510(k) Data Aggregation

    K Number
    K193020

    Validate with FDA (Live)

    Date Cleared
    2019-12-04

    (35 days)

    Product Code
    Regulation Number
    870.5800
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The VenaPro Vascular Therapy System is intended to be an easy to use portable system, prescribed by a physician, for use in the home or clinical setting to help prevent the onset of DVT in patients by stimulating blood flow in the extremities (stimulating muscle contractions). This device can be used to:

    • Aid in the prevention of DVT;
    • Enhance blood circulation;
    • Diminish post-operative pain and swelling;
    • Reduce wound healing time;
    • Aid in the treatment and healing of stasis dermatitis, venous stasis ulcers, arterial and diabetic leg ulcers, chronic venous insufficiency and reduction of edema in the lower limbs.

    The unit can also be used as an aid in the prophylaxis for DVT by persons expecting to be stationary for long periods of time.

    Device Description

    The VenaPro Vascular Therapy System is a lightweight, portable, rechargeable battery powered prescriptive device. It is intended to be used in the home or clinical setting by or under the direction of a medical professional to help stimulate blood flow as an aid in the prevention of deep vein thrombosis (DVT).

    The system utilizes pneumatically controlled, single chamber cuffs actuated by an electronically controlled air pump unit and solenoid valve. All pump, battery and control components are protectively housed in a plastic case that is permanently attached to a single use inflatable cuff. A single tactile touch control switch, tri-color LED for ON, LOW BATTERY, CHARGING and CHARGE COMPLETED indication, and a blue LED (for indicating a leak or low pressure alarm) provides for user interface. There is also a port for connecting the battery charger/AC adapter plug, and a currently unused port for future use in usage data reporting.

    The leg wrap (cuff) component consists of a Polyvinyl Chloride (PVC) air bladder encased inside a soft, non-woven medical fabric (a Polyester blended medical fabric) or equal , which is adhered to the PVC air bladder. The units are supplied clean, non-sterile, packaged in pairs (1 left and 1 right side).

    In operation, the user simply turns the power ON via the single button I/O control switch. A single user "cuff" containing air bladders is permanently connected to the unit. The control unit then fills the cuff to a pre-determined pressure (50 mmHg). Cuff pressure is monitored by an internal pressure switch and system software. Once the pressure reaches the proper level, the pump is turned OFF for an approximately 50 second "rest" period, and the cuff deflates to ambient pressure through a valve inside the plastic case. After the "rest" period, the cycle repeats until the unit is turned off.

    AI/ML Overview

    The provided text describes a 510(k) premarket notification for the VenaPro Vascular Therapy System, arguing for its substantial equivalence to a previously cleared predicate device (K133274). The document does not describe a study involving human readers or AI assistance, nor does it specify acceptance criteria for clinical performance. Instead, it focuses on non-clinical testing and a comparison of the device's technical characteristics with its predicate.

    Therefore, many of the requested pieces of information are not present in the provided document.

    Here's the information that can be extracted or inferred:

    1. Table of Acceptance Criteria and Reported Device Performance

    The document does not specify quantitative acceptance criteria for clinical performance. Instead, it focuses on demonstrating equivalence to a predicate device through technical specifications and non-clinical testing. The "performance" reported is primarily that the subject device meets the same specifications, functions, and safety standards as the predicate.

    Feature/CriterionPredicate Device (K133274) PerformanceSubject Device PerformanceEquivalence Notes
    Intended UseAid in DVT prevention, enhance blood circulation, diminish post-operative pain/swelling, reduce wound healing time, aid in treatment/healing of various ulcers/edema, DVT prophylaxis.Aid in DVT prevention, enhance blood circulation, diminish post-operative pain/swelling, reduce wound healing time, aid in treatment/healing of various ulcers/edema, DVT prophylaxis.Identical
    Prescription/OTCPrescriptionPrescriptionIdentical
    Power SourceRechargeable batteryRechargeable batteryIdentical
    Battery Specifications7.4V rechargeable battery3.7V rechargeable batteryThe voltage difference does not change product performance or parameters and does not raise new safety/effectiveness issues.
    Battery Charge Time~1.5 hours (from depleted)~2.5 hours (from depleted)The difference in charging time does not change product performance or parameters and does not raise new safety/effectiveness issues.
    Power Supply (Charger)Input: 100-240 Vac, Output: 10 Vdc @ 1.1 AmpInput: 100-240 Vac, Output: 5 Vdc @ 1 AmpThe voltage difference of the power supply (to match the changed battery) does not change product performance or parameters and does not raise new safety/effectiveness issues.
    Functions and DesignAids venous return via cyclic, intermittent pneumatic pressure (inflation/deflation) to compress lower limb(s).Aids venous return via cyclic, intermittent pneumatic pressure (inflation/deflation) to compress lower limb(s).Identical
    Working PressureDefault 50 mmHgDefault 50 mmHgIdentical
    Cycle Time60 seconds60 secondsIdentical
    System Diagnostics (Alarms)Audible/visual alarms for faults (low pressure, low battery, overpressure)Audible/visual alarms for faults (low pressure, low battery, overpressure)Identical
    Cuff MaterialSingle bladder PVC chambers, non-latex, non-woven medical fabric (Polyester blend)Single bladder PVC chambers, non-latex, non-woven medical fabric (Polyester blend)Identical or similar (predicate specified "or equivalent")
    Fastening (Plastic case & fabric wrap)GlueSnap and screwThe new fastening method (snap and screw) is hidden and does not raise new safety/effectiveness issues.
    BiocompatibilityBiocompatibleBiocompatibleIdentical
    SoftwareModerateModerateIdentical
    Dimensions131x66x37mm131x66x37mmIdentical or similar
    Weight~0.23kg~0.23kgIdentical or similar
    Temperature (Operating)+10 °C to +40 °C+10 °C to +40 °CIdentical
    Humidity (Operating)30%-75%30%-75%Identical
    Tolerances (Pressure)5%5%Identical
    Cleaning/DisinfectingSpecified proceduresSpecified proceduresIdentical
    DisposalSpecified proceduresSpecified proceduresIdentical

    2. Sample size used for the test set and the data provenance

    Not applicable/Not provided. This submission is for a medical device (compressible limb sleeve system) where substantial equivalence is demonstrated through comparison of technical specifications and non-clinical engineering tests, not a clinical study involving a "test set" of patient data for performance evaluation in the context of an AI device.

    3. Number of experts used to establish the ground truth for the test set and the qualifications of those experts

    Not applicable/Not provided. As above, no clinical "test set" requiring expert ground truth was described for this type of device submission.

    4. Adjudication method for the test set

    Not applicable/Not provided. No clinical "test set" requiring adjudication was described.

    5. If a multi-reader multi-case (MRMC) comparative effectiveness study was done, what was the effect size of how much human readers improve with AI vs without AI assistance

    Not applicable/Not provided. This document concerns a physical medical device (VenaPro Vascular Therapy System), not an AI diagnostic or assistance tool. Therefore, no MRMC study or AI assistance comparison was performed.

    6. If a standalone (i.e. algorithm only without human-in-the-loop performance) was done

    Not applicable/Not provided. This is not an AI device.

    7. The type of ground truth used

    The concept of "ground truth" as it applies to AI/software performance in image interpretation or diagnosis is not relevant here. The "truth" for this submission is based on adherence to engineering standards and technical specifications proven safe and effective by the predicate device.

    Specifically, non-clinical tests were performed to assure conformance with:

    • ANSI AAMI ES60601-1 "Medical Electrical Equipment Part 1: General requirements for basic safety and essential performance (IEC 60601-1)".
    • IEC 60601-1-2 "Medical Electrical Equipment Part 1-2: General Requirements for Basic Safety and Essential Performance - Collateral standard: Electromagnetic Compatibility - Requirements and Tests".
    • IEC 60601-1-11 "Medical Electrical Equipment Part 1-11: General Requirements For Basic Safety And Essential Performance - Collateral Standard: Requirements For Medical Electrical Equipment And Medical Electrical Systems Used In The Home Healthcare Environment".
    • IEC 62133-2 "Secondary Cells And Batteries Containing Alkaline Or Other Non-Acid Electrolytes -Safety Requirements For Portable Secondary Cells, And For Batteries Made From Them, For Use In Portable Applications - Part 2: Lithium Systems".
    • Bench tests for physical, electrical, and performance requirements.
    • Software verification according to FDA Guidance for the Content of Premarket Submissions for Software Contained in Medical Devices.

    8. The sample size for the training set

    Not applicable/Not provided. This is not an AI device.

    9. How the ground truth for the training set was established

    Not applicable/Not provided. This is not an AI device.

    Ask a Question

    Ask a specific question about this device

    K Number
    K133274

    Validate with FDA (Live)

    Device Name
    VENA PRO
    Date Cleared
    2014-02-12

    (111 days)

    Product Code
    Regulation Number
    870.5800
    Age Range
    All
    Reference & Predicate Devices
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The Vena Pro Vascular Therapy System, model VP-3111, is intended to be an easy to use portable system, prescribed by a physician, for use in the home or clinical setting to help prevent the onset of DVT in patients by stimulating blood flow in the extremities (simulating muscle contractions). This device can be used to:

    • Aid in the prevention of DVT; .
    • Enhance blood circulation; .
    • Diminish post-operative pain and swelling; .
    • Reduce wound healing time; .
    • Aid in the treatment and healing of: stasis dermatitis, venous stasis ulcers, arterial and . diabetic leg ulcers, chronic venous insufficiency and reduction of edema in the lower limbs.

    The unit can also be used as an aid in the prophylaxis for DVT by persons expecting to be stationary for long periods of time.

    Device Description

    The Vena Pro Vascular Therapy System is a lightweight, portable, rechargeable battery powered prescriptive device that is intended to be used in the home or clinical setting by or under the direction of a medical professional to help stimulate blood flow as an aid in the prevention of deep vein thrombosis (DVT).

    The system utilizes pneumatically controlled, single chamber cuffs actuated by an electronically controlled air pump unit and solenoid valve. All pump, battery and control components are protectively housed in a plastic case that is permanently attached to a single use inflatable cuff. A single tactile touch control switch, tri-color LED for ON, LOW BATTERY, CHARGING and CHARGE COMPLETED indication, and a blue LED (for indicating a leak or low pressure alarm) provides for user interface. There is also a port for connecting the battery charger/AC adapter plug, and a currently unused port for future use in usage data reportung.

    The leg wrap (cuff) component consists of a Polyvinyl Chloride (PVC) air bladder encased inside a soft, non-woven medical fabric made from Dupont Softesse (a Polyester blended medical fabric) or equal , which is adhered to the PVC air bladder. The units are supplied clean, non-sterile, packaged in pairs ( 1 left and 1 right side).

    In operation, the user simply turns the power ON via the single button I/O control switch. A single user "cuff" containing air bladders is permanently connected to the unit. The control unit then fills the cuff to a pre-determined pressure (50 mmHg). Cuff pressure is monitored by an internal pressure switch and system software. Once the pressure reaches the proper level, the pump is turned OFF for an approximately 50 second "rest" period, and the cuff deflates to ambient pressure through a valve inside the plastic case. After the "rest" period, the cycle repeats until the unit is turned off.

    AI/ML Overview

    Here's an analysis of the acceptance criteria and supporting studies for the Vena Pro Vascular Therapy System, based on the provided text:

    Acceptance Criteria and Device Performance

    The provided document describes the Vena Pro Vascular Therapy System (VP-3111) and its substantial equivalence to predicate devices, rather than establishing new, explicit acceptance criteria with specific numerical thresholds for its own performance. Instead, the "acceptance criteria" are implicitly met by demonstrating that the Vena Pro system has performance characteristics substantially equivalent to or surpassing those of the listed predicate devices.

    The core performance claims relate to:

    • Pressure Delivery: Approximately 50 mmHg.
    • Cuff Fill Time: Similar to predicate devices (e.g., 11.6 seconds for Venodyne).
    • Cycle Time: Approximately 60 seconds per leg.
    • Overall System Performance: Including electrical safety, EMC, mechanical integrity, environmental, and life cycle testing.

    Table of Implicit Acceptance Criteria and Reported Performance:

    Acceptance Criterion (Implicitly based on Predicate Devices)Reported Device Performance (Vena Pro VP-3111)
    Inflation PressureApproximately 50 mmHg
    Cuff Fill TimeSimilar to predicate devices (e.g., 11.6 seconds)
    Cycle TimeApproximately 60 seconds per leg
    Electrical SafetyMet (non-clinical validation)
    EMC (Electromagnetic Compatibility)Met (non-clinical validation)
    Mechanical IntegrityMet (non-clinical validation)
    Environmental PerformanceMet (non-clinical validation)
    Life Cycle TestingMet (non-clinical validation)
    Safety Alarms (Low pressure, low battery, overpressure)Built into the system, similar to predicates
    Clinical Efficacy (Aid in DVT prevention, blood flow stimulation)Substantially equivalent to predicate devices, supported by published clinical studies on predicate devices.

    Study Details

    1. Sample Size Used for the Test Set and Data Provenance:

    • Test Set: No specific test set for the Vena Pro device itself is mentioned for clinical evaluation. The document states, "No clinical testing was performed on the Vena Pro system."
    • Data Provenance: The justification for clinical effectiveness is based on retrospective analysis of published clinical studies conducted on predicate devices. These studies are:
      • "Evaluation of Intermittent Pneumatic Compression Devices" (Orthopedics 24(3):257-261, 2001)
      • "Venous hemodynamics after total knee arthroplasty: Evaluation of active dorsal to planar flexion and several mechanical compression devices" (Journal of Bone and Joint Surgery, November 1998)
        The provenance of the data within these external studies (e.g., country of origin) is not provided in this 510(k) summary.

    2. Number of Experts Used to Establish the Ground Truth for the Test Set and Qualifications of Those Experts:

    • This information is not applicable (N/A) as no clinical test set for the Vena Pro device itself was conducted. The ground truth for the predicate device studies would have been established by the methods described within those original publications, which are not detailed here. The 510(k) summary cites the conclusions of these studies.

    3. Adjudication Method for the Test Set:

    • N/A, as no clinical test set for the Vena Pro device was performed.

    4. Multi-Reader Multi-Case (MRMC) Comparative Effectiveness Study:

    • No, an MRMC comparative effectiveness study was not conducted as part of this 510(k) submission for the Vena Pro device. The submission relies on non-clinical bench testing and comparison to published clinical data on predicate devices. Therefore, no effect size of human readers improving with AI vs. without AI assistance is reported.

    5. Standalone Performance Study:

    • No standalone (algorithm only without human-in-the-loop performance) clinical study was performed for the Vena Pro device. "Non-clinical validation" and "in-house bench testing" were conducted for its technical features (pressure, cycle time, etc.), but this does not constitute a standalone clinical performance study in terms of patient outcomes or physiological effects.

    6. Type of Ground Truth Used:

    • For the Vena Pro device itself, the "ground truth" for technical specifications (e.g., pressure output, cycle time) was established through in-house bench testing.
    • For clinical efficacy claims (e.g., aid in DVT prevention), the ground truth is derived from the published outcomes data of clinical studies conducted on predicate devices, which are cited as surrogate clinical data. These predicate studies would have used various clinical outcomes to establish their efficacy (e.g., DVT rates, blood flow velocity measurements).

    7. Sample Size for the Training Set:

    • N/A. This device is a mechanical/pneumatic system, not an AI or machine learning algorithm that requires a "training set" in the computational sense.

    8. How the Ground Truth for the Training Set Was Established:

    • N/A, as there is no training set for this type of device.