510(k) Data Aggregation

    K Number
    K073214

    Validate with FDA (Live)

    Manufacturer
    Date Cleared
    2009-12-01

    (748 days)

    Product Code
    Regulation Number
    888.3045
    Age Range
    All
    Reference & Predicate Devices
    N/A
    Predicate For
    N/A
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    When used with appropriate opening osteotomy system devices, plates and screws, Duowedge is intended to be used as a bone void filler in tibial osteotomies. Duowedge is to be used in combination with adequate post-operative immobilization.

    Device Description

    The calcium phosphate ceramic Duowedge manufactured by KASIOS is designed to be used as a bone void filler tibial osteotomies. Duowedge is a synthetic bone substitute. It is a macroporous bioceramic, made of hydroxyapatite and beta tricalcium prosphate. When . it is nony site, Duowedge gradually and partially resorbs and is replaced with bone during the healing process. In addition, Duowedge is intended to be used with appropriate opening osteotomy system devices, plates and screws. Duowedge is for use in combination with adequated postoperative immobilization.

    AI/ML Overview

    The provided text is a 510(k) summary for the Duowedge device by Kasios. It describes the device, its intended use, and its substantial equivalence to previously cleared bone substitutes. However, it does not contain any information about acceptance criteria, device performance, sample sizes for test or training sets, expert qualifications, adjudication methods, MRMC studies, or standalone algorithm performance. The document is a regulatory submission for a bone substitute, not an AI/ML medical device.

    Therefore, I cannot fulfill your request for information regarding acceptance criteria and study details based on the provided text. The document primarily focuses on demonstrating substantial equivalence to predicate devices based on indications for use, materials, and design, rather than quantitative performance metrics from a clinical study for a new AI/ML product.

    Ask a Question

    Ask a specific question about this device

    K Number
    K042340

    Validate with FDA (Live)

    Device Name
    KASIOS TCP
    Date Cleared
    2004-11-24

    (86 days)

    Product Code
    Regulation Number
    888.3045
    Age Range
    40 - 65
    Reference & Predicate Devices
    N/A
    Predicate For
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    Kasios TCP is indicated only for filling bone voids or defects that are not intrinsic to the stability of the bony structure. Kasios TCP is to be gently packed into bony voids or gaps of the skeletal system (such as the extremities, spine and the pelvis). These defects may be surgically created osseous defects or osseous defects created from traumatic injury to the bone. Kasios TCP is a bone graft substitute that resorbs and is replaced with bone during the healing process.

    Device Description

    The KASIOS TCP is a synthetic resorbable calcium phosphate bone void filler. It is an osteoconductive material which provides a porous scaffold upon which bone formation can occur. The interconnected porosity ranges from 60 to 80% with a pore size range of 200 to 500um. The device is available in a variety of shapes and sizes.

    AI/ML Overview

    This submission is a 510(k) premarket notification for a medical device called "Kasios TCP," a synthetic resorbable calcium phosphate bone void filler. The purpose of a 510(k) is to demonstrate that the device is substantially equivalent to legally marketed predicate devices, not to establish new performance criteria through clinical trials or specialized studies that define acceptance criteria or measure performance against them.

    Therefore, the provided text does not contain information on:

    • Acceptance Criteria and Reported Device Performance: There is no table of acceptance criteria or reported device performance metrics. The submission focuses on demonstrating substantial equivalence to predicate devices, not on proving specific performance targets.
    • Study Details: There are no details on sample sizes, data provenance, number or qualifications of experts for ground truth, adjudication methods, multi-reader multi-case (MRMC) comparative effectiveness studies, or standalone algorithm performance studies. These types of studies are typically found in PMAs (Premarket Approval applications) or sometimes in more extensive clinical studies supporting 510(k)s that address specific performance aspects, but they are not present here.
    • Ground Truth: The type of ground truth used, how it was established for training sets, or the sample size for training sets are not mentioned.

    In summary, the provided document is a 510(k) summary demonstrating substantial equivalence, not a study report detailing acceptance criteria and performance data.