510(k) Data Aggregation

    K Number
    K250164

    Validate with FDA (Live)

    Date Cleared
    2025-08-14

    (205 days)

    Product Code
    Regulation Number
    880.6880
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    N/A
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The Cassette Autoclave (ACA5) is suitable for the sterilization of dental and medical instruments designed to withstand steam sterilization. The Cassette Autoclave (ACA5) has not been designed to sterilize liquids, bio-medical waste or materials not compatible with steam sterilization. The processing of such loads may result in incomplete sterilization and / or damage to the autoclave.

    Please refer to below sterilization cycles for Program Name / Load Description/Sterilization Temperature/Sterilization Time/Drying Time and Load Weight.:

    1. Program Name: 134 ℃
      Load Description: Solid objects, small porous objects, narrow-clearance items, dental handpieces and textile, wrapped or unwrapped.
      Sterilization Temperature: 134 ℃ (273℉)
      Sterilization Time: 4 minutes
      Drying Time: 60 minutes
      Load Weight: 0.9 kg

    2. Program Name: 121℃
      Load Description: Solid objects, small porous objects, narrow-clearance items, dental handpieces and textile, wrapped or unwrapped.
      Sterilization Temperature: 121 ℃ (250℉)
      Sterilization Time: 30 minutes
      Drying Time: 60 minutes
      Load Weight: 0.9 kg

    Device Description

    The Cassette Autoclave (ACA5) is a dynamic-air-removal (pre-vacuum) table-top steam sterilizer intended for use by a health care provider to sterilize medical products by means of pressurized steam. The Cassette Autoclave (ACA5) consists of five modules: water supply, disinfection, air dry, exhaust steam processing and control system.

    The main working principle is as follows: The water supply module supplies clean distilled water to the disinfection module. Inside the steam generator, the electric heating element generates high- temperature saturated steam at 121℃ for a period of 4 minutes and 134℃ for a period of 30 minutes. This steam is then utilized within a sealed disinfection box to sterilize instruments. During sterilization, excess high- temperature steam is condensed in the exhaust steam processing module. After the sterilization, high- temperature steam and coolant water remain inside the disinfection box. Air dry cycle works for ventilation and drying. Ultimately, you can get the dry and sterile instruments.

    Basic parameters/use conditions/power supply specifications are as follows:

    Name: Cassette Autoclave (ACA5)
    Machine Dimensions (ABC): 650mm416mm200mm
    Cassette Sizes (DEF): 495mm196mm78.5mm
    Maximum Load for a Single Sterilization: 1.5kg
    Sterilization Chamber Volume: 5.1L
    Weight (Without water): 43KG
    Rated Operating Temperature: 134℃
    Rated Working Pressure: 212kPa(Gauge Pressure)
    Relief Valve Pressure Setting: Pressure set: 300kpa (relative pressure), pressure release when exceeded
    Operating Temperature Range: 121℃~134℃
    Reservoir Volume: 4L
    Input Voltage: a.c.110v,60Hz
    Rated Power: 1300VA
    Fuse(250VH15AT): 10A
    Working Medium: Steam
    Illumination level: (215±15) lx to (1500±15) lx
    Operating Mode: Non--continuous operation, with a maximum of 6 cycles per hour.
    Water Supply: Purified water
    Noise: Less than 70dB
    Service life: 10 years

    AI/ML Overview

    The provided FDA 510(k) clearance letter is for a Cassette Autoclave (ACA5), which is a steam sterilizer. This type of device is an electromechanical product, not an AI/ML-driven diagnostic device. Therefore, the information typically requested about acceptance criteria and studies for AI/ML performance (such as sample sizes, ground truth establishment, expert adjudication, MRMC studies, and standalone performance) is not applicable to this document.

    The document discusses the device's performance in terms of its ability to sterilize medical instruments, adhering to established standards for steam sterilizers.

    Here's an analysis based on the information provided, focusing on the relevant acceptance criteria and performance metrics for a sterilizer:


    Acceptance Criteria and Device Performance for Cassette Autoclave (ACA5)

    This device is a medical instrument sterilizer. The performance criteria provided are related to the physical efficacy of sterilization, electrical safety, and electromagnetic compatibility, not diagnostic accuracy.

    1. Table of Acceptance Criteria and Reported Device Performance

    Test MethodPurposeAcceptance CriteriaReported Device Performance / Result
    ANSI AAMI ST55:2016 Vacuum TestVerify air removal performanceAverage leak rate of 1 milliliter of mercury (mmHg) (0.13 kPa) (0.019 psia) per min or lessPass
    Bowie Dick TestVerify air removal performanceThe Bowie-Dick-test indicator sheet shall show a uniform color change, i.e., the color in the center should be the same as that at the outer edges.Pass
    Temperature Control Performance (Hollow unwrapped (S) 134˚C/4min, Solid unwrapped(N) 134˚C/4min, Hollow wrapped(S) 134˚C/4min, Rubber/plastic(S) 121˚C/30min)Verify temperature control performanceThe chamber temperature during the exposure time remains within +3 ºC and –0 ºC of the selected sterilization exposure temperature.Pass
    Pressure Control Performance (Hollow unwrapped (S) 134˚C/4min, Solid unwrapped(N) 134˚C/4min, Hollow wrapped(S) 134˚C/4min, Rubber/plastic(S) 121˚C/30min)Verify pressure control performanceThe chamber pressure is within ±0.3 bar within the chamber.Pass
    Moisture Retention Performance (Hollow unwrapped (S) 134˚C/4min/dry 60min, Solid unwrapped(N) 134˚C/4min/dry 60min, Hollow wrapped(S) 134˚C/4min/dry 60min, Rubber/plastic(S) 121˚C/30min/dry 60min)Verify Moisture retention performanceNo visible moisture on outside of loads or instruments. Less than 2% moisture gain in PCD (textile test pack) and less than 0.5% moisture gain in PCD (wrapped instrument test tray).Pass
    Biological Performance (Hollow unwrapped (S) 134˚C/4min/dry 60min, Solid unwrapped(N) 134˚C/4min/dry 60min, Hollow wrapped(S) 134˚C/4min/dry 60min, Rubber/plastic(S) 121˚C/30min/dry 60min)Verify Biological performanceBiological indicators (BIs) and spore suspensions shall show no growth of test spores. Sufficient lethality to reduce microbial population with D121°C value of at least 1.0 min to a 10^-6 probability of surviving organism (overkill method).Pass
    IEC 61010-1:2010/AMD1:2016 IEC 61010-2-040:2020Verify electrical safetyMeets specifications of standardPass
    IEC 61326-1:2020Verify electromagnetic compatibilityMeets specifications of standardsPass

    2. Sample Size Used for the Test Set and Data Provenance

    The document does not specify the exact number of cycles or units tested for each performance metric. It states "The device had been validated to comply with the following bench testing." These are laboratory bench tests performed on the physical device itself, not studies on patient data. The provenance of this data is from the manufacturer's non-clinical testing.

    3. Number of Experts Used to Establish the Ground Truth for the Test Set and Qualifications of Those Experts

    Not applicable. Ground truth for sterilizer performance is established by metrological standards (temperature, pressure, moisture measurements) and microbiological testing (biological indicators), not by human expert consensus on diagnostic images.

    4. Adjudication Method for the Test Set

    Not applicable. Performance is measured against physical and biological thresholds, not requiring expert adjudication.

    5. If a Multi-Reader Multi-Case (MRMC) Comparative Effectiveness Study was done

    Not applicable. This is not an AI/ML diagnostic or image interpretation device.

    6. If a Standalone (i.e. algorithm only without human-in-the loop performance) was done

    Not applicable. This device is an electromechanical sterilizer. Its "performance" is its ability to meet the physical and biological parameters of sterilization, which is inherently a "standalone" function of the machine.

    7. The Type of Ground Truth Used

    The ground truth used for this type of device is based on accepted international standards for sterilization and electrical/electromagnetic safety. This includes:

    • Precise physical measurements (temperature, pressure, vacuum, moisture content).
    • Microbiological challenge tests using biological indicators to confirm the inactivation of spores to a specified sterility assurance level (SAL).

    8. The Sample Size for the Training Set

    Not applicable. This is a manufactured electromechanical device, not a machine learning algorithm that requires a "training set" of data.

    9. How the Ground Truth for the Training Set was Established

    Not applicable for the reason stated in point 8.

    Ask a Question

    Ask a specific question about this device

    K Number
    K202766

    Validate with FDA (Live)

    Device Name
    EOS Air Cleaner
    Date Cleared
    2021-06-11

    (263 days)

    Product Code
    Regulation Number
    880.6500
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    N/A
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    EOS Air Cleaner is a device intended for medical purposes that is used to destroy bacteria and viruses in the air by exposure to ultraviolet radiation in general medical environment.

    The core technology components of the EOS Air Cleaner have been demonstrated to destroy MS2 bacteriophage bioaerosol entrained on the filter to achieve an average 4 log reduction over 4 hours in a 30 cubic meter chamber.

    Device Description

    EOS Air Cleaner employs an ultraviolet air purification technology that destroys bacteria and viruses in air in hospital, nursing homes, medical facilities, but not in specialized medical place such as operating rooms.

    EOS Air Cleaner is a free-standing device, which has a well-sealed metal box including a fine filter, motor, two UV-C lamps, and a HEPA filter. By sucking surrounding air into the device, EOS Air cleaner can suction the air into the device and filtering the air by fine filter with UV-C light radiation, then the purified air is expelled from the cabinet.

    The bacteriophage deposited onto the surface of EOA Air Cleaner's proprietary photocatalytic coated filter media will be killed after exposure to EOS Air Cleaner's UV-C light

    UV-C light in 255 nm which is commonly called germicidal kills any remaining bacteria and viruses, as the radiation penetrates the cell walls of bacteria and is absorbed by the organic structures within the bacterial and virus, causing them to decompose and the cell to die.

    AI/ML Overview

    Here's the breakdown of the acceptance criteria and study information for the EOS Air Cleaner, based on the provided document:

    Acceptance Criteria and Device Performance

    Name of Test MethodologyPurposeAcceptance CriteriaReported Device Performance
    IEC 60601-1 / IEC 60601-1-2Demonstration of basic safety and essential performanceMeets criteria for CISPR Group 1APass
    Bacteriophage TestDemonstration of log reduction of viral loadAt least 4 log reduction of MS2 bacteriophagePass
    Aging TestDemonstration of continued function throughout service lifeAt least 4 log reduction of MS2 bacteriophagePass
    Software ValidationDemonstration of software security and good designMeets design criteriaPass

    Note regarding the Bacteriophage Test's Reported Performance: The "Indications for Use" section and the "Comparison of Technological Characteristics" table provide more specific performance details:

    • The core technology components have been demonstrated to destroy MS2 bacteriophage bioaerosol entrained on the filter to achieve an average 4 log reduction over 4 hours in a 30 cubic meter chamber.
    • Specific log reductions at different speeds (Speed 1: 4.05 / 4 hours, Speed 5: 4.22 / 4 hours, Speed 10: 4.45 / 4 hours) are also reported.

    Study Details

    1. Sample Size Used for the Test Set and Data Provenance:

      • The document does not explicitly state the sample size for the bacteriophage tests (e.g., number of test runs or replicates).
      • The data provenance is from non-clinical testing, likely conducted in a laboratory setting, and the manufacturer is Guangzhou Ajax Medical Equipment Co., Ltd. in China. The document does not specify if the data is retrospective or prospective, but it implies prospective testing for regulatory submission.
    2. Number of Experts Used to Establish the Ground Truth for the Test Set and Qualifications of Those Experts:

      • The document does not mention individual experts or their qualifications for establishing ground truth for the non-clinical tests. These types of tests typically rely on standardized laboratory protocols and measurements rather than expert consensus on individual "cases."
    3. Adjudication Method for the Test Set:

      • Not applicable as this involves non-clinical laboratory testing against pre-defined performance metrics, not human expert interpretation requiring adjudication.
    4. Multi-Reader Multi-Case (MRMC) Comparative Effectiveness Study:

      • No, an MRMC comparative effectiveness study was not done. The device is an air cleaner, and its performance is measured mechanically and biologically, not through human reader interpretation of medical images or data.
    5. Standalone (Algorithm Only Without Human-in-the-Loop Performance) Study:

      • Yes, the provided studies are standalone evaluations. The "Bacteriophage Test," "Aging Test," and "Software Validation" all evaluate the device's inherent performance and functionality without human interaction beyond operating and monitoring the device.
    6. Type of Ground Truth Used:

      • For the Bacteriophage Test and Aging Test: Direct measurement of viral load reduction (specifically MS2 bacteriophage bioaerosol) in a controlled environment. This is a scientific and empirical ground truth.
      • For IEC 60601-1/60601-1-2 and Software Validation: Adherence to established international standards and design criteria.
    7. Sample Size for the Training Set:

      • The document does not mention a training set or machine learning component for the EOS Air Cleaner. The device's function relies on physical processes (UV radiation, filtration) rather than an AI/ML algorithm that requires training data.
    8. How the Ground Truth for the Training Set Was Established:

      • Not applicable, as there is no mention of a training set or AI/ML algorithm.