Found 12 results

510(k) Data Aggregation

    K Number
    K250232

    Validate with FDA (Live)

    Date Cleared
    2025-07-25

    (179 days)

    Product Code
    Regulation Number
    874.4680
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    N/A
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The Vathin®H-SteriScopeTM single-use flexible video bronchoscope has been designed to be used with the Vathin display unit, endotherapy accessories and other ancillary equipment for endoscopy within the airways and tracheobronchial tree in patients.

    The Vathin® Video Bronchoscope System is for use in a hospital environment.

    The Vathin®H-SteriScopeTM single-use flexible video bronchoscope is a single-use device designed for use in adults, with the BCV1-02 and BCV1-C2 also designed for pediatric use (BCV1-02: 6 months to 6 years; BCV1-C2: 6 years and older).

    Device Description

    The Vathin® Video Bronchoscope System consists of Vathin®H-SteriScopeTM Single use flexible Video Bronchoscope (model: BCV1-02, BCV1-C2) to be introduced within the airways or tracheobronchial tree and Vathin®VisionCenterTM Digital Video Monitor (model: DVM-B1, DVM-B2) for clinical image processing.

    The Vathin®H-SteriScopeTM Single-use flexible bronchoscope is inserted through the airways and tracheobronchial tree during Bronchoscopy. The Vathin®VisionCentereTM Digital Video Monitor provides power and processes the images for medical electronic endoscope.

    Vathin®H-SteriScopeTM Single-use flexible Video Bronchoscope is a sterile single-use flexible bronchoscope. Vathin®H-SteriScopeTM Digital Video Monitor is a reusable monitor.

    AI/ML Overview

    I regret to inform you that the provided FDA 510(k) clearance letter and accompanying 510(k) Summary for the Vathin® Video Bronchoscope System do not contain the specific information required to answer your detailed questions about acceptance criteria and the study proving device performance as it relates to AI/software functionality.

    This document focuses on justifying Substantial Equivalence for a bronchoscope system based on its physical characteristics, safety standards (electrical, biocompatibility, sterilization), and basic performance (optical, mechanical). It mentions "Software verification and validation" in Section 7.4, citing the "FDA guidance: Content of Premarket Submissions for Device Software Functions," but does not provide any specific acceptance criteria, study data, or details about the software's functionality, especially regarding AI capabilities.

    Therefore, I cannot populate the table or answer the specific questions about AI performance, test set details, ground truth establishment, or human reader studies.

    Here's why the document is insufficient for your request:

    • No AI/Algorithm Claims: The document describes a video bronchoscope and its display unit. It doesn't mention any AI or advanced algorithmic functions (e.g., automated lesion detection, image enhancement using AI, diagnostic support) that would necessitate performance criteria like sensitivity, specificity, or reader studies.
    • Focus on Hardware/System Performance: The performance data section (7.1-7.6) primarily addresses the physical and electrical safety, biocompatibility, sterilization, and basic optical/mechanical functions of a medical device (bronchoscope). The "Software verification and validation" entry is generic and doesn't detail any specific software performance study.
    • Substantial Equivalence Justification: The entire 510(k) submission aims to prove that the Vathin® Video Bronchoscope System is "substantially equivalent" to existing cleared bronchoscopes. This process typically focuses on demonstrating comparable safety and effectiveness, not necessarily advanced algorithmic performance.

    To answer your questions, one would need a 510(k) that specifically addresses an AI/ML-enabled medical device. Such a submission would include detailed performance studies with metrics like sensitivity, specificity, AUC, and often include multi-reader, multi-case (MRMC) studies to demonstrate clinical impact.

    If you had provided a 510(k) document for an AI-powered device, the table and answers would look something like this (conceptual example):


    Conceptual Example - This section is not based on the provided document as it does not contain the necessary information.

    For an AI-powered medical device, the acceptance criteria and study proving its performance would be detailed as follows:

    1. Acceptance Criteria and Reported Device Performance

    Metric (for AI-enabled feature, e.g., Nodule Detection)Acceptance Criteria (e.g., for standalone performance)Reported Device Performance
    Standalone Performance
    Sensitivity (Recall)≥ 90% for nodules > 4mm92.5%
    Specificity≥ 80%83.1%
    FROC Score (Free-response ROC)≥ 0.850.87
    AI-Assisted Performance (If applicable)
    Reader ROC AUC ImprovementStatistically significant improvement (p < 0.05) vs. unaidedMean AUC improvement of 0.045 (p < 0.001)
    Reading Time ReductionMean reading time reduction of ≥ 10%15% reduction

    2. Sample Size and Data Provenance for Test Set

    • Test Set Size: 500 unique patient studies (e.g., Chest CT scans).
    • Data Provenance:
      • Country of Origin: Multi-centric from USA (40%), Europe (30%), Asia (30%).
      • Retrospective/Prospective: Primarily retrospective, collected from hospital PACS archives. Data selection ensured diversity in pathology, image quality, and scanner types.

    3. Number and Qualifications of Experts for Ground Truth

    • Number of Experts: 3 independent expert readers.
    • Qualifications: All were board-certified radiologists with subspecialty training in thoracic imaging and a minimum of 10 years of experience in interpreting chest CT scans for pulmonary nodules.

    4. Adjudication Method for Test Set

    • Method: 2+1 Adjudication.
      • Initial reads by two independent expert radiologists.
      • If their interpretations differed, a third, senior-most expert radiologist reviewed the case and made the final decision.
      • Discrepancies were resolved through consensus or majority vote. All disagreements requiring a third read were documented.

    5. Multi-Reader Multi-Case (MRMC) Comparative Effectiveness Study

    • Was it done? Yes.
    • Effect Size (Human Readers Improvement with AI vs. Without AI):
      • The MRMC study demonstrated a statistically significant improvement in diagnostic accuracy (measured by ROC AUC) for radiologists using the AI device compared to those reading without AI assistance.
      • Mean ROC AUC: 0.85 (without AI) vs. 0.895 (with AI).
      • Effect Size: Mean improvement in AUC was 0.045 (absolute difference), which corresponds to a relative improvement of approximately 5.3% in diagnostic accuracy. The 95% confidence interval for this improvement did not include zero, confirming statistical significance (p < 0.001).
      • Additional Finding: Average reading time per case decreased by 15% when using AI.

    6. Standalone Performance Study

    • Was it done? Yes.
    • Details: The algorithm's performance was evaluated independently against the established ground truth for nodule detection and characterization. Standalone metrics included sensitivity, specificity, and FROC analysis, as detailed in the acceptance criteria table above.

    7. Type of Ground Truth Used for Test Set

    • Type: Expert Consensus, supported by available pathology reports (where biopsy was performed) and longitudinal follow-up data (e.g., 2-year stability on subsequent CT scans for benign lesions, or growth for malignant lesions). Pathology or follow-up was prioritized when available.

    8. Sample Size for Training Set

    • Training Set Size: 50,000 unique patient studies (e.g., Chest CT scans).

    9. How Ground Truth for Training Set was Established

    • Method: A combination of automated data labeling (using existing radiology reports, structured data, and keywords) followed by expert review and annotation.
      • An initial pass of automated labeling identified potential regions of interest.
      • These regions were then reviewed and carefully annotated by a team of trained radiology residents and fellows under the supervision of experienced radiologists.
      • For ambiguous cases, a consensus reading of at least two radiologists was required.
      • Pathology reports and longitudinal follow-up data (when available) were also incorporated to refine annotations and confirm ground truth.
    Ask a Question

    Ask a specific question about this device

    K Number
    K251599

    Validate with FDA (Live)

    Date Cleared
    2025-07-03

    (37 days)

    Product Code
    Regulation Number
    876.1500
    Age Range
    18 - 120
    Reference & Predicate Devices
    Predicate For
    N/A
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The Single-use Ureteral Access Sheath is used to establish a conduit during endoscopic urological procedures facilitating the passage of endoscopes and other instruments into the urinary tract.

    Device Description

    The Single-use Ureteral Access Sheath is a prescription device intended to provide physicians with access to the urinary tract and the capability to serve as a pathway for device exchanges. Similar to all ureteral access sheath sets, this device also safeguards the ureter during device exchanges, thus helping to minimize tissue trauma. The Single-use Ureteral Access Sheath consists of two components: the inner semi-rigid dilator assembly and the outer semi-rigid sheath assembly, both of which have a hydrophilic coating to allow for smooth and easy deployment into the upper tracts over a preplaced ureteral guidewire. The sheath has a locking mechanism that attaches to the luer lock hub of the inner dilator, allowing the sheath and dilator to move as a single unit. To ease the insertion of the Single-use Ureteral Access Sheath into the body orifice, the dilator is advanced over a 0.038 inch guidewire. Since both the sheath and dilator are radiopaque, they can be monitored using X-ray (fluoroscopy) to ensure their accurate positioning during the placement process. The Single-use Ureteral Access Sheath is designed to accommodate endoscopes and other urological instruments with an outer diameter (OD) that is compatible with the sheath's inner diameter (ID) of 10Fr, 11Fr, 12Fr, 13Fr, and 14Fr. The inner layer of the sheath is made of stainless steel to provide radial rigidity that remains patent and intact after the dilator is removed, allowing endoscopes and other urological instruments to pass easily along the lumen of the Access Sheath. The Single-use Ureteral Access Sheath is offered in five French size combinations: 10Fr/12Fr, 11Fr/13Fr, 12Fr/14Fr, 13Fr/15Fr, and 14Fr/16Fr, and four lengths: 35cm, 45cm, 50cm, 55cm. The device is constructed using biologically safe materials and is provided in a sterile condition, intended for single use only.

    AI/ML Overview

    The provided 510(k) clearance letter is for a "Single-Use Ureteral Access Sheath" (K251599), which is a physical medical device and not an AI or software-based device.

    Therefore, many of the requested points related to AI/software performance, such as:

    • MRMC comparative effectiveness study
    • Standalone (algorithm only) performance
    • Sample size and ground truth for training set
    • Number of experts and their qualifications for ground truth establishment
    • Adjudication method for test set

    do not apply to this device and its associated performance data.

    The performance data provided in the 510(k) summary focuses entirely on non-clinical performance data for a physical device, including:

    • Biocompatibility Testing
    • Sterility Testing
    • Functional and Mechanical Performance Testing (e.g., appearance, size, patency, breaking force, friction, etc.)

    Based on the information provided in the 510(k) clearance letter for the Single-Use Ureteral Access Sheath (K251599), here's a breakdown of the requested information:

    1. A table of acceptance criteria and the reported device performance

    The document lists various performance tests conducted but does not explicitly state the quantitative acceptance criteria for each test or the specific numerical results obtained. It generally states that "All evaluation acceptance criteria were met" for biocompatibility and implies successful results for performance testing by concluding substantial equivalence.

    Performance Attribute/Test CategoryAcceptance Criteria (Implicit from document)Reported Device Performance (Implicit from document)
    BiocompatibilityMet ISO 10993-1:2018 recommendations for "breached or compromised surface," "Limited (<24 hours)" contact duration."All evaluation acceptance criteria were met" for Cytotoxicity, Irritation, Sensitization, Pyrogenicity, and Acute systemic toxicity.
    SterilityMet ISO 11607 for sterile barrier systems; Sterilization process validated per ISO 11135.Validated sterilization process and evaluated sterile barrier systems were successful.
    Functional & Mechanical PerformanceDemonstrated safety and effectiveness comparable to predicate device.• Appearance: Met internal specifications• Mark: Met internal specifications• Size: Met internal specifications• Luer fitting: Functioned as intended• Patency: Confirmed• Freedom from leakage: Confirmed• Resistance to deformation: Confirmed• Breaking force: Met internal specifications• Connection firmness: Confirmed• Toughness: Confirmed• Flexural properties: Confirmed• Anti-twisting force: Confirmed• Compression Resistance: Confirmed• Compatibility: With 0.038" guidewire, endoscopes, and other urological instruments of compatible OD.• Air pressure Regulation Function: Confirmed• Negative Pressure Suction Function: Confirmed• Bending Reliability: Confirmed• Corrosion resistance: Confirmed• Friction: Within acceptable limits for smooth deployment• Coating Uniformity: Confirmed• Firmness: Confirmed• Chemical Property: Met internal specifications

    2. Sample size used for the test set and the data provenance

    The document does not specify the sample sizes used for the non-clinical performance and mechanical testing. It also doesn't mention data provenance in terms of country of origin or retrospective/prospective for this type of testing, as it's laboratory-based physical device testing, not clinical data or real-world usage data.

    3. Number of experts used to establish the ground truth for the test set and the qualifications of those experts

    This concept (experts establishing ground truth) is not applicable to the non-clinical, physical device testing described. The "ground truth" for physical device performance is established by standardized test methods and engineering specifications.

    4. Adjudication method (e.g. 2+1, 3+1, none) for the test set

    Not applicable to non-clinical, physical device testing.

    5. If a multi reader multi case (MRMC) comparative effectiveness study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance

    Not applicable. This is a physical medical device, not an AI or imaging diagnostic software.

    6. If a standalone (i.e. algorithm only without human-in-the-loop performance) was done

    Not applicable. This is a physical medical device, not an algorithm.

    7. The type of ground truth used (expert consensus, pathology, outcomes data, etc)

    For this device, the "ground truth" or reference standards are:

    • Biocompatibility: ISO 10993-1:2018 (international standard for biological evaluation of medical devices).
    • Sterilization: ISO 11607 (packaging for terminally sterilized medical devices) and ISO 11135 (ethylene oxide sterilization for medical devices).
    • Functional/Mechanical Performance: Internal engineering specifications and established test methods for physical characteristics, likely derived from industry standards and predicate device performance.

    8. The sample size for the training set

    Not applicable. This is a physical device, not a machine learning model requiring a "training set."

    9. How the ground truth for the training set was established

    Not applicable.

    Ask a Question

    Ask a specific question about this device

    K Number
    K240167

    Validate with FDA (Live)

    Date Cleared
    2024-10-08

    (260 days)

    Product Code
    Regulation Number
    876.1500
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The Single-use Ureteral Access Sheath is used to establish a conduit during endoscopic urological procedures, facilitating the passage of endoscopes and other instruments into the urinary tract.

    Device Description

    The Single-use Ureteral Access Sheath is a prescription device intended to provide physicians with access to the urinary tract and the capability to serve as a pathway for device exchanges. Similar to all ureteral access sheath sets, this device also safeguards the ureter during device exchanges, thus helping to minimize tissue trauma. The Single-use Ureteral Access Sheath consists of two components: the inner semi-rigid dilator assembly and the outer semi-rigid sheath assembly, both of which have a hydrophilic coating to allow for smooth and easy deployment into the upper tracts over a preplaced ureteral guidewire. The sheath has a locking mechanism that attaches to the luer lock hub of the inner dilator, allowing the sheath and dilator to move as a single unit. To ease the insertion of the Single-use Ureteral Access Sheath into the body orifice, the dilator is advanced over a 0.038 inch guidewire. Since both the sheath and dilator are radiopaque, they can be monitored using X-ray (fluoroscopy) to ensure their accurate positioning during the placement process. The Single-use Ureteral Access Sheath is designed to accommodate endoscopes and other urological instruments with an outer diameter (OD) that is compatible with the sheath's inner diameter (ID) of 10Fr, 11Fr, 13Fr, and 14Fr. The inner layer of the sheath is made of stainless steel to provide radial rigidity that remains patent and intact after the dilator is removed, allowing endoscopes and other urological instruments to pass easily along the lumen of the Access Sheath. The Single-use Ureteral Access Sheath is offered in five French size combinations: 10Fr/12Fr, 11Fr/13Fr, 12Fr/14Fr, 13Fr/15Fr, and 14Fr/16Fr, and two lengths: 35cm and 45cm. The device is constructed using biologically safe materials and is provided in a sterile condition, intended for single use only.

    AI/ML Overview

    The device in question is the Single-use Ureteral Access Sheath (K240167). The provided document is a 510(k) summary, which outlines the device's characteristics and the studies performed to demonstrate its substantial equivalence to a legally marketed predicate device.

    Here's a breakdown of the requested information based on the provided text:

    1. A table of acceptance criteria and the reported device performance

    The document details performance testing for various attributes. While it states "All evaluation acceptance criteria were met" for specific categories (e.g., Biocompatibility), it does not explicitly list numerical or qualitative acceptance criteria for each functional/mechanical test in a table form, nor does it provide the exact reported performance values. It only lists the tests conducted.

    CategoryAcceptance Criteria (Stated/Implied)Reported Device Performance
    BiocompatibilityIn accordance with ISO 10993-1:2018 (no cytotoxicity, no irritation, no sensitization, met pyrogenicity and acute systemic toxicity requirements)All evaluation acceptance criteria were met.
    SterilitySterile barrier systems met ISO 11607; sterilization process validated per ISO 11135.Validated in accordance with ISO 11135 and ISO 11607.
    Functional/Mechanical PerformanceImplicitly, met standards for safe and effective use comparable to the predicate device.All tests listed below were conducted (see section VII for tests listed). The results supported substantial equivalence.
    - Appearance(Not explicitly stated, but implies acceptable visual quality)Conducted
    - Mark(Not explicitly stated, but implies clear and correct marking)Conducted
    - Size(Not explicitly stated, but implies dimensional accuracy)Conducted
    - Luer fitting(Not explicitly stated, but implies proper fitting)Conducted
    - Patency(Not explicitly stated, but implies open and unobstructed lumen)Conducted
    - Freedom from leakage(Not explicitly stated, but implies no leaks)Conducted
    - Resistance to deformation(Not explicitly stated, but implies maintaining structural integrity)Conducted
    - Breaking force(Not explicitly stated, but implies adequate strength)Conducted
    - Connection firmness(Not explicitly stated, but implies secure connections)Conducted
    - Toughness(Not explicitly stated, but implies resistance to fracture)Conducted
    - Flexural properties(Not explicitly stated, but implies appropriate flexibility)Conducted
    - Anti-twisting force(Not explicitly stated, but implies resistance to twisting)Conducted
    - Compression Resistance(Not explicitly stated, but implies resistance to compression)Conducted
    - Compatibility(Not explicitly stated, but implies compatibility with other instruments)Conducted
    - Air pressure Regulation Function(Not explicitly stated, but implies proper function)Conducted
    - Negative Pressure Suction Function(Not explicitly stated, but implies proper function)Conducted
    - Bending Reliability(Not explicitly stated, but implies reliable bending without failure)Conducted
    - Corrosion resistance(Not explicitly stated, but implies resistance to corrosion)Conducted
    - Friction(Not explicitly stated, but implies acceptable friction during use)Conducted
    - Coating Uniformity(Not explicitly stated, but implies consistent coating application)Conducted
    - Firmness(Not explicitly stated, but implies appropriate rigidity/stiffness)Conducted
    - Chemical Property(Not explicitly stated, but implies appropriate chemical composition)Conducted

    2. Sample size used for the test set and the data provenance (e.g. country of origin of the data, retrospective or prospective)

    The document does not specify the sample sizes used for any of the non-clinical performance tests (biocompatibility, sterility, functional/mechanical testing).
    The data provenance is not explicitly stated as retrospective or prospective, nor is the country of origin of the data mentioned for the performance testing. However, the applicant is Hunan Vathin Medical Instrument Co., Ltd., located in China, suggesting the testing was likely conducted by or for the manufacturer.

    3. Number of experts used to establish the ground truth for the test set and the qualifications of those experts (e.g. radiologist with 10 years of experience)

    This device is a physical medical instrument (Ureteral Access Sheath), not an AI/Software as a Medical Device (SaMD) that requires expert consensus for ground truth establishment. Therefore, this information is not applicable. The "ground truth" for this device is based on objective measurements and compliance with recognized standards.

    4. Adjudication method (e.g. 2+1, 3+1, none) for the test set

    As this is not a clinical study involving human interpretation or subjective assessment necessitating adjudication, this information is not applicable. Adjudication methods like 2+1 or 3+1 are typically used for establishing ground truth in clinical imaging or diagnostic studies.

    5. If a multi-reader multi-case (MRMC) comparative effectiveness study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance

    No MRMC study was conducted. This device is a physical medical instrument and does not involve AI assistance or human reader interpretation in its intended use.

    6. If a standalone (i.e. algorithm only without human-in-the loop performance) was done

    This refers to AI/software performance. This device is a physical medical instrument, so this concept is not applicable.

    7. The type of ground truth used (expert consensus, pathology, outcomes data, etc.)

    The "ground truth" used for this device's performance evaluation is based on objective measurements and tests against established engineering, material, and biocompatibility standards. For example:

    • Biocompatibility: In vitro and in vivo tests according to ISO 10993-1, measured against scientific criteria (e.g., cell viability for cytotoxicity, skin reaction for irritation).
    • Sterility: Measured by sterility assurance level (SAL) achieved through validated sterilization processes per ISO 11135.
    • Functional/Mechanical: Measured by physical properties (e.g., dimensions, force resistance, patency, leakage) against pre-defined specifications derived from engineering principles and comparison to the predicate device.

    8. The sample size for the training set

    This device does not involve a "training set" in the context of machine learning or AI. It is a physical medical device.

    9. How the ground truth for the training set was established

    As there is no training set for this physical device, this question is not applicable.

    Ask a Question

    Ask a specific question about this device

    K Number
    K241434

    Validate with FDA (Live)

    Date Cleared
    2024-10-04

    (136 days)

    Product Code
    Regulation Number
    876.1500
    Age Range
    N/A
    Reference & Predicate Devices
    N/A
    Predicate For
    N/A
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use
    Device Description
    AI/ML Overview
    Ask a Question

    Ask a specific question about this device

    K Number
    K231135

    Validate with FDA (Live)

    Date Cleared
    2024-01-17

    (271 days)

    Product Code
    Regulation Number
    876.1500
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The Single-use Flexible Ureteroscope is designed for use with Vathin Display Units, endotherapy accessories and other ancillary devices for the endoscopy and endoscopic surgery within urinary tract and kidney in adults.

    The Digital Video Monitor is specially designed to be used with medical endoscopes and other auxiliary equipment for the purposes of endoscopic diagnosis, treatment and video observation.

    Device Description

    The Video Ureteroscope System consists of Single-use Flexible Ureteroscope (Model:US-S2600, US-E2600) and Digital Video Monitor(Model:DVM-B1) . During diagnosis and treatment with the Video Ureteroscope System, the Single-use Flexible Ureteroscope is inserted into the ureter or into the kidney or renal pelvis through the ureter, and the image sensor (CMOS) at the end of the Single-use Flexible Ureteroscope converts the received mucosal reflected light signals into electrical signals , transmitted to the Digital Video Monitor through the cable, the Digital Video Monitor receives the image signal from the endoscope and processes it, converts it into an image signal that can be displayed on the display screen, and finally presents it on the screen of the display.

    AI/ML Overview

    I am sorry, but the provided text from the FDA 510(k) notification for the "Video Ureteroscope System" does not contain any information about acceptance criteria or a study proving the device meets those criteria in the context of an AI/ML powered medical device.

    The document primarily focuses on:

    • Substantial equivalence to a predicate device (another ureteroscope system).
    • Device description (components, how it works).
    • Indications for use.
    • Comparison of technological characteristics with the predicate device.
    • Summary of non-clinical tests (biocompatibility, sterility, electrical safety, EMC, and general performance testing).

    There is no mention of an AI or Machine Learning component in the device. Therefore, the requested information regarding:

    1. A table of acceptance criteria and reported device performance for an AI/ML system.
    2. Sample size and data provenance for an AI/ML test set.
    3. Number and qualifications of experts for AI/ML ground truth.
    4. Adjudication method for AI/ML ground truth.
    5. MRMC comparative effectiveness study results for AI assistance.
    6. Standalone performance of an AI algorithm.
    7. Type of ground truth for an AI system.
    8. Sample size for an AI training set.
    9. Ground truth establishment for an AI training set.

    cannot be extracted from this document.

    The document states that "Performance testing was conducted on the Video Ureteroscope System." (page 8), but it does not detail what specific performance tests were conducted, what the acceptance criteria were for those tests, or the results, beyond a general statement that "The non-clinical testing demonstrates that the device is as effective and performs as well as the legally marketed device." This general statement refers to the functional performance of the ureteroscope system itself (e.g., image quality, bending angle, working length, irrigation, etc.) compared to its predicate, not the performance of an AI algorithm.

    Ask a Question

    Ask a specific question about this device

    K Number
    K230536

    Validate with FDA (Live)

    Date Cleared
    2023-06-14

    (107 days)

    Product Code
    Regulation Number
    874.4760
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    N/A
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The Single-use Flexible Rhinolaryngoscope is designed to be used with the Digital Video Monitor, for examination of nasal cavity and upper respiratory tract. For Rhinolaryngoscope models that include a working channel and permit the use of a compatible 3rd party accessory, treatment is also possible.

    The Digital Video Monitor is specially designed to be used with endoscopes and other auxiliary equipment for the purposes of endoscopic diagnosis, treatment and video observation.

    The Vathin® Video Rhinolaryngoscope System is for use in a hospital environment.

    Device Description

    The Vathin® Video Rhinolaryngoscope System consists of Single-use flexible Rhinolaryngoscope (eight models shown in below) and Digital Video Monitor (model: DVM-A1, DVM-A2, DVM-B1, DVM-B2) for clinical image processing and display.

    The Single-use Flexible Rhinolaryngoscope is designed for use with Vathin Display Units, for examination of nasal cavity and upper respiratory tract. For Rhinolaryngoscope models that include a working channel and permit the use of a compatible 3rd party accessory, treatment is also possible.

    The Digital Video Monitor is specially designed to be used with compatible Vathin endoscopes and other auxiliary equipment for the purposes of endoscopic diagnosis, treatment and video observation.

    There are eight subject nasopharyngoscope models: RL-S1800, RL-S1801, RL-E1800, RL-E1801, RL-S1E00, RL-S1E01, RL-E1E00, RL-E1E01. The main differences between product models are in the working channel inner diameter (whether channel is present or not), outer diameter, and rotate function.

    Single-use flexible Rhinolaryngoscope is a sterile single Rhinolaryngoscope. Digital Video Monitor is a reusable monitor.

    The light emitted by the LED cold light source of the Single-use flexible Rhinolaryngoscope lens is irradiated into the body cavity, and the light reflected from the cavity enters the optical system and is imaged on the CMOS (complementary metal oxide semiconductor). The CMOS acquisition image is controlled by the CMOS drive circuit, and the standard color video signal is output to the Digital Video Monitor via the encoding circuit. The Digital Video Monitor adjusts the brightness of the light source or corrects the image according to the video signal output from the CMOS, and outputs the corrected standard color video signal.

    Single-use flexible Rhinolaryngoscope has the following physical and performance characteristics:

    • Maneuverable tip controlled by the user .
    • Flexible insertion cord .
    • Camera and LED light source at the distal tip .
    • . Sterilized by Ethylene Oxide
    • For single use

    The differences between the Single-use flexible Rhinolaryngoscope models are as follow:

    • . Have or haven't working channel
    • . Working channel inner diameter
    • . Insertion tube outer diameter
    • . The length of insertion tube
    AI/ML Overview

    Here's an analysis of the provided text regarding the acceptance criteria and study for the device, organized according to your requested information:

    Device: Vathin® Video Rhinolaryngoscope System (includes Single-use Flexible Rhinolaryngoscope and Digital Video Monitor)

    1. A table of acceptance criteria and the reported device performance

    The provided document describes the device's technical specifications and reports that all evaluation acceptance criteria were met for the non-clinical tests. However, it does not explicitly state numerical acceptance criteria for each performance parameter, nor does it provide a direct comparison table of "acceptance criteria vs. reported performance" in a quantitative manner. Instead, it lists the tests performed and implies compliance.

    Below is a table summarizing the reported device performance characteristics where numerical values are given, and notes where general compliance is stated without specific numerical acceptance criteria.

    FeatureReported Device PerformanceAcceptance Criteria (Implied / Stated)
    Rhinolaryngoscope
    Field of View (degree)110°Not explicitly stated, but "larger (than predicate) is beneficial"
    Direction of View (degree)Not explicitly stated
    Bending Angle (degree)Up: 210°, Down: 210°Not explicitly stated, but "larger (than predicate) means more flexibility"
    Max Insertion Portion Width (mm)RL-S1800, etc.: 3.2; RL-S1E00, etc.: 5.0Not explicitly stated, but "smaller (than predicate) for easier patient entry"
    Min Insertion Channel Width (mm)RL-S1800, etc.: 0; RL-S1E00, etc.: 2.2Not explicitly stated, but "larger (than predicate) is more convenient for doctors"
    Working Length (mm)300"Meets the needs of clinical use," considered substantially equivalent to predicate's 350mm
    Illumination SourceLEDSame as predicate
    Single-UseYesSame as predicate
    BiocompatibilityNo Cytotoxicity, No Irritation to Skin, No significant evidence of sensitization, No pyrogenAll evaluation acceptance criteria were met (based on ISO 10993-1)
    SterilizationEOSame as predicate
    Digital Video Monitor
    Max. Resolution1280 x 800Not explicitly stated, but higher than reference device's 800x480
    Display Type12.1" touch screenNot explicitly stated, but different from reference device's 8.5" colour TFT LCD
    USB ConnectionA-typeSame as reference device
    Video OutputHDMI/USB 2.0Different from reference device's RCA connection
    Image/Video CaptureYesSame as reference device
    Electrical Safety / EMCSystem complies with standardsIEC 60601-1, IEC60601-2-18 for safety; IEC 60601-1-2 for EMC
    Other Performance TestsAll "evaluation acceptance criteria were met"(Tests listed in Section VII: Appearance, dimensions and weight, Functional performance)

    2. Sample size used for the test set and the data provenance (e.g. country of origin of the data, retrospective or prospective)

    The document comprehensively lists various non-clinical tests conducted (Biocompatibility, Electrical Safety/EMC, Performance testing including Appearance, Dimensions, Weight, and Functional Performance). However, it does not specify the sample size used for any of these test sets, nor does it provide information on the country of origin of the data or whether the studies were retrospective or prospective. These were non-clinical, bench-top tests.

    3. Number of experts used to establish the ground truth for the test set and the qualifications of those experts (e.g. radiologist with 10 years of experience)

    The document describes non-clinical, bench-top testing. For such tests, the "ground truth" is typically established by industry standards, engineering specifications, and validated measurement methods, rather than by human expert consensus or qualifications in the medical sense for diagnostic performance. Therefore, no information on the number or qualifications of experts for establishing ground truth is provided or relevant in this context.

    4. Adjudication method (e.g. 2+1, 3+1, none) for the test set

    Since the study described involves non-clinical engineering and performance testing, rather than human interpretation of medical data, the concept of an "adjudication method" (like 2+1 or 3+1 for resolving discrepancies in expert interpretations) is not applicable and not mentioned.

    5. If a multi reader multi case (MRMC) comparative effectiveness study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance

    No MRMC comparative effectiveness study was mentioned or performed. This submission is for a medical device (endoscope system) and not an AI-powered diagnostic tool. The focus is on the substantial equivalence of the hardware's performance and safety.

    6. If a standalone (i.e. algorithm only without human-in-the-loop performance) was done

    No standalone algorithm performance study was mentioned or performed. This device is a physical Rhinolaryngoscope and Digital Video Monitor, not a software algorithm.

    7. The type of ground truth used (expert consensus, pathology, outcomes data, etc.)

    For the non-clinical tests conducted:

    • Biocompatibility: Ground truth was established by adherence to ISO 10993-1:2018 standards and validated laboratory tests (Cytotoxicity, Irritation, Sensitization, Pyrogenicity, Acute systemic toxicity).
    • Electrical Safety and Electromagnetic Compatibility (EMC): Ground truth was established by compliance with international standards (IEC 60601-1, IEC60601-2-18, IEC 60601-1-2).
    • Performance Testing (Appearance, Dimensions, Weight, Functional Performance): Ground truth was established by engineering specifications and validated measurement methods as defined in the test protocols (e.g., measuring angles, lengths, diameters, image quality parameters).

    8. The sample size for the training set

    Not applicable. This submission describes a hardware medical device, not a machine learning or AI model that requires a "training set."

    9. How the ground truth for the training set was established

    Not applicable. As above, no training set was used.

    Ask a Question

    Ask a specific question about this device

    K Number
    K230200

    Validate with FDA (Live)

    Date Cleared
    2023-05-18

    (113 days)

    Product Code
    Regulation Number
    876.1500
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The Single-use Flexible Ureteroscope is designed for use with Vathin Display Units, endotherapy accessories and other ancillary devices for the endoscopy and endoscopic surgery within urinary tract and kidney in adults.

    Device Description

    The Single-use Flexible ureteroscope can be connected to the compatible Vathin Display Units and other accessories for the endoscopy and endoscopic surgery within urinary tract and kidney in adults. The Single-use Flexible ureteroscope is provided sterile (sterilized by EO) and intended to be single-use. The compatible Digital Video Monitor: Model: DVM-A1. The Single-use Flexible ureteroscope and Display Unit make up the video ureteroscope system. During diagnosis and treatment with the video ureteroscope system, the Single-use Flexible ureteroscope is inserted into the ureter or into the kidney or renal pelvis through the ureter, and the image sensor (CMOS) at the end of the Single-use Flexible ureteroscope converts the received mucosal reflected light signals into electrical signals, transmitted to the Display Unit through the cable, the Display Unit receives the image signal from the endoscope and processes it, converts it into an image signal that can be displayed on the display screen, and finally presents it on the screen of the display. There are 4 models of Single-Use Flexible Ureteroscope, the difference between US-S170 and US-E170,US-S180 and US-E180 lies in the US-SXXX series with self-lock and suction function, US-EXXX series does not come with self-lock and suction functions, the rest is exactly the same. The difference between the 2 models of US-EXXX series lies in work channel ID, head OD and outer diameter of main hose OD, while the rest are exactly the same. The difference between the 2 models of US-SXXX series also lies in work channel ID, head OD and outer diameter of main hose OD, and the rest are the same. The Single-use Flexible Ureteroscope includes insertion part, control part, connection part. The control part is made with ABS, contacted with users. The insertion part, as the part connected with patients, includes the sheath which is braided tube made with PEBAX tube, the bending section and the distal end. The bending section is made of snake bone, covered with snake bend eraser. The distal end is made of sensor and LED.

    AI/ML Overview

    The provided text describes the regulatory filing for a medical device (Single-use Flexible Ureteroscope) and details the non-clinical tests performed to demonstrate its substantial equivalence to a predicate device. However, it does not contain information about a study proving the device meets specific acceptance criteria related to its performance in a clinical setting or its impact on human readers, especially regarding AI assistance. The document focuses on physical, optical, electrical and biocompatibility performance.

    Therefore, I cannot provide the requested information about acceptance criteria for clinical performance or studies involving human readers/AI assistance based on the text.

    However, I can extract information regarding the non-clinical performance acceptance criteria and proof as described in the document.

    Here's an interpretation based on the provided text, focusing on the available non-clinical performance and acceptance testing:

    Device: Single-use Flexible Ureteroscope

    Study Type: Non-clinical Performance Testing and Biocompatibility Testing (for 510(k) Substantial Equivalence)

    1. Table of Acceptance Criteria (Non-Clinical) and Reported Device Performance:

    The document mentions that "All evaluation acceptance criteria were met" for biocompatibility and that the device "complies with" relevant electrical safety and EMC standards. For functional, mechanical, and optical performance, it lists the tests performed, implying that the device passed these tests to demonstrate equivalence. Specific quantitative acceptance values are not explicitly stated for all tests, but compliance with standards and successful completion of tests serve as the "proof."

    CategoryTest PerformedAcceptance Criteria (Implied)Reported Device Performance (Implied)
    BiocompatibilityCytotoxicityNo Cytotoxicity (as per ISO 10993-1:2018)Met acceptance criteria
    IrritationNo Irritation to Skin (as per ISO 10993-1:2018)Met acceptance criteria
    SensitizationNo significant evidence of sensitization (as per ISO 10993-1:2018)Met acceptance criteria
    Pyrogenicity(Not explicitly stated for acceptance, but implied by ISO)Met acceptance criteria
    Acute Systemic Toxicity(Not explicitly stated for acceptance, but implied by ISO)Met acceptance criteria
    SterilitySterile barrier systems evaluationCompliance with ISO 11607Complies
    Sterilization process validationCompliance with ISO 11135Validated
    Electrical SafetyElectrical safety testingCompliance with IEC 60601-1 and IEC 60601-2-18Complies
    ElectromagneticEMC testingCompliance with IEC 60601-1-2Complies
    Functional PerformanceAppearance, Working length, Work channel ID, Head OD, Outer diameter of main hose, Max outer diameter of insertion part, Bending angle, Product weight, Rotating sleeve, Handle-based photographing function, Self-locking function, Wire length, Image display, Waterproofness, Lens fogging, Image quality, LED illuminance test, LED color temperature test, Air tightness test, Suction ability, Water delivery ability, LED temperature testMet design specifications and intended performancePassed/Met (Implied by conclusion of substantial equivalence)
    Mechanical PerformanceHandle-based camera button reliability, Passively bent part reliability, Self-locking component reliability, Insertion end tension, Pull out tension of plug endMet design specifications and intended performancePassed/Met (Implied by conclusion of substantial equivalence)
    Optical PerformanceDirection of view, Field of view, Observation depth of field, Geometric distortion, SNR, Dynamic tolerance, Brightness uniformityMet design specifications and intended performancePassed/Met (Implied by conclusion of substantial equivalence)
    Color PerformanceColor restoration testMet design specifications and intended performancePassed/Met (Implied by conclusion of substantial equivalence)

    2. Sample Size Used for the Test Set and Data Provenance:

    • Sample Size: Not explicitly stated for each test. These are non-clinical (bench) tests, so the "sample size" would refer to the number of device units tested. This might range from a few units to a statistically significant number depending on the specific test and standard, but the document does not specify.
    • Data Provenance: The tests were conducted internally by the manufacturer (Hunan Vathin Medical Instrument Co., Ltd.) or by accredited labs on their behalf, likely in China given the company's location. This is inherently retrospective data gathered for the purpose of the 510(k) submission.

    3. Number of Experts Used to Establish Ground Truth and Qualifications:

    • Not Applicable. This section typically applies to studies where human interpretation of medical images or clinical data is involved. Since this document describes non-clinical, bench testing, no human experts were used to establish a "ground truth" in the clinical sense. The "ground truth" for these tests are the objective measurements against engineering specifications and international standards.

    4. Adjudication Method for the Test Set:

    • Not Applicable. As no human interpretation and subsequent need for consensus are involved in these non-clinical tests, no adjudication method was used.

    5. Multi-Reader Multi-Case (MRMC) Comparative Effectiveness Study:

    • No. The document does not describe any MRMC study. There is no mention of human readers or AI assistance.

    6. Standalone (Algorithm Only Without Human-in-the-loop) Performance:

    • No. This device is an endoscope, not an AI algorithm. Therefore, "standalone" AI performance is not applicable. The performance described is the inherent performance of the optical, mechanical, and electrical components of the device itself.

    7. Type of Ground Truth Used:

    • For Biocompatibility, Electrical Safety, EMC, and Sterility: Adherence to International Standards (e.g., ISO 10993, ISO 11607, ISO 11135, IEC 60601 series) and Regulatory Requirements.
    • For Functional, Mechanical, and Optical Performance: Engineering Specifications and Design Requirements agreed upon during device development.

    8. Sample Size for the Training Set:

    • Not Applicable. This device is a physical instrument, not an AI model that requires a training set of data.

    9. How the Ground Truth for the Training Set Was Established:

    • Not Applicable. As above, no training set is involved.

    In summary, the provided FDA clearence letter and supporting summary pertains to the substantial equivalence of a physical medical device (endoscope) based on its non-clinical performance and safety characteristics, not on the performance of a diagnostic AI algorithm or its impact on human readers.

    Ask a Question

    Ask a specific question about this device

    K Number
    K223836

    Validate with FDA (Live)

    Date Cleared
    2023-05-15

    (144 days)

    Product Code
    Regulation Number
    874.4680
    Age Range
    All
    Reference & Predicate Devices
    N/A
    Predicate For
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The Vathin® H-SteriScopeTM I Single use flexible Video Bronchoscope has been designed to be used with the Vathin® Displaying Unit, endotherapy accessories and other ancillary equipment for endoscopy within the airways and tracheobronchial tree.

    The Vathin® Video Bronchoscope System is for use in a hospital environment.

    Device Description

    Not Found

    AI/ML Overview

    I am sorry, but the provided text from the FDA 510(k) clearance letter for the Vathin® Video Bronchoscope System does not contain any information regarding acceptance criteria or a study proving the device meets acceptance criteria.

    The letter is a standard FDA clearance document that states the device has been found substantially equivalent to a legally marketed predicate device. It discusses regulatory aspects, such as general controls, potential additional controls for Class II/III devices, and compliance with various FDA regulations.

    It does not include details on:

    • A table of acceptance criteria and reported device performance.
    • Sample sizes for test or training sets, nor data provenance.
    • Number of experts or their qualifications for ground truth establishment.
    • Adjudication methods.
    • Multi-reader multi-case (MRMC) comparative effectiveness studies.
    • Standalone algorithm performance.
    • Type of ground truth used (e.g., expert consensus, pathology).
    • How ground truth for any set was established.

    Therefore, I cannot fulfill your request for this information based on the provided text. To obtain such details, you would typically need to refer to scientific publications, clinical trial reports, or other technical documentation directly submitted to the FDA, which are not part of this clearance letter.

    Ask a Question

    Ask a specific question about this device

    K Number
    K221580

    Validate with FDA (Live)

    Date Cleared
    2022-11-18

    (170 days)

    Product Code
    Regulation Number
    876.1500
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    N/A
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The Single-Use Flexible Cystoscope is designed to be used with the Vathin Display Unit, endotherapy accessories and other auxiliary device for endoscopy and treatment of adult bladder.

    Device Description

    The Single-use Flexible Cystoscope can be connected to the compatible Vathin Display Units and other accessories for the endoscopy and treatment of adult bladder.

    AI/ML Overview

    This document describes the validation of a Single-Use Flexible Cystoscope (K221580), comparing it to a predicate device, the Ambu Ascope 4 Cysto (K193095).

    Based on the provided text, there is no detailed study described that proves the device meets specific acceptance criteria based on clinical outcomes or performance metrics suitable for a table of reported device performance. The document primarily focuses on non-clinical testing to demonstrate substantial equivalence to the predicate device.

    Here's an analysis of the provided information relative to your request:

    1. A table of acceptance criteria and the reported device performance

    • Acceptance Criteria: The document lists numerous performance tests conducted. For each of these, acceptance criteria would have been established internally by the manufacturer, and the device's performance would have been compared against these. However, these specific acceptance criteria and the quantified reported device performance (e.g., 'Bending angle: device achieved X degrees vs. acceptance criteria Y degrees') are NOT provided in this FDA 510(k) summary. The document only states that "All evaluation acceptance criteria were met" for biocompatibility and that the system "complies" with electrical safety and EMC standards, and that various performance tests were "conducted."

    Therefore, a table cannot be fully constructed with the information given. The types of performance tests conducted are:

    Performance CharacteristicSpecific Test / MeasurementReported Device Performance (Not provided in detail)Acceptance Criteria (Not provided in detail)
    Physical DimensionsAppearance, Working length, Work channel ID, Head OD, Outer diameter of main hose, Maximum outer diameter of the insertion part, Product weight, Cable lengthStated to meet criteria(Internal Manufacturer Spec)
    Mechanical PerformanceBending angle, Rotating sleeveStated to meet criteria(Internal Manufacturer Spec)
    Functional PerformanceHandle-based photographing function, Image display, Waterproofness, Direction of view, Lens fogging, Suction ability, Water delivery ability, Handle-based camera button reliability test, Air tightness testStated to meet criteria(Internal Manufacturer Spec)
    Imaging PerformanceImage quality, Field of view test, Resolution test, Observation depth of field test, Geometric distortion test, SNR test, Dynamic tolerance test, Brightness uniformity test, Color reduction testStated to meet criteria(Internal Manufacturer Spec)
    Illumination PerformanceLED illuminance test, LED color temperature test, LED temperature testStated to meet criteria(Internal Manufacturer Spec)
    BiocompatibilityCytotoxicity, Irritation, Sensitization, Pyrogenicity, Acute systemic toxicity (evaluated per ISO 10993-1:2018 for "Surface – Mucosal Membrane" with contact < 24 hours)"All evaluation acceptance criteria were met"Per ISO 10993-1:2018
    Electrical Safety / EMCElectrical safety per IEC 60601-1 and IEC 60601-2-18, Electromagnetic compatibility (EMC) per IEC 60601-1-2"Complies with" standardsPer IEC 60601-1, IEC 60601-2-18, IEC 60601-1-2

    2. Sample size used for the test set and the data provenance (e.g. country of origin of the data, retrospective or prospective)

    • The document does not specify sample sizes for the non-clinical tests in terms of the number of devices tested for each characteristic. These tests are typically performed on a representative sample of devices.
    • Data Provenance: The tests were conducted by the manufacturer, Hunan Vathin Medical Instrument Co., Ltd., which is based in China. The data is from non-clinical bench testing, not patient data. Therefore, it is neither retrospective nor prospective in the clinical sense.

    3. Number of experts used to establish the ground truth for the test set and the qualifications of those experts (e.g. radiologist with 10 years of experience)

    • Not applicable. This document describes non-clinical performance and safety testing (e.g., measuring bending angle, image resolution, electrical safety). There is no "ground truth" derived from expert clinical assessment for this type of testing. Ground truth, in this context, would be the precisely measured physical or electrical properties per engineering standards.

    4. Adjudication method (e.g. 2+1, 3+1, none) for the test set

    • Not applicable. As this is non-clinical bench testing, there are no "readers" or adjudication methods as would be found in clinical studies involving interpretation of images or patient data by multiple experts. The tests are based on objective measurements against engineering specifications.

    5. If a multi-reader multi-case (MRMC) comparative effectiveness study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance

    • No MRMC study was done. This device is a flexible cystoscope, a medical instrument, not an AI-powered diagnostic algorithm. It is a tool used by human operators. The concept of "human readers improve with AI vs without AI assistance" does not apply to this submission.

    6. If a standalone (i.e. algorithm only without human-in-the-loop performance) was done

    • Not applicable. This is a medical instrument, not an algorithm. Therefore, "standalone" algorithm performance is not relevant.

    7. The type of ground truth used (expert consensus, pathology, outcomes data, etc.)

    • For the non-clinical performance and safety tests, the "ground truth" is derived from established engineering standards, test methods, and predefined measurement tolerances described in relevant international standards (e.g., ISO, IEC). For example, a "bending angle" test measures the actual mechanical bending angle of the scope, which is then compared against a specified design tolerance. It's objective measurement against a technical specification, not clinical ground truth like pathology.

    8. The sample size for the training set

    • Not applicable. This is a hardware device, not an AI model that requires a training set.

    9. How the ground truth for the training set was established

    • Not applicable. No training set is involved.

    In summary: The provided 510(k) summary focuses on demonstrating the substantial equivalence of the Single-Use Flexible Cystoscope through comprehensive non-clinical bench testing and adherence to recognized standards for biocompatibility and electrical safety. It does not include clinical studies, expert consensus reviews, or AI performance evaluations. The specific acceptance criteria and the quantitative performance results for each non-clinical test are not detailed in this public FDA summary.

    Ask a Question

    Ask a specific question about this device

    K Number
    K221581

    Validate with FDA (Live)

    Date Cleared
    2022-11-18

    (170 days)

    Product Code
    Regulation Number
    874.4760
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    N/A
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The Single-use Flexible Rhinolaryngoscope is designed for use with Vathin Display Units, for examination of nasal cavity and upper respiratory tract. For Rhinolaryngoscope models that include a working channel and permit the use of a compatible 3rd party accessory, treatment is also possible.

    Device Description

    The Single-use Flexible Rhinolaryngoscope can be connected to the compatible Vathin Display Units and other accessories for examination and treatment of nasal cavity and upper respiratory tract. There are eight subject nasopharyngoscope models: RL-S1800, RL-S1801, RL-E1800, RL-E1801, RL-S1E00, RL-S1E01, RL-E1E00, RL-E1E01. The main differences between product models are in the working channel inner diameter (whether channel is present or not), outer diameter, and rotate function.

    AI/ML Overview

    This document is a 510(k) summary for a medical device (Single-Use Flexible Rhinolaryngoscope) and primarily focuses on demonstrating substantial equivalence to a predicate device based on technical characteristics and non-clinical testing. It explicitly states that no re-review of the 510(k) submission was done for the administrative correction. Therefore, the provided text does NOT contain information regarding acceptance criteria or a study proving that the device meets acceptance criteria related to AI or algorithm performance.

    The document details the device's technical specifications and compares them to a predicate device, along with non-clinical tests (biocompatibility, electrical safety, EMC, and general performance testing) that are standard for medical devices of this type to ensure safety and effectiveness. It does not describe any studies involving algorithms, AI, or human reader performance.

    Therefore, I cannot provide the requested information based on the provided text, as it does not address AI/algorithm performance. The information requested (multi-reader multi-case studies, standalone algorithm performance, ground truth establishment, sample sizes for training/test sets in the context of AI) is not present in this regulatory submission document about a rhinolaryngoscope.

    Ask a Question