510(k) Data Aggregation

    K Number
    K202905

    Validate with FDA (Live)

    Date Cleared
    2021-03-26

    (178 days)

    Product Code
    Regulation Number
    878.4040
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The Disposable Face Mask is intended to be worn to protect both the patient and healthcare personnel from transfer of microorganisms, body fluids, and particulate material. These face masks are intended for use in infection control practices to reduce the potential exposure to blood and body fluids. This is a single-use, disposable device, provided non-sterile.

    Device Description

    The proposed device, Disposable Face Mask is a three-layer, single-use, flat-pleated mask. The ear loops to secure the mask over the users' mouth and face and includes a nosepiece to provide a firm fit over the nose. The disposable surgical mask is available in four different specifications: 14.5cmx9.5cm and 17.5cmx9.5cm. The device is single use and provided non-sterile.

    AI/ML Overview

    The provided text describes the 510(k) submission for a Disposable Face Mask (K202905) and its equivalence to a predicate device (K160269). However, it does not contain information related to an AI/ML-enabled medical device or a clinical study involving human readers and AI assistance.

    Therefore, I cannot provide the requested information regarding acceptance criteria, study details, sample sizes, ground truth establishment, expert qualifications, adjudication methods, or MRMC studies for an AI device. The document is strictly about the non-clinical testing and comparison of a traditional medical device (face mask) to a predicate device to demonstrate substantial equivalence.

    The document covers:

    • Device: Disposable Face Mask
    • Purpose: To protect against transfer of microorganisms, body fluids, and particulate material.
    • Regulatory Class: Class II, Product Code FXX.
    • Acceptance Criteria/Performance (based on standards for face masks):
      • Fluid Resistance (ASTM F1862)
      • Particulate Filtration Efficiency (ASTM F2299)
      • Bacterial Filtration Efficiency (ASTM F2101)
      • Differential Pressure (EN 14683)
      • Flammability (16 CFR 1610)
      • Biocompatibility (ISO 10993-5 and ISO 10993-10)

    Here's a breakdown of what can be extracted from the document, tailored as much as possible to your request, but highlighting the absence of AI/ML specifics:

    1. Table of Acceptance Criteria and Reported Device Performance

    CriterionAcceptance Criteria (Predicate)Reported Device Performance (Proposed Device K202905)Remark
    Fluid Resistance (ASTM F1862)Level 1 Pass at 80mmHg; Level 2 Pass at 120mmHgLevel 1 Pass at 80mmHg; Level 2 Pass at 120mmHgIdentical
    Particulate Efficiency (ASTM F2299)Pass at 99.6% (implied for Level 1 & 2 for predicate)$\ge 95%$ (Level 1), $\ge 98%$ (Level 2)Similar (Meets Level 2 requirements)
    Bacterial Filtration Efficiency (ASTM F2101)Pass at >98% (implied for Level 1 & 2 for predicate)$\ge 95%$ (Level 1), $\ge 98%$ (Level 2)Similar (Meets Level 2 requirements)
    Differential Pressure (EN 14683)Passed at 2.0 mmH2O/cm² (predicate's Level 1), Passed at 1.6 mmH2O/cm² (predicate's Level 2)$<$ 5.0mm H2O/cm² (Level 1), $<$ 6.0mm H2O/cm² (Level 2)Similar (Meets Level 2 requirements)
    Flammability (16 CFR 1610)Class 1Class 1Identical
    Biocompatibility (Cytotoxicity - ISO 10993-5)No CytotoxicityNo CytotoxicityIdentical
    Biocompatibility (Sensitization - ISO 10993-10)No SensitizationNo SensitizationIdentical
    Biocompatibility (Irritation - ISO 10993-10)No IrritationNo IrritationIdentical

    Note: The 'acceptance criteria' are implicitly derived from the performance of the predicate device and the relevant ASTM/EN standards for medical face masks. The proposed device had to meet or exceed these to demonstrate substantial equivalence.

    Regarding AI/ML specific information (which is not in the document):

    1. Sample size used for the test set and data provenance: Not applicable to this device type or study.
    2. Number of experts used to establish the ground truth and qualifications: Not applicable. Ground truth for a face mask's performance is established through standardized laboratory testing (e.g., measuring filtration efficiency, fluid resistance) against predefined physical criteria, not expert interpretation of AI outputs.
    3. Adjudication method: Not applicable.
    4. Multi-reader multi-case (MRMC) comparative effectiveness study: No, this was not done as it's not an AI-enabled device requiring human-in-the-loop assessment.
    5. Standalone (algorithm only) performance: Not applicable.
    6. Type of ground truth: (expert consensus, pathology, outcomes data, etc.): Ground truth for this device is based on physical and biological laboratory measurements according to established international standards (ASTM, EN, ISO).
    7. Sample size for the training set: Not applicable, as this is not an AI/ML device that requires a training set.
    8. How the ground truth for the training set was established: Not applicable.

    In summary, the provided document details the regulatory clearance of a disposable face mask, focusing on non-clinical performance testing against established standards and comparison to a predicate device, not on the performance of an AI/ML system.

    Ask a Question

    Ask a specific question about this device

    K Number
    K201324

    Validate with FDA (Live)

    Date Cleared
    2021-02-05

    (263 days)

    Product Code
    Regulation Number
    N/A
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    N/A
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    Antibacterial bandage is to be applied topically to the skin for management of minor scrapes and minor burns.
    Antibacterial bandage is to be applied topically to the skin for management of minor cuts, minor scrapes and minor burns.

    Device Description

    The device, Antibacterial bandage, is to be applied topically to the skin for management of minor cuts, minor scrapes and minor burns. The proposed devices are available in fabric backing and plastic backing. All of devices consist of (1) backing (fabric or plastic), (2) absorbent pad (composed of Polyester fiber, viscose fiber, PE mesh, Benzalkonium chloride) and (3) release paper (composed of cellulose pulp, water, kaolin, starch, ethanol and ethylene copolymer). Each device type is available in several models. The difference between each model is the device size. This dressing contains 0.08% benzalkonium chloride which has shown effectiveness against (Staphylococcus Aureus, Pseudomonas Aeruginosa, Escherlchia coli, Enterococcus Faecalis, Klebsiella Pneumoniae, Streptococcus Pyogenes, Candida Albicans and Aspergillus Niger) for up to 24 hours, as demonstrated via in vitro testing.

    AI/ML Overview

    The provided text describes the 510(k) summary for an "Antibacterial Bandage" (K201324) and compares it to a predicate device (K113583). It outlines non-clinical tests performed to demonstrate substantial equivalence, but it does not include a multi-reader multi-case (MRMC) comparative effectiveness study, standalone algorithm performance, or details on ground truth for AI model training/testing, as it is not an AI/ML device.

    Here's an analysis of the available information:

    1. Table of Acceptance Criteria and Reported Device Performance

    Test/Acceptance CriteriaReported Device Performance
    Peel Adhesion (per ASTM D3330/D3330M)Peel strength > 1.0 N/cm
    Antimicrobial Efficacy (per AATCC-100)Meets the requirement of 4 log reduction (effective against Staphylococcus Aureus, Pseudomonas Aeruginosa, Escherlchia coli, Enterococcus Faecalis, Klebsiella Pneumoniae, Streptococcus Pyogenes, Candida Albicans, and Aspergillus Niger for up to 24 hours).
    Sterile Barrier Packaging (Seal strength per ASTM F88/F88-15)Device package can maintain its integrity.
    EO ECH Residue (per ISO 10993-7:2008)Did not exceed the limit.
    Bacteria Endotoxin Limit (per USP 42-NF 37 <85>)Did not exceed 20 EU/device.
    Shelf Life EvaluationMaintain its performance during the claimed shelf life (verified by Peel Adhesion, Package Tests on aging samples).
    Biocompatibility (for breached/compromised surfaces, <24 hours contact)Biocompatible (passed Cytotoxicity, Sensitization, Intracutaneous reactivity, Systemic Toxicity, Material-mediated Pyrogenicity tests).
    Sterility Assurance Level (SAL)10^-6

    2. Sample size used for the test set and the data provenance
    The document does not specify the sample sizes for any of the non-clinical tests (e.g., how many bandages were tested for peel adhesion, antimicrobial efficacy, etc.). All tests are described as in vitro (antimicrobial efficacy) or laboratory tests, and there is no mention of human data or data provenance like country of origin.

    3. Number of experts used to establish the ground truth for the test set and the qualifications of those experts
    This information is not applicable as the device is an antibacterial bandage, not an AI/ML diagnostic or prognostic tool. "Ground truth" in the context of expert consensus is not relevant here. The ground truth for the product performance is based on established laboratory standards and test methods.

    4. Adjudication method for the test set
    Not applicable, as this is related to expert consensus for diagnostic/prognostic ground truth, not the testing of a medical device like an antibacterial bandage.

    5. If a multi reader multi case (MRMC) comparative effectiveness study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance
    Not applicable. This is not an AI-assisted device.

    6. If a standalone (i.e., algorithm only without human-in-the-loop performance) was done
    Not applicable. This is not an AI/ML device.

    7. The type of ground truth used
    For the performance tests, the "ground truth" is defined by the requirements of the specified international and national standards (e.g., ASTM, AATCC, ISO, USP). For instance, for antimicrobial efficacy, the ground truth is a "4 log reduction" according to AATCC-100. For peel adhesion, it's >1.0 N/cm as per ASTM D3330/D3330M.

    8. The sample size for the training set
    Not applicable. This is not an AI/ML device, so there is no training set for an algorithm.

    9. How the ground truth for the training set was established
    Not applicable. There is no training set for an AI/ML algorithm.