Found 3 results

510(k) Data Aggregation

    K Number
    K061459

    Validate with FDA (Live)

    Device Name
    TRANQUIL TRI-BTE
    Date Cleared
    2006-06-30

    (35 days)

    Product Code
    Regulation Number
    874.3400
    Age Range
    All
    Reference & Predicate Devices
    N/A
    Predicate For
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The Tranquil TRI-BTE is for use in sound therapy for tinnitus retraining therapy, masking, or other recognized forms of tinnitus treatment. Sound therapy should be used in concert with counseling from a physician, an audiologist or other qualified tinnitus specialists.

    Device Description

    Not Found

    AI/ML Overview

    The provided document is a 510(k) substantial equivalence letter for the "Tranquil TRI-BTE" Tinnitus Masker. This type of letter does not typically contain detailed information about acceptance criteria or specific study protocols and results for device performance. It confirms that the device is substantially equivalent to a legally marketed predicate device, meaning it has the same intended use and technological characteristics, or different technological characteristics that do not raise new questions of safety and effectiveness.

    Therefore, based on the content of the provided document, I cannot answer the questions regarding acceptance criteria and the study that proves the device meets them. The document primarily focuses on the regulatory determination of substantial equivalence and general requirements for marketing the device.

    Ask a Question

    Ask a specific question about this device

    K Number
    K974751

    Validate with FDA (Live)

    Date Cleared
    1998-03-06

    (77 days)

    Product Code
    Regulation Number
    874.3300
    Age Range
    All
    Reference & Predicate Devices
    N/A
    Predicate For
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    A hearing Aid and/or Tinnitus Masker/Habituator. No hearing loss or a mild to severe high frequency hearing loss where the patient exhibits a low hearing loss where the patient's response to tinnitus is characterized by intolerance to specifically the inability to cope with head noises, anxiety, depression or the inability to function in daily life activities. When cosmetics are not an issue.

    A hearing Aid and/or Tinnitus Masker/Habituator. No hearing loss or a mild to severe high frequency hearing loss where the patient exhibits a low hearing loss when the patient's response to tinnitus is characterized by intolerance to specifically the inability to cope with head noises, anxiety, depression or the inability to function in daily life activities. When cosmetics are an issue.

    A hearing Aid and/or Tinnitus Masker/Habituator. No hearing loss or a mild to severe high frequency hearing loss where the patient exhibits a low hearing loss where the patient's response to tinnitus is characterized by intolerance to specifically the inability to cope with head noises, anxiety, depression or the inability to function in daily life activities. When cosmetics are a major issue.

    Device Description

    Tranquil TRI-OE: I-T-E hearing aid and/or tinnitus masker/habituator with Class A Noise Generator, Class D Noise Generator, DSD K-amp programmable or Intrigue Programmable. Assembled from standard components. Technical specifications comply with S3 2-1987 ANSI Standards. Frequency response dictated by individual audiogram. Volume control mechanical or electronic. Standard Size 312 battery.

    Tranquel TRI-COE: I-T-C hearing aid and/or tinnitus masker/habituator with Class A Noise Generator, Class D Noise Generator, DSD K-amp programmable or Intrigue Programmable. Assembled from standard components. Technical specifications comply with S3 2-1987 ANSI Standards. Frequency response dictated by individual audiogram. Volume control mechanical or electronic. Standard Size 10A battery.

    Tranquel TRI-CIC: C-I-C hearing aid and/or tinnitus masker/habituator with Class A Noise Generator, Class D Noise Generator, DSD K-amp programmable or Intrigue Programmable. Assembled from standard components. Technical specifications comply with S3 2-1987 ANSI Standards. Frequency response dictated by individual audiogram. Volume control mechanical or electronic. Standard Size 10A battery.

    AI/ML Overview

    The provided text does not contain information about specific acceptance criteria, a study proving device performance against those criteria, or details regarding sample sizes, ground truth establishment, or expert involvement in such a study.

    The documents are a 510(k) summary of safety and effectiveness information for the "Tranquil TRI-OB, TRI-COE & TRI-CIC Tinnitus Maskers / Hearing Aids". This type of submission is for demonstrating
    substantial equivalence to a predicate device already legally marketed, rather than proving performance against novel acceptance criteria through a specific study.

    Here's what the documents do provide:

    • Intended Use: A hearing Aid and/or Tinnitus Masker/Habituator for patients with no hearing loss or mild to severe high-frequency hearing loss, where the patient's response to tinnitus is characterized by intolerance, specifically the inability to cope with head noises, anxiety, depression, or inability to function in daily life activities. The "Tranquil TRI-OE" is for when cosmetics are not an issue, "Tranquil TRI-COE" for when cosmetics are an issue, and "Tranquil TRI-CIC" for when cosmetics are a major issue.
    • Technical Characteristics: "Technical specifications comply with S3 2-1987 ANSI Standards." This is the closest thing to an acceptance criterion mentioned, but it refers to a general standard compliance rather than specific performance metrics unique to this device.
    • Device Features: Class A Noise Generator, Class D Noise Generator, DSD K-amp programmable or Intrigue Programmable.
    • Assembly: Assembled from standard components widely used by other hearing aid manufacturers.
    • Regulatory Classification: Class III, Procode: 77 KLW/77 ESD, under 21 CFR 874.3400/21 CFR 874.3300.
    • Substantial Equivalence: The FDA letter (Document 3) explicitly states that the device is found to be "substantially equivalent" to predicate devices marketed prior to May 28, 1976. This is the basis for its clearance, not a new performance study.

    Therefore, based on the provided text, I cannot answer the questions about acceptance criteria, a specific study, sample sizes, ground truth, or expert involvement because this information is not present in a 510(k) summary demonstrating substantial equivalence. Such details would typically be found in detailed clinical trial reports or design verification/validation documents, which are not part of this submission.

    Ask a Question

    Ask a specific question about this device

    K Number
    K971399

    Validate with FDA (Live)

    Date Cleared
    1997-06-13

    (59 days)

    Product Code
    Regulation Number
    874.3300
    Age Range
    All
    Reference & Predicate Devices
    N/A
    Predicate For
    N/A
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    Mild to severe conductive, mixed or sensoryneural hearing loss
    Mild to severe conductive, mixed or sensoryneural hearing loss when cosmetics are of some concern
    Mild to moderate conductive, mixed or sensoryneural hearing loss when cosmetics are of major concern, but the ear can not accommodate a complete in the canal style
    Mild to moderate conductive, mixed or sensoryneural hearing loss when cosmetics are of major concern.
    Mild to severe conductive, mixed or sensoryneural hearing loss when a more cosmetic AE is desired.
    Mild to severe conductive, mixed or sensoryneural hearing loss when cosmetics are a major concern but the ear prevents use of a CIC or MM.
    Normal low and middle frequency hearing with a sloping mild to moderate high frequency sensory neural or mixed loss.

    Device Description

    To amplify and transmit sound to the ear.
    DSD K-amp or Intrigue programmable circuitry
    Assembled from standard components that are widely used by other hearing aid manufacturers.
    "Technical specifications comply with S3.2-1987 ANSI Standards"
    Frequency response dictated by individual audiogram
    Volume control similar to other devices.
    Standard size 13 battery
    Standard size 312 battery
    Standard size 10A battery
    Standard size 10a or 5a battery

    AI/ML Overview

    I am sorry, but the provided text does not contain information about acceptance criteria, device performance, study details, or ground truth establishment for the Auris hearing aids. The documents describe different models of Auris hearing aids, their intended use, features, technical characteristics, and the FDA's 510(k) clearance approval, but they do not include any specific clinical study data or performance metrics against defined acceptance criteria.

    Ask a Question

    Ask a specific question about this device

    Page 1 of 1