510(k) Data Aggregation

    K Number
    K130231

    Validate with FDA (Live)

    Date Cleared
    2013-10-15

    (259 days)

    Product Code
    Regulation Number
    880.2910
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    N/A
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    JXB182 Non-contact Infrared Thermometer is an infrared thermometer intended to measure forehead temperature of infants and adults without contacting human body. It can be used by consumers in household environment and doctor in clinic as reference.

    Device Description

    All objects, solid, liquid or gas, emit energy by radiation. The intensity of this energy depends on the temperature of the object. The JXB-182 infrared thermometer is therefore able to measure the temperature of a person by the energy the person emits. This measurement can be taken thanks to an external temperature probe on the device which permanently analyses and registers the ambient temperature. Therefore, as soon as the operator holds the thermometer near the forehead and activates the radiation sensor, the measurement is taken instantly by detection of the infrared heat generated by the arterial blood flow. Body heat can therefore be measured without any interference from the heat of the surrounding environment. The JXB-182 thermometer without contact has been developed using latest infrared technology . This technology allows temporal artery (TA) temperature to be taken at a distance of about 5cm away from the forehead. Then the result will be displayed on LCD. Besides, it owns Led backlight which can show three different colors in different temperature ranges and three-language prompt function.

    AI/ML Overview

    The provided text describes the JXB-182 Non-contact Infrared Thermometer and its substantial equivalence to a predicate device.

    Here's the breakdown of the acceptance criteria and the study that proves the device meets them:

    1. Table of Acceptance Criteria and Reported Device Performance

    Item / CriteriaAcceptance Criteria (Predicate)Reported Device Performance (JXB-182)
    Measurement MethodInfrared Radiation DetectionInfrared Radiation Detection
    Range (Body Mode)32-42.9° C32-42.9° C
    Accuracy± 0.3°C± 0.3°C
    Precision± 0.3°C (34-35.9° C), ±0.2°C (36-39°C), ±0.3°C (39-42.5°C)± 0.3°C (34-35.9° C), ±0.2°C (36-39°C), ±0.3°C (39-42.5°C)
    Power SupplyDC 3V (2AA Batteries)DC 3V (2AA Batteries)
    MaterialABSABS
    Operating Condition (Temperature)10° C to 40° C10° C to 40° C
    DisplayLCDLCD
    Display Resolution0.1° C0.1° C
    Measurement Distance5cm-8cm3cm~5cm
    Operating Condition (Humidity rate)≤ 85%≤ 95%

    2. Sample Size for the Test Set and Data Provenance

    The document states: "Subject device JXB 182 is compliant to the ASTM E 1965-98(Reapproved 2009), Standard Specification for Infrared Thermometers for Intermittent Determination of Patient Temperature. All the relevant activities were performed by designate individual(s) and the results demonstrated that the predetermined acceptance criteria were fully met."

    However, it does not specify the sample size used for the clinical tests nor the data provenance (e.g., country of origin, retrospective or prospective nature of the study).

    3. Number of Experts Used to Establish Ground Truth for the Test Set and Qualifications of those Experts

    The document does not provide information on the number of experts used or their qualifications for establishing ground truth in the clinical tests. It only mentions that activities were performed by "designate individual(s)."

    4. Adjudication Method for the Test Set

    The document does not specify an adjudication method (e.g., 2+1, 3+1, none) for the test set.

    5. If a multi reader multi case (MRMC) comparative effectiveness study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance

    There is no mention of a multi-reader multi-case (MRMC) comparative effectiveness study. This device is a standalone infrared thermometer, not an AI-assisted diagnostic tool that would involve human readers. Therefore, there's no information on humans improving with AI assistance.

    6. If a standalone (i.e. algorithm only without human-in-the-loop performance) was done

    Yes, a standalone performance evaluation was conducted. The clinical tests were performed to ensure the device itself met the performance criteria outlined in ASTM E 1965-98. The device's performance characteristics (accuracy, precision, range) are reported for the device operating independently.

    7. The type of ground truth used (expert consensus, pathology, outcomes data, etc.)

    The type of ground truth used for the clinical tests is implied to be reference temperature measurements, as per the industry standard ASTM E 1965-98, which sets specifications for infrared thermometers. This standard typically involves comparing the device's measurements to a highly accurate reference thermometer.

    8. The sample size for the training set

    The document does not provide information on a training set size. As this is a medical device, and not explicitly an AI/ML product developed with distinct training and test sets in the typical AI sense, the concept of a "training set" for the device's core functionality (temperature measurement) is not outlined. Performance is validated against established standards.

    9. How the ground truth for the training set was established

    Since no specific "training set" is mentioned in the context of AI/ML development, how its ground truth would be established is not applicable or described in this document. The device's design and engineering would have been developed against known thermodynamic principles and calibrated using established standards.

    Ask a Question

    Ask a specific question about this device

    K Number
    K130232

    Validate with FDA (Live)

    Date Cleared
    2013-09-17

    (231 days)

    Product Code
    Regulation Number
    870.1130
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    N/A
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    BPA-002 Electronic Blood Pressure Monitor for Upper Arm is intended to measure systolic and diastolic blood pressures as well as the determination of heart rate by using the oscillometric method. All values can be read out in one LCD panel. It is suitable for adult arm circumference and can be used by medical departments or for home use. However, it shouldn't be used by people who have severe arrhythmia.

    Device Description

    BPA-002 Electronic Blood Pressure Monitor for Upper Arm uses an inflatable cuff which is wrapped around the patient's upper arm. The cuff is inflated automatically by an internal pump in the device. The systolic and diastolic blood pressures are determined by oscillometric method and silicon integrate pressure sensor technology. The deflation rate is controlled by a preset mechanical valve at a constant rate. The pressure of the cuff is completely released automatically at the end of measurement. At the same time, the measurements are displayed on the LCD display for 60 seconds. There is a maximum pressure safety setting at 280mmHg. The device will not inflate the cuff higher than 280mmHg. It will display an irregular heartbeat symbol if an irregular heartbeat was detected during the measurement process. In addition, it has LCD backlight. After 60 seconds without operation, the blood pressure monitors turn off automatically

    AI/ML Overview

    The provided text describes the Jinxinbao Electronic Co., Ltd, Electronic Blood Pressure Monitor for Upper Arm, Model BPA-002. Here's a breakdown of the acceptance criteria and the study information based on the provided text:

    Acceptance Criteria and Device Performance

    CriteriaAcceptance Criteria (from Accuracy row of the comparison table)Reported Device Performance (from Accuracy row of the comparison table)
    Pressure Accuracy±3mmHgPressure: ±3mmHg
    Pulse Accuracy≤5%Pulse: ±5%

    Study Information

    The device BPA-002 is stated to be compliant with the SP10:2002/(R) 2008 & ANSI/AAMI SP10:2002/A1:2003/ (Manual, electronic or automated sphygmomanometers) standard for clinical testing. This standard outlines the requirements for validation of automated sphygmomanometers.

    1. Sample size used for the test set and the data provenance:
      The document does not specify the exact sample size or the data provenance (e.g., country of origin, retrospective or prospective) for the clinical tests mentioned under "SP10:2002/(R) 2008 & ANSI/AAMI SP10:2002/A1:2003/". The AAMI SP10 standard generally requires a specific number of subjects (e.g., 85 subjects with specific blood pressure ranges) for validation, but these details are not provided in this submission summary.

    2. Number of experts used to establish the ground truth for the test set and the qualifications of those experts:
      The document does not explicitly state the number or qualifications of experts used to establish ground truth. For AAMI SP10 compliance, ground truth is typically established by trained human observers using auscultatory methods, but the specifics are not detailed here.

    3. Adjudication method for the test set:
      The document does not describe the adjudication method used for the test set. For AAMI SP10 compliance, a specific protocol for comparing automated readings against human observers' readings (often involving multiple observers for auscultatory ground truth) is followed.

    4. If a multi-reader multi-case (MRMC) comparative effectiveness study was done, if so, what was the effect size of how much human readers improve with AI vs without AI assistance:
      This device is a blood pressure monitor, not an AI-assisted diagnostic tool. Therefore, an MRMC comparative effectiveness study involving human readers and AI assistance is not applicable and was not performed.

    5. If a standalone (i.e. algorithm only without human-in-the-loop performance) was done:
      The clinical test mentioned, "SP10:2002/(R) 2008&ANSI/AAMI SP10:2002/A1:2003/", specifically assesses the standalone performance of the automated blood pressure monitor without human intervention in the measurement process, beyond initial cuff placement. The device's algorithm performs the measurement and displays the result.

    6. The type of ground truth used (expert consensus, pathology, outcomes data, etc.):
      For blood pressure monitors validated against the AAMI SP10 standard, the ground truth for blood pressure measurements is typically established by trained human observers using auscultatory methods (e.g., stethoscope and manometer), often with a double-blinded or an agreed-upon protocol between multiple observers (expert consensus for the auscultatory readings).

    7. The sample size for the training set:
      This document describes evaluation of a medical device, not a machine learning algorithm that requires a "training set" in the traditional sense. The device is based on oscillometric technology and validated against established standards.

    8. How the ground truth for the training set was established:
      As there is no "training set" in the context of a machine learning algorithm as per the question, this is not applicable. The device's underlying principles are based on established oscillometric blood pressure measurement techniques rather than a trained AI model.