 shade variation: (CL). STML consists of 4 gradated shade layers and ST is mono color. They are classified as a Type II and Class 4a) material by ISO 6872.

    AI/ML Overview

    This document describes the premarket notification for the KATANA Zirconia Block and demonstrates its substantial equivalence to previously cleared predicate and reference devices.

    Here's an analysis of the provided text regarding acceptance criteria and the study that proves the device meets them:

    1. A table of acceptance criteria and the reported device performance

    The document provides a table (Table 3-6-3) comparing the subject device (KATANA Zirconia Block (14Z L)), the predicate device (KATANA Zirconia Block (12Z, 14Z)), and the reference device (KATANA Zirconia Disc (ST, STML)) against requirements specified in ISO 6872:2015 (Dentistry — Ceramic materials — Part 1: Dental ceramics).

    Acceptance Criteria (from ISO 6872:2015)RequirementReported Device Performance (Subject Device: KATANA Zirconia Block (14Z L))
    Uniformity (5.1)The inorganic pigment(s) used to produce the color of a fired dental ceramic and any organic colorants (for color coding) shall be uniformly dispersed... Check by visual inspection.COMPLIES
    Freedom from extraneous materials (5.2.1)Dental ceramic materials shall be free from extraneous materials when assessed by visual inspection.COMPLIES
    Freedom from extraneous materials (5.2.2)Dental ceramic materials shall not have an activity concentration of more than 1.0 Bq·g-1 of 238U. Test in accordance with 7.2.2.COMPLIES
    Flexural strength (5.4)Equal to or greater than 500 MPa.COMPLIES
    Chemical solubility (5.4)Less than 100 µg/cm².COMPLIES
    Coefficient of thermal expansion (5.4)The coefficient of thermal expansion of the ceramics shall not deviate by more than 0.5 × 10-6 K-1 from the value stated by the manufacturer. (The value stated by the manufacturer: 9.8 × 10-6 K-1)COMPLIES

    "COMPLIES" indicates that the test value was within the acceptable range to pass the testing in compliance with the requirements of ISO 6872:2015.

    2. Sample sized used for the test set and the data provenance (e.g. country of origin of the data, retrospective or prospective)

    The document does not explicitly state the sample sizes used for the bench testing. It refers to a "comparative study performed according to ISO 6872:2015," which typically involves specific sample sizes dictated by the standard for each test. The data provenance (country of origin, retrospective/prospective) is not mentioned. However, the applicant is "Kuraray Noritake Dental Inc." in Japan, suggesting the testing was likely conducted by or for this Japanese company.

    3. Number of experts used to establish the ground truth for the test set and the qualifications of those experts (e.g. radiologist with 10 years of experience)

    This is a physical/mechanical properties test for a dental ceramic block, not a diagnostic medical device that requires expert interpretation. Therefore, there are no "experts" in the sense of medical professionals establishing a ground truth based on clinical evaluation. The ground truth for these tests is established by adhering to the standards and methods outlined in ISO 6872:2015. Visual inspections (e.g., for uniformity, absence of extraneous materials) would be performed by trained technicians or quality control personnel.

    4. Adjudication method (e.g. 2+1, 3+1, none) for the test set

    Since this is a bench testing scenario focusing on physical and chemical properties against a standard, an adjudication method for conflicting expert opinions (like 2+1 or 3+1) is not applicable. The compliance is determined by instrumental measurements and visual inspections against quantitative and qualitative criteria defined by ISO 6872:2015.

    5. If a multi reader multi case (MRMC) comparative effectiveness study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance

    No MRMC comparative effectiveness study was performed. This device is a dental material (zirconia block) and not an AI-powered diagnostic tool requiring human reader assistance.

    6. If a standalone (i.e. algorithm only without human-in-the-loop performance) was done

    This is not an algorithm-based device. It is a physical dental material. Therefore, no standalone algorithm performance study was done. The performance evaluation is based on standard material testing methods.

    7. The type of ground truth used (expert consensus, pathology, outcomes data, etc.)

    The ground truth for this device's performance evaluation is established by international standards (ISO 6872:2015). The performance is measured against the pre-defined limits and specifications within this standard, rather than expert consensus on clinical cases, pathology, or outcomes data.

    8. The sample size for the training set

    This is not an AI/machine learning device; therefore, there is no "training set" in the computational sense. The material is manufactured and tested according to quality control procedures to meet the specified standards.

    9. How the ground truth for the training set was established

    As there is no training set for an algorithm, this question is not applicable.

    Ask a Question

    Ask a specific question about this device

    Page 1 of 3